11-626R-023I PLUMBING GENERAL NOTES I A. UNLESS OTHERWISE SPECIFIED ON THIS DRAWING CONTRACTOR SHALL REFER TO ORIGINAL LANDLORD SPECIFICATIONS FOR ALL APPUCABLE REQUIREMENTS, NOTES, DETAILS, CONSTRUCTION'S STANDARDS, ETC., COORDINATE WITH LANDLORD REQUIREMENTS PRIOR TO ORDERING AND /OR INSTALLATION OF ANY EQUIPMENT AND ACCESSORIES SHOWN. iTwi11 ►14_41I-t4,. EXAMINATION OF CONTRACT DOCUMENTS AND SITE OF WORK; THE BIDDER IS REQUIRED, BEFORE SUBMITTING HIS PROPOSAL, TO VISIT THE SITE OF THE PROPOSED WORK AND FAMILIARIZE HIMSELF /HERSELF WITH THE NATURE AND EXTEND OF THE WORK AND ANY LOCAL CONDITIONS THAT MAY IN ANY MANNER AFFECT THE WORK TO BE DONE AND EQUIPMENT, MATERIALS AND LABOR REQUIRED THEREFORE. SINCE THE WORK INVOLVES EXISTING BUILDINGS, SYSTEM AND FACILITIES, SPECIAL CONSIDERATION SHALL BE GM31 TO EXAMINATION OF WORKING CONDITIONS, EXISTING FACIUTIES AND ALL BUILDING STRUCTURES TO FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. VARIATIONS IN ROUTING AND /OR CONSTRUCTION SHOULD BE ANTICIPATED BY THIS CONTRACTOR AND ARE EXPRESSLY INCLUDED AS PART OF THE WORK WHENEVER REQUIRED AT NO ADDITIONAL COST TO THE OWNER. IGNORANCE ON THE PART OF THE CONTRACTOR WILL IN NO WAY REUEVE HIM OF THE OBUGATION AND RESPONSIBIUTIES ASSUMED UNDER THIS CONTRACT. 2. THE NATURE OF THE REMODEL TYPE CONSTRUCTION POSES SPECIAL PROBLEMS FOR THE DESIGN ENGINEERS AS WELL AS THE PLUMBING CONTRACTOR. EVERY EFFORT HAS BEEN MADE BY THE ENGINEERS TO SHOW AND IDENTIFY THE LOCATIONS AND TYPES OF EXISTING PLUMBING SYSTEMS. THE MAJOR PORTION OF THE PLUMBING SYSTEMS ARE AS SHOWN ON THE DRAWINGS HOWEVER DEVIATIONS MAY BECOME EVIDENT AS THE JOB PROGRESSES. PLUMBING CONTRACTOR SHALL PERFORM A FIELD VERIFICATION BEFORE BIDDING THIS PROJECT. 3. CONTRACTOR WILL BE RESPONSIBLE FOR COODINATING HIS DEMOLITION WORK WITH OTHER TRADES, AND TO PROTECT FROM DAMAGE EXISTING SYSTEMS TO REMAIN. 4. CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF EXISTING PIPES BEFORE COMMENCING TO WORK AND MAKE MODIFICATIONS AS REQUIRED WITHOUT ADDITIONAL COST TO THE OWNER. 5. ALL PIPING SHALL BE INSTALLED RECESSED IN BLOCK WALLS, CHASES OR PARTITIONS. 6. EXISTING PIPES SERVING AREAS NOT COVERED BY THIS CONTRACT BUT IN SERVICE AT THIS TIME SHALL NOT BE INTERRUPTED EXCEPT AS A TEMPORARY INTERRUPTION COORDINATED WITH THE OWNER AND LANDLORD. 7. PLUMBING CONTRACTOR SAW. PAY ALL FEES, INSPECTION AND CONNECTION CHARGES REQUIRED. 8. PLUMBING CONTRACTOR SHALL VERIFY ALL SPACE CONDITIONS AND DIMENSIONS AT JOB SITE PRIOR TO FABRICATION AND INSTALLATION OF MATERIALS AND EQUIPMENT. 9. COORDINATE ALL WORK WITH OTHER TRADES. 10. PLUMBING CONTRACTOR SHALL GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE. 11. PROVIDE SHOCK ABSORBERS SIZE, QUANTITY AND LOCATION AS PER P.D.I. STANDARDS. 12. PROVIDE SHUT -OFF VALVE FOR EACH GROUP OF FIXTURE AND EACH FIXTURE SUPPLY. 13. WHEREVER DISSIMILAR METALS ARE TO BE JOINED, A DIELECTRIC FITTING SHALL BE PROVIDED TO CONNECT BOTH TYPES OF PIPES. 14. CONTRACTOR SHAT BE RESPONSIBLE TO COORDINATE ALL ROUGH -INS WITH THE MANUFACTURER BEFORE MAKING ANY INSTALLATION. 15. POTABLE HOT AND COLD WATER SYSTEMS SHAT BE 'LEAD FREE" WITH LEAD CONTENT NOT EXCEEDING 0.2 PERCENT FOR SOLDER AND FLUXES AND 8 PERCENT FOR PIPE FITTINGS, FIXTURES AND TRIM. CONTRACTOR SHALL VERIFY MANUFACTURER'S COMPLIANCE. 16. ALL POTABLE HOT AND COLD WATER SYSTEMS SHAT BE FLUSHED CLEAR, STERIUZED WITH AN APPROVED SOLUTION AND THROUGHLY FLUSHED OF ALL RESIDUAL SOLUTION AFTER FINAL PRESSURE TESTS AND WITH ALL TRIM AND CONNECTIONS INSTALLED. 17. PROVIDE SHUT -OFF AND VACUUM BREAKER TO ALL HOSE BIBBS AND FAUCETS WITH HOSE -END CONNECTIONS. 18. ALL FLOOR DRAINS SHAT HAVE TRAP PRIMERS TO PROTECT THE SEAL OF THE TRAP. 19. PVC PIPING IS NOT ALLOWED IN RETURN AIR PLENUMS. IF RETURN AIR PLENUMS ARE USED, CONTRACTOR SHAW. REPLACE ALL EXISTING PVC PIPING WITH CAST IRON OR COPPER PIPING. 20. DRAINAGE SYSTEM DESIGN IS BASED ON 1/8' PER FOOT MINIMUM FALL FOR PIPES 3' OR LARGER AND 1/4' PER FOOT MINIMUM FALL FOR PIPES 2' OR SMALLER, ANY DEVIATIONS SHALL BE APPROVED BY ARCHITECT /ENGINEER. 21. ALL VENT THROUGH ROOF OPENINGS SHALL BE OFFSETED TO A MINIMUM DISTANCE OF 3' -0' FROM PARRAPET WALL OR ROOF EDGE SEE ARCHITECTURAL DRAWINGS FOR ROOF FLASHING. LEAD FLASHING WILL NOT BE ACCEPTED. 22. DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED WITH PRE - MANUFACTURED SLEEVE IN ACCORDANCE WITH FLORIDA PLUMBING CODE 404.6.4. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES. PLUMBING SPECIFICATION 1. GENERAL - MATERIAL SHALL BE NEW, UNUSED, BEST OF THEIR RESPECTIVE KINDS AND FREE FROM DEFECTS IN WORKMANSHIP; IN CONFORMANCE WITH THE LATEST PUBUCATIONS IN FORCE AT TIME OF BIDDING. 2. PIPE AND FITTINGS: A DRAINAGE WASTE AND VENT PIPING INCLUDING: PVC DRAINAGE WASTE AND PIPING (DWV) CONFORMING TO ASTM D -2665. INSTALL PLASTIC (PVC) PIPES ONLY WHEN ITS APPROVED BY LOCAL AUTHORITIES AND NOT TO BE USED IN AIR RETURN PLENUM. B. DOMESTIC WATER SUPPLY PIPING: COPPER PIPE TYPE 'L' WITH BRONZE OR WROUGHT COPPER SOLDER JOINT FITTINGS, ASTM.B88 -78. C. CONDENSATE PIPING: AS HERON BEFORE SPECIFIED FOR SANITARY SOIL, WASTE AND VENT PIPING. D. COMPRESSED AIR PIPING: SEAMLESS TYPE L COPPER TUBING WITH SWEAT WROUGHT COPPER FITTINGS. E. VACUUM PIPING: SCHEDULE 40 PVC PIPE. 3. JOINTS AND METHODS OF CONNECTION: A DWV COPPER PIPE: JOINT WITH 95 -5 TIN - ANTIMONY SOLDER, INSTALL PER MANUFACTURER'S RECOMMENDATIONS. B. TYPE 'L' COPPER TUBE: JOIN WITH 95 -5 TIN - ANTIMONY SOLDER, INSTALL PER MANUFACTURER'S RECOMMENDATIONS. C. STEEL PIPE: a. THREADED JOINTS: AFTER CUTTING AND BEFORE THREADING, REAM ALL PIPE AND REMOVE BURRS. MAKE JOINTS WITH JOINT COMPOUND APPUED TO MALE THREADS ONLY. b. FLANGED JOINTS: STANDARD WEIGHT, 150 P.S.I. STEEL, WITH APPROVED RED RUBBER GASKET OR NEOPRENE RUBBER GASKET, INSTALL AS PER MANUFACTURER'S RECOMMENDATIONS. 4. UNIONS AND FLANGES: A. COPPER PIPE: BRONZE UNIONS FOR 2 INCHES AND SMALLER. FOR 2 -1/2 INCHES AND LARGER USE BRONZE FLANGED CONNECTIONS 150 POUND CLASS. B. DIELECTRIC UNIONS OR FLANGES: UNIONS SHALL MEET DIMENSIONAL REQUIREMENTS AND TENSILE STRENGTH OF PIPE UNIONS IN ACCORDANCE WITH FED. SPEC. WW -U -531 E. UNIONS OR FLANGES SHALL BE SUITABLE FOR REQUIRED OPERATING PRESSURES AND TEMPERATURE CONDITIONS. UNIONS SHALL HAVE METAL CONNECTIONS ON BOTH ENDS. ENDS SHALL BE THREADED OR SOLDERED TO MATCH ADJACENT PIPING. METAL PARTS OF UNION OR FLANGED SHALL BE SEPAREATED TO PREVENT CURRENT FLOW BETWEEN DISSIMILAR METALS. EPCO DIELECTRIC PIPE FITTINGS OR EQUIVALENT. 5. ESCUTCHEONS: CHROME PLATED OR STAINLESS STEEL WITH SET SCREWS FOR HOLDING SECURELY IN PLACE. USE ESCUTCHEONS ON PIPES PASSING THROUGH WALLS, FLOORS AND COUNGS OF FINISHED AREAS. 6. PIPE INSULATION: A. ALL CONDENSATE LINES SHALL BE INSULATED WITH 3/4" FIRE RETARDANT ARMAFLEX INSULATION WITH A MAXIMUM OF 25/50 FLAME SPREAD AND SMOKE DEVELOPED RESPECTIVELY. B. ALL HOT WATER AND TEMPERED WATER UNES SHALL BE INSULATED WITH 1' FIRE RETARDANT ARMAFL.EX INSULATION WITH A MAXIMUM OF 25/50 FLAME SPREAD AND SMOKE DEVELOPED RESPECTIVELY. 7. INSTANT -FLOW WATER HEATERS SHALL BE OF THE CAPACITY AND ELECTRICAL CHARACTERISTICS INDICATED ON PLANS AS MANUFACTURED BY CHRONOMITE LABORATORIES,INC. 8. TRAP PRIMER SHALL BE SELF PRIMING TYPE ON COLD WATER SUPPLY LINE AS MANUFACTURED BY PRECISION PLUMBING PRODUCTS, INC. "PRIME -RITE" #PR -500. WHEN TWO OR MORE TRAPS REQUIRE PRIMING, PROVIDE WITH DISTRIBUTION UNIT #DU -2, 3 OR 4 AND SUPPLY TUBE #SS -8 ASSEMBLY. PROVIDE ACCESS PANEL AND INSTALL AS PER MANUFACTURER'S RECOMMENDATION. 9. FLOOR DRAINS: AS MANUFACTURED BY JOSAM. A. FD -1: JOSAM 30000 -A SERIES WITH 6 "x6" SQUARE NIKALOY TOP AND 1/2" TRAP PRIMER CONNECTION. 10. ALL WORK SHALL BE DONE IN ACCORDANCE WITH FMC 2007 PLUMBING LEGEND SYMBOL DESCRIPTION DRAIN COLD WATER UNE (CW) --- FW - - -- FILTERED COLD WATER UNE (CW) ------ --- --- ----- HOT WATER RECIRC. (HWR) WATER CLOSET HC FLOOR TANK TYPE (HANDICAP) 81 8 P - -CD- CONDENSATE DRAIN UNE ---------- -- -- -- HOT WATER UNE (HW) P -2A SANITARY WASTE UNE (SAN) 1 1/4' ----- - - - - -- SANITARY VENT UNE (V) V VACUUM UNE A COMPRESSED AIR UNE 1/2' AIR CHAMBER SELECTION BY ARCH. /OWNER CHECK VALVE -® FCO FLOOR CLEAN OUT �1 CO WALL CLEAN OUT GATE VALVE - - --- HB HOSE BIBB VALVE IN BOX ---- R -- - --- Al VN GATE VALVE IN VERTICAL °C "P" Tom' UNION --- -�- ABV. ABOVE BLW BELOW CEIL, CLG. CEILING FL FLOOR F.U. FIXTURE UNIT (UG) UNDERGROUND V.T.R. VENT THRU ROOF VB VACUUM BREAKER TP TRAP PRIMER CONNECTION (NEW TO EXISTING) MAX PENETRATION INTO POST - TENSION SLAB 1 -1/2 IF GREATER PENERATION REQUIRED SLAB MUST BE X -RAYED AT CONTRACTOR'S COST PIPE W/ INSULATION NUT CLEVIS HAN PIPE 0.[ INSULATION - PIPE INSULATIO - SADDLE GALV. SHIELD PLUMBING FIXTURE CONNECTION SCHEDULE NO. DESCRIPTION DRAIN WATER REMARKS COLDI HOT P -1A WATER CLOSET HC FLOOR TANK TYPE (HANDICAP) 81 8 P 3' 1/2' -- SELECTION BY ARCH. /OWNER P -2A LAVATORY (WALL HUNG) HC (1.0 GPM FAUCET) 1 1/4' 1/2' -- SELECTION BY ARCH. /OWNER P -3 DRINKING FOUNTAIN 1 1/4' 1/2' -- SELECTION BY ARCH. /OWNER NOTES: 1. ALL FIXTURES SHALL COMPLY WITH THE FLORIDA BUILDING CODE WATER CONSERVATION STANDARDS. 2. ALL LAVATORIES AND SINKS SHALL BE PROVIDED WITH C.P. BRASS SUPPUES WITH WHEEL HANDLES, 17 GA. CP BRASS TRAPS WITH C.O. PLUG AND WITH ONE PIECE CHROME PLATED ESCUTCHEONS. 3. ALL PLUMBING FIXTURES SHALL BE CAULKED AND INSTALLED AS PER UPC AND MANUFACTURER'S RECOMMENDATIONS. 4. ALL PLUMBING FIXTURES' FAUCETS AND TRIM TO BE INSTALLED BY PLUMBING CONTRACTOR. PIPE W /OUT INSULATION TEST TEE THREADEE CLEANOUI PIPE HANGERS- CLEVIS TYPE DETAIL N.T.S. WALL CLEANOUT (NOT TO SCALE) ACCESS COVER AND FRAME FINISHED WALL SURFACE s° % ADD ° � ��i •.,.� 7, JMM Consulting Engineers LLC Certificate OF Authorization 19692 Jose M. Martinez, P.E. #56018 8353 SW 124 St. Suite 108 TEL (305) 255 -1621 Miami, Florida 33156 FAX (786) 467 -0815 TO THE BEST OF MY KNOWLEDGE, THE PLANS AND SPECIFICATIONS SUBMITTED HEREWITH COMPLY WITH EXISTING INTERPRETATIONS AND PROVISIONS OF THE APPLICABLE BUILDING CODES. THIS DRAWING IS THE SOLE PROPERTY OF 'JMM CONSULTING ENGINEERS LLC' AND IS AN INSTRUMENT OF SERVICE NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF JMM CONSULTING ENGINEERS, LLC. PROJECT No:11009 Office Remodeling 6361 Sunset Drive South Miami, FI 33143 - OWNER OGV Sunset Holdings LLC 8400 NW 66 St. Doral A 33166 FIASTW166TION DATE ®OWNER'S REVISION 06/29/12 ��swA ..antq� • t1,s K Pablo Corazzini AR - 91716 K� Luigi Vitalini I AR - 13513 '^ vitalinicorazzini � 0 A R C H I T E C T S 300 Aragon Avenue, Suite 330 1 Coral Gables, FL 33134 . tel: 305.567.0602 1 fax: 305.446.3197 1 www.vcmiami.com FL Registration AA26001 N4 SHEET NO. P -2 fi'