Loading...
14-31-006(NEW) O.N. ELECTRIC SERVICE FROM ELECTF,ICAL PLAN SCALE 1 %' =1' -0° TYPE: LOAD CENTER MAIN BUS: 200 SERVICE: 1 PH 3W FANEL II ii NEUTRAL: 200 VOLTAGE: 120/240 V. MAIN:200 AMP. A BRK. MOUNTING: SURFACE CALL 20 AMPS, 1 POLE CKTS. EXCEPT AS NOTED) LOCATION: SHOWN W O d O} H O lL N REMARKS Z 8 REMARKS ( N Z H O Fes- O} J O 60 2 11,800 1/2" 10 W/H -TITAN 1 2 GENE. LIGHTIN 14 1/2" * 1 15 3 4 GENE. LIGHTIN 14 1/2" * 1 15 20 1 1500 1/2 " 12 SMALL APL I ANCE(GFC I) S, 6 GENE. LIGHTIN 14 1/2 " * 1 15 20 1 1500 1/2 " 12 SMALL APL IANCECGI =C I 1 8 GENE. LIGHTIN 14 1/2 " * 1 15 20 1 * 1/211 14 GEN. LIGHTING 9 10 GENE. LIGHTIN 14 1/211 * 1 15 30 2 5400 1/2" 10 GU 11 12 DRYER 10 1/2" 5,000 1 30 13 14 6 0 2 11,040 3/4' S <W. AHU � 10 . HTR. 15 16 WASHER MACHING 12 1/2" 1,500 1 20 17 18 RANGE 6 in 12,000 2 50 20 1 * 1/2 " 14 GEN. LIGHTING 19 20 20 1 1500 1/2" 12 DI5WASHER 21 22 GENE. LIGHTIN 14 1/2" * 1 15 20 1 300 1/2" 12 MICROWAVE 23 24 REFRIGERATOR 12 1/2" 1,500 1 20 20 1 1500 1/211 12 IGEN. LIGHTING 25 26 GENE. LIGHTIN 14 1/2' * 1 15 20 1 1500 1/2' 12 BATH. RECEIPT. (GFCI) 27 28 SPACE SPACE 29 30 SPACE CONNECTED LOAD: FEEDER: SEE RISER * LIGHTING 4 RECEPTACLE FED FROM (NEW) electrical notes: I. ALL WORK SHALL COMPLY WITH THE LATEST EDITION ON THE 'NATIONAL ELECTRICAL CODE' (NEC) 4 THE 'FLORIDA BUILDING CODE' 2. ALL CABLE SHALL BE COPPER UNLESS OTHERWISE NOTED AND APPROVED. 3. OUTDOORS UNDERGROUND CONDUITS SHALL BE SCHEDULE -40 PVC UNDER PAVED AREAS. 4. CONTRACTOR SHALL FURNISHED ALL LABOR, MATERIALS AND EQUIP. FOR A COMPLETE ELEC. INST. IN ACCORDANCE WITH THE ELECTRICAL DRAWINGS AND APPLICABLE CODES AND REGULATIONS. 5. ELEC. CONTRACTOR TO COORDINATE ALL OUTLET LOCATIONS WITH BLDG. AND ARCH. FIXTURES. 6. ELCT. CONTRACTOR TO PROVIDE EMPTY CONDUITS AS REQD. FOR TELEPHONE LINES t T.Y. ANTENA. 1. ALL MOUNTING HARDWARE SHALL BE BY CONTRACTOR 8. ALL LIGHT FIXTURES AND FANS TO BE SELECTED BY OWNER, UNLESS OTHERWISE NOTED. S. CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL AND EQUIPMENT FOR COMPLETE ELECTRICAL INSTALLATION IN ACCORDANCE WITH THESE DRAWINGS. 10. COMPLY WITH THE N.Ej3. AND THE FLORIDA BUILDING CODE. 11. PROVIDE EMPTY CONDUITS AS REQUIRED FOR TELEPHONE SYSTEM. 12. OBTAIN ALL PERMITS FOR WORK UNDER THIS CONTRACT. 13. PROVIDE TEMPORARY POWER AND LIGHT OUTLETS FOR USE BY OTHER TRADES. 14. PROVIDE ALL REQUIRED CONNECTIONS FOR OTHER TRADES. 15. COORDINATE ALL OUTLET LOCATIONS WITH BUILDING ARCHITECTURAL FEATURE. 16. CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. 11. ALL CABLE SHALL BE COPPER EXCEPT WHEN NOTED OTHERWISE. 18. INDOOR CONDUITS SHALL BE EMT. IS.OUTDOOR CONDUIT SHALL BE SCHEDULE 40 PVC, MINIMUM COVER SHALL BE 24. 20. ALL MOUNTING HARDWARE SHALL BE BY CONTRACTOR 21. ALL RECEIPTS, LIGHTS, CLOSET LIGHTS AND SMOKE DECTECTORS IN BEDROOM SHALL HAVE ARC FAULT CIRCUIT INTERRUPTER PROTECTION. BEFORE BIDDING, CONTRACTOR SHALL PERFORM A THOROUGH INVESTIGATION OF ACTUAL CONDITIONS AT THE JOB SITE AND INCLUIDE ALL WORK REQUIRED TO INTRODUCE SYSTEM COMPONENTS INTO EXISTING STRUCTURES AND TO CONECTOR OR MODIFY EXISTING SYSTEMS AS INDICATED ON DRAWING OR NECESSITATED BY THE INSTALLATION PERFORM ALL SUCH WORK WITHOUT ADDITION TO THE CONTRACT COST. WHERE INDICATED ON DRAWINGS REMOVE OR RELOCATED EXISTING SYSTEM COMPONENTS AND PROPERLY PATCH AND FINISH RESULTING OPENINGS IN THE BUILDING STRUCTURE WITH THE SAME MATERIAL AS THOSE ADJACENTS TO THE OPENING. a 0 m 0 Ln� LO Worms N t J •QLo L� —i LL �0 O W — � M �UQ.. ((� Ld � c V/WQ 0 O z o) �- U JZ �w� Lcf) �O �o 0 � r It .. m r ctl QC � LO O j Q� O rQ 0(p z v �4 a O� N O (� lu t3 J 1-- � � U 0- O CAD FILE:Socorro�] LAYER: FLLG�S E -1 1 of 1