Loading...
10-373R-001a 0 m 0 a a v_ 0 3 a 0 s N U C a 7 O Y a m T d 0 0 a I v p v c 0 0 N 0 r v 3 0 .3 Q C p �N Q L M c 5:♦ U 0 U C O E v .- a N 0 E O v O ° N o O ai N � a� � v N `v a o I o. v I-- 3 U.. w - LLJ U s 3 rn o v � c O �o a c v v U y 0 U � N a w O U N N u 0 Lu / N /w o LL W V) O o J v z c w w - U T Co Q Q! Q U Co / N t w N 0 0 I c o U E L U c U - ! v U m L p v > v r 4 c v N c E v � CL O o N 'Yn c � c � N 01 U c W V) M .v •3 C C 0 Q) U O U U E v c rn c 3 v 0 LEGEND: LIGHT SWITCH 3G 3 -WAY LIGHT SWITCH •, RECEPTACLE CEILING OUTLET �.. JUNCTION BOX (WEATHER PROOF) Q RANGE RECEPTACLE 10 WALL MOUNTED LAMP SMOKE DETECTOR W/ BATTERY BACKUP INTERCONNECTED FOR SIMULTANEUS OPERATION 0 FACTORY MOUNTED AMU CKT. BKR. Di DISCONNECT SWITCH WP. WEATHER PROOF C_FI GROUND FAULT INTERRUPTEP PROTECTION f EXHAUST FAN '® DRYER CEILING FAN WALL MOUNTED LAMP TV TV JACK v TELEPHONE JACK HOOD FAN F-E) FLUORESCENT LAMP SMOKE DETECTOR CONNECTION IXTAIL SMOKE DETECTOR SHALL NOT BE PLACED WITHIN 3FT. OF ANY A/C GRILL NOTE: SMOKE DETECTOR SHALL BE HARDWIRED (110 VOLT TYPE) TO A NON- SWITCHABLE LIGHTING CIRCUIT WITH BATTERY BACK -UP AND SHALL NOT BE CONNECTED ONTO THE LOAD SIDE OF GROUND FAULT CIRCUIT INTERRUPTER. ALL SMOKE DETECTORS WITHIN EACH UNIT SHALL BE INTERCONNECTED ELECTRICAL NOTES I. ALL ELECTRICAL WORK SHALL BE DONE IN COMPLIANCE WITH THE FLORIDA BUILDING CODE AND NATIONAL ELECTRIC CODE. 2. PROVIDE GROUND FAULT CIRCUIT PROTECTION AT ALL BATHROOMS AND ALL EXTERIOR LOCATIONS. 3. PROVIDE WEATHER PROOF COVER FOR ALL ELECTRICAL RECPTACLES LOCATED AT EXTERIOR. 4. ALL WIRING SHALL BE DONE IN ROMEX OR IN CONDUIT. 5. ALL ELECTRICAL EQUIPMENT INSTALLED SHALL BE U.I_ APPROVED. 6. ALL ELECTRICAL EXPOSED TO THE WEATHER SHALL BE WEATHER PROOF. 1. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES. S. ALL METALLIC CONDUIT EXPOSED TO WEATHER OR IN CONTACT WITH CONCRETE SHALL BE GALVANIZED. S. IF ANY CONDITIONS OCCUR THAT ARE NOT IN ACCORDANCE WITH CONTRACT DOCUMENTS NOTIFY THE ARCHITECT. 10. PROVIDE TV AND TELEPHONE PRE -WIRE WITH JACKS AS INDICATED ON PLANS. II. SMOKE DETECTORS SHALL BE ELECTRICAL TYPE WITH BATTERY BACK AND ALL SHALL BE INTERCONNECTED. 12. UNLESS OTHERWISE NOTED ALL WIRING SHALL BE COPPER. 13. AT CONDENSING UNIT PROVIDE NEMA 3R DISCONNECT SWITCH SIZED AS PER EQUIPMENT NAME PLATE. 14. RELEASED LIGHTING FIXTURES SHALL BE TYPE IC RATED WITH NO PENETRATIONS, SEALED! OR TYPE IC OR NON -IC RATED, INSTALLED INSIDE A SEAL BOX WITH 1/2" CLEARANCE AND 3" FROM INSULATIONt OR TYPE IC RATED t 2.0 CFM FROM CONDITIONED SPACE, TESTED. METER 1.T MAIN DISC. NEMA 3R - PROVIDE 10 4 (GRD) (Cu) N 1/2" C TO CIIIP. AND 2-°x00 x I0' RODS 6' APART AND FOUNDATION REBARS - O EXIST. PNL "A" - 303/0,106(GRD) (CU) THWN N 2"C 2P/200A DISC. NQ'MA 3R (IOK AIC) ELECTRICAL RISER DIAGRAM 200 IMPS M.L.O. PANEL 120/240v 10 3W MTO- SURFACS CKT SERVES C43 P KW WIRE -COND. CKT SERVES CB P KW WIRE -COND. 01 AC -1 A.H.U. 60 2 10.0 6 - 314" C 02 AC -1 Cii. 40 2 614 18 - 11,"r- 03 04 05 ... ................. .._ ... ... RANGE _. 50 2 - --.... 12.0 ...... ....... � .'I._ .. _.. 6 - /4 C 06 WATER HEATER 30 Z 4.5 I n 0 10 - i= C 01 08 ............ _ ....... ........ ... _ . -.... .... ...._... .............- _.... 09 DRYER 30 2 5.0 10 - 1/2" C 10 GARBAGE DISPOSAL 20 1 ID _ # 12 -1/2"C II 12 DISHWASHER 20 1 1.5 # 12 - V2"0 13 SMALL APPLIANCES 20 1 1.5 # 12 C 14 REFRIGERATOR 20 1^ ^V1.0` v` .._ 12 -TV=" C ^ 15 SMALL APPLIANCES 20 1 1.5 12 - Ii2" C 16 BATH - OM 20 1 ........... 0.65 _.._.I ..... ... _ ..... ....... 0 12 -1/2"C 11 CLOTHES WASHER _ ....... 20 _. ... 1 1.5 _ ............. . ................._.. 12 - Ii2" C _ ...._. 18 _..._........ __....._.............. BATH - GFI 20 ....... _ ._.... 1 __-- ..._...... 0.65 _._ _.__._..__.....__.._ .... 0 12 - Ii2" C 19 RECEPTACLE - API 15 1 0.65 0 14 - 1/2" C 20 BATH - GPI 20 1 0.65 d 12 - I/2" C 21 RECEPTACLE - API 15 1 0.65 0 14 - V2" C 22 LIGHTS 15 1 OAS # 14 - 4" C 23 RECEPTACLE - API 15 1 0.65 0 14 - Ii2" C _. 24 ....... ......................_.._..... __ ................... LIGHTS 15 ......_... I _..._..__._.._ CAS _..... ...... _..__' -- 0 14 - t12" C 25 RECEPTACLE - API 15 1 0.65 d 14 - I12" C 26 LIGHTS 15 1 0.65 ¢ 14 - I12" C 21 RICER DINNER 20 1 1.0 0 12 - Ii2" C 28 LIGHTS 15 1 0.65 0 14 - Ii2" C 21 RECEPTACLE 20 1 0.65 u 12 - C 30 SMOKE DETECTOR 15 1 0.65 N 14 - 1/2" C 31 RECEPTACLE - API 20 1 OAS 0 12 - Ii2" C 32 LIGHTS 15 1 0.65 C 14 - Ii2" C 33 SPACE 34 SPACE 35 SPACE 36 ....... ... . ... ..... ... ........._......._... __.......... 31 SPACE 38 39 SPACE 40 SPACE 41 SPACE 42 SPACE TOTAL CONNECTED LOAD: SEE LOAD CALC. WATTS FEEDER SIZE: SEE RISER SEE LOAD CALC. AMPS - FED FROM: SEE RISER FEEDER - 3 0 3/0,10 6 (GRD) IN 2" C + NON - CONCURRENT LOAD ADDED k- THRU GPI C.S. + THRU MOTION SENSOR FLOOD CRITERIA NOBS: I. ELECTRICAL OUTLETS (RECEPTACLES AND LIGHTING) BELOW BASE FLOOD ELEVATION SHALL BE INSTALLED AT THE HIGHEST PERMITTED ELEVATION AND SHALL BE INSTALLED ON (SEPARATE) INDEPENDENT CIRCUITS FROM THOSE IN THE HABITAL AREAS 1. NO APPLIANCES OR APPLIANCE OUTLETS SHALL BE INSTALLED BELOW BASE FLOOD ELEVATION 3. A/C COMPRESSORS SHALL BE INSTALLED ABOVE BASE FLOOD ELEVATION 4. MAIN CIRCUIT BREAKER PANELS SHALL BE LOCATED ABOVE BASE FLOOD ELEVATION 5. IT IS SUGGESTED THAT YOU CONFER WITH THE POWER CO. TO LOCATE THE ELECTRIC METER TO COMPLY WITH FEDERAL EMERGENCY MANAGEMENT AGENCY REQUIREMENTS 4' CEILING E ACCEPTABLE HEFm `r NEVER HERE TOP OP DETECTOR ACCEPTABLE HERE SIDE WAIL NOTES: 4. DIMENSIONS, BHOIJJr1 ARE TO THE NEAREST EDGE CP THE DETECTOR 2tt. IN ADDITION, DETECTORS SHALL NOT BE NSTALLM WIT14N 3 FEET OF A SUPPLY AIR DIFFUSER OR PAN, NOR WITHIN 12 INCHES OF A LIGHT FIXTURE TYPICAL DETECTOR MOUNTING DETAIL (FOR INSTALLATION NEAR A WALL OR IN CEILING) N.T.S. GRADE + CALCULATIONS FOR PANEL 3W / SQ .PT. SO KW RANGE 12.0 KW DRYER 5.0 KW WATER HEATER 4.5 KW CLOTHES WASHER 1.5 KW REFRIGERATOR 1.0 KW APPLIANCES (3) 4.5 KW GARBAGE DISP. 1.5 KW DISHWASHER 1.5 KW TOTAL CONNECTED LOAD 39.0 KW FIRST 10 KW a 100% 10.0 KW REST 9 40% 11.60 KW TOTAL A/C 9 65% b5 KW TOTAL DEMAND LOAD 28.10 KW 28.10 KW / 240 v = 111.08 AMPS C -23 F • e C -28'x' i . �C -Z3 i i C -2% i........ ..,,...s' : .. .. 1 t I i _ i i F NNW C -43� - - -- C -29 NF�w C -22 i NEW NEW E { C NEW C -33� C -Z8 ' C -24 C -35 WP -1, 3 Al J. PROVIDE 2P /30A TOGGLE SWITCH 7C -Zb C -Zb . -... . C -14 C -2 C'B C -10,12 -15 '.._.....C#L .... _._.. .CFI .. i C -Z6 nJ �NORT+ GROUND FLOOR PLAN %0-&.r ©C -30 C -29 200 A DISC. NEMA 3R ELECTRIC yy METER CAN ..1 OUT BOX WITH FUSES AS PER MANUF. SPEC'S C -2,4 C.U. C -215 C -25� C -29 C -31 1/4" CIRIC14L Wow SHOWN IS NOTING UNLM Na= OTHOW161 NEW C -35 GWP A W cz w N w m x Lo J J I U z_ d. D 0 U Y MMQ 1�1 O x Lo IL U m w Q 0 z 0 w 0�1 01 z Ip O cDO U 00 J Q LL_ co �t �..� Ib 0 O z ao U O z O woo NO_U Of CD �OOOW Y N��z Q Q o0 w m UNt -1,.1 1 O' �P 'p W m d %r w. r FA Q w � LLJ > tY > x U Ow 0w U� Pmw o� W 4 ya W �j 'aLL. M Q �O h = O ~' O mr 0 SCALE DATE PROJECT NO. SHEET NUMBER Aml