09-811-022EXISTING 24' -0"
55' -6"
10' -0"
COVERED PATIO
W
_(D
Z
U
rn
O
Z
W�
M
0_
0
0
u):2
Q
Q
_
L-
I
- - - - - - - - - - - - - - - - - - - -
I TRAY CLG. LIMITS
- - - - - - - - - -
rz7l 200CFM.
200CFM.
1�
C0W
C�WC
I
I 12 "x6 ",3W.
12"x6 ",3W.
C
G
I I I
I I
I
0
CONDENSING UNIT
N
O _00
I
i 11 8„0
W
v LL E
o
L
1
1
Z
open patio
O
1 1 e ist' g al es' en e
1
I I
I i i
i
I
� O
CONCRETE PAD
♦♦��
V!
I
,
� ?,Cj
I
♦
75
( _
0 o
I I
I o
I I
family room
�
I I -- - - - --
I dining room
1 I I
w
4'A ,a . qa.:
�
Cu
00
a a.,
I
I 218CFM.
25CFM.
L
U
12 "x6 ",3W. 25' -10"
12 "x6 ",3W. 1 ' I 28' -8'
ISOMODE PAD (TYPICAL)
- - -- e it
en
I I I I
1
9 I l
I
(2) #12 SHT. MTL.
1 1
1 1 8 "0
1
CONDENSING UNIT PLACED ON
SCREWS TO A.C.U.
L
- -- - CJ I
I I I
ISOMODE PADS, & UNIT ANCHORED
- - -
I __ _ _
-- - _ I - - TRAY CLG. LIMITS
L - -- - - - - -- -------------
- - - - --
AS INDICATED TO WITHSTAND
1 1 /4"x12", 8ga.
I I I
1
80
HURRICANE FORCE WINDS.
MTL. STRAP
I I I I
I
ANCHOR TO SLAB AT UNIT
(ALL CORNERS)
MOUNTING POINTS.
F - - - -- -
ISOMODE PAD
W_
d
:
b ro m
306E LOUVERED
) BI -F LD (R /A)
i 19 "0
1/2, HILTI SLEEVE
a
u
' I
I
ANCHOR (3 PER S IDE)
a
-0 I 7 -2 „
15 ,- 0" 8 „
210CFM.
"x6 ",3W.
4
I
I
ICFM.
R/A
12
CONCRETE PAD
I
4' 261 DR
8 "x4',3W.
4.5T. A.H.U.
8110 (15x15, S /A.)
XH. UC OV HEA L 17-7
OOSi --
walk -in
I I 2668 LOUVERED 8110
T- V. I
I
I BI -FOLD (R /A)
(A ROX. 15') I
I I
E. H. I H.W.H.: 1 closet 1 5
- - - - - - - -
I
F.O. 0 N
_ --
-----------
MAINTAIN 4'CLEAR., �?
A PAD DETAIL
I I
R ER I L, C.
1 I
ALL SIDES OF AHU. :X: --- --- - - - - -- I 12 "x o"
I 1 _____________
w
.C.U.
DET I
(FMC. 603.1.3) f �j R/A GRILL
I - closet
ex
I,P-
t it I,
6" R/A 1GRILL
�' -- - - - - --
closet
I 1 I I rn I I
"
I o
N I 1
.
I
Lar-
9
I
SUPPLY
DUCT. SEE HVAC
I I
I
205CFM. I I 190CFM. I'
n
248CFM.
SUPPLY PLENUM PLAN FOR SIZES.
91CFM. master
12 " x6',3W. i i 12' x6 ,3W. I
bedroom
12"x 6 ",3W.
I
I I" 10"x6 ",3W. 6 "0 f
I I
1 I
Open patio
�
j bedroom N
i- bedroom
II e e 00 I r -- J I
I 7' -6" s 18' -0" I I 1 1' -O" ' -0"
° 12' -0"
FIN. CLG.
II e e
0 1 E. F. EXHAUST FAN
I I EXHAUST F N _0_
I 4"0 DUCT TO
73CFM.
8%4",3W
1 I
I I Q_ 4% DUCT TO
I E F.
ROOF VENT CAP
DOOR HEADER
II
II
I ROOF VENT C P
(TYP. ECH. BATH)
I
I I
I I (TYP. ECH. BATH)
- - - - -
RETURN AIR THRU
LOUVERED DOORS
I I I
I
3 /8 "LIQ ID, 11/8" SUCTION �jl}- 3/4" CONDENSATE LINE
REFRIGERANT SUCTION
I I I
I
(INSULA ED AS REQ'D.) (UNDERGROUND, 2" LEEVE)
& LIQUID LINES.
ELECTRIC HEAT SECTION
UNIT MOUNTED
AHU (TYPICAL)
I / I
CIRCUIT BREAKER
SECURE, UNIT TO FLOOR STAND,
1 A.C.U. &
THRU VIBRATION ISOLATORS.
I
EXISTING A.C.U., TO REMAIN � /
CONC. PAD
CONDENSATE DRAIN /TRAP
o
(EXISTING MAIN RESIDENCE) 1 I
(SEE DETAIL)
SEE PLUMBING DWG'S.
0
SECONDARY DRAIN (FLOAT SWITCH)
L - - -
EQUIPMENT SCHEDULE:
OVERFLOW CONNECTION
A.C.U. = RHEEM MFG., RASL- 060JEC OR EQUIV.
ISOMODE PADS AT CORNERS
° -
FILTER FRAME WITH FILTER
A.H.U. = RHEEM MFG., RCFM- H *6024A * +RGFD- 09 *ZCM* OR EQUIV. UNIT NOTES
FOR VIBRATION ISOLATION (TYP.)
EQUIPMENT STAND & SUPPORTS
4.5 TON, 1867 CFM., 16.0 SEER, 10K.W. HT. STRIPS
1. PROVIDE UNIT MOUNTED CIRCUIT BREAKERS FOR AIR HANDLING UNITS.
A.H.U. UNIT
N
BY BUILDER (FIELD COORD.)
ARI. REF. NO. 3204481
2. PROVIDE ANTI -SHORT CYCLE TIMER FOR CONDENSING UNITS.
AUXILIARY DRAIN PANS SHALL BE REQUIRED. SIZE & MAKE SHALL
3. PROVIDE PROGRAMMABLE TYPE THERMOSTATS FOR AIR HANDLING UNITS.
MEET MIN. REQUIREMENTS OF THE F.M.C., M307.2.3, A SEPARATE
o
SENSIBLE COOLING 39200 BTUH.
DRAIN LINE SHALL EXTEND FROM THE PAN TO A CONSPICUOUS
a
LATENT COOLING 16800 BTUH.
4. R -6 DUCTWORK.
POINT & SERVE AS AN ALARM INDICATING THAT THE PRIMARY LINE
a
TOTAL COOLING 56000 BTUH.
5. USE LOUVERED DOOR FOR RETURN AIR.
(CONDENSATE) IS RESTRICTED. CONDENSATE LINES SHALL BE TRAPPED
FIN. FLR.
ACTUAL AIR FLOW 1867 CFM.
6. PIPING:
AS SPECIFIED BY UNIT MANUF.
AIR FLOW FACTOR 0.044 CFM /BTUH.
3/8" LIQUID LINE
NOTE: A/C CLOSET IS USED AS A R/A PLENUM,
MATERIALS INSIDE
INSULATED VALUES
STATIC PRESSURE 0.00 IN H2O
1 -1/8" SUCTION LINE
A.H.U. SHALL HAVE A CONDENSATE FLOAT SWITCH, TO CONTROL OVERFLOW
THAT WILL AUTOMATICALLY SHUT DOWN THE A/C SYSTEM. THIS DEVICE
PLENUM SPACES SHALL HAVE A 25/50 MAX. FLAME SPREAD
AND SMOKE DEVELOPED RESPECTIVELY.
PERIM. BLOCKWALL -
R -5 LOAD SENSIBLE HT. RATIO 0.86
3/4" CONDENSATE
SHALL BE CONNECTED TO THE SECONDARY DRAIN OUTLET ON THE A.H.U.
ATTIC AREA =
R -30 EXH. FANS (E.F.) = BROAN MODEL #QTRE1 10, 11 OCFM. EXH. FAN 1/2" INSULATION
(BECKETT MODEL NO. 4NFW97, OR APPROVED EQUAL)
W/ 4"0 DUCT V.T.R. (OR EQUAL)
* VERIFY LINE SIZE REQUIREMENTS W/ MANUF. SPECIFICATIONS
SCALE: 1/4"=11'-O"
HVAC. PLAN
A.H.U. CLOSET
DETAIL
1. THE WORK THAT IS TO BE DONE UNDER THIS HEADING INCLUDES THE
8. INSULATION:
17. ALL EQUIPMENT AND MATERIALS SHALL BE GUARANTEED FOR A PERIOD
FURNIHING OF ALL LABOR, MATERIALS AND EQUIPMENT, PERMITS, FEES,
OF ONE YEAR. COMPRESSORS SHALL CARRY 5 YEAR FACTORY GUARANTEE.
TO CONDENSATE
INSPECTIONS, TESTS, INSURANCE, ETC., REQUIRED FOR THE COMPLETION OF
PIPING - CONDENSATE PIPING AND REFRIGERATION SUCTION PIPING SHALL BE
FURNISH 90 DAYS FREE SERVICE.
DRAIN LINE A/C UNIT DRAIN
THE AIR CONDITIONING, HEATING AND VENTILATION SYSTEMS SHOWN ON
INSULATED WITH 3/4" FIRE RATED FLEXIBLE FOAM INSULATION. FINISHED
CONNECTION
DRAWINGS OR LISTED BELOW.
WHERE EXPOSED WITH 2 COATS OF WHITE LATEX PAINT ALL AS PER THE
18. CONTRACTORS SHALL VERIFY SPACE CONDITIONS AND DIMENSIONS AND
MANUFACTURER'S INSTRUCTIONS.
SHALL COORDINATE WORK WITH ALL OTHER TRADES AT JOBSITE PRIOR TO
SOUND INSULATED
AIR FLOW
2. THE DRAWINGS ARE GENERALLY DIAGRAMATIC. THEY DO NOT SHOW EVERY
FABRICATION AND INSTALLATION OF DUCTWORK. THE CONTACTOR SHALL BE
HOUSING
BEND, OFF -SET, ELBOWS OR OTHER FITTINGS WHICH MAY BE REQUIRED FOR
9. FILTERS:
RESPONSIBLE FOR THE FULL COORDINATION OF THIS WORK WITH THAT OF ALL
THE INSTALLATION IN THE SPACE ALLOCATED, OR FOR COORDINATION WITH
OTHER TRADES.
NOTE:
OTHER TRADES.
A. PROVIDE TWO SETS OF TEMPORARY FIBERGLASS THROWAWAY FILTERS OF
INSTALLATION OF PIPING TO CLEAR
EXHAUST DUCT
THE SAME THICKNESS AS FINAL FILTERS FOR USE DURING CONSTRUCTION.
19. REFRIGERANT PIPING SHALL BE TYPE "L" COPPER TUBING WITH WROUGHT
FILTER PULL OUT AREA & SERVICE
3. DRAWINGS ARE NOT TO BE SCALED. UNLESS SPECIFIC DIMENSIONS ARE
SHOWN, THE ARCHITECTURAL AND /OR STRUCTURAL DRAWINGS, AND SITE
B. PROVIDE TWO COMPLETE SETS OF FINAL FILTERS.
COPPER FITTINGS AND SILVER SOLDERED JOINTS. PIPING SHALL BE SIZED
REMOVABLE PANELS
ADJUSTABLE
CENTRIFUGAL
CONDITIONS SHALL GOVERN EXACT LOCATION OF MECHANICAL EQUIPMENT AND
AND INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS FOR
MOUNTING
FAN INSIDE
APPURTENANCES.
10. TESTING:
EQUIPMENT LOCATIONS SHOWN.
FLANGE
HOUSING
4. DUCTWORK:
A. BALANCE AIR SYSTEM TO DELIEVER QUANTITIES AT EACH OUTLET WITHIN
20. ALL FAN DRIVES SHALL BE ADJUSTED TO DELIVER THE SPECIFIED CFM
AGAINST THE ACTUAL STATIC PRESSURE OF THE INSTALLATION.
107 USING A.A.B.C. PROCEDURES AND TESTS.
A. SUPPLY AND RETURN AIR DUCTS, SHALL BE CONSTRUCTED OF 1"
THICK STANDARD DUTY FIBERGLASS BOARD FLAMEPROOF REINFORCED
21. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF
ALUMINUM FACED COVER IN ACCORDANCE WITH N.F.P.A. NO.90 AS
11. VIBRATION ISOLATION: ALL EQUIPMENT AS PER MANUFACTURER'S
THE FLORIDA BUILDING CODE, AND ALL LOCAL MUNICIPAL & COUNTY CODES
MANUFACTURED BY OWENS- CORNING, DUCTWORK SHALL BE FABRICATED AND
RECOMMENDATIONS OR AS SPECIFIED ON DRAWINGS.
AND ORDINANCES HAVING JURISDICTION.
INSTALLED ACCORDING TO MANUFACTURER'S INSTRUCTIONS AND
RECOMMENDATIONS. USE 1 1/2 INCH THICK R =6.0 DUCTBOARD IN
12. VERIFY ALL VOLTAGES WITH ELECTRICAL CONTRACTORS BEFORE ORDERING
22. NAMING OF ACCEPTABLE MANUFACTURERS DOES NOT RELIEVE THE
REMOVABLE AIR FLOW
TRUSS /ATTIC SPACE.
ANY EQUIPMENT.
CONTRACTORS FROM COMPLYING WITH ALL THE BASIS OF DESIGN
CONDENSATE LINE RUNS THROUGH
ALUM. CEILING
REQUIREMENTS SHOWN ON CONTRACT DRAWINGS AND /OR SPECIFICATION.
SLAB SYSTEM TO EXT. WALL
GRILLE
B. FLEXIBLE DUCTWORK SHALL BE SELF SUPPORTING ALUMINUM CONSTRUCTION
13. AIR DISTRIBUTION, AIR HANDLING UNITS, FANS, AND AIR COOLED
EXTEND CONDENSATE 12"
AND INSULATED WITH BLANKET TYPE INSULATION WITH EXTERIOR VAPOR
CONDENSING UNITS SHALL BE AS SCHEDULED ON THE DRAWINGS OR EQUAL.
23. AIR DISTRIBUTION SHALL BE OF EXTRUDED ALUMINIM CONSTRUCTION AS
THRU EXT. BLOCKWALL
BARRIER WITH R =4.2 (R =6.0 BELOW ROOF AREAS), U.L. LISTED CLASS I AIR
MANUFACTURED BY TITUS OR EQUAL FINISH SHALL BE OFF -WHITE
(SEE PLAN) 3/4" CONDENSATE LINE, ALONG EXT. WALL
DUCT, NFPA 90A APPROVED. THERMOFIN OR APPROVED EQUAL.
14. SUBMIT SHOP DRAWINGS OF ALL MATERIALS, DUCTWORK AND EQUIPMENT
FOR REVIEW PRIOR TO FABRICATION.
'A' CEILING DIFFUSER MODEL 250 -AA W/ O.B.D.
Li
5. ALL DUCT ELBOWS SHALL BE FITTED WITH TURNING VANES.
B SIDEWALL REGISTER MODEL 2 W/ O.B.D.
CEILING FANS TO BE BROAN MODEL 684,
15. CONTROL:
'C' CEILING /WALL GRILLE MODEL 3FL.
FL.
FIN. GRADE
FANS AS INDICATED OR APPROVED EQUAL )
6. VENTILATION AND TOILET EXHAUST DUCTWORK SHALL BE CONSTRUCTED
90000 0000000
75 CFM � 2.5 SONES, .75 AMPS,120 -1 -60
OF GALV. FLEX -DUCT (OR EQUAL), CONSTRUCTED IN ACCORDANCE WITH
A. ALL ELECTRICAL WIRING AND CONDUIT SHALL BE PROVIDED BY THE
FURNISH AIR DISTRIBUTION DEVICES COMPLETE WITH FRAME FOR DRY WALL
0 0 ° °° o °o°
INTERLOCK WITH LIGHT SWITCH
THE LATEST A.S.H.R.A.E. GUIDE AND S.M.A.C.N.A. RECOMMENDATIONS.
ELECTRICAL CONTRACTOR.
CEILING INSTALLATION.
��0006 00 0
ALL EXHAUST THROUGH ROOF SHALL TERMINATE MINIMUM OF 8 ABOVE
o 0000060000
FINISHED ROOF IN ACCORDANCE WITH F.B.C. REQUIREMENTS.
16. THERMOSTATS SHALL BE HEAT -COOL TYPE WITH FAN AND SELECTOR
ALL EXHAUST DUCTS THROUGH ROOF
SWITCHES ON SUB BASE. LOCATED WHERE INDICATED ON PLANS AS PER
L24%24"x24"
SHALL TERMINATE A MINIMUM OF 8"
7. PROVIDE ACCESS PANELS IN ALL WALL AND CEILINGS FOR ALL VALVES,
SPECIFIED UNIT MANUFACTURER.
DP. FRENCH DRAIN
"
ABOVE FINISHED ROOF
DAMPERS, CONTROL DEVICES, ETC. ACESS PANELS SHALL BE MILCOR FLUSH
W/3/4 -1 1/2" WASHED
TYPE.
ROCK. OPEN ® BOTTOM
GENERAL NOTES & SPECIFICATIONS
CONDENSATE DETAILS
EXHAUST FAN
DETAIL
REVISIONS BY
a
r
0.
O
LL
W
_(D
Z
U
rn
O
Z
W�
M
0_
0
0
u):2
Q
Q
_
w
1�
C0W
z
w
a
C�WC
�
C
G
WJ
�'
0
O
N
O _00
Ln
■
W
v LL E
o
W
Z
3:
_(D
rn
0
N
�z(nnu)n
�
� (0
v
00
v
' � L
L
O _00
Ln
■
Qi
v LL E
o
Z
N
O
0 _0
° Q
W
� O
_
♦♦��
V!
,
� ?,Cj
L0
♦
75
( _
0 o
�
L
C
0
'-
�
Cu
00
Jc
U
w _�1
;qvN
'- ,OY w
l`s X Uli'
DATE AUG., 2009
SCALE 11/4"=14-0"
BY C.R.W.
x
JOB AU -09.43
SHT AC- °�%'''"'
.�4
,3, •r4
N