13-452-047ASHRAE RESIDENTIAL MULTI - FAMILY COOLING LOAD CALCULATIONS 0 0.35 10 SIMPLIFIED FROM CHAPTER 26 OF THE FUNDAMENTALS HANDBOOK 1993 PARTITIONS: INSIDE OR SHADED 208.0 0.08 10 166 383 LATITUDE 25 DEG.NORTH JOB NAME: LUIS RODRIGUEZ INDOOR DESIGN TEMPERATURE CLEAR GLASS = 24.9 SHADE TYPE * JOB NO.: 002 -13 SUMMER: 75 0 0 DATE: MARCH22 2013 WINTER` 70 51.0 85.8 UNIT TYPE: ZONE 2 KITCHEN OUTDOOR DESIGN TEMPERATURE ( SQ.FT. ) 152.5 NW # OF BEDRMS: 1 SUMMER: 91 0 ## OF STORIES: 1 WINTER: 47 0 FLOOR AREA: 613.0 DAILY RANGE: M L, M or H 0.0 44.8 1.0 0 0 E 1 0 0.0 85.8 U FACTOR E.T.D. COOLING HEATING 0 GROSS NET 0.0 85.8 1.0 EXT. WALLS N 96 47 0.20 9 85 216 & DOORS NE 0 0 0.20 9 0 0 4 2 0.8 A/C PER H] 1 & E 0 0 0.20 15 0 0 * C -------- - - - SE 0 0 0.20 15 0 0 2,030 S 206 154 0.20 12 368 706 21,823 3,779 SW 0 0 0.20 15 0 0 TOTAL HEAT W 184 133 0.20 17 452 612 NW 0 0 0.20 17 0 0 ROOF /CEILING: ATTIC 613 0.05 43 1,318 705 FLOOR & CEILINGS 0 0.35 10 0 0 PARTITIONS: INSIDE OR SHADED 208.0 0.08 10 166 383 * A ------------ SOLAR & TRANSMISSION SUB -TOTAL NE 1 0 0.0 2,305 2,406 GLASS TYPE: CLEAR GLASS = 24.9 SHADE TYPE * 1 NO INTERIOR SHADE SHADING TYPE:( * ) 1 0 0 2 DRAPES OR BLINDS S.0 = 1.0 U = 1.0 51.0 85.8 3 ROLLER FULL DRAWN TOTAL GLASS AREA ( SQ.FT. ) 152.5 NW 1 0 0.0 60.8 ORIENTATION SH.TYPE $ SHADED AREA E.T.D Sc BTU /HR BTU /HR N 1 0 49.0 27.8 1.0 1,362 1,127 NE 1 0 0.0 60.8 1.0 0 0 E 1 0 0.0 85.8 1.0 0 0 0 CFM @ 400 1TON - - -- 973 CFM S.A. TONS ---- - - - - -- - -- 2.4 TONS AVER.CFM /SQ.FT - -- 1.59 CFM /SQ.FT. HEATING BTUH - - -- 7,864 BTUH SQ.FT/AVER.TON - -- 252 SQ.FT. /TON HEATING KW. - - - - -- 2_3 KW SE 1 0 0.0 74.8 1.0 0 S 1 0 52.5 44.8 1.0 2,352 1,208 SW 1 0 0.0 74.8 1.0 0 0 W 1 0 51.0 85.8 1.0 4,376 1,173 NW 1 0 0.0 60.8 1.0 0 0 HORIZONTAL U = 0.4 0.0 164.8 0.67 0 0 S 1 0 0.0 44.8 1.0 0 0 E 1 0 0.0 85.8 1.0 0 0 W 1 0 0.0 85.8 1.0 0 0 * B ------ - - - - - -- GLASS SOLAR TOTAL 8,090 3,508 PEOPLE APPLIANCES INFILT.: DUCT LOSSES 4 2 0.8 A/C PER H] 1 & 8 X 5 X 82 CFM 225 = 1600 1,800 8,000 1,412 216 * * * * * ** * * * * * ** 2,030 * * * * * ** * C -------- - - - --- INTERNAL LOADS 11,428 2,030 TOTAL SENSIBLE HEAT FOR UNIT SELECTION = LATENT HEAT DUE TO INFILTRATION - 21,823 3,779 7,943 LATENT HEAT = 7,379 BTUH TOTAL HEAT - - - - - -- 29,203 BTUH CFM @ 400 1TON - - -- 973 CFM S.A. TONS ---- - - - - -- - -- 2.4 TONS AVER.CFM /SQ.FT - -- 1.59 CFM /SQ.FT. HEATING BTUH - - -- 7,864 BTUH SQ.FT/AVER.TON - -- 252 SQ.FT. /TON HEATING KW. - - - - -- 2_3 KW FORM RESCLO186 - RESIDENTIAL COOLING LOADS - Revised 06/24/89 t K } !� p��y,r a•4 FORM RESCLO186 - RESIDENTIAL COOLING LOADS - Revised 06/24/89