14-31-007Be Crl ewk rm Um
3' DLAM u GA. GALV Duct
TO I OCP JACK u✓re acK DttAFr
DAhKR AND MECT 6QNIM
016CHAPM V AD" 010M
&A'04=
EXIST. CU.
YES
NO
DUCT SMOKE DETECTOR
25AOO
SENS CAPACITY
STU /HR
�IIIiI!,;
CFM SUPPLY
II
i�llllllllllllllllllllllllilllllllllll
�
W CM J. FM \'
ESP- IN UJG
030
FIRE RAND ROOF/FLOOR
CEILINCx ASSEMSLI'
TO IWM JAM COW
C.U. FL A
-
VOLTAGE
01119CHAME _
SMOKE CONTROL
RHEEM
v I
1.
C.U. MODEL
140 r-
SEER
14.5
LIQUID /SUCTION SIZE-IN
i r-
CL. I L__ CL. - -
TH.
A/C GOND. DRAIN 8 L 6•
ABOVE GRADE IN G EN AREA
42/01
oo;
::im'''��..:..
8'a LIVING -ROOM
I
GL- 220 CFM
EXIST 109XY11(G.D. 3 W)
i
I
I
AIDDITION
N�,4C FLOOR FLAN
SCALE 1/4' =1' -0'
HVAC DESING REQUIRES:
YES
NO
DUCT SMOKE DETECTOR
25AOO
SENS CAPACITY
STU /HR
FIRE DAMf'ER(S)
CFM SUPPLY
11000
SMOKE DAMPER(S)
v
FIRE RATED ENCLOSURE
ESP- IN UJG
030
FIRE RAND ROOF/FLOOR
CEILINCx ASSEMSLI'
80/6 -1
C.U. FL A
FIRE STOPPING
VOLTAGE
1 -60 -240
SMOKE CONTROL
RHEEM
v I
H. V. A. C. GENE RAC, NOTES
D
CL.
IZ'XiZ' Door Tramf. Grilles
w CFM
EXISt. 1m'X12'lGD. 3 W)
FAMILY -ROOM
HVAC equipment schedule
UNIT No. 2
A /C. 2.5 t.
TOTAL COOLING
CAPACITY STU /HR
25AOO
SENS CAPACITY
STU /HR
20,150
CFM SUPPLY
11000
CFM O/A I R
HEATER, KW
S.-tg
ESP- IN UJG
030
TEMP" AIR ENT. COIL
D 3/UJ5
80/6 -1
C.U. FL A
13.5
VOLTAGE
1 -60 -240
MANUFACTURER
RHEEM
COIL /A.H.U. MODEL
RHSL - FR3roTJN00A
C.U. MODEL
AHRI - I4AJM30
SEER
14.5
LIQUID /SUCTION SIZE-IN
� HVAC KEY NOTES
lO FULL SIZE pISCHARGsH PLENUM
I' DRAIN PIPE
0 THERMOSTAT
REFRIGERANT PIPES IN CEILING
ROOF GAP WITH SIRpSGREEN� TO
REFRIGERANT PIPES UP IN CEILING
THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL AND EQUIPMENT FOR A
COMPLETE H. V. A. C. SYSTEM IN ACCORDANCE WITH THESE DRAWINGS, THE SOUTH
FLORIDA BUILDING CODE AND THE LATEST EDITION OF THE FOLLOWING PUBLICA-
TIONS: (A) ANS 5-S.1 MECHANICAL REFRIGERATION (S) N .F.P.A. PAMPHLETS SO 4 SI
(C) SMACNA (D) ASHRAE.
ALL AIR CONDITIONING DUCTWORK SHALL SE ONE INCH STANDARD DUTY FOIL
REINFORCED RIBER.GLASS WITH MANUFACTURER'S LOGO PRINTED ON THE VAPOR
BARRIER.
ALL EXHAUST DUCTWORK SHALL SE CODE GAGE GALVANIZED SHEET METAL.
DUCT SIZE SHOWN ARE NOT FREE AREA.
ALL AIR DEVICES (DIFFUSERS, REGISTERS 4 GRILLES) SHALL SE ALL ALUMINUM
CONSTRUCTION, WITH EXPOSED SURFACE CHEMICALLY TREATED TO RECEIVE PAINT
TO MATCH COLOR OF SACKGcROUND SURFACE. ALL AIR DEVICES SHALL SE TITUS,
AIRGUIDE OR APPROVED EQUAL.
PROVIDE OPPOSED BLADE DAMPERS AT ALL DIFFUSERS 4 REGISTERS.
PROVIDE TURNING VANES AND EXTRACTORS ALL ELBOWS AND TAKE -OFFS.
THERMOSTATS SHALL SE COMBINATION COOLING /HEATING WITH SYSTEM COOL -
AUTO -OFF AND PAN ON -AUTO SELECTOR SWITCHES, PROVIDE TAMPERPROOF COVERS.
PAN -COIL SE MOUNTED HORIZONTAL. PROVIDE HORIZONTAL DRAIN PAN KIT.
CONDENSING UNIT SHALL SE ANCHORED TO IT'S SASE PER MANUFACTURE'S SPECS.
REFRIGERANT PIPING SHALL SE COPPER TYPE V. 3 /4'ARMAFLEX INSULATION
SHALL SE PROVIDED FOR SUCTION LINES. FILER -DRYER AND SIGHT GLASS SHALL
SE PROVIDED AT LIQUID LINES.
PROVIDE NEW FILTERS FOR FAN -COIL BEFORE STARTING. THESE FILTERS MUST
ALSO SE REPLACED PRIOR TO FINAL ACCEPTANCE, (SY OWNER)
CONDENSING
UNIT
C.U. MOUNTING DETAIL
NOTE: 3/4' ANCHOR BOLT AT �W EA"
CORNER UJ /4X4 SY 1/4' WELDED
A/C COMP. SHALL SE INSTALLED
A50VE SASE FLOOD ELEVATION.
I! \I
he
/---1/8" STAINLESS STEEL
WIRE WRAP.
Fghm
6" MIN. 0 °
2 1/2" x2 1/2" x1/4" GALV. . • _
ANGLE TYP. OF 4 (TWO PER SIDE) • • • 5�
MR
P
POWER & CONTROL
CONNECTIONS
6" MIN.
-fi— 4" MIN.
CONCRETE BASE W/
6X6— 10 /10WWF
1/2- BOLTS & NUTS
1/2" MECH. EXPANSION \
GALV. ANCHOR BOLTS. 6" MIN. `\ \
(3" LONG.)
SEAL ENTRANCE OF REFRIGERANT
LINES INTO P.V.C. PIPE W/
IMPERMEABLE, RESILENT MATERIAL
CONDENSING UNIT — MOUNTING DETAIL
NO SCALE
'AFT DAMPER
.E
T ♦ 1 116. VN„1
FROM DRYER EXHAUST
DRYER EXHAUST ROOF CAP DETAIL NTS.
1 HR. F I1;
RATED
EA. SID1
T" CLE
ALL Af
REF
LIN
FIL"
FINISH
LIQUID LINE
W/O INSULATION
SUPPL'' AIR
DUCT.
6" 0 SCHEDULE
40 P.V.C. PIPE
INCREASE SIZE
AS REQUIRED BY
LENGTH AND ROUTING
SUCTION LINE W/ 1-1/2-
ARMAFLEX INSULATION
& VAPOR BARRIER
CEILING STRUCTURE
UJ 11 HfR. FIRE RATED
S.A. DUCT SHALL BE
CONNE TE D TO F.C. UNIT
AS PER F.B.C.
FLEX. CONNECTION
AIR HANDLING [NUT.
PERFORATED CAP
PROVIDE
"SAFE -T- SWITCH" (FLOAT SWITCH)
t-101)EL 55-2 OVERFLOW SWITCH 5"r
"SMD RESEARCH INC."
IN PRIMARI' PAN AUXILLIARY OUTLET
(OR EQUIVALENT)
CONDENSATE DRAIN
W /P. TR,4P 11, PVC.
NEOPRENE PADS
V15RATION ISOLATOR
1 X1 X44 STEEL ANGLE
FRAME ATTACHED TO
FLOOR STRUCTURE
TO CONDENSATE
DRAIN LINE
f— PERFORATED Ri= MOVABLE CAP
COW IT DRAIN
TRANSPARENT PLAST
HOSE W /SS. CLAMPS.
NOTE: INSTALLATION OF PIPING TO CLEAR
FILTER FULL OUT AREA t SERVICE
REMOVABLE PANELS.
CONDENSATE DRAIN ARRANGEMENTAT
AT A/C UNIT N.T.S.
Q
0
m
r__ r1_
N_ L0
rr) 0)
Or)
J •Q�
LL
I— - If)
Ld Q
U —"
r n CE LLI Q)
U 1 LLI < < O
Z �
0
_I z N
NW§
LL LL C/)
�OV_
0 °o
lilt s'p %�
gill 4
Ctl r -
U
QC �
O O
LL �
O �c�
W Cf)
Z
Lj Q
O f-
(L O
CAD FILE: socorro
LAYER: PLUMB :J
AC -1
1 of 1