09-811-020EXISTING 24' -0"
a �
L_
EXISTING A.C.U., TO REMAIN
(EXISTING MAIN RESIDENCE)
EXIST. LOAD DEMAND
200A
120/240 -
60Hz - 1 P
SERVICE
WATTS
945 SQ.
FT. @ 3w
2835
EXIST.
REFRIG.
1000
EXIST.
OVEN /BURNERS
12000
EXIST.
SMALL APPL.
1500
EXIST.
SMALL APPL.
1500
EXIST.
H.W.H.
4500
EXIST.
A/C (CENTRAL)
10000
EXIST.
WASHER
5000
EXIST.
DRYER
1500
TOTAL EXISTING = 39,835
SCALE: 1/4"=l'-O"
INCOMING 3 -2/0 THWN Cu
TRIP POLES WIRE COND.
15
1
#14 ROMEX
20
1
#12
20
2
#8
20
1
#12
20
1
#12
30
2
#10
50
2
#6
20
1
#12
30
2
#10
ELECT. /LIGHTING PLAN
1. CONTRACTOR SHALL VERIFY WITH FP &L THE LOCATION OF SERVICE AND SHALL LOCATE
METER AND PANELS AS REQUIRED.
2. ALL WIRE SHALL BE THHN COPPER, UNLESS NOTED OTHERWISE.
3. WHERE REQUIRED BY OTHER CODES, SERVICE AND FEEDER CONDUCTORS
SHALL BE COPPER OF EQUAL AMPACITY.
4. ALL BRANCH CIRCUITS IN RACEWAY OR NON METALLIC SHEATHED CABLE.
5. COORDINATE RACEWAY INSTALLATIONS WITH OTHER TRADES PRIOR TO CONSTRUCTION.
6. VERIFY ALL CONDUCTORS AND BREAKERS WITH EQUIPMENT MANUFACTURER SPECIFICATIONS.
7. PROVIDE DISCONNECT SWITCH OF SIZE AS REQUIRED BY LOAD AND UNITS.
8. PROVIDE NON- FUSIBLE GENERAL DUTY SAFETY SWITCHES AT A/C EQUIPMENT AND AT
PUMPS NOT VISABLE FROM CIRCUIT BREAKER PANEL AND AS PER MANUFACTURER RECOMMENDATIONS.
9. PROVIDE GFI BREAKERS FOR ALL BATHROOMS, GARAGE EXTERIOR OULETS AS SHOWN ON PLANS.
10. ELECTRICAL FIXTURES, TRIM AND APPLIANCES SHALL BE UL APPROVED AND AS SELECTED BY OWNER.
11. PROVIDE PRE -WIRED TELEPHONE OUTLETS AS SHOWN ON ELECTRICAL PLAN.
PROVIDE PRE -WIRED T.V. OUTLETS FOR CABLE AS SHOWN ON PLANS.
12. DEDICATED CIRCUITS SHALL HAVE NO MORE THAN 6 DUPLEX RECEPTACLES.
13. IN KITCHENS, DINING ROOMS AND BATHROOMS, RECEPTICAL OUTLETS FOR COUNTER SPACES
SHALL BE GFI PROTECTED ACCORDING TO NEC 210 -8(a).
14. ALL CLOSET LIGHTING SHALL COMPLY WITH NEC SEC. 410.8.
15. SMOKE DETECTORS SHALL BE CONNECTED TO KITCHEN OR BATH LIGHTING CIRCUITS AHEAD
OF SWITCH AND HAVE SELF CONTAINED BATTERY BACK -UP. DETECTORS SHALL BE TANDEM
WIRED SO ALL DETECTORS SOUND SIMULTANEOUSLY,
OPTIONAL CALCS.:
TOTAL WATTS LESS A/C
1 ST 10,000 ® 100%
BAL 19,835 0 40%
A/C
WATTS PER EX. PNL. "B "= 39,835
= 29,835
= 10,000
7,934
10,000
27,934/ 240 = 116.4 AMPS
16. PREWIRE FOR GARAGE DOOR OPENER SENSOR. (NOTE AS APPLICABLE)
17. ALL OUTLET BOXES FOR RECEPTICALS, TV ANTENNAS, OR TELEPHONE JACKS, ETC. IN
RATED WALLS MUST BE METAL OR U.L. RATED FOR USE IN ONE HOUR FIRE RATED CONSTRUCTION.
18. ALL ELECTRICAL WORK TO CONFORM TO THE NATIONAL ELECTRICAL CODE AND NFPA 70.
19. ELECTRICAL CONTRACTOR TO CONFORM WITH BELLSOUTH REQUIREMENTS FOR
TELEPHONE EQUIPMENT INSTALLATION
20. CO- ORDINATE ALL CONDUIT RUNS AND EQUIPMENT INSTALLATION WITH OTHER TRADES TO AVOID
CONFLICTS PRIOR TO FABRICATION, INSTALLATION, AND ERECTION.
21. ELECTRICAL CONTRACTOR TO VERIFY ALL HVAC UNIT CONNECTIONS WITH HVAC
CONTRACTOR PRIOR TO INSTALLATION. ALL A/C UNITS TO HAVE INTERNAL BREAKERS.
22. ALL METERS, METER CENTERS AND DISCONNECTS TO BE APPROVED BY FP &L.
23. MINIMUM WIRE SIZE SHALL BE #14 AWG INSULA11ON FOR WIRE SIZE #6 AND SMALLER
SHALL BE THWN #4 AND LARGER SHALL BE THHN. ALL CONDUCTORS #10 AND SMALLER
MAY BE SOLID #3 AND LARGER SHALL BE STRANDED ( ROMEX MAY BE USED WHERE APPROVED.)
24. CIRCUIT LOCATION AND LOAD DATA ARE BASED UPON INFORMATION GIVEN TO THE
ARCHITECT AT TIME OF DESIGN. CONTACTOR SHALL VERIFY ALL EQUIPMENT AND PANEL
SIZES AND SHALL PROVIDE CIRCUITS AND ROUTING OF CONDUITS TO SUIT JOB CONDTIONS.
25. ALL 120V 1 PHASE 15A AND 20A GARAGE AND EXTERIOR RECEPTACLES SHALL
HAVE GROUND FAULT INTERRUPTER (GFI) PROTECTION.
26. USE GFI CIRCUIT BREAKERS ON GFI RECEPTACLES.
27. PROVIDE W.P. DISCONNECTS AT ALL A/C COMPRESSORS, SPRINKLER, POOL EQUIPMENT,
AND WHIRLPOOL PUMPS.
28. MAIN ELECTRICAL SERVICE TO BUILDING TO BE UNDERGROUND.
r�,_�„
A.C.U. &
CONC. PAD
SYMBOL LEGEND :
CABLE I)
TELE. (INTERNET) JACK OR CABLE (LOCATION AS INDICATED)
LATENT COOLING
20A., 120V. DUPLEX RECEPTACLE, GROUNDING TYPE U.O.N.
TOTAL COOLING
MOUNTED 18" A.F.F. OR AS FIELD DIRECTED
ACTUAL AIR FLOW
SPECIAL PURPOSE RECEPTACLE (SEE PLAN)
E.F�
EXHAUST FAN (SEE PLAN FOR LOCATION)
STATIC PRESSURE
CEILING FAN /LIGHT FIXTURE (SEE PLAN), 10OW. MAX.
LOAD SENSIBLE HT,
CEILING LIGHT OR EXTERIOR FIXTURE, 10OW. MAX.
SD
SMOKE DETECTOR (W/ BATTERY BACK -UP)
S
120/277V., 20A., SINGLE POLE LIGHT SWITCH
S3
120/277V., 20A., THREE -WAY LIGHT SWITCH
W. P.
INDICATES WEATHER -PROOF FIXTURE
V. P.
INDICATES VAPOR -PROOF FIXTURE
NOTES :
1. ALL LIGHT SWITCHES ARE TO BE INSTALLED 48" A.F.F.
2. ALL ELECT., TELEPHONE /DATA. & CABLE OUTLETS TO
BE INSTALLED 18" A.F.F., U.O.N.
10' -0"
COVERED PATIO
200A. FPL. METER & DISC.
(SEE RISER DIAG.)
DWELLING UNIT
RECEPTACLE OUTLETS
SHALL COMPLY
WITH NEC 210.52
ALL BEDROOM OUTLETS
SHALL COMPLY WITH
NEC 210.12
NOTE:
ALL BEDROOM
RECEPTACLES TO
BE A.F.C.I.P.,
PER 210 -12B
EQUIPMENT SCHEDULE
A.C.U. = RHEEM MFG., RASL- 060JEC OR EQUIV.
A.H.U. = RHEEM MFG., RCFM- H *6024A * +RGFD- 09 *ZCM* OR �EQUIV.
4.5 TON, 1867 CFM., 16.0 SEER, 10K.W. HT. STRIPS
ARI. REF. NO. 3204481
SENSIBLE COOLING
39200 BTUH.
LATENT COOLING
16800 BTUH.
TOTAL COOLING
56000 BTUH.
ACTUAL AIR FLOW
1867 CFM.
AIR FLOW FACTOR
0.044 CFM /BTUH.
STATIC PRESSURE
0.00 IN H2O
LOAD SENSIBLE HT,
RATIO 0.86
EXH. FANS (E.F.)
= BROAN MODEL #QTRE110, 110CFM. EXH. FAN
UTILITY RM. /HALLWAY
W/ 4"0 DUCT V.T.R. (OR EQUAL)
CIRCUIT BREAKER PANEL "A- (36 CKT. PANEL)
200A.- 120/24OV., 1PH. AIC SYMM - 10,000
CKT.
SERVICE
WATTS
TRIP
POLES
WIRE #
COND.
1
EXT. RECEPT'S. (W /P,GFI)
540
20
1
12
ROMEX
3
UTILITY RM. /HALLWAY
280
20
1
12
a�
5
BEDRM 1 (AFCIP)
1180
20
1
12
LLn
7
BEDRM 1 (AFCIP)
1110
20
1
12
o
9
HOT WATER HEATER
5000
30
2
10
•L
O �
11
d
'p,
Z
N
0 .D
O Q
13
A.H.U. (HT. STRIPS)
10000
60
2
6
15
�
cn° o
=
rn
W
U)
ROMEX
17
IRRIG. PUMP (EXISTING)
1500
20
2
12
COND.
19
21
BATH RECEP.'S (GFI)
540
20
1
12
ROMEX
23
DINING RM. LIGHTING
600
20
1
12
ROMEX
25
DINING RM. RECEPT'S.
1080
20
1
12
ROMEX
27
SPARE
- --
- --
- --
- --
- --
29
SPARE
- --
- --
- --
- --
- --
31
SPARE
- --
- --
- --
- --
- --
33
SPARE
- --
- --
- --
- --
- --
35
SPACE
- --
- --
- --
- --
2
BATH LIGHTS - SD. (AFCIP.)
780
20
1
12
ROMEX
4
FAMILY RM. LIGHTS
800
20
1
12
6
FAMILY RM. RECEPT'S.
1080
20
1
12
ROMEX
8
* A.C.U. COMPRESSOR
5000
50
2
10
COND.
10
12
FAMILY RM. RECEPT'S.
1080
20
1
12
ROMEX
14
BEDRM 3 AFCIP
1100
20
1
12
ROMEX
16
BEDRM 4 (AFCIP)
1000
20
1
12
ROMEX
18
EXIST. PNL. "B"
27934
125
2
2
ROMEX
20
22
SPARE
- --
- --
- --
- --
- --
24
SPARE
- --
- --
- --
- --
- --
26
SPARE
- --
- --
- --
- --
- --
28
SPARE
- --
- --
- --
- -_
- --
30
SPARE
- --
- --
- --
- --
_ --
32
SPARE
- --
- --
- --
- --
- --
34
SPARE
- --
- --
- --
- --
- --
36
SPACE
- --
- --
- --
- -_
- -_
TOTAL WATTS = 55,604
* NON- CONCURRENT
OPTIONAL CALLS.: TOTAL WATTS PER PANEL = 55,604
TOTAL WATTS LESS A/C = 45,604
1ST 10,000 ® 100% = 10,000
BAL 35,604 @ 40% = 14,242
A/C = 10,000
34,242/ 240 = 143.00 AMPS
O.H. SERVICE FROM FPL
120/24OV. 1 �
OI F.P.L. ELEC. METER
3 -j2/0 THWN Cu.
IN 2" DIA. CONDUIT -
200A. MAIN
DISCONNECT
NEMA 3R.
#4 Cu. GND.
IN 1/2" PVC.
FIN. GRADE
200A. M.L.O.
BRK. PANEL
3/4" C.W.P.
(2) 5 /8 "x8' -0 "LG.
GND. RODS L #4 Cu. GND.
IN 1/2" PVC.
200A. - RESIDENCE RISER DIAGRAM
N.T.S.
36 CKT.
BREAKER
PANEL
3 - 2/0 THWN Cu.
1 - 4 BOND
IN 2" DIA. CONDUIT
REVISIONS BY
0�
O
LL W
Z
U
Z
O
WQ
9
Of
O
J
L.L.
u):2:2
0WQ
< 0 =)
Z
Ld
Wrn
V♦ a
vW c-
z co
W J
0 O"
V /:E Lo
W
ct
C1
�ti ' �1v1 a u •., ,��
gas � • `' • ,,, •�_ '�I..
DATE
AUG., 2009
SCALE 1 /4 " =1 ' -0"
BY
W
Joe
AU -0943
ISHT
E-1
U
00
O
-
N
I
V��
a�
.0
On
LLn
Ln
M
V)
0
(00
W
o
ED
L3 )
c
L L
: o '�
ED
•L
O �
Ln
O
d
'p,
Z
N
0 .D
O Q
LLJ
3 O
♦^
^♦
�
cn° o
=
rn
W
U)
L
o
0
U
C1
�ti ' �1v1 a u •., ,��
gas � • `' • ,,, •�_ '�I..
DATE
AUG., 2009
SCALE 1 /4 " =1 ' -0"
BY
C.R.W.
Joe
AU -0943
ISHT
E-1