Loading...
09-811-022EXISTING 24' -0" 55' -6" 10' -0" COVERED PATIO W _(D Z U rn O Z W� M 0_ 0 0 u):2 Q Q _ L- I - - - - - - - - - - - - - - - - - - - - I TRAY CLG. LIMITS - - - - - - - - - - rz7l 200CFM. 200CFM. 1� C0W C�WC I I 12 "x6 ",3W. 12"x6 ",3W. C G I I I I I I 0 CONDENSING UNIT N O _00 I i 11 8„0 W v LL E o L 1 1 Z open patio O 1 1 e ist' g al es' en e 1 I I I i i i I � O CONCRETE PAD ♦♦�� V! I , � ?,Cj I ♦ 75 ( _ 0 o I I I o I I family room � I I -- - - - -- I dining room 1 I I w 4'A ,a . qa.: � Cu 00 a a., I I 218CFM. 25CFM. L U 12 "x6 ",3W. 25' -10" 12 "x6 ",3W. 1 ' I 28' -8' ISOMODE PAD (TYPICAL) - - -- e it en I I I I 1 9 I l I (2) #12 SHT. MTL. 1 1 1 1 8 "0 1 CONDENSING UNIT PLACED ON SCREWS TO A.C.U. L - -- - CJ I I I I ISOMODE PADS, & UNIT ANCHORED - - - I __ _ _ -- - _ I - - TRAY CLG. LIMITS L - -- - - - - -- ------------- - - - - -- AS INDICATED TO WITHSTAND 1 1 /4"x12", 8ga. I I I 1 80 HURRICANE FORCE WINDS. MTL. STRAP I I I I I ANCHOR TO SLAB AT UNIT (ALL CORNERS) MOUNTING POINTS. F - - - -- - ISOMODE PAD W_ d : b ro m 306E LOUVERED ) BI -F LD (R /A) i 19 "0 1/2, HILTI SLEEVE a u ' I I ANCHOR (3 PER S IDE) a -0 I 7 -2 „ 15 ,- 0" 8 „ 210CFM. "x6 ",3W. 4 I I ICFM. R/A 12 CONCRETE PAD I 4' 261 DR 8 "x4',3W. 4.5T. A.H.U. 8110 (15x15, S /A.) XH. UC OV HEA L 17-7 OOSi -- walk -in I I 2668 LOUVERED 8110 T- V. I I I BI -FOLD (R /A) (A ROX. 15') I I I E. H. I H.W.H.: 1 closet 1 5 - - - - - - - - I F.O. 0 N _ -- ----------- MAINTAIN 4'CLEAR., �? A PAD DETAIL I I R ER I L, C. 1 I ALL SIDES OF AHU. :X: --- --- - - - - -- I 12 "x o" I 1 _____________ w .C.U. DET I (FMC. 603.1.3) f �j R/A GRILL I - closet ex I,P- t it I, 6" R/A 1GRILL �' -- - - - - -- closet I 1 I I rn I I " I o N I 1 . I Lar- 9 I SUPPLY DUCT. SEE HVAC I I I 205CFM. I I 190CFM. I' n 248CFM. SUPPLY PLENUM PLAN FOR SIZES. 91CFM. master 12 " x6',3W. i i 12' x6 ,3W. I bedroom 12"x 6 ",3W. I I I" 10"x6 ",3W. 6 "0 f I I 1 I Open patio � j bedroom N i- bedroom II e e 00 I r -- J I I 7' -6" s 18' -0" I I 1 1' -O" ' -0" ° 12' -0" FIN. CLG. II e e 0 1 E. F. EXHAUST FAN I I EXHAUST F N _0_ I 4"0 DUCT TO 73CFM. 8%4",3W 1 I I I Q_ 4% DUCT TO I E F. ROOF VENT CAP DOOR HEADER II II I ROOF VENT C P (TYP. ECH. BATH) I I I I I (TYP. ECH. BATH) - - - - - RETURN AIR THRU LOUVERED DOORS I I I I 3 /8 "LIQ ID, 11/8" SUCTION �jl}- 3/4" CONDENSATE LINE REFRIGERANT SUCTION I I I I (INSULA ED AS REQ'D.) (UNDERGROUND, 2" LEEVE) & LIQUID LINES. ELECTRIC HEAT SECTION UNIT MOUNTED AHU (TYPICAL) I / I CIRCUIT BREAKER SECURE, UNIT TO FLOOR STAND, 1 A.C.U. & THRU VIBRATION ISOLATORS. I EXISTING A.C.U., TO REMAIN � / CONC. PAD CONDENSATE DRAIN /TRAP o (EXISTING MAIN RESIDENCE) 1 I (SEE DETAIL) SEE PLUMBING DWG'S. 0 SECONDARY DRAIN (FLOAT SWITCH) L - - - EQUIPMENT SCHEDULE: OVERFLOW CONNECTION A.C.U. = RHEEM MFG., RASL- 060JEC OR EQUIV. ISOMODE PADS AT CORNERS ° - FILTER FRAME WITH FILTER A.H.U. = RHEEM MFG., RCFM- H *6024A * +RGFD- 09 *ZCM* OR EQUIV. UNIT NOTES FOR VIBRATION ISOLATION (TYP.) EQUIPMENT STAND & SUPPORTS 4.5 TON, 1867 CFM., 16.0 SEER, 10K.W. HT. STRIPS 1. PROVIDE UNIT MOUNTED CIRCUIT BREAKERS FOR AIR HANDLING UNITS. A.H.U. UNIT N BY BUILDER (FIELD COORD.) ARI. REF. NO. 3204481 2. PROVIDE ANTI -SHORT CYCLE TIMER FOR CONDENSING UNITS. AUXILIARY DRAIN PANS SHALL BE REQUIRED. SIZE & MAKE SHALL 3. PROVIDE PROGRAMMABLE TYPE THERMOSTATS FOR AIR HANDLING UNITS. MEET MIN. REQUIREMENTS OF THE F.M.C., M307.2.3, A SEPARATE o SENSIBLE COOLING 39200 BTUH. DRAIN LINE SHALL EXTEND FROM THE PAN TO A CONSPICUOUS a LATENT COOLING 16800 BTUH. 4. R -6 DUCTWORK. POINT & SERVE AS AN ALARM INDICATING THAT THE PRIMARY LINE a TOTAL COOLING 56000 BTUH. 5. USE LOUVERED DOOR FOR RETURN AIR. (CONDENSATE) IS RESTRICTED. CONDENSATE LINES SHALL BE TRAPPED FIN. FLR. ACTUAL AIR FLOW 1867 CFM. 6. PIPING: AS SPECIFIED BY UNIT MANUF. AIR FLOW FACTOR 0.044 CFM /BTUH. 3/8" LIQUID LINE NOTE: A/C CLOSET IS USED AS A R/A PLENUM, MATERIALS INSIDE INSULATED VALUES STATIC PRESSURE 0.00 IN H2O 1 -1/8" SUCTION LINE A.H.U. SHALL HAVE A CONDENSATE FLOAT SWITCH, TO CONTROL OVERFLOW THAT WILL AUTOMATICALLY SHUT DOWN THE A/C SYSTEM. THIS DEVICE PLENUM SPACES SHALL HAVE A 25/50 MAX. FLAME SPREAD AND SMOKE DEVELOPED RESPECTIVELY. PERIM. BLOCKWALL - R -5 LOAD SENSIBLE HT. RATIO 0.86 3/4" CONDENSATE SHALL BE CONNECTED TO THE SECONDARY DRAIN OUTLET ON THE A.H.U. ATTIC AREA = R -30 EXH. FANS (E.F.) = BROAN MODEL #QTRE1 10, 11 OCFM. EXH. FAN 1/2" INSULATION (BECKETT MODEL NO. 4NFW97, OR APPROVED EQUAL) W/ 4"0 DUCT V.T.R. (OR EQUAL) * VERIFY LINE SIZE REQUIREMENTS W/ MANUF. SPECIFICATIONS SCALE: 1/4"=11'-O" HVAC. PLAN A.H.U. CLOSET DETAIL 1. THE WORK THAT IS TO BE DONE UNDER THIS HEADING INCLUDES THE 8. INSULATION: 17. ALL EQUIPMENT AND MATERIALS SHALL BE GUARANTEED FOR A PERIOD FURNIHING OF ALL LABOR, MATERIALS AND EQUIPMENT, PERMITS, FEES, OF ONE YEAR. COMPRESSORS SHALL CARRY 5 YEAR FACTORY GUARANTEE. TO CONDENSATE INSPECTIONS, TESTS, INSURANCE, ETC., REQUIRED FOR THE COMPLETION OF PIPING - CONDENSATE PIPING AND REFRIGERATION SUCTION PIPING SHALL BE FURNISH 90 DAYS FREE SERVICE. DRAIN LINE A/C UNIT DRAIN THE AIR CONDITIONING, HEATING AND VENTILATION SYSTEMS SHOWN ON INSULATED WITH 3/4" FIRE RATED FLEXIBLE FOAM INSULATION. FINISHED CONNECTION DRAWINGS OR LISTED BELOW. WHERE EXPOSED WITH 2 COATS OF WHITE LATEX PAINT ALL AS PER THE 18. CONTRACTORS SHALL VERIFY SPACE CONDITIONS AND DIMENSIONS AND MANUFACTURER'S INSTRUCTIONS. SHALL COORDINATE WORK WITH ALL OTHER TRADES AT JOBSITE PRIOR TO SOUND INSULATED AIR FLOW 2. THE DRAWINGS ARE GENERALLY DIAGRAMATIC. THEY DO NOT SHOW EVERY FABRICATION AND INSTALLATION OF DUCTWORK. THE CONTACTOR SHALL BE HOUSING BEND, OFF -SET, ELBOWS OR OTHER FITTINGS WHICH MAY BE REQUIRED FOR 9. FILTERS: RESPONSIBLE FOR THE FULL COORDINATION OF THIS WORK WITH THAT OF ALL THE INSTALLATION IN THE SPACE ALLOCATED, OR FOR COORDINATION WITH OTHER TRADES. NOTE: OTHER TRADES. A. PROVIDE TWO SETS OF TEMPORARY FIBERGLASS THROWAWAY FILTERS OF INSTALLATION OF PIPING TO CLEAR EXHAUST DUCT THE SAME THICKNESS AS FINAL FILTERS FOR USE DURING CONSTRUCTION. 19. REFRIGERANT PIPING SHALL BE TYPE "L" COPPER TUBING WITH WROUGHT FILTER PULL OUT AREA & SERVICE 3. DRAWINGS ARE NOT TO BE SCALED. UNLESS SPECIFIC DIMENSIONS ARE SHOWN, THE ARCHITECTURAL AND /OR STRUCTURAL DRAWINGS, AND SITE B. PROVIDE TWO COMPLETE SETS OF FINAL FILTERS. COPPER FITTINGS AND SILVER SOLDERED JOINTS. PIPING SHALL BE SIZED REMOVABLE PANELS ADJUSTABLE CENTRIFUGAL CONDITIONS SHALL GOVERN EXACT LOCATION OF MECHANICAL EQUIPMENT AND AND INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS FOR MOUNTING FAN INSIDE APPURTENANCES. 10. TESTING: EQUIPMENT LOCATIONS SHOWN. FLANGE HOUSING 4. DUCTWORK: A. BALANCE AIR SYSTEM TO DELIEVER QUANTITIES AT EACH OUTLET WITHIN 20. ALL FAN DRIVES SHALL BE ADJUSTED TO DELIVER THE SPECIFIED CFM AGAINST THE ACTUAL STATIC PRESSURE OF THE INSTALLATION. 107 USING A.A.B.C. PROCEDURES AND TESTS. A. SUPPLY AND RETURN AIR DUCTS, SHALL BE CONSTRUCTED OF 1" THICK STANDARD DUTY FIBERGLASS BOARD FLAMEPROOF REINFORCED 21. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF ALUMINUM FACED COVER IN ACCORDANCE WITH N.F.P.A. NO.90 AS 11. VIBRATION ISOLATION: ALL EQUIPMENT AS PER MANUFACTURER'S THE FLORIDA BUILDING CODE, AND ALL LOCAL MUNICIPAL & COUNTY CODES MANUFACTURED BY OWENS- CORNING, DUCTWORK SHALL BE FABRICATED AND RECOMMENDATIONS OR AS SPECIFIED ON DRAWINGS. AND ORDINANCES HAVING JURISDICTION. INSTALLED ACCORDING TO MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. USE 1 1/2 INCH THICK R =6.0 DUCTBOARD IN 12. VERIFY ALL VOLTAGES WITH ELECTRICAL CONTRACTORS BEFORE ORDERING 22. NAMING OF ACCEPTABLE MANUFACTURERS DOES NOT RELIEVE THE REMOVABLE AIR FLOW TRUSS /ATTIC SPACE. ANY EQUIPMENT. CONTRACTORS FROM COMPLYING WITH ALL THE BASIS OF DESIGN CONDENSATE LINE RUNS THROUGH ALUM. CEILING REQUIREMENTS SHOWN ON CONTRACT DRAWINGS AND /OR SPECIFICATION. SLAB SYSTEM TO EXT. WALL GRILLE B. FLEXIBLE DUCTWORK SHALL BE SELF SUPPORTING ALUMINUM CONSTRUCTION 13. AIR DISTRIBUTION, AIR HANDLING UNITS, FANS, AND AIR COOLED EXTEND CONDENSATE 12" AND INSULATED WITH BLANKET TYPE INSULATION WITH EXTERIOR VAPOR CONDENSING UNITS SHALL BE AS SCHEDULED ON THE DRAWINGS OR EQUAL. 23. AIR DISTRIBUTION SHALL BE OF EXTRUDED ALUMINIM CONSTRUCTION AS THRU EXT. BLOCKWALL BARRIER WITH R =4.2 (R =6.0 BELOW ROOF AREAS), U.L. LISTED CLASS I AIR MANUFACTURED BY TITUS OR EQUAL FINISH SHALL BE OFF -WHITE (SEE PLAN) 3/4" CONDENSATE LINE, ALONG EXT. WALL DUCT, NFPA 90A APPROVED. THERMOFIN OR APPROVED EQUAL. 14. SUBMIT SHOP DRAWINGS OF ALL MATERIALS, DUCTWORK AND EQUIPMENT FOR REVIEW PRIOR TO FABRICATION. 'A' CEILING DIFFUSER MODEL 250 -AA W/ O.B.D. Li 5. ALL DUCT ELBOWS SHALL BE FITTED WITH TURNING VANES. B SIDEWALL REGISTER MODEL 2 W/ O.B.D. CEILING FANS TO BE BROAN MODEL 684, 15. CONTROL: 'C' CEILING /WALL GRILLE MODEL 3FL. FL. FIN. GRADE FANS AS INDICATED OR APPROVED EQUAL ) 6. VENTILATION AND TOILET EXHAUST DUCTWORK SHALL BE CONSTRUCTED 90000 0000000 75 CFM � 2.5 SONES, .75 AMPS,120 -1 -60 OF GALV. FLEX -DUCT (OR EQUAL), CONSTRUCTED IN ACCORDANCE WITH A. ALL ELECTRICAL WIRING AND CONDUIT SHALL BE PROVIDED BY THE FURNISH AIR DISTRIBUTION DEVICES COMPLETE WITH FRAME FOR DRY WALL 0 0 ° °° o °o° INTERLOCK WITH LIGHT SWITCH THE LATEST A.S.H.R.A.E. GUIDE AND S.M.A.C.N.A. RECOMMENDATIONS. ELECTRICAL CONTRACTOR. CEILING INSTALLATION. ��0006 00 0 ALL EXHAUST THROUGH ROOF SHALL TERMINATE MINIMUM OF 8 ABOVE o 0000060000 FINISHED ROOF IN ACCORDANCE WITH F.B.C. REQUIREMENTS. 16. THERMOSTATS SHALL BE HEAT -COOL TYPE WITH FAN AND SELECTOR ALL EXHAUST DUCTS THROUGH ROOF SWITCHES ON SUB BASE. LOCATED WHERE INDICATED ON PLANS AS PER L24%24"x24" SHALL TERMINATE A MINIMUM OF 8" 7. PROVIDE ACCESS PANELS IN ALL WALL AND CEILINGS FOR ALL VALVES, SPECIFIED UNIT MANUFACTURER. DP. FRENCH DRAIN " ABOVE FINISHED ROOF DAMPERS, CONTROL DEVICES, ETC. ACESS PANELS SHALL BE MILCOR FLUSH W/3/4 -1 1/2" WASHED TYPE. ROCK. OPEN ® BOTTOM GENERAL NOTES & SPECIFICATIONS CONDENSATE DETAILS EXHAUST FAN DETAIL REVISIONS BY a r 0. O LL W _(D Z U rn O Z W� M 0_ 0 0 u):2 Q Q _ w 1� C0W z w a C�WC � C G WJ �' 0 O N O _00 Ln ■ W v LL E o W Z 3: _(D rn 0 N �z(nnu)n � � (0 v 00 v ' � L L O _00 Ln ■ Qi v LL E o Z N O 0 _0 ° Q W � O _ ♦♦�� V! , � ?,Cj L0 ♦ 75 ( _ 0 o � L C 0 '- � Cu 00 Jc U w _�1 ;qvN '- ,OY w l`s X Uli' DATE AUG., 2009 SCALE 11/4"=14-0" BY C.R.W. x JOB AU -09.43 SHT AC- °�%'''"' .�4 ,3, •r4 N