Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
11-1169R-001
GENERAL NOTES: 1 INSTALLATION SHALL BE DONE IN STRICT ACCORDANCE WITH THE FLORIDA BUILDING CODE 2007 AND NEC 2008. 2 ALL CONDUCTORS SHALL BE COPPER, THWN TYPE RATED AT 751C. 3 ALL CONDUITS SHALL BE E.M.T. UNLESS INDICATED OTHERWISE. 4 ALL RECEPTACLES SHALL HAVE AN ENGRAVED BRANCH CIRCUIT IDENTIFICATION PLATE INDICATING PANEL AND CIRCUIT NUMBER. 5 PROVIDE TYPED CIRCUIT INDEX FOR ALL NEW AND EXISTING PANELBOARDS. 6 PROVIDE ALL REQUIRED PERMITS AND PAY ALL FEES. 7 ALL BOXES SHALL BE METALLIC. 8 ALL RECEPTACLES SHALL BE 18" A.F.F. UNLESS INDICATED OTHERWISE. 9 PROVIDE A GREEN GRD. WIRE TO ALL RECEPTACLES AND FIXED EQUIPMENT. 10 CONTRACTOR MUST VISIT SITE TO BECOME FAMILIAR WITH EXISTING CONDITIONS BEFORE BIDDING THIS JOB. 11 CONTRACTOR SHALL INSTALL ALL ELECTRICAL EQUIPMENT FURNISHED BY THE OWNER OR OTHER CONTRACTOR. 12 ALL CONDUITS SHALL RUN CONCEALED U.I.O. 13 PROVIDE COVER PLATES FOR ALL OUTLETS. 14 ALL CONDUIT PENETRATIONS OF FIRE -RATED WALLS, FLOORS, AND CEILINGS SHALL BE SEALED IN ACCORDANCE WITH REQUIREMENTS OF NEC ARTICALE 300 -21 AND DETAILS I AND II ON THIS SHEET. 15 PROVIDE ALL THE REQUIRED WIRING AND CONDUff. 16 CONTRACTOR SHALL PROVIDE SHOP DRAWINGS OF THE FOLLOWING FOR ENGINEER APPROVAL A) LIGHTING FIXTURES, INCLUDING LAMPS. B) ALL ELECTRICAL COMPONENTS (SWITCHES, RECEPTACLES, CONDUITS, PANELBOARDS, TRANSFORMERS CIRCUIT BREAKERS /FUSES, ETC) C) NEW FIRE ALARM COMPONENTS (CUT SHEES AND WIRING DIAGRAM) 17 ALL ELECTRICAL SWITCHES SHALL BE 48" A.F.F. UNLESS INDICATED OTHERWISE. 18 ALL LIGHT SWITCHES SHALL HAVE AN ENGRAVED BRANCH CIRCUff IDENTIFICATION PLATE INDICATING PANEL AND CIRCUff NUMBER. 19 COORDINATE MOUNTING HEIGHT OF ALL LIGHTING FIXTURES WITH ARCHITECT. 20 SHEETS WITH NOTES IN HEXAGON ARE FOR SPECIFIC LOCATIONS. NOTES WITHOUT HEXAGON ARE GENERAL NOTES FOR THAT SHEET. 21 ALL FLUORESCENT FIXTURES SHALL USE ENERGY CONSERVATION BALLAST AND LAMPS (GE OR SYLVANNIA) 22 FOR ALL DISCONNECTS PROVIDE NEMA 1 ENCLOSURE INDOORS AND NEMA 3R ENCLOSURE OUTDOOR. 23 ALL CONDUITS RUNNING UNDERGROUND BE PVC SCHEDULE 40 1" MINIMUM AT 24" MIN BELOW GRADE. 24 ALL CONDUITS RUNNING EXPOSED IN EXTERIOR AREAS UP TO 8' -0" HIGH TO BE RIGID METALLIC CONDUff. 25 ALL CONDUITS RUNNING CONCEALED TO BE EMT TYPE. 26 ALL ELECTRICAL COMPONENTS INCLUDING CONDUCTORS, BOXES AND EQUIPMENTS LOCATED IN WET AND DAMP LOCATIONS EXPOSED TO GASES, FUMES, VAPORS, LIQUIDS OR OTHER DETERIORATING AGENTS SHALL BE APPROVED FOR THAT PURPOSE. I<ac:.WTIIm?© A.F.F. ABOVE FINISHED FLOOR FLUOR. FLUORESCENT BIKR. BREAKER GND. GROUND A.I.C. AMPERE INTERRUPTING CAPACITY C.F.I. GROUND FAULT INTERRUPTER C.B. CIRCUIT BREAKER G.T.B. GROUND TERMINAL BOX C. CONDUIT HT. HEIGHT CKT. CIRCUIT H.P. HORSE POWER CLG. CEILING HTR. HEATER CL CLOSET J.B. JUNCTION BOX COM. COMMUNICATION K.V.A. KILOVOLT AMPERES C.T. CURRENT TRANSFORMER K.V. KILOVOLT DR. DOOR K.W. KILOWATT ELE /ELECT. ELECTRIC /ELECTRICAL MAX. MAXIMUM E.F. EXHAUST FAN MIN. MINIMUM E.C. EMPTY CONDUIT M.C.B. MAIN CIRCUff BREAKER EL CL ELECTRICAL CLOSET MFR. MANUFACTURER EM. EMERGENCY MOD. MODEL EMT ELECTRICAL METALLIC CONDUIT MTD. MOUNTED EQ EQUIPMENT NEC NATIONAL ELECTRICAL CODE E.W.C. ELECTRIC WATER COOLER LTG. LIGHTING EX EXISTING U.I.O. UNLESS INDICATED OTHERWISE EXP EXPLOSION WP WEATHERPROOF OR NEMA 3R GEN. GENERATOR UL UNDERWRITERS LABORATORIES FBC FLORIDA BUILDING CODE MINI -SPLIT SYSTEM "1" (ATM RM) 0 NOTE: ALL ABBREVIATIONS SHOWN ARE NOT NECESSARILY USED FOR THIS PROJECT. ALL ELECTRICAL EQUIPMENT INSTALLED OUTSIDE TO BE TAMPER RESISTANT. 4 - #300 kcmil & 1 #1 GND THWN CU WIRE IN EACH OF 2 -3" C. 4 - 1300 kcmil THWN WIRE IN EACH OF 2 -3" C. MAIN 1 OF 1 600A K7 CAN 3600 120/240V ON3R C.W.P. #2/0 CU GND —1 ' MI 2 -5/8 "x10" \ 4 - #300 kcmil THWN CU WIRE GND RODS IN EACH OF 2 -3" C TO F.P.L. L TO BUILDING TRANSFORMER. FOUNDATION STEEL Electrical Riser Diagram LEGEND: SYMBOL DESCRIPTION SYMBOL DESCRIPTION ❑ FLUORESCENT LIGHTING FIXTURE CEILING MTD. 20A. 125V. 3 WIRES GROUND TYPE SPECIFICATION GRADE QUADRUPLEX RECEPT. MTD. 18' A.F.F., U.I.O. FLUORESCENT LIGHTING FIXTURE CEILING MTD. WITH BATTERY PACK. 20A. 125V. 3 WIRE GROUND FAULT INTERRUPTER DUPLEX RECEPTACLE, 6" ABOVE COUNTERS OR 42" A.F.F., U.I.O. ® FLUORESCENT DOWNLIGHT CEILING MTD. TYPE AS SPECIFIED. ® 20A. 125V. 3 WIREGROUNDING TYPE SPECIFICATION GRADE DUPLEX RECEPTACLE, FLOOR MTD. CEILING /WALL MTD. EXIT LIGHT. ® 208V SPECIAL RECEPTACLE OF NEMA TYPE AS INDICATED ON PLANS. PROVIDE MATCHING PLUG. CEILING /WALL MTD. COMBINATION EMERGENCY /EXIT LIGHT. UNDERGROUND CONDUIT, 2' -0" MINIMUM BELOW GRADE CONDUIT RUN CEILING /WALL MTD. EMERGENCY LIGHT. CONCEALED UNLESS INDICATED OTHERWISE. DATA/TELEPHONE OUTLET MTD 18" AFF., U.I.O. 0 CONDUIT TURNED UP TELEPHONE OUTLET MTD. 18" A.F.F., U.I.O. 9 CONDUIT TURN DOWN ® DATA/TELEPHONE OUTLET FLOOR MTD. - --A HOME RUN PANEL LPI. CIRCUIT # 3, TICK MARKS DENOTE NUMBER OF O FIRE ALARM SYSTEM PHOTOELECTRIC SMOKE DETECTOR WIRES: (U.I.O. # 12 IN 3/4" C). LONG MARKS NEUTRAL, SHORT MARKS ADDRESSABLE TYPE. HOT OR SWITCH LEGS, DOT MARKS GREEN GROUND WIRE. S� FIRE ALARM SYSTEM DUCT SMOKE DETECTOR ADDRESSABLE TYPE. 0 MOTOR, NUMBER IN CIRCLE DENOTES HORSE POWER RATING FIRE ALARM SYSTEM COMBINATION HORN /STROBE LIGHT (750/0 CEILING OR WALL MRD. JUNCTION BOX Cd) MTD. AT 80" MEASURED FROM FINISHED FLOOR TO BOTTOM OF DEVICE. FIRE ALARM SYSTEM STROBE LIGHT (75 Cd) MTD. AT PB PULL BOX, SIZE AS PER NEC Fil 80" MEASURED FROM FINISHED FLOOR TO BOTTOM OF DEVICE. SURFACE WALL MTD. PANELBOARD F❑ FIRE ALARM SYSTEM MANUAL PULL STATION, MTD. AT 4' -0" A.F.F. FLUSH MTD. PANELBOARD FAC.P. FIRE ALARM SYSTEM CONTROL PANEL 3-3-❑, SAFETY DISCONNECT SWITCH, 30= SWITCH SIZE, 3 =No. OF POLES, 15 =FUSE SIZE, O =NON FUSED. F.A.A.P. FIRE ALARM SYSTEM ANNUNCIATOR PANEL C.R. CARD READER MOTOR RATED SWITCH D.C. DOOR CHIME $ 20A. 120/277VAC SINGLE POLE TOGGLE SWITCH, D.B. DOOR BELL SPECIFICATION GRADE 4' -0" A.F.F. ° $3 THREE WAY SWITCH, SAME AS ABOVE CEILING / WALL MOUNTED VIDEO CAMERA (EMPTY CONDUff SYSTEM, EQUIPMENT BY OWNDER. 3 ,a 20A. 125V. 3 WIRE GROUNDING TYPE ISOLATED GROUND DUPLEX RECEPTACLE, MTD. 18" A.F.F., U.I.O. TV�I CABLE TV CONNECTION 3�) 20A. 125V, 3 WIRE GROUNDING TYPE SPECIFICATION GRADE DUPLEX RECEPTACLE, MTD. 18" A.F.F., U.I.O. GENERATOR SHALL BE IN INSTALLED AS A NON- SEPARATELY DERIVED GROUNDING SYSTEM. EXTERIOR IT ROOM 3 /600 TAP PHASE A&C AT MANUAL TRANSFER MAIN LUGS. PER SWITCH N.E.C. 240.21 600 PANEL 3600 PANEL 'A" "MDP" 300A M.L.O. M.C.B. 3R N3R 22K AIC SEC, I SEC. 2 N.T.S. PROVIDE 1- 5/8'x10' GND ROD FOR FUTURE GENERATOR BONDING CONNECTION. 3 - #300 kcmil & 1 - #2 SS GND THWN CU WIRE IN 2 -1/2" C PROVIDE SPECIAL RECEPTACLE, 3 pHs. 600A RATED TO CONNECT FUTURE PORTABLE GENERATOR. (1) (1) (1) (1) (1) GENERAL NOTES: 120/24OV, 30, 4W DISTRIBUTION PANEL: "MDP" MOUNTING: SURFACE RATING: 600 AMPS TYPE: SQUARE D (NQ) MAINS: M.L.O. AIC: 22,000 �c DESCRIPTION °a o 3 o c> DESC PTION o � � 0 o 1 SPACE 1 — — — 2 SPACE — — — — — 3 SPACE 1050 — — — 4 SPACE LIGHTING (CONF. RM, CORR) — — — — — 5 SPACE 5 — — — 6 SPACE 49 — — — — — 7 600 X6 0 5880 #6 1' 8 MINI -SPLIT SY '2" (IT RM) 20 1404 #12 1/2" 9,^,, RTU 1 5880 8 LIGHTING (TELLER AREA) 1200 #10 1 1404 53 SPARE 9 LIGHTING VAULT VESTIBULE 11 — 5880 CITY NATIONAL BANK SIGN 1200 12 MINI -SPLIT SYSTEM "1" (ATM RM) 0 1404 400 HVAC CONTROLS 1 200 13 11 /60' 5880 750 1200 #10 14 1404 COVE LIGHTING STRIP (WAITING) 800 15 RTU -2 5880 1 13 RECEPTACLES MANAGER 16 SPACE #10 — — — — 17 5880 720 18 SPACE LIGHTING FOYER ATM AREA — — — — 19 SPACE — — — — 20 SPACE — — — — 20 — 21 SPACE — — — — 22 SPACE — — — — 23 SPACE LIGHTING (DRIVE THRU AREA) — — — 24 SPACE — — — — — 25 SPACE 920 — — — 26 SPACE RECEPTACLES (OFFICE) — — — — — 27 SPACE 23 — — — 28 SPACE — — — — — 29 SPACE — — — — 30 SPACE 750 — — — 26 — TOTAL CONNECTED LOAD: 103.5 KVA (431.3 AMPS WORST CASE) c' rM GENERAL NOTES: 120/24OV, 10, 3W DISTRIBUTION PANEL: "A" (SECTION 1 MOUNTING: SURFACE RATING:400 AMPs TYPE: SQUARE D (NQ) MAINS: 300A MCB W/ FEED THRU LUGS AIC: 22,000 c0i DESCRIPTION °a 0 3 cz0� c> DESCRIPTION o � � 0 3 U 1 LIGHTING OFFICE 1 1050 112 1/2" 2 LIGHTING RESTROOMS, CORR) 800 #12 1/2" 3 LIGHTING OFFICE %50 3750 1050 1" 46 TANKLESS WATER HEATER #2 0 4 LIGHTING (CONF. RM, CORR) 800 3750 5 BLINDS OFFICE 2100 1000 49 COPIER 6 LIGHTING LOUNGE, CLOSET) 1/2" 50 600 1 0 720 #12 7 LIGHTING IT RM, VAULT) SPARE 360 — — 52 CITY NATIONAL BANK SIGN 8 LIGHTING (TELLER AREA) 1200 #10 800 — 53 SPARE 9 LIGHTING VAULT VESTIBULE — — 360 CITY NATIONAL BANK SIGN 1200 10 LIGHTING WORK ROOM) — 400 HVAC CONTROLS 1 200 #12 11 LIGHTING TELLER AREA CITY NATIONAL BANK SIGN 750 1200 #10 12 COVE LIGHTING STRIP (WAITING) 800 1 1 13 RECEPTACLES MANAGER 540 #10 59 14 LIGHTING (LOBBY) 1000 720 60 15 LIGHTING FOYER ATM AREA 1200 850 61 CUSTOMER UNff 11 16 SPARE 1000 — — — — 17 PARKING LIGHTING 20 920 #8 3/4" 18 INIGHT LIGHTING (LOBBY) 63 1250 #12 1/2" 19 920 64 LIGHTING (DRIVE THRU AREA) 20 RECEPTACLES (OFFICE) 450 #10 1080 65 DRIVE -THRU SIGN 21 PARKING LIGHTING 920 66 SPARE 22 RECEPTACLES (OFFICE) — — 720 67 AUDIO SWITCHER #1 23 920 68 MINI SPLITS CONDENSATE PUMPS 24 RECEPTACLES (RESTROOMS) #12 1/2" 900 AUDIO SWITCHER #2 800 25 ELECTRIC WATER COOLER 750 112 LIGHTING (EXTERIOR) 1/2" 26 RECEPTACLES (R ROOM) 1/2" 71 360 — — — 27 RECEPTACLES (EXTERIOR) — 360 — — — 73 28 RECEPTACLES (IT ROOM) — — 360 74 SPACE — — 29 RECEPTACLES (LOUNGE, CLOSET) — 75 900 — — — 30 RECEPTACLES (R ROOM) — 360 — — — 77 31 REFRIGERATOR (LOUNGE) — — 800 78 SPACE — 32 RECEPTACLES (WAITING AREA) — — 1080 SPACE — — 33 RECEPTACLES SPACE 360 — — — — 34 RECEPTACLES TELLERS AREA — 720 — 82 SPACE 35 RECEPTACLES (CONF. RM) — — 900 83 SPACE — 36 RECEPTACLES (TELLERS AREA) 84 SPACE 720 — — — — 37 RECEPTACLES WORK RM) 360 38 RECEPTACLES TELLERS AREA) 720 39 RECEPTACLES (WORK RM) 180 40 RECEPTACLES (WORK RM) 540 411 RECEPTACLES (WORK RM) 360 42 RECEPTACLES WORK RM) 900 (1) CONNECT THRU 12 POLE LIGHTING CONTACTOR AND TIME CLOCK. PROVIDE 7 DAY TIME SWITCH W/ SEASONAL ADJUSTMENT AND 4 HOUR BATTERY BACK -UP. INTERMATIC #ET 102C. (2) PROVIDE LOCK -ON BREAKER. 1 GENERAL NOTES: 120/24OV, 10, 3w DISTRIBUTION PANEL: "A" (SECTION ) MOUNTING: - SURFACE RATING: 400 AMPs TYPE: SQUARE_ D (NQ) MAINS: M.L.O. W/ FEED THRU LUGS AIC: 22,000 DES 0 0 CL 0 3 o v DESCRIPTION <n cv 3 z v 43 FIRE ALARM CONT PNL IT ROOM 1 800 #12 1/2" 44 RECEPTACLES (CONF. RM) 540 #12 1/2" 45 TANKLESS WATER HEATER #1 %50 3750 #6 1" 46 TANKLESS WATER HEATER #2 0 2100 #10 47 3750 48 2100 49 COPIER 3715050 #12 1/2" 50 RECEPTACLES (ROOF) 1 0 720 #12 51 SPARE — — — 52 CITY NATIONAL BANK SIGN 1200 #10 — 53 SPARE — — — 54 CITY NATIONAL BANK SIGN 1200 #10 — 55 HVAC CONTROLS 1 200 #12 1/2" 56 CITY NATIONAL BANK SIGN 1200 #10 57 OPERATOR UNIT #1 1000 1 1 58 CITY NATIONAL BANK SIGN 1200 #10 59 OPERATOR UNIT #2 1000 60 MONUMENT SIGN (SITE) 1200 #10 61 CUSTOMER UNff 11 1000 62 FUTURE BACK -LIT SIGN 1200 #10 63 CUSTOMER UNIT #2 1000 64 LIGHTING (DRIVE THRU AREA) 450 #10 65 DRIVE -THRU SIGN 1250 66 SPARE — — — 67 AUDIO SWITCHER #1 800 68 MINI SPLITS CONDENSATE PUMPS 200 #12 1/2" 69 AUDIO SWITCHER #2 800 70 LIGHTING (EXTERIOR) 200 #12 1/2" 71 SPACE — — — 72 SPACE — — — — — 73 SPACE — — — 74 SPACE — — — — — 75 SPACE — — — 76 SPACE — — — — — 77 SPACE — — — 78 SPACE — — — — — 79 SPACE — — — 80 SPACE — — — — — 81 SPACE — — — 82 SPACE — — — — — 83 SPACE — — — 84 SPACE — — — — — PANEL "A' LOAD CALCULATIONS: (1) CONNECT THRU 12 POLE LIGHTING CONTACTOR AND TIME CLOCK. LIGHTING 0125% =30.5 KVA PROVIDE 7 DAY TIME SWITCH W/ SEASONAL ADJUSTMENT AND 4 RECEPTACLES -FIRST 10 KVA 0100% =10.0 KVA HOUR BATTERY BACK -UP. INTERMATIC #ET 102C. REMAINING 3.14 KVA0507o = 1.6 KVA MISCELLANEOUS =20.5 KVA =62.6 KVA LLI - U U-- a', m d-) %4 v 0; 'I, �t �t U ff LLU %5 Z z lL I �a) �U(m Q � O �vz LLI LLI } W • W ccv m �- I— V) Ei CA Q3 N O '. d Z u- LLI L�L.I -1-1 Lu � Z4 OW '2) '1) '1) '1) '1) '1) '1) ;1) '1) '1) ff 0 M W � C, Q C L 0 (300• 0 V � Zm Luv • C 0 C C �C o � d- �0� M M Cc � LL ca 5 � _< CU ♦♦O = v, I� ■� ()o V MO U) .......... u") ° o J oar° �A OVZ (II >wa z iA o C C) � N� N N �o i ' I v o 4) Itr. -4- 0') N U 0 z 0 0 C <n cv �+ Q N 00 v p ° C 0 co I. in Q. 0 '3 'a E1.0 Q N Ir .?J to 0 cl • r 0 c* Q 0 0 J V. n W Y a J a • 0 r W C7 D Q O oC Z OC a m 3 W 2 O O N N To