Loading...
09-811-016EXISTING 24'-0" I I I I I II--1 1 I I I I I I L - - -� L - - --� I existing r I REMOVE EXISTING ROOF SHINGLES W /IN TRUSS 1 I I LIMITS (FIELD COORD.) — 1 I 1 I I I 1 1 L-- - - - - -- 1----------- Lm �� - JJ -V IV -V 1/4"=V-0" = FIELD VERIFY & MATCH 7, -6„ o EXISTING OVERHANG, PRIOR N TO TRUSS FABRICATION in excess of 19/32 Inches shall be fastened to the supporting — 1------ - - - - -- -- ----------- three in each eighth -inch board at each support. more than six inches on center over all supports, including `V the blocking. Nail spacing over gable ends shall not exceed Wood based structural use panel roof sheathing shall be rated four inches on center. for Exposure 1, have a minimum nominal thickness of 19/32 Inches and shall be continuous over two or more spans with Nails shall be hand driven 10d common nails (0.148" diameter face grain perpendicular to supports. Panel roof sheathing by 3" long with a 0.312" diameter full round head) or power shall be provided with a minimum of 2" x 4" edgewise blocking driven 8d nails of the same dimensions (0.148" diameter by 3" at all horizontal panel joints with edge and end spacing in long with a 0.312" diameter full round head). accordance with manufacturer's specifications, for a distance Diaphragm Boundaries shall be clearly identified on the design drawings. All roof sheathing acting as a diaphragm shall be attached to Fastening of up to and including 19/32 inches roof sheathing a minimum 2 inch thick nominal member with its depth equal to panels shall be fastened to the su pp ortin g structural member or one size greater than the intersecting top chord. This with less than 8d common nails spacing six inches on center shall be achieved with a continuous structural sub- fascia or over all supports, including the blocking. Nail spacing over blocking between framing members where a soffit is provided gable ends shall not exceed four inches on center. - at 4 inches on center with nails as required for the Nails shall be hand driven 8d common nails (0.131" diameter appropriate thickness of sheathing. by 2 -1/2" long with a 0.281" diameter full round head) or 0) power driven 8d nails of the same dimensions (0.131" diameter 1 by 2 -1/2" long with a 0.281' diameter full round head). C -2:,(.3 V) ° T.O. = 8' 1 "A. F. F. 0 CC F_ U T. .B= 8 —1 "A.F F. Ld I STRAP "B ", SEE I I ' : TRA CLG LIMITS Z l NOTES BELOW I'�•�'� w 1 CD I 20' -1 " I _ o LL. • �� �•�� I� I� m f I I� o W 0- I� W 0- o �_1 I I� I o 00 I�; o �r N X J f� (!I U Cn I BRA Q N °' } Q LATERAL ING ( ROW) C4 II U0 I In En N U' I I �: I I M •' TRA CLG LIMITS i I LL Q Q I:: nain re iden e I I:::�;:. I ao R00 RID E LIN R00 RID E LI E 3.5:12 SLOPE oo I,..: N II II m 1 o NN I.• . I Cn w (n w 1 I 1 I� 0 0 U U • I W p LLI O OJ N N _ I:..: to 00 (n w N ILL! 1 I I• '' ( ) w Z I : U) — Lh N J Ili N� '• • m Lf m LL_ Ld [if1 I a Of a Ln RN X w T.O. 13 T.0.13= F. = 8' 1 "A. F. F. 8'— 1 "A. F — 1------ - - - - -- ; 1 IIAITC: /lC CVICTIAIh C`/"1['['IT o. E -A A iv STRAP "A "„ SEE REMOVAL„ FIELD VERIFY LIMITS PRIOR NU1t5 �tLUw TO DEMOLITION SCALE: 1/4"=-0" ' -0" ROOF FRAMING PLAN PROVIDE 1/8 " ' � SPACING AT V1 PANEL EDGES PREFABRICATED WOOD TRUSSES 24' ON CENTER SEE ROOF PLAN 4' x 8' CDX PLYWOOD SHEATHING MIN. 19/32" THICK - MAX. SPAN 24' x!+11 PROVIDE 2 "x4" BLOCKING 0 ALL PLYWOOD SEAMS, 48' BACK OF CABLE END. NAIL SEAM w/ 10d 0 4 "o.c. EA. SIDE OF SEAM. 11-V ... . ' LATERAL BRACING SEE DETAIL 2'x8" WOOD FASCIA SEE ON THIS SHEET. TYPICAL WALL SECTION NAILED W/ 2 -16d NNLS 0 EACH TRUSS 8d NAILS AT 6 "o,c. AT PANEL EDGE AND INTERMEDIATE SUPPORT 1/16" SPACE AT PANEL ENDS 4'o.c. 9 GABLE ENDS FIRST 48" BACK ROOF SHEATHING DETAIL N.T.S. Roof Sheathing Notes Board roof sheathing shall have a net thickness of not less AUG., 2009 than three - fourths inch when the span is not more than 28 1/4"=V-0" inches or 5/8 inch when the span is not more than 24 inches, Fastening of roof sheathing panels with a nominal thickness shall have staggered joints and shall be nailed with 8d in excess of 19/32 Inches shall be fastened to the supporting common nails not less than two in each six -inch board nor structural member with less than 10d common nails spaced no three in each eighth -inch board at each support. more than six inches on center over all supports, including `V the blocking. Nail spacing over gable ends shall not exceed Wood based structural use panel roof sheathing shall be rated four inches on center. for Exposure 1, have a minimum nominal thickness of 19/32 Inches and shall be continuous over two or more spans with Nails shall be hand driven 10d common nails (0.148" diameter face grain perpendicular to supports. Panel roof sheathing by 3" long with a 0.312" diameter full round head) or power shall be provided with a minimum of 2" x 4" edgewise blocking driven 8d nails of the same dimensions (0.148" diameter by 3" at all horizontal panel joints with edge and end spacing in long with a 0.312" diameter full round head). accordance with manufacturer's specifications, for a distance at least four feet from each gable end. The allowable spans Diaphragm Boundaries shall be clearly identified on the design drawings. All roof sheathing acting as a diaphragm shall be attached to Fastening of up to and including 19/32 inches roof sheathing a minimum 2 inch thick nominal member with its depth equal to panels shall be fastened to the su pp ortin g structural member or one size greater than the intersecting top chord. This with less than 8d common nails spacing six inches on center shall be achieved with a continuous structural sub- fascia or over all supports, including the blocking. Nail spacing over blocking between framing members where a soffit is provided gable ends shall not exceed four inches on center. and shall be effectively nailed to said structural sub - fascia at 4 inches on center with nails as required for the Nails shall be hand driven 8d common nails (0.131" diameter appropriate thickness of sheathing. by 2 -1/2" long with a 0.281" diameter full round head) or 0) power driven 8d nails of the same dimensions (0.131" diameter by 2 -1/2" long with a 0.281' diameter full round head). C CONT. LATERAL BRACING AS REGO oao o. SHEATHING DIAG BRACING 45• COMPRESSION WEB SLOPING DR VERT DIAG BRACING CONT LATERAL BRACE NAILED TO OPPOSITE SIDE IF WEB TO PREVENT LATERAL CEILING MOVEMENT - AT 20' D.C. DIAGONALS FORM BRACED BAY AT 20 FT CONT LATERAL INTERVALS BRACING LOCATED REPEAT AT ON OR NEAR BOTH ENDS PANEL POINT (s' TO 10' D.C.) BOTTOM CHORD 45' OF TRUSSES (TYP) WOOD TRUSSES SHALL BE BRACED AND ERECTED IN ACCORDANCE WITH THE 'TRUSS PLATE INSTITUTE' BRACING WDDD TRUSSESI COMMENTARY AND RECOMMENDATIONS, BWT -76, BRACING IN THE PLAN OF THE WEB MEMBERS I n, THE TRUSS FABRICATOR SHALL PROVIDE AND LOCATE CONTINUOUS LATERAL BRACING FOR EACH TRUSS WEB MEMBER AS REQUIRED. IC. LATERAL BRACING SHALL BE RESTRAINED BY DIAGONAL BRACING (MIN, 2' THICK NOMINAL LUMBER). THIS BRACING IS TO BE CONTINUOUS, c. A MINIMUM OF TWO ROWS OF DIAGONAL BRACING IS REQUIRED, ONE AT EACH VERTICAL WEB MEMBER CLOSEST TO BEARING LOCATIONS. THE BOTTOM CHORDS SHALL BE BRACED BY CONTINUOUS LATERAL BRACING SPACED AT B TO 10 FEET, NAILED TO TOP OF THE BOTOM CHORD. DIAGONALS PLACES AT 45• TO THE LATERAL BRACES SHALL BE LOCATED AT EACH END. IF BUILDING EXCEEDS 60 FEET IN LENGTH, DIAGONAL BRACING SHOULD BE REPEATED AT 20 FOOT INTERVALS. TOP CHORD BRACING I a. IF PLYWOOD DECKING IS APPLIED DIRECTLY TO TOP CHORD, PROPERLY LAPPED AND NAILED TO DEVELOP DIAPRAGHM ACTION, BRACING IS NOT REQUIRED, b. IF PURLINS ARE USED, DIAGONAL TOP CHORD BRACING IS REQUIRED AT EACH END, IF BUILDING EXCEEDS 60 FEET IN LENGTH, DIAGONAL BRACING SHOULD BE REPEATED AT 20 FOOT INTERVALS. WOOD TRUSS BRACING DETAIL SCALE NT.S. TRUSS DESIGN STANDARDS : (AS PER TRUSS MANUF.) ASCE 7 -05 MUST BE UTILIZED FOR WIND LOADS, DESIGN WIND VELOCITY= 146 MPH., 1 =1.0, EXP. =C DESIGN LOADS /TRUSSES , LIVE /DEAD LOADS = 55 2" X 4" S.P. #2 VERTICAL STRUT FASTENED TO TRUSS TOP AND 19/32" THICK PLYWOOD BOTTOM CHORD WITH THREE- 16D-7 r ROOF SHEATHING NAILS, CLINCHED + FASTEN CROSS- BRACING TO WOOD STRUT WITH THREE - 16D NAILS 2" X 4" S.P. 12 _ CROSS- BRACING FASTEN CROSS- BRACING TO TRUSS WEB MEMBER WITH THREE - 16D NAILS 2" X 4" S.P. #2 CROSS- BRACING FASTEN CROSS- BRACING TO WOOD STRUT WiTH THREE - 16D NAILS 1 "X4"S.P.#2 LATERAL BRACING WOOD TRUSSES AT 24" O.C. CROSS BRACING DETAIL N.T.S. (2) 16d DUPLEX NAILS EACH MEMBER 2 x 4 CONT. LATERAL WOOD BRACING NAILED TO BOTTOM CHORD MAXIMUM 8' SPACING AND AS REQUIRED BY TRUSS MANUFACTURER ®'I SPLICES PRE- FABIWOOD ENGINEERED I WOOD TRUSSES 24' ON CENTER LATERAL BRACING DETAIL N.T.S. i') GENERAL NOTES &SPECIFICATIONS GENERAL ROOFING NOTES: * 5/8" CDX PLYWOOD USED FOR ROOF DECKING (APA RATED, 40/20 — 19/32" SIZED FOR SPACING) FOLLOWED W/ TAR PAPER & DECORATIVE ASPHALT SHINGLES * PRE — FABRICATED ROOF TRUSSES SET @ 24" O.C. (SUPPLY MANUF. DRAWINGS) * DECORATIVE ASPHALT SHINGLES — STYLE & COLOR PER OWNER'S SPEC'S., VERIFY PRIOR TO INSTALLATION * PROVIDE OVERHANGS AS PLAN INDICATED, AROUND PERIMETER, VENT W/ 4" CONT. VENT STUCCO SOFFIT AREAS, FINISH TO MATCH EXT. FINISH OF RESIDENCE * OWNER / CONTRACTOR SHALL SUBMIT 3 COPIES OF ALL DETAILED SHOP DRAWINGS FOR TRUSS FRAMING & ROOF CONSTRUCTION BEFORE PROCEEDING W/ INSTALLATION * CONTRACTOR TO FIELD VERIFY ALL BLDG. DIMENSIONS, MASONRY OPENINGS & ELEVATIONS, PRIOR TO CONSTRUCTION OR FORM —WORK, ANY CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER. * ALL EXIST. CONDITIONS HAVE BEEN PREPARED FROM THE MOST RELIABLE INFORMATION AVAILABLE TO THE ENGINEER, CONTRACTOR SHALL VERIFY ALL EXIST. CONDITIONS PRIOR TO CONSTRUCTION. ROOF DECKING & FINISH: i 5/8" CDX PLYWOOD TO BE USED AS ROOF DECKING, FOLLOWED W/ TAR PAPER & DECORATIVE ASPHALT SHINGLES, BASE ANCHOR SHT. TO BE #30 FELT LAPPED 2" & TURNED UP, VERT. SECTIONS A MIN. OF 4 ". DECKING NAILED 4" O.C. ALONG EDGES & 4" O.C. ON INTERMEDIATE LINES W/ 8d. RING —SHANK NAILS. BASE COURSE SHALL BE NAILED W/ NON— CORROSIVE SMOOTH SHANK NAILS SHANK DIA. OF 0.118" OR LESS. NAILS SHALL BE APPLIED THRU TIN —CAPS, 2" DIA. & 32GA. SHT. MTL., NAILS SHALL BE SPACED ® 6" O.C. IN DIRECTIONS OF ROLL & 12" O.C. ACROSS WIDTH OF ROLL. MAIN BLDG. ROOF AREA : (STRAP "A ") MAIN ROOF = 1954.80 OVERHANG = 150.60 REQ'D. OVERALL= 2405.40# HURR. STRAP WRAP OVER TOP OF ECH. TRUSS & CAST INTO CONC. TIE —BEAM, USE (1) SIMPSON STRONG —TIE DETAL20 STRAP, EMBEDDED TRUSS ANCHOR W/ TRUSS SEAT, NAILED W/18 -10d. NAILS PER TRUSS (OR APPROVED EQUAL) ALLOWABLE = 2480# TRUSS SPECIFICATIONS & BRACING: 1. WHERE THE CLG. IS ATTACHED TO THE UNDERSIDE OF THE TRUSS BTM. CHORD, THE TRUSSES SHALL BE LATERALLY BRACED W/ 2 "x4" P.T. WD. MEMBERS NAILED TO THE UPPER SIDE OF THE TRUSS BTM. CHORD, SPACE AT 6' -0" O.C. & NAILED W/ (2) 16d. COMMON NAILS AT ECH. INTERSECTION. THIS BRACING SHALL BE NAILED AT ECH. END & AT 20' O.C. 2. ERECTION OF TRUSSES LONGER THAN 35' (OVERALL LENGTH), OR TALLER THAN 6' (OVERALL HGT.) SHALL BE SUPERVISED BY A BLDG. CONTRACTOR. A LETTER FROM THE SPECIAL INSP. SHALL BE SUPPLIED TO THE CITY BLDG. DEPT. 3. ROOF TRUSSES SHALL BE DESIGNED BY A CERTIFIED TRUSS MANUF., PLANS FOR TRUSSES AND /OR SHOP DWGS. SHALL BE SUBMITTED TO THE CITY & ENGINEER FOR REVIEW AND APPROVAL. PLANS ONCE APPROVED SHALL TAKE PRECEDENCE OVER ROOF FRAMING PLAN INCLUDED. TRUSS DWGS. SHALL INCLUDE ALL PERTANENT INFORMATION RELATING TO TRUSS FABRICATION, BRACING, ANCHORAGE, ETC... EXIST. ROOF AREA (WD. TO WD.) : (STRAP "B ") HURR. STRAP NAILED TO UPPER TRUSS, THRU EXIST. WD. DECKING ATTACHED TO EXISTING TRUSS BELOW„ USE (1) SIMPSON STRONG TIE HTS -16 STRAP AT ECH. EXISTING TRUSS CROSSING BELOW„ NAILED W/16 -10d. NAILS PER STRAP (OR APPROVED EQUAL) ALLOWABLE = 1260# I : )uU I h iViIAMI DING DEPT. STRUCTURAL SECTiON aPPROVED BY:,______��F 4, REVISIONS BY 0. O LL W Z Z O w< 0 W:2 Q w a M Q�Lv Z w WWI UW� z2� W J `i C) OF Cl) W DATE AUG., 2009 SCALE 1/4"=V-0" W C.R.W. JOB AU -0943 SHT /� CO `V c S 0 O N U a) U (D _, .— 0 In V) > o _ `o� .L W 0 In LL O ■ O M C �z C L) N 0 ° 0) Q 0 3 3 Lo V/ ^ ♦ C -2:,(.3 V) L U 0 CC F_ U DATE AUG., 2009 SCALE 1/4"=V-0" BY C.R.W. JOB AU -0943 SHT S -3 1 4