Loading...
09-811-017I� I� \I EXISTING 24' -0" au & stm\g a kNi es en,*c e KH.LN F FL SH MATCH F.F.E. I I� Ir � 13' -10" 58' -6" O.A. ADDITION LIMITS 49)-6" 11' -10" TRAY CLG. LIMITS I IHI I II II I II � II � II N �I II � it II r it dining room k I I I I IN NI II II e it en 25' -10" \ - - - - -- TRAYCLG_LIMITS - - - - -- J opento storage - I - -- O 1 e u ' I . -011 4'­8" jI I EXIST. SEPTIC TAN & DRAINFIEL walk -in REMOVED UNDER HIS PERMIT,,, I closet RELOCATED TO REAR OF PROPE walk -in ( walk in / H.W.H. LL - - - SEE SPECS /NOTES BELOW closet i i clos t O'N0 - -� - - 3' -7 J3' -7' ex. th 3" \Y1 R. ° I 1 V2" master bedroom REWORK EXIST. 3 "SAN. LINE TO NEW SEPTIC -A TIE -IN (FIELD COORD.) 3" bedroom 15' -4" 1 family room 22' -8" 3' -0" 9' -2" l 4� .o - - - - 2 "V.T.R. c.o.(2 way) A.C.U. & 1 CONC. PAD Q zo 3„ (SEE DETAIL) 0 EXISTING A.C.U., TO REMAIN (EXISTING MAIN RESIDENCE) L �J `� rd o 0 U' °¢ C.O. 4 "SAN. LINE TO SEPTIC TANK RELOCATED HOSE -BIBB & IN -LINE X 1s � (c.o's SPACED @75' O.C.) CONTROL VALVE (SHUT -OFF) w I o i� EXIST. SOUTH PROPERTY LINE N.89'42'07 "W. 166.50' NOTE : EXISTING SEPTIC TANK & DRAINFIELD TANK INFO. 1350 GALS. ABANDONED & REMOVED.. NEW SEPTIC TANK DRAINFIELD INFO. 1000 S.F.,, 36" AVG. BELOW GRADE & DRAINFIELD LOCATED OUTSIDE OF NEW ADDITION LIMITS DRAINFIELD RESERVE AREA 500 S.F., RESERVE AREA REVD. 1350GAL. SEPTIC TANK & NEW DRAINFIELD ESTIMATED SEWAGE FLOW 600 GPD.,, PER TABLE 1 LOCATED ALONG REAR OF PROPERTY WATER TABLE 3.5' B.F.G. AVERAGE GRADE ELEVATION 9.40' REFER TO SOIL PROFILE INFO.,, DEPT. OF HEALTH SEWAGE FORM NOTE PER HEALTH DEPT. THERE ARE NO PERTINENT FEATURES ON ADJACENT PROPERTIES AND ACROSS THE STREET THAT MAY AFFECT SEPTIC SYSTEM INSTALLATION. 10' -11" 6' -2" 0 N 1 1� 2" T.R. 3" bed roo SCALE: 1/4"=V-0" ' -0" PLUMBING IMPROVEMENT PLAN GENERAL PLUMBING NOTES 1. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS AND EQUIPMENT NECESSARY FOR THE INSTALLATION OF A COMPLETE PLUMBING SYSTEM IN ACCORDANCE WITH THESE DRAWINGS, THE APPLICABLE EDITION OF THE FLORIDA BUILDING CODE, ALL OTHER APPLICABLE STATE, COUNTY AND LOCAL ORDINANCES. 2. THE CONTRACTOR SHALL PAY ALL COSTS OF PERMIT, INSPECTIONS AND ALL OTHER COSTS INCIDENTAL TO THE COMPLETION AND TESTING OF THIS WORK UPON FINAL ACCEPTANCE, A CERTIFICATE FROM THE LOCAL INSPECTION AUTHORITY SHALL BE FURNISHED TO THE OWNER. 3. ALL MATERIALS AND EQUIPMENTS SHALL BE NEW OF U.S. MANUFACTURE AND OF GOOD QUALITY OF RESPECTIVE KIND AND GRADE, AND MUST BE FURNISHED SO AS TO PREVENT ANY DELAY IN THE PROGRESS OF THE WORK. ALL WORK THROUGH SHALL BE PERFORMED IN A WORKMANLIKE MANNER BY SUFFICIENT NUMBER OF SKILLED WORKMEN. 4. CONTRACTOR SHALL VISIT THE SITE AND REVIEW ALL PERTINENT UTILITY DRAWINGS TO FAMILIARIZE HIMSELF WITH THE LOCATION OF ALL EXISTING AND /OR PROPOSED UTILITY STUB OUTS, PIPING, EQUIPMENT, ETC., AND MAKE DUE ALLOWANCES FOR ANY CONDITION EFFECTING HIS WORK. 5. ALL UNDERGROUND SANITARY & STORM DRAINAGE PIPING AND FITTINGS SHALL BE PVC -DWV (ASTM D- 2662/D- 3034). 6. ALL ABOVE GROUND SANITARY & STORM DRAINAGE BRANCH & VENT PIPES AND FITTINGS SHALL BE PVC -DWV (ASTM D- 2662/D- 3034). 7. ALL UNDERGROUND WATER PIPING SHALL BE SPELLING TYPE "1" (ASTM B -306). ALL ABOVE GROUND PIPING SHALL BE "CPVC" PIPING, U.O.N. 8. ALL HOT WATER PRESSURE AND TEMPERATURE RELIEF PIPING SHALL BE "CPVC." PIPING, U.O.N. 9. ALL AIR CONDITIONING CONDENSATE DRAINAGE PIPING SHALL BE SCH. 40 PVC (ASTM D- 2662), EXCEPT WHEN INSTALLED IN RETURN AIR PLENUM WHERE COPPER TYPE "DWV" OR EQUIVALENT MUST BE USED. 10. ALL PLUMBING FIXTURES SHALL BE PROVIDED WITH ALL NECESSARY ACCESSORIES SUCH AS STOP VALVES, "P" TRAPS, SUPPORTS, P & T VALVES, ETC., AS REQUIRED. ALL EXPOSED PIPING AT FIXTURES AND EQUIPMENT SHALL BE CHROME PLATED BRASS PIPE OR TUBE. PROVIDE SHUT OFF VALVES AND UNIONS TO ALL FIXTURES, ETC., REQUIRING WATER SUPPLY. PROVIDE DIELECTRIC COUPLINGS AS REQUIRED. FOR ALL COPPER PIPING CONTRACTOR MUST USE LEAD FREE SOLDER. PROVIDE AIR CHAMBERS TO EACH FIXTURE AS REQUIRED. 11. PROVIDE CLEAN OUTS (WITH ESCUTCHEONS AS REQUIRED) AT THE BASE OF ALL WASTE AND /OR VENT STACKS. PROVIDE PITCH PANS & LEADS FLASHING FOR ALL SANITARY SYSTEM VENTS. 12. ALL DRAINING PIPES 2 "0 OR SMALLER TO BE SLOPED 1/4" PER FOOT. 13. ALL DRAINING PIPES 3 "0 OR BIGGER TO BE SLOPED 1/8" PER FOOT. 14. PLUMBING CONTRACTOR MUST VERIFY LOCATION OF PIPE LINES IN RELATION TO FOOTINGS AT FOUNDATION PLAN. IF THERE IS ANY CONFLICT MUST NOTIFY THE ARCHITECT OR ENGINEER PRIOR COMMENCING WORK. 15. PLUMBING CONTRACTOR TO PROVIDE AIR CHAMBERS TO ALL PLUMB'G FIXTURES 16. ALL FIRE RATED FLOOR & WALL PENETRATIONS SHALL BE PROPERLY PROTECTED FROM FIRE, SMOKE & WATER PENETRATION, BY FILLING VOIDS BETWEEN PIPE & WALL /FLOOR SLEEVES W/ FIRE -RATED FOAM, TO ACHIEVE THE SAME RATING AS WALLS OR FLOORS AS PART OF ANY PLUMBERS WORK. 17. STUDOR MINI -MAX AIR ADMITTANCE VALVES /VENTS MAY BE USED AS AN ALTERNATE TO VENT PIPING THRU ROOF, WHERE ACCEPTABLE BY PLUMBING OFFICIAL AND AS LOCAL CODES DICTATE. INSTALL AS PER MANUF'S. SPECIFICATIONS. c.o.(2 way) 9' -0" COVERED PATIO a) I io I I open patio I I 6" I , 01 3/4" HOSE -BIBB W/ SHUT OFF VALVE open patio J z 0 L_ D < Q 6" 717. I ip 3" 1350GAL. SEPTIC \ TANK & 1000 S.F. 4 "SAN. LINE TO SEPTIC TANK DRAINFIELD (c.o's SPACED @75' O.C.) (SEE SPECS. BELOW) -- -- -- -- - - -- PLUMBING FIXTURE CONNECTION SCHEDULE MARK 4' U) DRAIN WATER REMARKS COLD HOT I° WATER CLOSET -TANK 4" 12, N/A 2, " LAVATORY - COUNTERTOP 1-1/2" I I .o - - - - 2 "V.T.R. c.o.(2 way) A.C.U. & 1 CONC. PAD Q zo 3„ (SEE DETAIL) 0 EXISTING A.C.U., TO REMAIN (EXISTING MAIN RESIDENCE) L �J `� rd o 0 U' °¢ C.O. 4 "SAN. LINE TO SEPTIC TANK RELOCATED HOSE -BIBB & IN -LINE X 1s � (c.o's SPACED @75' O.C.) CONTROL VALVE (SHUT -OFF) w I o i� EXIST. SOUTH PROPERTY LINE N.89'42'07 "W. 166.50' NOTE : EXISTING SEPTIC TANK & DRAINFIELD TANK INFO. 1350 GALS. ABANDONED & REMOVED.. NEW SEPTIC TANK DRAINFIELD INFO. 1000 S.F.,, 36" AVG. BELOW GRADE & DRAINFIELD LOCATED OUTSIDE OF NEW ADDITION LIMITS DRAINFIELD RESERVE AREA 500 S.F., RESERVE AREA REVD. 1350GAL. SEPTIC TANK & NEW DRAINFIELD ESTIMATED SEWAGE FLOW 600 GPD.,, PER TABLE 1 LOCATED ALONG REAR OF PROPERTY WATER TABLE 3.5' B.F.G. AVERAGE GRADE ELEVATION 9.40' REFER TO SOIL PROFILE INFO.,, DEPT. OF HEALTH SEWAGE FORM NOTE PER HEALTH DEPT. THERE ARE NO PERTINENT FEATURES ON ADJACENT PROPERTIES AND ACROSS THE STREET THAT MAY AFFECT SEPTIC SYSTEM INSTALLATION. 10' -11" 6' -2" 0 N 1 1� 2" T.R. 3" bed roo SCALE: 1/4"=V-0" ' -0" PLUMBING IMPROVEMENT PLAN GENERAL PLUMBING NOTES 1. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS AND EQUIPMENT NECESSARY FOR THE INSTALLATION OF A COMPLETE PLUMBING SYSTEM IN ACCORDANCE WITH THESE DRAWINGS, THE APPLICABLE EDITION OF THE FLORIDA BUILDING CODE, ALL OTHER APPLICABLE STATE, COUNTY AND LOCAL ORDINANCES. 2. THE CONTRACTOR SHALL PAY ALL COSTS OF PERMIT, INSPECTIONS AND ALL OTHER COSTS INCIDENTAL TO THE COMPLETION AND TESTING OF THIS WORK UPON FINAL ACCEPTANCE, A CERTIFICATE FROM THE LOCAL INSPECTION AUTHORITY SHALL BE FURNISHED TO THE OWNER. 3. ALL MATERIALS AND EQUIPMENTS SHALL BE NEW OF U.S. MANUFACTURE AND OF GOOD QUALITY OF RESPECTIVE KIND AND GRADE, AND MUST BE FURNISHED SO AS TO PREVENT ANY DELAY IN THE PROGRESS OF THE WORK. ALL WORK THROUGH SHALL BE PERFORMED IN A WORKMANLIKE MANNER BY SUFFICIENT NUMBER OF SKILLED WORKMEN. 4. CONTRACTOR SHALL VISIT THE SITE AND REVIEW ALL PERTINENT UTILITY DRAWINGS TO FAMILIARIZE HIMSELF WITH THE LOCATION OF ALL EXISTING AND /OR PROPOSED UTILITY STUB OUTS, PIPING, EQUIPMENT, ETC., AND MAKE DUE ALLOWANCES FOR ANY CONDITION EFFECTING HIS WORK. 5. ALL UNDERGROUND SANITARY & STORM DRAINAGE PIPING AND FITTINGS SHALL BE PVC -DWV (ASTM D- 2662/D- 3034). 6. ALL ABOVE GROUND SANITARY & STORM DRAINAGE BRANCH & VENT PIPES AND FITTINGS SHALL BE PVC -DWV (ASTM D- 2662/D- 3034). 7. ALL UNDERGROUND WATER PIPING SHALL BE SPELLING TYPE "1" (ASTM B -306). ALL ABOVE GROUND PIPING SHALL BE "CPVC" PIPING, U.O.N. 8. ALL HOT WATER PRESSURE AND TEMPERATURE RELIEF PIPING SHALL BE "CPVC." PIPING, U.O.N. 9. ALL AIR CONDITIONING CONDENSATE DRAINAGE PIPING SHALL BE SCH. 40 PVC (ASTM D- 2662), EXCEPT WHEN INSTALLED IN RETURN AIR PLENUM WHERE COPPER TYPE "DWV" OR EQUIVALENT MUST BE USED. 10. ALL PLUMBING FIXTURES SHALL BE PROVIDED WITH ALL NECESSARY ACCESSORIES SUCH AS STOP VALVES, "P" TRAPS, SUPPORTS, P & T VALVES, ETC., AS REQUIRED. ALL EXPOSED PIPING AT FIXTURES AND EQUIPMENT SHALL BE CHROME PLATED BRASS PIPE OR TUBE. PROVIDE SHUT OFF VALVES AND UNIONS TO ALL FIXTURES, ETC., REQUIRING WATER SUPPLY. PROVIDE DIELECTRIC COUPLINGS AS REQUIRED. FOR ALL COPPER PIPING CONTRACTOR MUST USE LEAD FREE SOLDER. PROVIDE AIR CHAMBERS TO EACH FIXTURE AS REQUIRED. 11. PROVIDE CLEAN OUTS (WITH ESCUTCHEONS AS REQUIRED) AT THE BASE OF ALL WASTE AND /OR VENT STACKS. PROVIDE PITCH PANS & LEADS FLASHING FOR ALL SANITARY SYSTEM VENTS. 12. ALL DRAINING PIPES 2 "0 OR SMALLER TO BE SLOPED 1/4" PER FOOT. 13. ALL DRAINING PIPES 3 "0 OR BIGGER TO BE SLOPED 1/8" PER FOOT. 14. PLUMBING CONTRACTOR MUST VERIFY LOCATION OF PIPE LINES IN RELATION TO FOOTINGS AT FOUNDATION PLAN. IF THERE IS ANY CONFLICT MUST NOTIFY THE ARCHITECT OR ENGINEER PRIOR COMMENCING WORK. 15. PLUMBING CONTRACTOR TO PROVIDE AIR CHAMBERS TO ALL PLUMB'G FIXTURES 16. ALL FIRE RATED FLOOR & WALL PENETRATIONS SHALL BE PROPERLY PROTECTED FROM FIRE, SMOKE & WATER PENETRATION, BY FILLING VOIDS BETWEEN PIPE & WALL /FLOOR SLEEVES W/ FIRE -RATED FOAM, TO ACHIEVE THE SAME RATING AS WALLS OR FLOORS AS PART OF ANY PLUMBERS WORK. 17. STUDOR MINI -MAX AIR ADMITTANCE VALVES /VENTS MAY BE USED AS AN ALTERNATE TO VENT PIPING THRU ROOF, WHERE ACCEPTABLE BY PLUMBING OFFICIAL AND AS LOCAL CODES DICTATE. INSTALL AS PER MANUF'S. SPECIFICATIONS. c.o.(2 way) 9' -0" COVERED PATIO a) I io I I open patio I I 6" I , 01 3/4" HOSE -BIBB W/ SHUT OFF VALVE open patio J z 0 L_ D < Q 6" 717. I ip 3" 1350GAL. SEPTIC \ TANK & 1000 S.F. 4 "SAN. LINE TO SEPTIC TANK DRAINFIELD (c.o's SPACED @75' O.C.) (SEE SPECS. BELOW) -- -- -- -- - - -- PLUMBING FIXTURE CONNECTION SCHEDULE MARK DESCRIPTION DRAIN WATER REMARKS COLD HOT LABELED WATER CLOSET -TANK 4" 1/2" N/A 00 " LAVATORY - COUNTERTOP 1-1/2" 1/2" 1/2- " BATH TUB 1-1/2-(2-) 1/2" 1/2- SEE NOTE 4 HEAT TRAP KITCHEN SINK 1 -1/2" 1/2" 1/2" W /GARBAGE DISPOSAL *5o�In DISHWASHER 1" N/A 1/2" SEE NOTE 1 " CLOTHES WASHER 2" 1/2" 1/2" SEE NOTE 2 " REFRIGERATOR N/A 1/2- N/A ICE MAKER SERVICE " SHOWER 2" 1/2" 1/2" SEE NOTE 4 �C�E0 STORAGE : 65 GAL. O ` 0 - Z INSTALL DRIP PAN AT ENERGY FACTOR 0.89 FU w - ¢ BASE OF WATER HEATER o 3 O AS PER FBC 4614 18C TO 7 GENERAL NOTES 1. CONNECT DRAIN TO GARBAGE DISPOSAL WITH FLEXIBLE TUBING. 2. DRAIN AND HOSE BIBBS (2) INSTALLED IN RECESSED MOUNTED SERVICE BOX. 3. PROVIDE VACUUM BREAKER. 4. PROVIDE ANTI -SCALD VALVE. 5. 2" UNDER SLAB 5 "CONC. FLOOR POUR (4" MIN.) W /6x6,10/10 W.W.M., FULL LIMITS EXIST. EXCAVATED MATERIAL - BACKFILLED UPON COMPLETION CAP FOR FUTURE 12 "to 14" MATCH EXIST. F.F.E.(FLUSH) EXIST. 5" CONC. SLAB 6MIL. VAPOR BARRIER OVER TERMITE TREATED BAC KFI LL SAN. PIPING FLOOR -CUT REPAIR SCALE N.T.S. (AS APPLICABLE) CONNECTION SOLAR BY 10- 15 -09, REV. PER STRUCT. CAP FOR FUTURE OR HEAT . RECOVERY n CONNECTION SOLAR OR HEAT RECOVERY 00 T RELIEF VALVE /LINE 1 5 HOT WATER - 11 COLD WATER N .- LINE FROM H.W.H. TO HEAT TRAP a: DISCHARGE TO DRAIN PAN OR U *5o�In PROVIDE AIR -GAP AT EXTERIOR WV) TERMINATION C'4 (6 HEAT TRAP H.W.H. rn L. v L. 'c P & T RELIEF PIPE TO ELECTRIC WATER HEATER S 0 a) o _a OUTSIDE BLDG TERMINATE 4.5KW, 240/1/60 �C�E0 STORAGE : 65 GAL. O ` 0 - Z INSTALL DRIP PAN AT ENERGY FACTOR 0.89 FU w - ¢ BASE OF WATER HEATER o 3 O AS PER FBC 4614 18C TO 7 V) 6" ABOVE GRADE F - - - - - - - c n 1 " PVC DRAIN PAN (DRAIN) FLOOR L C a 0 6 WATER HEATER PIPING DETAIL N.T.S. TO CONDENSATE DRAIN LINE A/C UNIT DRAIN CONNECTION INSTALLATION OF PIPING TO CLEAR \ FILTER PULL OUT AREA & SERVICE �J REMOVABLE PANELS CONDENSATE DRAIN DETAIL N.T.S. (A.H.U. CONNECTION) t! REVISIONS BY 10- 15 -09, REV. PER STRUCT. CW. O LL- w U Z Z o w� 1- 0 00 LL ow¢ w z w uiW vw� z� W-1`i DON �_� w Ina . �N N : >- r 00 ;. t? o . Z i C m = a 6 �,�. DATE AUG., 2009 SCALE 1/4"= 1 ' -0" BY C.R.W. JOB AU -0943 00 cU 5 0 N .- U N a: 010 U *5o�In LO WV) C'4 (6 rn L. v L. 'c ca S 0 a) o _a in �C�E0 O ` 0 - Z '' FU w - ¢ a� 7 o 3 O _ V) U-) -5 5 c n L C a 0 6 U Ina . �N N : >- r 00 ;. t? o . Z i C m = a 6 �,�. DATE AUG., 2009 SCALE 1/4"= 1 ' -0" BY C.R.W. JOB AU -0943