Loading...
13-452-046TABLE 402A BUILDING COMPONENT PERFOMANCE CRITERIA' INSTALLED VALUES: U- Factor < 0.65 U- Factor Windows (see Note 2): SHGC = 0.30 SHGC Air leakage %of CFA < =20% _- _ To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 efm /sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & Skylights, _ U- Factor < 0.75 _ — % of CFA = U- Factor = Doors: Exterior door U- Factor U- Factor < 0.65 Floors: Slab -on -grade No requirement _ R -Value -, .... Over unconditioned s aces see Note 3 P__.._( -�__ _.._. R -13 403.2 _ Walls - Ext. and Adj. (see Note 3): _ Frame R -13 1 R- Value= �3 Mass (see Note 3) i marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R -2 + accessible manual Interior of wall: R -7.8 R -Value = Exterior of wall: R -6 R -Value = Ceilings (see. Notes 3 & 4) R =30 R -Value = Test report Reflectance 0.25 Reflectance = �7 25 Attached? Yes /No Air distribution system (see Note 4) efficiencY = 78 % (82 % after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Ductwork & air handling unit: Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification Location: A I I i G. Cooling /heating equipment Unconditioned space Not allowed Test report Conditioned space Electric heat>10kW_ must be divided into two or more stages. 3 Attached? Yes /No Duct R-value R- value?6 R -Value Air leakage On On < 0.03 �-z Qn_ conditioning systems (see Note 5) SEER = 13.0 T SEER _Air Heating system _ _ pp 1 Heat pump (see Note 5) Cooling: SEER = 13.0 SEER = 13 Heating: HSPF = 7.7 HSPF = Gas furnace AFUE 78% AFUE _ Oil furnace AFUE 78% AFUE _ Electric resistance: Not allowed (see Note 5) Water heating system (storage type) Electric (see Note 6): 40 gal: EF = 0.92 /kt Gallons = ( ON L. , CIAAK Let) 5) ,9 � 50 gal; EF = 0.90 EF = Gas fired (see Note 7): 40 gal: EF = 0.59 Gallons = Other (describe): 50 gal: EF = 0.58 EF = (1) Each component present in the As Proposed home must meet or exceed each of the applicable performance criteria in order to comply with this code using this method; otherwise Section 405 compliance must be used. (2) Windows and doors qualifying as glazed fenestration areas must comply with both the maximum U- Factor and the maximum SHGC (solar Heat Gain Coefficient) criteria and have a maximum total window area equal to or less than 20% of the conditioned floor area (CFA); otherwise Section 405 must be used for compliance. Exception: Additions of 600 square feet (56 m2) or less may have a maximum glass to CFA of 50 percent. (3) R- values are for insulation material only as applied in accordance with manufacturers' installation instructions. For mass walls, the "interior of wall" requirement must be met except if at least 50% of the R -6 insulation required for the "exterior of wall" is installed exterior of, or integral to, the wall. (4) Ducts & AHU installed substantially leak free per Section 403.2.2.1. Test by Class 1 BERS rater required. Exception: Ducts installed onto an existing air distribution system as part of an addition or renovation; duct must be R -6 installed per Sec. 503.2.7.2. (5) For all conventional units with capacities greater than 30,000 Btu /hr. For other types of equipment, see Tables 503.2.3(1 -8). Exception: The prohibition on electric resistance heat does not apply to additions, renovations and new heating systems installed in existing-'buildings. (6) For other electric storage volumes, minimum EF - 0.97 - (0.00132 x volume). (7) For other natural gas storage volumes, minimum EF = 0.67 - (0.0019 x volume). TABLE 4028 MANDATORY REQUIREMENTS -,- T COMPONENTS SECTION _ REQUIREMENTS CHECK Air leakage 402.4 _- _ To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 efm /sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & _ Ceilings /knee walls _ 405.2.1 _ outdoor combustion air. R -19 space permitting. Programmable thermostat 403.1.1 Where forced -air furnace is primary system, programmable thermostat is required. Air distribution system 403.2 Ducts in attics or on roofs insulated to R -8; other ducts R -6. Ducts tested to O, = 0.03 by a Class 1 BERS rater. Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly / Water heaters 403.4 marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R -2 + accessible manual V OFF switch. _ Spas and heated pools must have vapor - retardant covers or a liquid cover or other means proven to reduce heal T l Swimming pool & spas 403.9 - loss except if 70% of heat from site - recovered energy. Off /timer switch required. Gas heaters minimum thermal efficiencY = 78 % (82 % after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification Cooling /heating equipment 403.6 required. Special occasion cooling or heating capacity requires separate system or variable capacity system. _ Electric heat>10kW_ must be divided into two or more stages. Lighting equipment -- 4041 At least 50% of permanently installed lighting fixtures shall be high- efficacy lamps. 2010 FLORIDA BUILDING CODE — ENERGY CONSERVATION C.5