Loading...
09-811R (2)-001t wie TIAI/, /1 A ' n„ L EXISTING A.C.U., TO REMAIN (EXISTING MAIN RESIDENCE)( FIELD VERIFY & MATCH EXIST. T.O.B.,, APPROX. ELEV. 81-1" A.F.F. REFER TO TIE -BEAM & FTG. SPLICE OR CONNECTION REQUIREMENTS SCALE:, 1/4"=l'-O" I FOUNDATION & MASOI�qRY PLAN STRUCTURAL NOTES I 1. ALL MASONRY BLOCK SHALL CONFORM TO THE REQUIREMENTS OF ASTM C90, FOR LOAD BEARING CONCRETE MASONRY. 2. ALL MORTAR SHALL BE A MINIMUM TYPE M OR S MO R. 3. ALL CONCRETE COLUMNS INTEGRAL W/ THE MASONRY SHALL BE CAST AFTER THE MASONRY HAS BEEN LAYED, SUCH THAT THE CONCRETE IS INTERLOCKED W/ THE MASONRY. 4. UNLESS SPECIFICALLY INDICATED OTHERWISE, PROVIDE DUR -O -WALL LADDER TYPE VERTICAL REINFORCING IN EVERY OTHER COURSE OF BLOCK (1 f" O.C., VERT.) 5. THE CONTRACTOR MUST BE CAREFUL TO PROVIDE CLE�NOUTS AT ALL BAR LOCATIONS TO ASSURE THAT ALL CELLS ARE VERTICALLY ALIGNED, WIDE CLEAR OF 1 LL MORTAR & OTHER DEBRIS. 6. REINF. MASONRY WALLS ARE USED THROUGHOUT THE (BUILDING, THE CONTRACTOR MUST INSURE QUALITY WORK & PROPER PLACEMENT OF ALL REINF., VERTICAL. WALL REINF. SHALL BE LAP SPLICED AT NO GREATER THAN 4' -0" O.C. AND SHALL BE LAPPED A MIN. OF 2' -0 ". CLEANOUTS MUST BE PROVIDED AT ALL LOCATIONS WHERE SPLICES OCCUR. REINF. IS TO BE PROPERLY PACED &CENTERED. CONCRETE STANDARD NOTES : 1. FOUNDATION & SLAB CONC. SHALL CONFORM TO THE REQUIREMENTS OF ACI 301, & SHALL ATTAIN A MIN. COMPRESSIVE STRENGTH IN 28 DAYS OF 2500 PSI., UNLESS OTHERWISE NOTED. 2. FOUNDATION & SLAB CONC. WHEN PLACED SHALL HA \E A SLUMP OF 5" PLUS OR MINUS 1". 3. ALL REINF. STEEL SHALL BE NEW STEEL CONFORMING TO ASTM A615, GRADE 60. I ALL ACCESSORIES SHALL CONFORM TO TYP. DETAILS SHOWN IN THE MANUAL OF "STANDARD PRACTICES FOR DETAILING REINF. STRUCTURES ", ACI -315. 4. ALL CONT. VERT. & HORZ. REINF. BARS IN FOOTINGS, FOUNDATIONS, WALL SLABSi & OTHER CONCRETE SHALL BE LAP- SPLICED 36 BAR DIA. OR V -6" MIN., WHICHEVER IS GREATER. ALL BARS AT' END OF CONT. FTG'S., BEAMS OR CONT. HORZ. ELEMENTS SHALL BE CONTINUED TO FAR SIDE OF INTERSECTING ELEMENTS. 5. WELDED WIRE MESH TO BE 6x6, W1.4xW1.4, STEEL LAP( JOINTS, PROVIDE DOUBLE LAYER BENEATH ALL BEARING WALLS, EXTEND FOR A DISTANCE OF 30" (TYP AROUND PERIMETER) 6. VAPOR BARRIER BENEATH SLABS TO BE 6 MIL. POLYETHYLENE. FOUNDATION NOTES : 1. FTG'S. SHALL BEAR ON CLEAN SAND FILL COMPACTED TO ACHIEVE A BEARING VALUE OF 2,500 P.S.F. I 2. SOILS SHALL BE TREATED FOR TERMITES PRIOR TO INSTALLATION OF BARRIER & POURING OF CONC., MATERIALS & INSTALLATION MUST COMPLY W/ ALL GOVERNING CODES & REGULATIONS (PROVIDE MIN. 2 YR. WARRANTY) 3. AT ALL STEPPED FTG'S. (FTG. TRANSITIONS), ADD 45' DEGREE BENT #5 "Z" BARS LAP FTG. STEEL 30" MIN. EACH END (AS APPLICABLE, SEE PLAN) 4. REMOVE ALL TOP -SOIL, ROOTS & SURFACE DELETERIOUS MATTER. OWNER TO BE RESPONSIBLE FOR SOIL INVESTIGATION, FILL MATERIAL SHALL BE CLEAN WELL GRADED SAND, PLACED IN LIFTS OF NOT MORE THAN 1' -0" & COMPACTED TO ACHIEVE A BEARING VALUE OF 2,500 P.S.F.,, TERMITE TREAT ALL FILL PRIOR TO ANY CONC. PLACEMENT (MAINTAIN CERTIFICATION STATEMENT FOR INSPECTION) I BEAM SCHEDULE: T.B. -1 = PROVIDE 8 "02" CONC. TIE BM. W/4 #5 BARS CONT. PROVIDE #3 TIES, 4 ® 12" ® CORNERS & BALANCE ® 48 ", MIN. 2 #5, 5' CORNER BARS BENT 30" EACH WAY (TYP.), T.O.B. EL. 8--l- A.F.F. PERIM. RESIDENCE TIE BEAM, FIELD VERIFY & MATCH EXIST. COLUMN SCHEDULE : C -1 = (1) #5 BAR VERT., IN CONC. FILLED CELL 0 48 "O.C. & ALONG ECH. SIDE OF ALL OPENINGS (TYP., THROUGHOUT) 12" C -2 = 8 "x12" CONC. REINF. COLUMN W /(4) #5 BARS VERT. 8" & #3 TIES ® 8-O.C. (UNLESS PLAN INDICATES OTHERWISE) 12" a12" C -3 = 12 "x12" CONC. COLUMN BLOCK W /(4) #5 BARS VERT. & #3 TIES 0 8-O.C. (UNLESS PLAN INDICATES OTHERWISE) EXT. WALLS MASONRY : (UNIT MASONRY DESIGN) 1. THE DESIGN OF THE ENG. UNIT MASONRY IS IN ACCORDANCE W/ ACI- 530- 93 /ASCE 5- 92/TMS. 402 -92. 2. A SPECIAL INSPECTOR SHALL BE USED FOR THE INSPECTION OF ALL REINF. UNIT MASONRY WALLS, A LETTER OF INTENT SHALL BE SUPPLIED TO THE BLDG. DEPT. PRIOR TO PLAN APPROVAL & PERMIT. GENERAL REINF. NOTES : FOR WINDOW & DOOR OPENINGS PROVIDE FILLED BLOCK CELL W/ 1 #5 BAR EACH SIDE (FOR ALL OPENINGS 3' to 6') REFER TO STRUCTURAL & CONC. GENERAL NOTES FOR MIN. REQUIREMENTS UNLESS PLAN INDICATES OTHERWISE. DUNG. FAU (SEE DETAIL) BTM. REINF. IN PATIO TIE -BM. TO BE (2) #7 BARS BTM. & (2 #5 BARS TOP„ TYP. ALONG FULL PERIM. � �- - - -� c„ 1011vi. wL11141 . Div 1 niiv TIE -BM. TO BE 2 #7 BARS BTM. & (2� 5 BARS TOP„ TYP. ALONG FULL PERIM. USE & OCCUPANCY CLASSIFICATION : RESIDENTIAL, GROUP "R" (R -3), F.B.C. SECTION 310 CLASSIFICATION OF WORK : ALTERATION, LEVEL -2, F.B.C. SECTION 304 3BD. /2BTH. ADDITION = 2183.00 S.F. O.A. GENERAL CONDITION & PLAN NOTES : 1. CONTRACTOR TO FIELD VERIFY ALL BLDG. DIMENSIONS, MASONRY OPENINGS & ELEVATIONS, PRIOR TO CONSTRUCTION OR FORM -WORK, ANY CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER. 2. ALL EXIST. CONDITIONS HAVE BEEN PREPARED FROM THE MOST RELIABLE INFORMATION AVAILABLE TO THE ENGINEER, CONTRACTOR SHALL VERIFY ALL EXIST. CONDITIONS PRIOR TO CONSTRUCTION. 3. WALL REINF. REMOVED FROM DOOR & WINDOW LOCATIONS FOR PLAN CLARITY (CONTRACTOR TO VERIFY ALL SILL HGT'S. & JAMB ELEVATIONS PRIOR TO POUR) J Z O 1- D O Q Q O CO M BTM. REINF. IN PATIO TIE -BM. TO BE �)5 #7 BARS B M. & (2 BARS TOP,, TYP. ALONG FULL PERIM. EXISIING BEAM. DOORIWINDOW SCHEDULE: WINDOWS : SIZE MASONRY (R /0.) NAME MARK WIDTH HGT. WIDTH HGT REMARKS - _A S.H. #22 1 37" 26" 37 3/4" 27" SINGLE - HUNG„ SHUTTERS REQ'D. 05 -21 -11 (DOOR) - N.O.A. NO. 08- 0527.15, EXP. DATE 07 -11 -12 (WINDOW) � S.H. #23 2 37" 38 3/8" 37 3/4 ". 39 3/8" SINGLE - HUNG„ SHUTTERS REQ'D. N 00 U O U) Ln S.H. #24 1 3 1 37" 50 5/8- 37 3/4" 51 5/8- 1 SINGLE - HUNG„ SHUTTERS REQ'D. DOORS NAME MARK WIDTH SIZE HGT. MASONRY (R /O.) WIDTH HGT. REMARKS 3068 A 36" 80" 41 1 2" 821/4- EXT. FR. IMPACT DRS. O O� u U 0 O Q N W O ♦'�^ V♦ s a-. A� In (BASED ON ASCE 7 -05, 146mph. WIND LOAD, EXPOSURE "C ") - N.O.A. NO. 05- 1215.01, EXP. DATE 05 -21 -11 (DOOR) - N.O.A. NO. 08- 0527.15, EXP. DATE 07 -11 -12 (WINDOW) NEW CONCRETE BEAM, SEE SCHEDULE FOR REINF'G. DRILL & EPDXY 4 - #5 DOWELS x 36" LONG, W/ 6" MIN. EMBEDMENT. USE C -100 HILTI EPDXY, TYPICAL. 1. THIS DETAIL IS WHEN A NEW BEAM ABUTS AND /OR CONNECTS TO AN EXISTING BEAM. EXISTING BEAM TO REMAIN. TIE -BEAM CONNECTION DETAIL SCALE: N.T.S. BLOCK -UP OF EXIST. OPENING SCALE: N.T.S. RTER DOWEL 18 1G. TO EXIST. CONC. TOP & BTM. VITH BLOCK, PROVIDE ,AUGE DOR -O -WALL OTHER COURSE. >CK FILLED CELLS OF OPENING AR VERT. FROM CONC. FTG. F EXIST. TIE -BM. NG 4RY WALL MAIN. IR IN -FILL LOCATIONS : SH W/1 "x2"WD. FURRINGS 0 16 "O.C. L INSUL. & 1/2" GYP. WALLBOARD ISHED W/ 5/8" STUCCO COAT TO MATCH ENCE DETAIL IS FOR CLOSING AN EXIS ?APgFING. _OCATIONS MgYW F SOU pEPT. BUI�DIF STRUCYURAL CT10N ti�ap -CNED REVISIONS BY 10- 15 -09, REV. PER STRUCT. CW. 01- 12 -10, REV. PER FIELD lCW. joB AU -0943 SHT S-1 mmma U _ rn pp 0. O LL U "' Z Z O wa 0 moo_ 0 ran L L. V ♦ Q ow� ryui .3 Z W w Cn Uws z� wJ`5 DON w ry C1 a]C4 " . Y �m ocn J a= DATE AUG., 2009 SCALE 1/4"=l'- 0" BY C.R.W. joB AU -0943 SHT S-1 mmma U _ rn pp � Q r N r-- V N 00 U O U) Ln V) PO M K) cN0 \ c" -L L e- Cfl 'L L� E o a� Z O O� u U 0 O Q N W O ♦'�^ V♦ s a-. A� In �cno C 0 T 0 Q) H U C1 a]C4 " . Y �m ocn J a= DATE AUG., 2009 SCALE 1/4"=l'- 0" BY C.R.W. joB AU -0943 SHT S-1 mmma