11-626R-021GENERAL ELECTRICAL NOTES 1. ALL WORK SHALL BE IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE, FLORIDA BUILDING CODE AND OTHER APPLICABLE CODES AND STANDARDS. 2. a) THE DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW ALL OFFSETS, BENDS AND BOXES REQUIRED TO MAKE A COMPLETE NEAT INSTALLATION IN ACCORDANCE WITH N.E.C. b) WHEN CONFLICTS ARISE IN LOCATIONS WIRING DEVICES, ELECTRICAL EQUIPMENT, DISCONNECTS, PANELBOARDS, ETC. DUE TO FIELD CONDITION OR IMPROPER FIELD COORDINATION CONTRACTOR SHALL BRING IT TO THE A/E'S ATTENTION AND AT NO EXTRA COST RELOCATE, AND OR EXTEND WITHIN A REASONABLE DISTANCE SUCH ITEM WHICH IS IN CONFLICT. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING LOCATION OF ALL COMPONENTS PRIOR TO ROUGH IN WITH ALL TRADES NO EXTRAS WILL BE ALLOWED FOR FAILURE TO DO SO. 3. THE CONTRACTOR IS RESPONSIBLE FOR EVALUATING FIELD CONDITIONS BY VISITING THE SITE PRIOR TO COMMENCING / BIDDING WORK. 4. THE CONTRACTOR SHALL SATISFACTORILY REPAIR / REPLACE EQUIPMENT OR PART OF STRUCTURE DAMAGED AS A RESULT OF HIS WORK. SURFACES AND FINISHED AREAS SHALL BE RESTORED TO MATCH ADJACENT AREAS. 5. ALL DEVICE BOXES SHALL BE INSTALLED FLUSH AND CONDUITS RUN CONCEALED IN FINISHED AREAS EXCEPT AS SPECIFICALLY SHOWN /NOTED OTHERWISE. 6. ALL ELECTRICAL EQUIPMENT SHALL BE REMOVED FROM STRUCTURE TO BE REMOVED. ACCESSIBLE RACEWAYS, WIRES, BOXES, SWITCHES AND OTHER ELECTRICAL ITEMS ASSOCIATED WITH THIS WORK SHALL BE REMOVED IF NOT REQUIRED FOR NEW EQUIPMENT TO CONTINUE IN SERVICE. 7. WIRE SHALL BE REMOVED BACK TO SOURCE FROM INACCESSIBLE RACEWAYS NOT REUSED. INSTALL BLANK PLATES ON FLUSH OUTLETS NOT REUSED. OLATE COLOR SHALL MATCH ADJACENT SURFACE AS NEAR AS POSSIBLE IN FINISHED AREAS. 8. a) MODIFY AND REROUTE EXISTING WIRING AS REQUIRED TO ACCOMPLISH INDICATED WORK AND CONTINUE SERVICE TO LOADS BEYOND AREA IN WHICH WORK IS DONE. b) CONTRACTOR SHALL RE -USE EXISTING SPARE BRANCH CIRCUIT BREAKER AND/OR EXISTING BRANCH CIRCUITS PRESENTLY SERVING ELECTRICAL DEVICES BEING REMOVED IN AREAS BEING REMODELED. ACTUAL CIRCUIT NUMBERS MAY VARY FROM ACTUAL FIELD CONDITIONS BUT ARE SHOWN TO FACILITATE CIRCUITING LAYOUT. 9. INSTALL POWER AND CONTROL WIRING AND REQUIRED CONTROL COMPONENTS FOR AIR CONDITIONING SYSTEM AS SHOWN NOTED ON THESE DRAWINGS AND PER OTHER APPLICBLE DRAWINGS / INSTRUCTIONS. SEE AIR CONDITIONING DRAWING. 10. ALL MATERIAL REMOVED SHALL BE SISPOSED OF AS DIRECTED BY OWNER. 11. ALL WIRING INDICATED AS EXISTING IS BASED ON ORIGINAL CONTRACT DRAWINGS AND IS TO BE VERIFIED BY CONTRACTOR AT JOB SITE. 12. WIRE SIZE SHALL BE # 12 THHN / THWN UNLESS OTHERWISE NOTED ON PLANS. 13• ALL CONDUCTORS SHALL BE COPPER RUN IN METALLIC CONDUIT. 14. ALL CONDUCTORS SHALL BE RUN IN CONDUIT METALLIC TYPE). IF PVC SCHEDULE 40 IS USED FOR UNDERGROUND FEEDERS ONLY, AN QUIPMENT GROUND CONDUCTOR SIZED IN ACCORDANCE WITH N.E.C. 250 -122 MUST BE INSTALLED AND CONDUIT SIZE INCREASED AS REQUIRED. 15. ALL MATERIALS SHALL BE U.L APPROVED. 16. NEW TYPEWRITTEN PANEL TALLY SHALL BE FURNISHED AFTER JOB IS COMPLETED. 17. ALL BRANCH CIRCUITS SHALL BE PROPERLY PHASE BALANCED. 18. ALL NON POWER RELATED WIRING I N CEILING AIR CONDITIONING PLENUM RUNNING WITHOUT CONDUIT SHALL BE TEFLON COATED CLASSIFIED FOR USE IN PLENUMS. 19. ALL EXISTING LUMINARIES TO BE REUSED SHALL BE THOUGHLYCLEANED AND RELAMPED. 20. ALL BRANCH CIRCUITS TO HAVE A GREEN EQUIPMENT GROUNDING CONDUCTOR SIZED AS PER N.E.C. 250.122. 21. ALL DEVICES IN EXISTING WALLS NOT AFFECTED BY NEW CONSTRUCTION SHALL REMAIN ACTIVE. 22 ALL EMPTY CONDUITS TO BE PROVIDED WITH NYLON PULL STRINGS. 23. FUSES SHALL BE DUAL ELEMENT, TIME DELAY TYPE UNLESS OTHERWISE NOTED. 24. A/C EQUIPMENT WIRING, BREAKER AND FUSE SIZES ARE BASED ON A/C EQUIPMENT SPECIFIED ON CONTRACT DRAWING. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING, BREAKER AND FUSES SIZES IN ACCORDANCE WITH A/C EQUIPMENT NAMEPLATE REQUIREMENTS IF DIFFERENT FROM THAT SPECIFIED ON DRAWINGS, AS WELL AS ANY FEEDER CHANGES BEING AFFECTED BY THIS CHANGE CONTRACTOR SHALL MAKE ABOVE MENTIONED CHANGES AT NO EXTRA COST. 25. CONTACTOR SHALL COORDINATE ALL HIS WORK WITH OTHER TRADES IN ORDER TO FURNISH AND INSTALL ALL CONTROL WIRING AND RACEWAYS, ALL POWER CONTROL CIRCUIT WIRING AND RACEWAY AS SHOWN ON THE AIR CONDITIONING DRAWING OR SPECIFICATIONS. IF AIR CONDITIONG DRAWING REFER TO MANUFACTURER ALL REQUIREMENT AND INCLUDE ALL RELATED WORK IN HAS CONTACT. 26. ALL LUMINARIES SHALL BE PROPERLY SUPPORTED IN ACCORDANCE WITH THE CEILING SYSTEM MANUFACTURER RECOMMENDATIONS AND LOCAL CODE REQUIREMENTS. 27. RISERS ARE DIAGRAMMATIC ONLY. THEY DO NOT SHOW EVERY BEND REQUIRED FOR THE INSTALLATION. 28. THIS DRAWING IS A GUIDE FOR THE ELECTRICAL INSTALLTION. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE A FUNCTIONING SYSTEM. 29. ALL CABLES SHALL BE RUN WITH OUT SPLICES EXCEPT IF OTHERWISE INDICATED. 30. ALL PULL AND JUNCTION BOXES SHAL BE ACCESSIBLE AT ALL TIMES. 31. EXACT POINT AND METHODS OF CONNECTION SHALL BE DETERMINED IN FIELD. 32. ALL WORK SHALL BE DONE IN A NEAT AND WORKMANLIKE MANNER. 33. ALL LOADS IN EXISTING PANELBOARDS ARE ESTIMATED. 34. ALL RACEWAY ROUTED, INSULATED CONDUCTORS SYSTEM SHALL BE COLOR CODED AS FOLLOWS: 120/240 V SYSTEM PHASE 'A' BLACK PHASE 'B' RED NEUTRAL WHITE GROUND GREEN TYPE: SQ'D MTG: FLUSH MOUNTED NEW PANEL 'A' I22K A I CI BUS VOLTS: 1225 240V, 10, 3W MAIN: M.L.O CU BUS /GND. BUS LOAD: 42.5KVA/240 = 177.3A LOAD COND. WIRE TRIP POLE DESCRIPTION CKT No. CKT No. DESCRIPTION POLE TRIP WIRE COND. LOAD 900 1/2" 12 20 1 2ND FL LIGHTS 1 2 GND FL. LIGHTS 1 20 12 1/2" 900 700 1/2" 12 20 1 2ND FL. LIGHTS 3 4 900 720 1/2" 12 20 1 GROUND FLOOR RECEPTS 5 6 800 900 7 8 1000 720 9 10 GND FL RECEPTS 900 720 11 12 900 720 13 14 720 720 15 16 720 1000 2ND FLOOR LIGHTS 17 18 EXTERIOR RECEPTS 720 -- -- -- SPARE 19 20 EXISTING 2ND FL RECS 720 -- -- -- 21 22 EXISTING 2ND FL RECS 720 -- -- -- 23 24 EXISTING SPRINKLER PUMP 1 30 10 3/4" 2100 -- -- -- 25 26 SMOKE DUCT DETECTOR 1 20 12 1/2" 200 27 28 SPARE 1 20 -- -- -- -- -- -- 29 30 SPARE 1 20 -- -- -- 11256 1 1/4" 4 7 2 NEW AHU #1 ( * *) 31 32 NEW CU #1 ( * *) 2 60 6 1" 6600 -- -- -- 33 34 -- -- -- 7500 3/4" 6 5 2 EXISTING AHU ( * *) 35 36 EXISTING CU ( * *) 2 40 4 3/4" 4800 -- -- -- 37 38 -- -- -- 7500 3/4" 6 5 2 EXISTING AHU ( * *) 39 40 EXISTING CU ( * *) 2 40 4 3/4" 4800 -- -- -- 41 1 42 -- -- -- COOLING & HEATING LOADS ARE NON- CONCURRENT - PROVIDE HACR TYPE BREAKER. NEW 2P -200A SERVICE RATED (42K AIC) MAIN ENCLOSED BREAKER NEW 1 #4(G) -3/4 "C TO (2) 5/8" DIAX101 LONG COPPER CLAD STEEL GROUND DRIVE RODS SPACED 6Ff APART & C.W.P. � I ' I I I 3 #3/0 -2 "C EXISTING 3 #3/0 -2 "C FPL OVERHEAD SERVICE TO REMAIN. i 1 NEW 3 #3/0 & 1 #6(G) -2 "C 1 I I 1 I I 1 r - -1 - -� r- -iE - -� I 1 I I EXISTING EXTERIOR PANEL 'F 4", ;.� TO BE REMOVED WITH ALL ASSOCIATED WIRING I I I I I I aC I _ EXISTING GROUND EXISTING FPL TO BE REMOVED METER TO MAIN NEW PANEL "A" ELECTRICAL RISER DIAGRAM N.T.S. o. R;fr 91R11DA JMM Consulting Engineers LLC Certificate OF Authorization #9692 Jose M. Martinez, P.E. #56018 8353 SW 124 St. Suite 108 TEL (305) 255 -1621 Miami, Florida 33156 FAX (786) 467 -0815 TO THE BEST OF MY KNOWLEDGE, THE PLANS AND SPECIFICATIONS SUBMITTED HEREWITH COMPLY WITH EXISTING INTERPRETATIONS AND PROVISIONS OF THE APPLICABLE BUILDING CODES. THIS DRAWING IS THE SOLE PROPERTY OF 'JMM CONSULTING ENGINEERS LLC' AND IS AN INSTRUMENT OF SERVICE NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF JMM CONSULTING ENGINEERS, LLC. PROJECT No. 11009 Office Remodeling 6361 Sunset Drive South Miami, F1 33143 OWNER OGV Sunset Holdings LLC 8400 NW 66 St. Doral A 33166 STRIBUTIONT__.� DA'TET ®OWNER'S REVISION 06/29/12 Pablo Corazzini I AR - 91716 Luigi Vitalini I AR - 13513 N, � I **..o vitalinicorazzini A R C H I T E C T S 300 Aragon Avenue, Suite 330 1 Coral Gables, FL 33134 tel: 305.567.0602 1 fax: 305.446.3197 1 www.vcmiami.com FL Registration AA26001654 SHEET NO. E -3