Loading...
09-811-018ooi IV �I S IQc�i • EXISTING 24' -0" ��_j esTaen ,ce KH. LT. ex,. itc e M 13' -10" TRAY CLG. LIMITS J J I� I� 0 0 dining room + 25'- 10" - - - - TRAY CLG . LIMITS - - - - - I "' I 55' -6" 12' -4" ' -0" MARK I 7' -2" DRAIN 15' -0" 1 I COLD c.o.(2 way) walk -in co (EXISTING MAIN RESIDENCE) N/A ci I closet ooi I� EXIST. SEPTIC °-- TANK & DRAINFIEL 1/2" L r REMOVED UNDER THIS PERMIT,,, ABANDONED & REMOVED.. NEW SEPTIC TANK ] H.W.H. SEE NOTE 4 I I RELOCATED T SEE SPECS/ NOTES REAR OF PROPERTY„ BELOW ADDITION LIMITS 1/2" W /GARBAGE DISPOSAL 1350GAL. SEPTIC TANK & NEW DRAINFIELD DISHWASHER 1" LOCATED ALONG REAR OF PROPERTY 10 N SEE NOTE 1 - - L. C. - -- 2" A.H.U. - - N , I closet A GALS. SEE NOTE 2 DRAINFIELD INFO. 1000 S.F.,, - DRAINFIELD RESERVE AREA 500 S.F., RESERVE AREA REQ'D. 0 1 /2„ EX3" WATER TABLE 3.5' B.F.G. SEE NOTE 4 AVERAGE GRADE ELEVATION 8.50' o-0 L0 REFER TO SOIL PROFILE INFO.,, DEPT. OF HEALTH SEWAGE FORM -- 2„ 3" REWORK EXIST. 3 "SAN. I Z N w LINE TO NEW SEPTIC ♦♦^^ V ♦ 0 3 O iv TI -IN (FIELD COORD.) 2"STUDC R 1 /2" L N master bedroom VENT \ L c 00 bedroom N Cu 7' 6" I 0 2 11' -0" '�2 T -o MARK ,- DRAIN 3pp 1 I COLD c.o.(2 way) EXISTING A.C.U., TO REMAIN �_j WATER CLOSET -TANK 4" (EXISTING MAIN RESIDENCE) N/A ci " LAVATORY- COUNTERTOP 3„ 1/2" 1/2" NOTE : EXISTING SEPTIC TANK & DRAINFIELD BATH TUB w C.O. ABANDONED & REMOVED.. NEW SEPTIC TANK 1/2" SEE NOTE 4 & DRAINFIELD LOCATED OUTSIDE OF NEW KITCHEN SINK 1 -1/2" ADDITION LIMITS 1/2" W /GARBAGE DISPOSAL 1350GAL. SEPTIC TANK & NEW DRAINFIELD DISHWASHER 1" LOCATED ALONG REAR OF PROPERTY 1/2" SEE NOTE 1 (REFER TO DWG. SP -1) CLOTHES WASHER 2" TANK INFO. 1350 GALS. SEE NOTE 2 DRAINFIELD INFO. 1000 S.F.,, 36" AVG, BELOW GRADE DRAINFIELD RESERVE AREA 500 S.F., RESERVE AREA REQ'D. ESTIMATED SEWAGE FLOW 600 GPD.,, PER TABLE 1 WATER TABLE 3.5' B.F.G. SEE NOTE 4 AVERAGE GRADE ELEVATION 8.50' o-0 L0 REFER TO SOIL PROFILE INFO.,, DEPT. OF HEALTH SEWAGE FORM SCALE: 1/4"=V-0" PLUMBING IMPROVEMENT PLAN GENERAL PLUMBING NOTES : 1. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS AND EQUIPMENT NECESSARY FOR THE INSTALLATION OF A COMPLETE PLUMBING SYSTEM IN ACCORDANCE WITH THESE DRAWINGS, THE APPLICABLE EDITION OF THE FLORIDA BUILDING CODE, ALL OTHER APPLICABLE STATE, COUNTY AND LOCAL ORDINANCES, 2. THE CONTRACTOR SHALL PAY ALL COSTS OF PERMIT, INSPECTIONS AND ALL OTHER COSTS INCIDENTAL TO THE COMPLETION AND TESTING OF THIS WORK UPON FINAL ACCEPTANCE, A CERTIFICATE FROM THE LOCAL INSPECTION AUTHORITY SHALL BE FURNISHED TO THE OWNER. 3. ALL MATERIALS AND EQUIPMENTS SHALL BE NEW OF U.S. MANUFACTURE AND OF GOOD QUALITY OF RESPECTIVE KIND AND GRADE, AND MUST BE FURNISHED SO AS TO PREVENT ANY DELAY IN THE PROGRESS OF THE WORK. ALL WORK THROUGH SHALL BE PERFORMED IN A WORKMANLIKE MANNER BY SUFFICIENT NUMBER OF SKILLED WORKMEN. 4. CONTRACTOR SHALL VISIT THE SITE AND REVIEW ALL PERTINENT UTILITY DRAWINGS TO FAMILIARIZE HIMSELF WITH THE LOCATION OF ALL EXISTING AND /OR PROPOSED UTILITY STUB OUTS, PIPING, EQUIPMENT, ETC., AND MAKE DUE ALLOWANCES FOR ANY CONDITION EFFECTING HIS WORK. 5. ALL UNDERGROUND SANITARY & STORM DRAINAGE PIPING AND FITTINGS SHALL BE PVC -DWV (ASTM D- 2662/D- 3034). 6. ALL ABOVE GROUND SANITARY & STORM DRAINAGE BRANCH & VENT PIPES AND FITTINGS SHALL BE PVC -DWV (ASTM D- 2662/D- 3034). 7. ALL UNDERGROUND WATER PIPING SHALL BE SPELLING TYPE "1" (ASTM B -306). ALL ABOVE GROUND PIPING SHALL BE "CPVC" PIPING, U.O.N. 8. ALL HOT WATER PRESSURE AND TEMPERATURE RELIEF PIPING SHALL BE "CPVC." PIPING, U.O.N. 9. ALL AIR CONDITIONING CONDENSATE DRAINAGE PIPING SHALL BE SCH. 40 PVC (ASTM D- 2662), EXCEPT WHEN INSTALLED IN RETURN AIR PLENUM WHERE COPPER TYPE "DWV" OR EQUIVALENT MUST BE USED. 16' -8" family room 28' -8" c I IF_ I• 11 " 2» 3" J 4 c.o.(2 way) /'SHUT O VE --BIBS VALVE c.o.(2 way) 3" 3" 4 "SAN. LINE TO SEPTIC TANK (c.o's SPACED @75' O.C.) EXIST. SOUTH PROPERTY LINE N.89'42'07 "W. 166.50' 10. ALL PLUMBING FIXTURES SHALL BE PROVIDED WITH ALL NECESSARY ACCESSORIES SUCH AS STOP VALVES, "P" TRAPS, SUPPORTS, P & T VALVES, ETC., AS REQUIRED. ALL EXPOSED PIPING AT FIXTURES AND EQUIPMENT SHALL BE CHROME PLATED BRASS PIPE OR TUBE. PROVIDE SHUT OFF VALVES AND UNIONS TO ALL FIXTURES, ETC., REQUIRING WATER SUPPLY. PROVIDE DIELECTRIC COUPLINGS AS REQUIRED. FOR ALL COPPER PIPING CONTRACTOR MUST USE LEAD FREE SOLDER. PROVIDE AIR CHAMBERS TO EACH FIXTURE AS REQUIRED. 11. PROVIDE CLEAN OUTS (WITH ESCUTCHEONS AS REQUIRED) AT THE BASE OF ALL WASTE AND /OR VENT STACKS. PROVIDE PITCH PANS & LEADS FLASHING FOR ALL SANITARY SYSTEM VENTS. 12. ALL DRAINING PIPES 2 "0 OR SMALLER TO BE SLOPED 1/4" PER FOOT. 13. ALL DRAINING PIPES 3 "0 OR BIGGER TO BE SLOPED 1/8" PER FOOT. 14. PLUMBING CONTRACTOR MUST VERIFY LOCATION OF PIPE LINES IN RELATION TO FOOTINGS AT FOUNDATION PLAN. IF THERE IS ANY CONFLICT MUST NOTIFY THE ARCHITECT OR ENGINEER PRIOR COMMENCING WORK. 15. PLUMBING CONTRACTOR TO PROVIDE AIR CHAMBERS TO ALL PLUMB'G FIXTURES 16. ALL FIRE RATED FLOOR & WALL PENETRATIONS SHALL BE PROPERLY PROTECTED FROM FIRE, SMOKE & WATER PENETRATION, BY FILLING VOIDS BETWEEN PIPE & WALL /FLOOR SLEEVES W/ FIRE -RATED FOAM, TO ACHIEVE THE SAME RATING AS WALLS OR FLOORS AS PART OF ANY PLUMBERS WORK. 17. STUDOR MINI -MAX AIR ADMITTANCE VALVES /VENTS MAY BE USED AS AN ALTERNATE TO VENT PIPING THRU ROOF, WHERE ACCEPTABLE BY PLUMBING OFFICIAL AND AS LOCAL CODES DICTATE. INSTALL AS PER MANUF'S. SPECIFICATIONS. N W I+ MM - closet- I r IL JI closet i bedroom 0 12' -0" PLUMBING FIXTURE CONNECTION SCHEDULE MARK DESCRIPTION DRAIN WATER REMARKS COLD HOT LABELED WATER CLOSET -TANK 4" 1/2" N/A HEAT TRAP " LAVATORY- COUNTERTOP 1 -1/2" 1/2" 1/2" STORAGE : 65 GAL. BATH TUB 1-1/2"(2-) 1/2" 1/2" SEE NOTE 4 " KITCHEN SINK 1 -1/2" 1/2" 1/2" W /GARBAGE DISPOSAL WATER HEATER DISHWASHER 1" N/A 1/2" SEE NOTE 1 " CLOTHES WASHER 2" 1/2" 1/2" SEE NOTE 2 " REFRIGERATOR N/A 1/2" 1 N/A ICE MAKER SERVICE " SHOWER 2" 1/2" 1/2" SEE NOTE 4 �L o-0 L0 ■ N C LL E O O Z N w Q a) GENERAL NOTES : 1. CONNECT DRAIN TO GARBAGE DISPOSAL WITH FLEXIBLE TUBING. 2. DRAIN AND HOSE BIBBS (2) INSTALLED IN RECESSED MOUNTED SERVICE BOX. 3. PROVIDE VACUUM BREAKER. 4. PROVIDE ANTI -SCALD VALVE. 5. 2" UNDER SLAB 10' -0" COVERED PATIO I Co open patio i� ,I C4 I� .p s 3/4" HOSE BIBS W/ SHUT OFF VALVE o0en patio 1350GAL. SEPTIC TANK & 1000 S.F. 4 ' SAN. LINE TO SEPTIC TANK DRAINFIELD (c.o's SPACED ®75' O.C.) (SEE SPECS. BELOW) 12 "to14' MATCH EXIST. F.F.E.(FLUSH) EXIST. 5" CONIC. SLAB 5 "CONC. FLOOR POUR (4" MIN.) W/6x6,10/10 6MIL. VAPOR BARRIER W.W.M., FULL LIMITS OVER TERMITE TREATED BACKFILL EXIST. EXCAVATED MATERIAL SAN. PIPING BACKFILLED UPON COMPLETION FLOOR -CUT REPAIR SCALE : N.T.S. (AS APPLICABLE) CAP FOR FUTURE CONNECTION SOLAR FOR F TUBE OR HEAT RECOVERY CAP n n OR HEAT RECOVERY n , RELIEF VALVE /LINE HOT WATER n COLD WATER - HEAT TRAP ri - HEAT TRAP H.W.H. P & T RELIEF PIPE TO ELECTRIC WATER HEATER OUTSIDE BLDG TERMINATE 4.5KW, 240/1/60 STORAGE : 65 GAL. INSTALL DRIP PAN AT ENERGY FACTOR 0.89 BASE OF WATER HEATER AS PER FBC 4614 18C TO 7 6" ABOVE GRADE F - - - - - - - _11" PVC DRAIN PAN (DRAIN) FLOOR U WATER HEATER PIPING DETAIL N.T.S. i TO CONDENSATE M n V) DRAIN LINE A/C UNIT DRAIN L CONNECTION NOTE: INSTALLATION OF PIPING TO CLEAR ° FILTER PULL OUT AREA & SERVICE REMOVABLE PANELS CONDENSATE DRAIN DETAIL N.T.S. (A.H.U. CONNECTION) -P.EVISIONS BY 0. O LL W Z LD Z W0 O t W � Q W a Ld Z w WCna UW� z co WJN_ clot W C1 AUG., 2009 ?� ; t4i C.R.W. , SHT P - 1 'OL U 6] 00, U cu -S N UN d7 co U O LO M n V) n L N ° W > �L o-0 L0 ■ N C LL E O O Z N w Q a) ♦♦^^ V ♦ 0 3 O _ d- co '- L c 00 Cu c0 U C1 DATE AUG., 2009 ?� ; t4i C.R.W. , SHT P - 1 'OL U DATE AUG., 2009 SCALE 1/4 " =1' -0" BY C.R.W. JOB AU -0943 SHT P - 1 a =-