09-811-020EXISTING 24' -0" a � L_ EXISTING A.C.U., TO REMAIN (EXISTING MAIN RESIDENCE) EXIST. LOAD DEMAND 200A 120/240 - 60Hz - 1 P SERVICE WATTS 945 SQ. FT. @ 3w 2835 EXIST. REFRIG. 1000 EXIST. OVEN /BURNERS 12000 EXIST. SMALL APPL. 1500 EXIST. SMALL APPL. 1500 EXIST. H.W.H. 4500 EXIST. A/C (CENTRAL) 10000 EXIST. WASHER 5000 EXIST. DRYER 1500 TOTAL EXISTING = 39,835 SCALE: 1/4"=l'-O" INCOMING 3 -2/0 THWN Cu TRIP POLES WIRE COND. 15 1 #14 ROMEX 20 1 #12 20 2 #8 20 1 #12 20 1 #12 30 2 #10 50 2 #6 20 1 #12 30 2 #10 ELECT. /LIGHTING PLAN 1. CONTRACTOR SHALL VERIFY WITH FP &L THE LOCATION OF SERVICE AND SHALL LOCATE METER AND PANELS AS REQUIRED. 2. ALL WIRE SHALL BE THHN COPPER, UNLESS NOTED OTHERWISE. 3. WHERE REQUIRED BY OTHER CODES, SERVICE AND FEEDER CONDUCTORS SHALL BE COPPER OF EQUAL AMPACITY. 4. ALL BRANCH CIRCUITS IN RACEWAY OR NON METALLIC SHEATHED CABLE. 5. COORDINATE RACEWAY INSTALLATIONS WITH OTHER TRADES PRIOR TO CONSTRUCTION. 6. VERIFY ALL CONDUCTORS AND BREAKERS WITH EQUIPMENT MANUFACTURER SPECIFICATIONS. 7. PROVIDE DISCONNECT SWITCH OF SIZE AS REQUIRED BY LOAD AND UNITS. 8. PROVIDE NON- FUSIBLE GENERAL DUTY SAFETY SWITCHES AT A/C EQUIPMENT AND AT PUMPS NOT VISABLE FROM CIRCUIT BREAKER PANEL AND AS PER MANUFACTURER RECOMMENDATIONS. 9. PROVIDE GFI BREAKERS FOR ALL BATHROOMS, GARAGE EXTERIOR OULETS AS SHOWN ON PLANS. 10. ELECTRICAL FIXTURES, TRIM AND APPLIANCES SHALL BE UL APPROVED AND AS SELECTED BY OWNER. 11. PROVIDE PRE -WIRED TELEPHONE OUTLETS AS SHOWN ON ELECTRICAL PLAN. PROVIDE PRE -WIRED T.V. OUTLETS FOR CABLE AS SHOWN ON PLANS. 12. DEDICATED CIRCUITS SHALL HAVE NO MORE THAN 6 DUPLEX RECEPTACLES. 13. IN KITCHENS, DINING ROOMS AND BATHROOMS, RECEPTICAL OUTLETS FOR COUNTER SPACES SHALL BE GFI PROTECTED ACCORDING TO NEC 210 -8(a). 14. ALL CLOSET LIGHTING SHALL COMPLY WITH NEC SEC. 410.8. 15. SMOKE DETECTORS SHALL BE CONNECTED TO KITCHEN OR BATH LIGHTING CIRCUITS AHEAD OF SWITCH AND HAVE SELF CONTAINED BATTERY BACK -UP. DETECTORS SHALL BE TANDEM WIRED SO ALL DETECTORS SOUND SIMULTANEOUSLY, OPTIONAL CALCS.: TOTAL WATTS LESS A/C 1 ST 10,000 ® 100% BAL 19,835 0 40% A/C WATTS PER EX. PNL. "B "= 39,835 = 29,835 = 10,000 7,934 10,000 27,934/ 240 = 116.4 AMPS 16. PREWIRE FOR GARAGE DOOR OPENER SENSOR. (NOTE AS APPLICABLE) 17. ALL OUTLET BOXES FOR RECEPTICALS, TV ANTENNAS, OR TELEPHONE JACKS, ETC. IN RATED WALLS MUST BE METAL OR U.L. RATED FOR USE IN ONE HOUR FIRE RATED CONSTRUCTION. 18. ALL ELECTRICAL WORK TO CONFORM TO THE NATIONAL ELECTRICAL CODE AND NFPA 70. 19. ELECTRICAL CONTRACTOR TO CONFORM WITH BELLSOUTH REQUIREMENTS FOR TELEPHONE EQUIPMENT INSTALLATION 20. CO- ORDINATE ALL CONDUIT RUNS AND EQUIPMENT INSTALLATION WITH OTHER TRADES TO AVOID CONFLICTS PRIOR TO FABRICATION, INSTALLATION, AND ERECTION. 21. ELECTRICAL CONTRACTOR TO VERIFY ALL HVAC UNIT CONNECTIONS WITH HVAC CONTRACTOR PRIOR TO INSTALLATION. ALL A/C UNITS TO HAVE INTERNAL BREAKERS. 22. ALL METERS, METER CENTERS AND DISCONNECTS TO BE APPROVED BY FP &L. 23. MINIMUM WIRE SIZE SHALL BE #14 AWG INSULA11ON FOR WIRE SIZE #6 AND SMALLER SHALL BE THWN #4 AND LARGER SHALL BE THHN. ALL CONDUCTORS #10 AND SMALLER MAY BE SOLID #3 AND LARGER SHALL BE STRANDED ( ROMEX MAY BE USED WHERE APPROVED.) 24. CIRCUIT LOCATION AND LOAD DATA ARE BASED UPON INFORMATION GIVEN TO THE ARCHITECT AT TIME OF DESIGN. CONTACTOR SHALL VERIFY ALL EQUIPMENT AND PANEL SIZES AND SHALL PROVIDE CIRCUITS AND ROUTING OF CONDUITS TO SUIT JOB CONDTIONS. 25. ALL 120V 1 PHASE 15A AND 20A GARAGE AND EXTERIOR RECEPTACLES SHALL HAVE GROUND FAULT INTERRUPTER (GFI) PROTECTION. 26. USE GFI CIRCUIT BREAKERS ON GFI RECEPTACLES. 27. PROVIDE W.P. DISCONNECTS AT ALL A/C COMPRESSORS, SPRINKLER, POOL EQUIPMENT, AND WHIRLPOOL PUMPS. 28. MAIN ELECTRICAL SERVICE TO BUILDING TO BE UNDERGROUND. r�,_�„ A.C.U. & CONC. PAD SYMBOL LEGEND : CABLE I) TELE. (INTERNET) JACK OR CABLE (LOCATION AS INDICATED) LATENT COOLING 20A., 120V. DUPLEX RECEPTACLE, GROUNDING TYPE U.O.N. TOTAL COOLING MOUNTED 18" A.F.F. OR AS FIELD DIRECTED ACTUAL AIR FLOW SPECIAL PURPOSE RECEPTACLE (SEE PLAN) E.F� EXHAUST FAN (SEE PLAN FOR LOCATION) STATIC PRESSURE CEILING FAN /LIGHT FIXTURE (SEE PLAN), 10OW. MAX. LOAD SENSIBLE HT, CEILING LIGHT OR EXTERIOR FIXTURE, 10OW. MAX. SD SMOKE DETECTOR (W/ BATTERY BACK -UP) S 120/277V., 20A., SINGLE POLE LIGHT SWITCH S3 120/277V., 20A., THREE -WAY LIGHT SWITCH W. P. INDICATES WEATHER -PROOF FIXTURE V. P. INDICATES VAPOR -PROOF FIXTURE NOTES : 1. ALL LIGHT SWITCHES ARE TO BE INSTALLED 48" A.F.F. 2. ALL ELECT., TELEPHONE /DATA. & CABLE OUTLETS TO BE INSTALLED 18" A.F.F., U.O.N. 10' -0" COVERED PATIO 200A. FPL. METER & DISC. (SEE RISER DIAG.) DWELLING UNIT RECEPTACLE OUTLETS SHALL COMPLY WITH NEC 210.52 ALL BEDROOM OUTLETS SHALL COMPLY WITH NEC 210.12 NOTE: ALL BEDROOM RECEPTACLES TO BE A.F.C.I.P., PER 210 -12B EQUIPMENT SCHEDULE A.C.U. = RHEEM MFG., RASL- 060JEC OR EQUIV. A.H.U. = RHEEM MFG., RCFM- H *6024A * +RGFD- 09 *ZCM* OR �EQUIV. 4.5 TON, 1867 CFM., 16.0 SEER, 10K.W. HT. STRIPS ARI. REF. NO. 3204481 SENSIBLE COOLING 39200 BTUH. LATENT COOLING 16800 BTUH. TOTAL COOLING 56000 BTUH. ACTUAL AIR FLOW 1867 CFM. AIR FLOW FACTOR 0.044 CFM /BTUH. STATIC PRESSURE 0.00 IN H2O LOAD SENSIBLE HT, RATIO 0.86 EXH. FANS (E.F.) = BROAN MODEL #QTRE110, 110CFM. EXH. FAN UTILITY RM. /HALLWAY W/ 4"0 DUCT V.T.R. (OR EQUAL) CIRCUIT BREAKER PANEL "A- (36 CKT. PANEL) 200A.- 120/24OV., 1PH. AIC SYMM - 10,000 CKT. SERVICE WATTS TRIP POLES WIRE # COND. 1 EXT. RECEPT'S. (W /P,GFI) 540 20 1 12 ROMEX 3 UTILITY RM. /HALLWAY 280 20 1 12 a� 5 BEDRM 1 (AFCIP) 1180 20 1 12 LLn 7 BEDRM 1 (AFCIP) 1110 20 1 12 o 9 HOT WATER HEATER 5000 30 2 10 •L O � 11 d 'p, Z N 0 .D O Q 13 A.H.U. (HT. STRIPS) 10000 60 2 6 15 � cn° o = rn W U) ROMEX 17 IRRIG. PUMP (EXISTING) 1500 20 2 12 COND. 19 21 BATH RECEP.'S (GFI) 540 20 1 12 ROMEX 23 DINING RM. LIGHTING 600 20 1 12 ROMEX 25 DINING RM. RECEPT'S. 1080 20 1 12 ROMEX 27 SPARE - -- - -- - -- - -- - -- 29 SPARE - -- - -- - -- - -- - -- 31 SPARE - -- - -- - -- - -- - -- 33 SPARE - -- - -- - -- - -- - -- 35 SPACE - -- - -- - -- - -- 2 BATH LIGHTS - SD. (AFCIP.) 780 20 1 12 ROMEX 4 FAMILY RM. LIGHTS 800 20 1 12 6 FAMILY RM. RECEPT'S. 1080 20 1 12 ROMEX 8 * A.C.U. COMPRESSOR 5000 50 2 10 COND. 10 12 FAMILY RM. RECEPT'S. 1080 20 1 12 ROMEX 14 BEDRM 3 AFCIP 1100 20 1 12 ROMEX 16 BEDRM 4 (AFCIP) 1000 20 1 12 ROMEX 18 EXIST. PNL. "B" 27934 125 2 2 ROMEX 20 22 SPARE - -- - -- - -- - -- - -- 24 SPARE - -- - -- - -- - -- - -- 26 SPARE - -- - -- - -- - -- - -- 28 SPARE - -- - -- - -- - -_ - -- 30 SPARE - -- - -- - -- - -- _ -- 32 SPARE - -- - -- - -- - -- - -- 34 SPARE - -- - -- - -- - -- - -- 36 SPACE - -- - -- - -- - -_ - -_ TOTAL WATTS = 55,604 * NON- CONCURRENT OPTIONAL CALLS.: TOTAL WATTS PER PANEL = 55,604 TOTAL WATTS LESS A/C = 45,604 1ST 10,000 ® 100% = 10,000 BAL 35,604 @ 40% = 14,242 A/C = 10,000 34,242/ 240 = 143.00 AMPS O.H. SERVICE FROM FPL 120/24OV. 1 � OI F.P.L. ELEC. METER 3 -j2/0 THWN Cu. IN 2" DIA. CONDUIT - 200A. MAIN DISCONNECT NEMA 3R. #4 Cu. GND. IN 1/2" PVC. FIN. GRADE 200A. M.L.O. BRK. PANEL 3/4" C.W.P. (2) 5 /8 "x8' -0 "LG. GND. RODS L #4 Cu. GND. IN 1/2" PVC. 200A. - RESIDENCE RISER DIAGRAM N.T.S. 36 CKT. BREAKER PANEL 3 - 2/0 THWN Cu. 1 - 4 BOND IN 2" DIA. CONDUIT REVISIONS BY 0� O LL W Z U Z O WQ 9 Of O J L.L. u):2:2 0WQ < 0 =) Z Ld Wrn V♦ a vW c- z co W J 0 O" V /:E Lo W ct C1 �ti ' �1v1 a u •., ,�� gas � • `' • ,,, •�_ '�I.. DATE AUG., 2009 SCALE 1 /4 " =1 ' -0" BY W Joe AU -0943 ISHT E-1 U 00 O - N I V�� a� .0 On LLn Ln M V) 0 (00 W o ED L3 ) c L L : o '� ED •L O � Ln O d 'p, Z N 0 .D O Q LLJ 3 O ♦^ ^♦ � cn° o = rn W U) L o 0 U C1 �ti ' �1v1 a u •., ,�� gas � • `' • ,,, •�_ '�I.. DATE AUG., 2009 SCALE 1 /4 " =1 ' -0" BY C.R.W. Joe AU -0943 ISHT E-1