13-452-095I/
PLUMBING NOTES
i.0 GENEBAL
1.1 PROVIDE FURNISH AND INSTALL') ALL NECESSARY
MATERIALS AND LABOR FOR A COMPLETELY OPERATIONAL
PLUMBING SYSTEM AS SHOWN ON THE DRAWINGS AND
HEREIN SPECIFIED. INSTALL IN ACCORDANCE WITH THE
2010 FLORIDA BUILDING CODE AND LOCAL ORDINANCES.
1,2 SCOPE OF WORK :
PROVIDE THE FOLLOWING COMPLETE SYSTEMS
A. SANITARY AS SHOWN.
B. DOMESTIC COLD, HOT AS SHOWN.
1.3 GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS
AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM
DATE OF ACCEPTANCE.
2.0 96MR
2.1 PROVIDE SHUT—OFF VALVES FOR EACH FIXTURE AND AIR
CHAMBERS WHERE SHOWN AND WHERE REQUIRED FOR
PROPER PERFORMANCE OF THE SYSTEM.
2.2 PROVIDE DIELECTRIC FITTINGS TO CONNECT PIPING TO
EQUIPMENT OR OTHER PIPING OF DISSIMILAR METALS.
USE CLAMPS AND FASTENERS OF SIMILAR METALS OR
ISOLATE FROM PIPING, ISOLATE PIPING FROM CONCRETE
SLABS AND WALLS TO PREVENT CORROSION.
2.3 PIPING
2.3.1 DOMESTIC COLD AND HOT WATER:
HARD DRAWN COPPER TYPE "M" WITH SOLDERED JOINTS,
VALVES:
125 PSIG MIN. WOG BRONZE VALVES
NIBCO/SCOTT T-122 OR S122 OR EQUAL.
2.3.2 SANITARY WASTE AND VENT:
SCH. 40 P.V.C. D.W.V. PIPE & FITTINGS.
2.3.2 VALVES
GATE VALVES:
125 P.S.I. WORKING PRESSURE.
NIBCO/SCOTT T-122 OR S122 OR EQUAL
3.0 EXEQLMQN
3.1 SEPARATE ALL PIPING FROM CONCRETE BY USING
SLEEVES THRU WALLS AND FLOORS. CAULK ANNULAR
SPACE WITH APPROVED FIRE RATED CAULKING.
3.2 PROVIDE DIELECTRIC COUPLINGS AND FITTINGS WHEN
JOINING DIFFERENT METALS.
PLUMBING FIXTURE SCHEDULE
SYMBOL
FIXTURE TYPE
TRAP
SIZE
C.W.
H.W.
MAXIMUM FLOW RATE TABLE 604.4
WC;
WATER CLOSET
3'
1/2'
-
1.6 GALL. PER FLUSHING CYCLE
5H
SHOWER
21
1/21
1/21
2.5 GPM @ 80 PSI
5T
BATH TU5
11/21
1/2'
1/2,
2.5 GPM 0 80 PSI
L14V
LAVATORY
11/2'
1/2'
1/2'
2.2 GPM, @ 60 PSI
All plumbing fixtures shall comply with -FPC 2010 table CONN. NEW 3' SAN.
604.4 max, flow rate TO EXIST. 3' FIELD
VERIFY EXACT ELE
'CNN. NEW I" C.I.U. TO EXISTING
WATER 6ERV. VALVE OUT511DE
IELE) VERIFY EXACT LOCATION
TO EXIST. SEPTIC
t A. 11 /
3/4" TO EXISTING SYSTEM
SERVING THE HOUSE
:_W 2' VTR �3/
SANITARY WASTE ISOMETRIC
3/4" BRONZE BALL
VALVE EXISTING
3/4" C,W,
3/4" UNION
TANKLESS WATER HEATER
TANKLE55 ELECTRIC WATER
HEATER MANUF,5Y TITAN,
MODEL N-160,1&KW-10AMP.
240V.-1-60
L
L
LA.
0
z
0
z
0
D
P�
0
U-i
W_
C.
Id
M
0
UJ
1A
0
Uj
V)
D
Ly
W
X
CC
Z
0
p-
L'i
CJ
z
la
0.
V)
0.
ca_j
U)
Lj
V)
0
ORLANDO RANGEL P.E. No. 60225 <
9940 S.W. 37 STREET
bi
MIAMI,FLORIDA 33165 TEL 786 547 3517 1 �T
REVISIONS B
B�'