Loading...
10-528-001EXISTING HOUSE REMODELING AND UTILITY ROOM TO BE LEGALIZE FOR RAUL AB,DA A AT 11435 SW 58th AVE MIAMI, FL 33143 0 BUILDING ADDRESS: 6430 SW 58 AVE MIAMI, FLORIDA 33143 -3608 LEGAL DESCRIPTION: LOT 78, OF "UNIVERSITY PARK" ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 18 AT PAGE 46 OF THE PUBLIC RECORDS OF MIAMI —DADE COUNTY, FLORIDA. SCOPE OF WORK — REMOVE EXISTING HOUSE INTERIOR PARTITION, CEILING AND DOOR — REMOVE EXISTING HOUSE ROOF FRAMING — PROVIDE NEW TRUSS ROOF FRAMING TO ALL EXIST. HOUSE — PROVIDE NEW INTERIOR PARTITION, CEILING AND DOOR TO HOUSE — PROVIDE NEW WALL HEIGHT TO EXIST. LEGAL ATTACHED ADDITION —ALL ELECTRICAL WIRE, CIRCUITS, FICTURES, PANEL AND METER WILL BE NEW. — MECHANICAL EQUIPMENT AND CONDUCTS WILL BE NEW —ALL PIPES & FICTURES WILL BE NEW & RELOCATE LAUNDRY IN DETACHED UTILITY ROOM — DETACHED UTILITY TO BE LEGALIZE. PROJECT INFORMATION ZONING INFORMATION: AKLA AND ZONING: RS -4 LOTAREA ': .............................................................. 6,000 SQ /F .................... BUILDING AREA : EXIST. BUILD AREA: ............ ............................... 1588 S0 /F TOTAL UTILITY ROOM ADDITION: ........................................ 140 SQ /F 1728 SQ /F MAX. LOT COVERAGE PERMITED 30% =1800 SQ /F PROPOSED LOT COVERAGE 28.8% =1728 SQ /F BUILDING HEIGHT: 13' -7" < 25.00' MAX. NUMBERS OF STORIES : ONE SET BACKS: FRONT: REAR: SIDE: REQUIRED 25.0' 25.0' 7' -5" AT EACH SIDE PROPOSED 25.75' 27.54 9.12' (LEFT) — 15.77' (RIGHT) PROPOSED GREEN AREA /OPEN SPACE ...................... ...........................3690 SQ /F (61.5 %) - t1 , (3'� �,7C eh1�'r!� ,. { � y 1.5 � •K• S�,C d'�'sy K ("� r'+N •.� I = ,��, i.l ""`° ¢` za.+;. ""fir`• t <. s�it i "t•fV, r _ P' A �'•, it ... _ fIAROfE DR SW 164TH ST HARflEf RD Z NT c t =i a It k:. :. M. •T SSfJa'1.ut as s rD a r.`* rn e IC _; �`' �� �.. Wig;•, " =!! - � �'�+(-' - d:� ■ - ` �� , a ��} �?, � -+ Y 1� :� •R AN SW 66TH ' r +� [jam {(j"'�_��. :Q. - y - 6 { } � • �j A Tim aY� r.,t G 1[_'.�,[•'r/d v iii. 1 ,f +��` LOCATION MAP 0 o TREE TR NK I I ` F_ Chain Link Fence 60.00' > ELECTRICAL PANEL II u ROPE OFF DEMOLITION ZONE FOR PUBLIC SAFETY O rev TRI('A is FLOOR PLAN) ffffff I1 FFFF1111 II —ALL ELECTRICAL WORK SHALL BE EXECUTED FOR A LICENSE ELECTRICAL CONTRACTOR AND A PERMIT SHALL BE REQUIRED. I I — DISCONNECT THE GENERAL ELECTRICAL MAIN BEFORE REMOVE ALL INTERIOR I I PROCEEDING TO DISCONNECT ANY ELECTRICAL LINE I I 10' 14.80 AND CEILING N — EXISITING ELECTRICAL PANEL SHALL BE ROMOVED C4 N — EXISITING ELECTRICAL METER SHALL BE ROMOVED I I MFCHANICAI: LIVING 0 � Building a I I — EXISTING A/C EQUIPMENT SHALL BE REMOVE I I IMRINh- PA 6 — —ALL EXIST. PLUMBING FICTURES SHALL BE REMOVED I I AND NEW FICTURES WILL BE ISTALLED IN SAME LOCATION a Elev.= +12.95 15.8' I S OTHFR - - - - - - � - REMOVE ROOF TRUSS FDA � N CD CD C) EXISTING 16.45' 15.77 Z3 UTILITY cr 0 REMOVE CP r 10.7' rb o � I- 9.12' 9- i xz o ^ 0 0 . . 0 �. o ONE STORY RESIDENCE 0 0 6430 S.W. 58TH AVENUE o A/C "'- FINISH FLOOR y 5 PAD ELEV. = +13.43' +13.43 9.12' 35 10' x��6 0.2' ENTRY �* o 0 0 r- 0 Li T Ca 60.00' 5' Sidewalk (Basis of Bearing) LO t10' PARKWAY N SA` 58th_ Avenue. ' � - � -centerline • Pavement 50' TOTAL - RIGHT —OF —WAY SITE PLAN CALE: 1"=20' EXISTING 3 "X3" LALLY COLUMN TO BE REMOVED (SEE PROPOSED FOUNDATION PLAN FOR NEW SOLUTION) EXIST. WINDOW TO REMOVE EXIST. DOOR_ TO REMOVE RELOCATE ELECTRICAL METER (SEE PROPOSED FLOOR PLAN) W I li_ 0 a it L -0 C-) 7z 0 °. m II II II ASTER I; l; I EDROOM REMOVE ALL HOUSE ROOF FRAMING (SEE PROPOSED ROOF FRAMING PLAN IN SHEET S -3 FOR NEW ROOF) SCALE: 1/4"=I'— EXIST. WINDOW TO REMOVE THE ORIGINAL WALL HEIGHT OF THIS ADDITION WAS OF 34.75" QLA11111 Ili–fill 11 11 111 111 WITH WOOD COLUMNS AND WOOD BEAM SUPPORTING THE WOOD JOIST ROOF FRAMING AND ALL THE REST OPENING WAS ENCLOSED WITH WINDOWS, ALL THIS IN ACCORDANCE WITH THE MICROFILM ATTACHED TO THIS PLAN. THE MASONRY BLOCK ENCLOSED AT MORE OF THE 38.75" IGH WAS MADE WITHOUT PERMIT AND SHALL BE DEMOLISHED. FAMILY A NEW MASONRY BLOCK WALL CONNECTED TO EXISTING 38.75" ROOM HIGH MASONRY BLOCK WALL WILL BE PROVIDE, NEW VERTICAL REINFORCING FOR ALL ADDITION WALLS AND A NEW CONCRETE TIE BEAM WILL BE PROVIDED. (SEE EXISTING FAMILY ROOM WAL CONDITION AND PROPOSED FAMILY ROOM WALL SECTIONS IN SHEETS-2) GENERAL NOTES: 1.— ALL VYUMN Z ALL bL IN ACCUHUANCE WITH THE LATEST EDITION OF THE FLORIDA BUILDING CODE 2007 AND WITH THE REQUIREMENTS OF THE CITY OF HIALEAH, STATE & NATIONAL LAWS AND CODES, ANY DISCREPANCIES BETWEEN THE PLANS AND ABOVE REQUIREMENTS MUST BE CALLED TO THE A /E'S ATTENTION BEFORE PROCEEDING WITH ANY WORK. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE PLANS. 2.— CONTRACTOR FAMILIARIZE HIMSELF WITH THE CONTRACT DOCUMENTS BEFORE COMMENCEMENT WITH THE CONSTRUCTION CLARIFY ANY DISCREPANCIES WITH THE A/E ANDTHE CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES TO INSURE THAT IT IS COMPLETED AS INTENDED IN THE PLANS. 3.— CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS, INCLUDING MAKING SURE THAT ALL SUBCONTRACTOR'S OBTAIN THEIR PERMITS, INSPECTIONS AND APPROVALS FROM GOVERNING AGENCIES WITH JURISDICTION OVER THE PROJECT BEFORE BEGINNING WORK. 4. —ALL WORK PERFORMED UNDER THIS CONTRACT SHALL COMPLY WITH THE REQUIREMENTS OF THE UTILITY COMPANIES INCLUDING THE CITY OF HIALEAH PUBLIC WORKS DEPARTMENT, WHOSE SERVICES SHALL BE USED. ALL MANUFACTURERS SHALL SUBMIT SHOP DRAWINGS TO THE A/E FOR APPROVAL PRIOR TO FABRICATION. 5. —THE A/E WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, CONSTRUCTION SA ��PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK, OR THE CONTRACTOR'S FAILURE TO CARRY OUT THE WORK IN ORDANCE WITH THE CONTRACT DOCUMENTS. y 6. RIAL AND WORKMANSHIP SHALL MEET THE REQUIREMENTS OF APPLICABLE STANDARD SPECIFICATION OF THE AMERICAN SOCIETY FOR TESTING AND MATERIALS. 7.— THE GENERAL CONTRACTOR MAY SUBSTITUTE EQUIPMENT AND /OR MATERIALS AS LONG AS SUCH CHANGES MEET ALL F.B. CODE REQUIREMENTS AND ARE EQUAL TO THOSE SPECIFIED IN THE PLANS. THE CONSTRACTORS MUST OBTAIN OWNER'S APPROVAL IN WRITING FOR ACCEPTANCE OF SUCH CHANGES. 8.— CONTRACTOR SHALL SUBMIT DADE COUNTY PRODUCT CONTROL APPROVAL FOR WINDOWS, ROOFING & WATER PROOFING COMPONENTS AND ALL OTHER PRODUCTS REQUIRING SAID APPROVAL, 9.— WORKMANSHIP: ALL WORK SHALL BE PERFORMED IN A MANNER CONSISTENT WITH THE BEST PRACTICES FOR THE RESPECTIVE TRADES AND QUALITY SPECIFIED. WORK NOT CONSISTENT WITH THE TRADES HIGHEST LEVEL OF WORKMANSHIP WILL BE REJECTED. ANY WORK REJECTED SHALL BE REDONE AT CONTRACTOR'S EXPENSE. CORRECTION FOR DEFECTIVE WORK SHALL COMMENCE NO LATER THAN FIVE DAYS AFTER NOTICE IS GIVEN TO THE CONTRACTOR, AND SHALL PROCEED WITHOUT DELAY UNTIL WORK IS COMPLETED. 10.— CLEANUP: THE CONTRACTOR AND ALL TRADES SHALL AT ALL TIMES KEEP THE PREMISES CLEAN OF DEBRIS ARISING OUT OF THE WORK AND FREE FROM ACCUMULATIONS OF WASTE MATERIALS OR RUBBISH CAUSED BY HIS OPERATIONS OR OTHER TRADES. THE CONTRACTOR SHALL PROVIDE AT ALL TIMES A TRASH CONTAINER ADEQUATE FOR THIS JOB. THE CONTRACTOR SHALL DELIVER ALL WORK UPON COMPLETION OF THE JOB IN A CLEAN, READY —TO —USE CONDITION. ALL FINISHED SURFACES SHALL HAVE PROTECTIVE COVERINGS REMOVED, AND SURFACES CLEANED OF ALL MARKS, STAINS, SOIL, PAINT, OR ADHESIONS OF OTHER KITCHEN DINING DEMOLITION PRO MATERIALS AND LEFT IN PERFECT CONDITION. ROOM , I CEDURE Y� r RELOCATE SAFETY. > ELECTRICAL PANEL II u ROPE OFF DEMOLITION ZONE FOR PUBLIC SAFETY (SEE PROPOSED TRI('A is FLOOR PLAN) ffffff I1 FFFF1111 II —ALL ELECTRICAL WORK SHALL BE EXECUTED FOR A LICENSE ELECTRICAL CONTRACTOR AND A PERMIT SHALL BE REQUIRED. I I — DISCONNECT THE GENERAL ELECTRICAL MAIN BEFORE REMOVE ALL INTERIOR I I PROCEEDING TO DISCONNECT ANY ELECTRICAL LINE I I I PARTITION, DOOR CARPORT —ALL EXISTING ELECTRICAL LINE OF SHALL BE REMOVED I I AND CEILING N — EXISITING ELECTRICAL PANEL SHALL BE ROMOVED C4 N — EXISITING ELECTRICAL METER SHALL BE ROMOVED I I MFCHANICAI: LIVING I I —ALL EXIST. CONDUCTS SHALL BE REMOVED ROOM I I — EXISTING A/C EQUIPMENT SHALL BE REMOVE I I IMRINh- PA 6 — —ALL EXIST. PLUMBING FICTURES SHALL BE REMOVED I I AND NEW FICTURES WILL BE ISTALLED IN SAME LOCATION I I FRONT I - C =Ta_ - I S OTHFR - - - - - - � - REMOVE ROOF TRUSS FDA MING (X CEILING FRAMING MEMBERS. — REMOVE INTERIOR PARTITION —ALL DEMOLITION MATERIALS SHALL BE DISPOSED OF LEGALLY —A FINAL INSPECTION SHALL BE REQUIRED. SC)U -ttA N11A�t CITY OF SOUTH IV71AM1' 13UILDING DEPT " PPROVED SY. C1Twq A A A