09-432-001
SPLIT SYSTEM - OUTDOOR UNIT SCHEDULE SYSTEM N0. SERVICE COOLING CAPACITY SEER 16.00 ELECTRICAL REFRIG. PIPING DIMENSIONS(IN) WEIGHT (LBS) MANUFACTURER BRYANT MODEL 180ANA060 -C TOTAL 58500 SENSIBLE BTU/HR 43800 VOLT.PH. -CY 208/230 -1 -60 LIQUID 3/8 " SUCTION 7/8 " H W D 1 WHOLE HOUSE PROVIDE (4) J" ANCHOR BOLTS OF 500 LBS MIN. PULL OUT CAPACITY ON THE BASE OF THE PAN TO PENETRATE CONCRETE 142" MIN AS PER MANUFACTURER RECOMMENDATION TO WITHSTAND _ — — — — 150 MPH WINDS. 4" CONCRETE SLAB n i4 a NEOPRENE PAD (TYPICAL) _�Z CONDENSING UNIT MOUNTING DETAIL I I.I.J. 1780 CFM, 950 FPM, F. RATE: 0.075 I.W.G. 018.5 ", 16 "X18" R -6 SUPPLY PLENUM. PROVIDE (2) 2 "X2 "X�" U- CHANNEL ATTIC GA. 18 FASTENED TO THE PLENUM SEAL W/ (2) J "X2" SCREWS WITH PENS WASHERS. ��r PLENUM FACTORY INSTALLED CIRCUIT BREAKER. 0j" OD LIQUID LINE THROUGH ATTIC TO C /U. 4" OD SUCTION LINE THROL ATTIC TO C /U, INSULATED. 0j" PVC DRAIN LINE 0j" OD DRAIN LINE THROUGH ATTIC TO SOIL AREA, INSULATED. DRAIN PUMP LITLE GIANT MODEL VCMA- 15ULS, 115 V, 65 GALS XH® 1 ",�HPOR AS SELECTED BY CONTRACTOR. ATTIC CEILING AROUND A /H. A/H REMOVABLE PERFORATED CAP PROVIDE A FLOW SWITCH IN 0j "OD DRAIN PAN. DRAIN NEOPRENE PADS VENT. 23"W x 22 "H x 231 ALUMINUM Tum plenum STAND SECURE TO FLOOR SLAB THRU ANCHOR BOLTS. 24� X24" SIDE WALL TYPE GRILLE WITH FILTER TO RETURN PLENUM. AIR HANDLER INSTALLATION DETAIL N. T. S. 24' -7" NOTES: • ALL DUCTWORK TO BE R -6. • ALL DIFFUSERS ARE CEILING TYPE. • DRAIN PUMP INSTALLED BY MANUFACTURER RECOMMENDATIONS. • PROVIDE TURNING VANES AT ALL SQUARE ELBOWS. V HVAC DESIGN REQUIREMENTS YES NO DUCT SMOKE DETECTOR HEIGHT AREA(S.F.) FIRE DAMPER(S) SH 23 3' -1" SMOKE DAMPER S 9.86 FIRE RATED ENCLOSURE 4' -5" i/ F.RATED R CEILING ASSEMBLY © V" FIRE STOPPING 4' -2" Vol SMOKE CONTROL 2(SH 25) ✓ WOOD BEAM #12 GE. HANGER WIRE SHEET MET L SCREW ' 1-1/2"x26 GE. STRAP HANGERS AT 5' MAX. SEE PROJECT FOR SIZE FLEXIBLE DUCT HANGERS n.t.s. TYPICAL J —O" !r HVAC GENERAL NOTES 1. DO NOT SCALE THIS DRAWING FOR EXACT DIMENSIONS AT THE JOB SITE. THE MECHANICAL PLANS ARE INTENDED TO BE DIAGRAMMATIC AND ARE BASED ON ONE MANUFACTURER EQUIPMENT. THEY ARE NOT INTENDED TO SHOW EVERY ITEM IN ITS EXACT LOCATION, THE EXACT DIMENSIONS, OR ALL THE DETAILS OF THE EQUIPMENT. THE CONTRACTOR SHALL VERIFY THE ACTUAL DIMENSION OF THE EQUIPMENT PROPOSED TO ENSURE THAT THE EQUIPMENT WILL BE Fir IN THE AVAILABLE SPACE. WINDOW SCHEDULE MARK TYPE WIDTH HEIGHT AREA(S.F.) 0 SH 23 3' -1" 3' -2" 9.86 SH 34 4' -5" 4' -2" 18.67 © 2(SH 24) 6' -2" 4' -2" 26.10 ® 2(SH 25) 6' -2" 5' -3" 32.48 © 2(SH 34) 8' -10" 4' -2" 34.02 ® 3(SH 25) 9' -3" 5' -3" 49.29 P. WINDO 3' -1" 7' -0" 21.7 ® LDG.D00 6' -0" 7' -0" 41.00 PROPERTY LINE: >10' -0" N.T.S. I north a�f�= ,.. FLOOR PLAN - MECHANICAL SCALE: 1/4"-T-0" gDENSER UNIT "HORED TO JCRETE SLAB. 24' -8" DETAIL. J1 10' b AND SEE ETAIL. General Notes W U Z W 0 W z Q Q�r ��J Q� n —cc _ JrG JNQ Revision /Issue Date a ..a i } LL �LW �W� wu�iz ZOO U NZi- W WzU30i W � M FCC F Z cl) J O � DFl 0 �T � Q r � �o N 0 — a ro t/1 2 2 LL �y n j LU R 0 0 �o 41 � a6 i 0 0° 0� Sheet M-1 t