13-1219R-005O ! 1) WIND LOADS: PRESSURES (C&C) ON F.B.C. 2010 ON 10 SQUARE FEET ASCE 7 -10 NAILING ULTIMATE WIND SPEED = 175 MPH EXPOSURE = C = -618 PSF RISK CATEGORY = II = -94.4 PSF MEAN ROOF HEIGHT = 15 FT BASE WIND PRESSURE = 33.9 PSF Kz = Kh = 0.85 Kd = 0.85 +EImmt# m ULTIMATE UPLIFT ROOF PRESSURES (C&C) ON ROOF COVERING BASED ON 10 SQUARE FEET EFFECTIVE AREA. NAILING ZONE: in = -36.7 PSF ZONE: 2 = -618 PSF ZONE: 3 = -94.4 PSF 2) GRAVITY LOADS: NAIL SIZE A) I= B) LIVE LOAD: 30 PSF DEAD LOAD: V • TRUSS TOP CHORD 15 PSF • TRUSS BOTTOM CHORD 10 PSF TOTAL LOAD 55 PSF 0 C.L.B. - 2 "x4" BOTTOM CONTINUOS LATERAL BRACING D.B. - 2 "x4" BOTTOM DIAGONAL BRACING. G•T- - GIRDER TRUSS UM(3x- - MAX. NOMINAL NET DESIGN UPLIFT FORCE IN WOOD CONNECTOR. Vz - DESIGN SHEAR FORCE PERPENDICULAR TO THE WALL IN WOOD CONNECTOR - TERMINATE COLUMN /TIE COUMN TYPE f ! Igol a g ml • ALL WOOD IN DIRECT CONTACT • OR MASONRY --.'E NATURALLY DURABLE SPECIES, OR PRESSURE TREATED WOOD PEr� AMERICAN ••f PRESERVES ASSOCIATION - WOOD TRUSSES @ CON11NUOUS O.0 LATERAL BRACING L20' -0" MAX. PERMANENT BRACING IN THE PLANE OF THE WEBS, CONTINUOS LATERAL BRACING PLYWOOD ROOF SHEAR DIAPHRAGM SCHEDULE < FRAMING MINIMUM NAILING COMMON Ir PANEL GRADE TRUSS PANEL SCHEDULE NAIL SIZE REMARKS I= a SPACING THICKNESS V � O ROOF APA RATED SHEATHING 2 " -O" 1932" 6" ® ZONE: 1 8d RING GABLE ENDS EXPA L NOM. SHANK (SEE NOTE: 5) � 4" @ ZONE: 2 & 3 NAILS FRAMING NOTES: IF 1. INSTALL PLYWOOD PANELS AS SHOWN ON DETAIL ABOVE. DIAPHRAGM BOUNDARIES 2. OSB SHEATHING IS NOT ALLOWED IN THE HIGH VELOCITY HURRICANE ZONES "HVHZ ". 3. PLYWOOD ROOF SHEATHING CD GRADE, AND SHALL BE RATED FOR EXPOSURE 1, WITH A MINIMUM NOMINAL THICKNESS OF 1%2" AND SHALL BE CONTINUOUS OVER (2) OR MORE SPANS WITH THE LONG DIMENSION OR STRENGTH AXIS OF THE PANEL PERPENDICULAR TO SUPPORTS. 4. PANEL END JOINTS SHALL OCCUR OVER TRUSSES. JOINTS SHALL BE STAGGERED AND PARALLEL TO THE TRUSSES, AND ENDS AT DIAPHRAGM BOUNDARIES SHALL BE ATTACHED TO A MINIMUM 2- INCH -THICK NOMINAL FASCIA BOARD. 5. ROOF SHEATHING PANELS SHALL BE PROVIDED WITH THE MINIMUM OF 2x4 EDGEWISE BLOCKING AT ALL HORIZONTAL PANEL JOINTS FOR A DISTANCE AT LEAST 4 FEET FROM EACH GABLE END. UNLESS OTHERWISE NOTED. 6. ZONES 1, 2 & 3 ARE AS SHOWN ON UPLIFT DIAGRAM ABOVE. WOOD TRUSSES BRACING NOTES: A. PERMANENT WEB BRACING SHALL BE INSTALLED ACCORDING TO INDIVIDUAL TRUSS DRAWING. REFER TO SHOP DRAWINGS. (WEB BRACING IS NOT SHOWN ON ROOF FRAMING PLAN). HOWEVER, THE PERMANENT WEB AND HORIZONTAL LATERAL BRACING SHALL MEETS AT LEAST THE MINIMUM REQUIREMENTS SPECIFIED IN THIS SHEET. THE PERMANENT WEB AND HORIZONTAL LATERAL BRACING SHALL BE RESTRAINED TO PREVENT LATERAL MOVEMENT BY SOLID ANCHORAGE TO END WALLS, OR BY PERMANENT DIAGONAL BRACING IN THE PLANE OF THE WEB MEMBER AT INTERVALS NOT TO EXCEED TWENTY (20) FEET ALONG CONTINUOUS WEB BRACE. (REFER TO HIB -91, SECTION 1323.1 AND DETAILS BELOW ON THIS SHEET. IN THE EVEN OF CONFLICT BETWEEN SHOP DRAWINGS AND THE ENGINEER OF RECORD PERMANENT LATERAL BRACING REQUIREMENTS, THE PROVISIONS OF THE MORE STRINGENT SHALL GOVERN. B. ALL TOP CHORDS ARE ASSEMBLED TO BE SHEATHED, AND ALL BOTTOM CHORDS SHALL BRACED BY A CONTINUOUS LATERAL BRACING SPACED NOT MORE THAN 10 FEET. REFER TO INDIVIDUAL TRUSS DRAWINGS FOR ACTUAL BRACING REQUIREMENTS. THE DRYWALL CEILING IS NOT TO BE CONSIDERED A CEILING DIAPHRAGM. C. BRACING SHOWN ON PLANS DOES NOT INCLUDE TEMPORARY BRACING REQUIRED FOR THE ERECTION AND INSTALLA11ON OF TRUSSES PRIOR TO THE INSTALLATION OF PERMANENT CROSS BRACING AND WEB LATERAL BRACING REQUIREMENTS. TEMPORARY BRACING IS THE RESPONSIBILITY OF THE CONTRACTOR AND SHOULD REMAIN IN PLACE AS LONG AS NECESSARY FOR THE SAFE AND ACCEPTABLE INSTALLATION OF THE ROOF OR FLOOR. (REF: HIB -91 SUMMARY SHEET). D. REFER TO 'HIB -91 COMMENTARY AND RECOMMENDATIONS FOR HANDLING, INSTALLATION AND BRACING METAL PLATE CONNECTED WOOD TRUSSES', APPENDIX C, FOR RECOMMENDED SEQUENCE OF INSTALLING BRACING COMPONENTS. 2 "x4" PERMANENT WEB DIAGONAL CROSS BRACING WITH 2 -16d COMMON NAILS TO AT EACH INTERSECTION. MAY TRANSVERSE MORE THAN TWO TRUSSES DEPENDING ON TRUSS HEIGHT. (TYP.) 10' -0" MAX. --1 10 " -0" MAX. 10' -0`" MAX. DIAGONAL BRACING IN THE PLANE OF THE BOTTOM CHORD 2 "x4" CONT. LATERAL BRACING — NAILED TO EACH TRUSS W/(2) -16d NAILS. ALL SPLICES TO OCCUR OVER TWO TRUSS SPANS. 2 "x4" DIAGONAL BRACING NAILED TO BOTTOM CHORD PREVENTS LATERAL MOVEMENT AND SHALL BE REPEATED AT EACH END AND AT THE SAME INTERVALS NOT MORE THAN 20 FEET IN DIRECTION OF HORIZONTAL BRACING. NOTE: WHERE A CEILING IS TO BE ATTACHED DIRECTLY TO THE UNDERSIDE OF TRUSSES, THE TRUSSES SHALL BE LATERALLY BRACED W/ CONTINUOS 2X4 MEMBERS NAILED W/ (2) 16D COMMON NAILS TO THE UPPER SIDE OF THE BOTTOM CHORD AT PANEL POINT BUT NOT TO EXCEED 10 FT APART. THIS LATERAL BRACING SHALL BE RESTRAINED AT EACH END AND AT 20 FT INTERVALS. DRAYWALL MAY BE CONSIDERED A RIGID CEILING IN ENCLOSED AREAS WHERE IT IS PROTECTED FROM THE ELEMENTS . THE DRYWALL CEILING IS NOT TO BE CONSIDERED A CEILING DIAPHRAGM. PLAII VIETT .. ENGINEERED & APPROVED WOOD ROOF TRUSS @ • OVERLAP DETAIL m a n � m ma n � m �= Ma n � a= 3.4' a= 3.4N= 3.4' a= 3.4' l./ n Its a =3d a=Rd =Rd a=3d LL. < 0 H Ir o c H I= a V � O E co L z r� � W c n Q i �(��-^^��� \�/ t � o W U) 4--J � s O rr i • co Lo - i 1 (D 0 s Q0 t i LL. < 0 H Ir o O H I= a V � O Z W L z r� � W c n Q �(��-^^��� \�/ 0 o W U) 4--J o O rr U) r N Q0 I !III ,j 04 RIO # . ►' CHECKED DATE 10-29-13 SCALE AS r SHEET S -2 �I • II � LL- OF