12-120-005ELECTRICAL NOTES:
1.00 NOT SCALE ELECTRICAL DRAWINGS, REFER TO ARCHITECTURAL
PLANS AND ELEVATIONS FOR EXACT LOCATION OF ALL EQUIPMENT
CONFORM WITH OWNER OR REPRESENTATIVE.
2ALL WORK SHALL BE DONE IN ACCORDANCE WITH NATIONAL ELECTRICAL
CODE AND SHALL COMPLY WITH ALL LOCAL RULES AND ORDINANCES.
3MINIMUM WIRE SIZE SHALL BE 014 AWG, EXCLUDING CONTROL WIRING.
UNLESS OTHERWISE NOTED. ALL CONDUCTORS SHALL BE COPPER WITH THNN
OR THWN INSULATION.
4.OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS. CAST ALLOY
WITH THREADED HUBS IN WET OR DAMP LOCATIONS AND SPECIAL ENCLOSURES
FOR OTHER CLASSIFIED AREAS.
5.0ISCONNECT SWITCHES SHALL BE HI=, RATED. HEAVY DUTY, QUICK —MADE,
QUICK —BREAK ENCLOSURES AS REQUIRED BY EXPOSURE.
&MOTOR STARTERS SHALL BE MANUAL OR MAGNETIC, WITH OVERLOAD RELAYS
IN EACH HOT LEG.
i.IT IS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OF
CONSTRUCTION. THE CONTRACTOR 16 EXPECTED TO FURNISH AND INSTALL
ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM AND PROVIDE ALL REQUIRE-
MENTS NECESSARY FOR EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER.
B.ELECTRICAL SYSTEMS SHALL BE COMPLETE AND EFFECTIVELY GROUNDED AS
REQUIRED BY THE LATEST EDITION OF TH N.E.C.
SALL MATERIAL SHALL BE NEW AND BEAR UNDERWRITERS LABELS
WHERE APPLICABLE.
1 0ALL WORK SHALL BE PREFORMED BY A LICENSED ELECTRICAL CONTRACTOR
IN A FIRST CLASS WORKMAN LIKE MANNER THE COMPLETED SYSTEM SHALL
BE FULLY OPERATIVE, AND ACCEPTED BY ENGINEER/ARCHITECT.
11.4LL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE
WITH THE PROCESS OF CONSTRUCTION.
12.CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE
FROM DEFECTS FOR A PERIOD OF NOT LESS THAN ONE YEAR FROM DATE
OF ACCEPTANCE.
13.CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL
CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE
OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THERBY.
14ALL REQUIRED INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST
PUBLIC LIABILITY OF PROPERTY DAMAGE FOR THE DURATION OF THE WORK
15.CONTRACTORS SHALL PAY FOR ALL PERMITS, INSPECTIONS AND TESTING.
I &.THE ELECTRICAL INSTALLATION SHALL MEET ALL STANDARD REQUIREMENTS
OF POWER AND TELEPHONE COMPANIES.
11FURNISH AND INSTALL DISCONNECT SWITCHES AND WIRING FOR AIR
CONDITIONING SYSTEM AS PER MANUFACTURES RECOMMENDATIONS. CONTROLS
ARE TO BE SUPPLIED BY AIR CONDITIONING CONTRACTOR AND CONNECTED
BY ELECTRICAL CONTRACTOR.
1BALL RACEWAYS UNDERGROUND SHALL BE A MINIMUM OF 3/4" CONDUIT.
19ALL CIRCUIT BREAKERS, TWO AND THREE POLES, TO BE COMMON TRIP, NO
TIE HANDLES OR TANDENS WILL BE ACCEPTED.
20ALL FUSES UNLESS NOTED ON DRAWINGS SHALL BE CURRENT LIMITED FUSES
RATED FOR 200,000 A.I.C.
DEMAND FACTO R
FIRST 10,OOOW AT 100% 10,000W
REMAINDER AT 40% 9,445W
AC LOAD AT 100% 5,000W
TOTAL ADJUSTED LOAD 24,445W
24,445W / 240V = 102 AMPS
ELECT SI
ELECT ME
150A DISC
150 AMP CIRCUIT
BRKR PANEL W/
150A DISC SW
�U & 1 #6 CU
aiD CONDUIT
CU IN 1/2" CONDUIT
> -5/8" DIA X 10' GR. RODS
W PIPE
150 AMP
NEW LOAD CENTER 120/240 V - 11PH1 -rSN 3WER PANEL
CKT. No.
BREAKER
DESCRIPTION
BRANCH
CIRCUIT
LOAD
TRIP
POLE
FRAME
1,3
50
2
QO
AC #1 & HT STRIPS
2 #6 THW 3/4" C
5000W
2,4
50
2
QO
RANGE /OVEN
2 #6 THW 3/4" C
12000
5,7
30
2
QO
DRYER
2 #6 THW 3/4" C
5000
6,8
30
2
QO
WATERHEATER
2 #10 THW 1/2" C
3800
9
20
1
QO
MICROWAVE
2 #12 THW 1/2" C
1200
10
20
1
QO
REFRIGERATOR
2 #12 THW 1 /2" C
1500
11
20
1
QO
WASHER
2 #12 THW 1/2" C
1500
12
20
1
1 QO
DISHWASHER
2 #12 THW 1/2" C
800
13,14
20
1
QO
SMALL APPL
2 #12 THW 1/2" C
1500
15
20
1
QO
GFI BATH
2 #12 THW 1/2" C
1500
16
20
1
QO
GFI
2 #12 THW 1/2" C
1500
17 -22
15
1
QO
GEN LIGHTS
2 #14 THW 1/2" C
3312 °
23,24
1
QO
SPARES
2 #14 THW 1/2" C
SUBTOTAL 38612W
9100%
® 3W X 1104SF =3312W
EXIST LIVING AREA
NEW LIVING AREA
EL ' ECTRICAL-
FLOOR PLAN 1/4 �lmo
NOTES:
I. PROVIDE ARC FAULT RECEPTACLES AT ALL BEDROOMS.
2. PROVIDE GFI RECEPTACLES AT ALL EXISTING 4 NEW BATHS,
KITCHEN, GARAGE 4 EXTERIOR RECEPTACLES.
3. PROVIDE SMOKE DETECTORS INSIDE E OUTSIDE OF ALL
BEDROOMS, CONNECT TO BATH LIGHT CIRCUIT 4
INTERCONNECT ALL SMOKE DETECTORS IN SERIES.
OH ELECT SERVICE
(VERIFY LOCATION)
NO.
Lic. # AR0008374
• ,�Y I
ol• 0,10 pk ` ► ••
A01
aD USED, OR DISCLOSED WITHOUT
THE E)(PRESS WRITTEN OF
MICHAEL HURTAK ARCHITECT (c) 000
liii��ii
■���il
li��ii
■viii
■�I
liii��iiiii
■il
Iii
■�iiiii�iil
U.
co
UJ
i
0 U)
1
0 Z
i •
to
0
00
Lic. # AR0008374