11-626R-011General Notes And Conditions
Architectural General Notes
1.
THE CONTRACT DRAWINGS AND SPECIFICATIONS HAVE
ALUM
ALUMINUM
ARCH
BEEN CAREFULLY CHECKED BY THE ARCHITECT TO
1.
ALL WOOD IN CONTACT W/ CONCRETE SHALL BE PRESSURE
AVE
PROVIDE CONTRACT DOCUMENTS WHICH CLEARLY DEFINE
AHU
TREATED
ACU
THE RESULTS THE CONTRACTOR IS EXPECTED TO ACHIEVE.
2.
ALL WOOD, STANDARD OR PRESSURE TREATED SHALL BE
BOTT
PRIOR TO COMMENCEMENT OF CONTRACTED WORK, THE
BOB
FIRE TREATED.
BOC
CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY
3.
PROVIDE 5/8• BACKING AT ALL WALL CABINETS
BLDG
CONFLICTS, OMISSIONS, OR LACK OF DEFINITION BETWEEN
CAB
CABINET
CLG
THE DRAWINGS AND THE SPECIFICATIONS OR BETWEEN
4.
REFER TO ARCHITECTURAL, INTERIOR DRAWINGS, LOW
COL
THE CONTRACT DOCUMENT AND EXISTING SITE
CONC
VOLTAGE DRAWINGS, AND STANDARD DETAILS FOR WALL
CONT
CONDITIONS IN ORDER TO RESOLVE ANY PROBLEM. THE
CU FT
WOOD BLOCKING REINFORCEMENT REQUIREMENT
CU YD
COMMENCEMENT OF CONTRACTED WORK BY THE
DIM
INFORMATION TO SUPPORT GRAB BARS, BATHROOM
DR
CONTRACTOR WILL BE DEEMED AS ACCEPTANCE OF THE
DN
ACCESSORIES, MILLWORK, CROWN MOLDING, BASE
DWG
CONTRACT DOCUMENTS AS BEING TRUE AND CORRECT
DF
BOARDS, CHAIR RAILS, WAINCOTS, A/V EQUIPMENT, AND
EA
AND NO REQUESTS FOR ADDITIONAL PAYMENT DUE TO
ENV
ART LOCATIONS.
ELEC
CONFLICTS, OMISSIONS, OR LACK OF DEFINITION ALL
5
ALL GYPSUM BOARD CORNERS SHALL RECEIVE METAL
ELEV
REQUESTS FOR INFORMATION BY THE CONTRACTOR SHALL
EMER
CORNER BEADS. ALL EXPOSED GYPSUM BOARD EDGES
EQ
BE MADE PRIOR TO THE TENDERING OF A BID
EQPMT
SHALL HAVE METAL CASING BEADS.
2,
ALL DETAILS, SECTIONS, PLANS, DIAGRAMS AND OTHER
EXIST
EXISTING
EXT
GRAPHIC AND VERBAL INFORMATION SHOWN IN THE
6,
ALL GYPSUM BOARD IN BATHROOMS SHALL BE MOISTURE
F EXT
DRAWINGS ARE INTENDED TO BE TYPICAL U.O.N. AND
FD
RESISTANT ("GREEN BOARD°).
FIG
SHALL BE CONSTRUED TO APPLY TO ANY AND ALL SIMILAR
GA
GAGE
GALV
CONDITIONS ELSEWHERE IN THE PROJECT.
T
ALL TILE FINISH INSIDE SHOWERS, STEAM ROOMS, AND
3.
GLASS - GLAZING
GYP
KITCHEN TO BE INSTALLED ON 1/2' CEMENTITIOUS BACKER
HOW
IT IS NOT THE INTENT OF THESE PLANS AND /OR
HVAC
BOARD SUBSTRATE.
HGT
SPECIFICATIONS TO SHOW EVERY DETAIL OF THE WORK.
HC
HOLLOW CORE
HM
ACCORDINGLY, THE CONTRACTOR SHALL BE EXPECTED TO
8,
MOISTURE RESISTANT GYPSUM BOARD WILL BE LOCATED IN
ID
FURNISH AND INSTALL ALL ITEMS FOR COMPLETE AND
INSUL
ALL BATHROOMS, POWDER ROOMS, AND KITCHEN AREAS.
INT
PROPER OPERATING SYSTEMS, PROVIDE ALL ASSOCIATED
JT
JOINT
j LAV
HARDWARE, ACCESSORIES AND CONTROLS AS REQUIRED
9,
SUPPORT WIRES FOR CEILINGS, SOFFITS, ETC. SHALL NOT
MO
FOR SYSTEMS, FINISHES, EQUIPMENT, ETC., TO FUNCTION
MAX
BE CONNECTED TO ANY MECHANICAL, ELECTRICAL,
MECH
NORMALLY AND AS INTENDED.
M CAB
PLUMBING OR FIRE PROTECTION PIPING, ETC,
4.
IN THE EVENT THE CONTRACTOR REQUIRES CLARIFICATION
NOM
SUBMIT FOUR SETS OF DETAILED SHOP DRAWINGS, CUT
NIC
OR ADDITIONAL DOCUMENTATION ON ANY PARTICULAR
NTS
SHEETS OR SAMPLES FOR APPROVAL, BY THE ARCHITECT,
NO
ASPECT OF THE DRAWINGS, SUCH CLARIFICATION OR
OC
OF THE FOLLOWING:
OPNG
DOCUMENTATION WILL BE ISSUED TO THE CONTRACTOR
OD
OUTSIDE DIAMETER
PVMT
FROM THE ARCHITECT OR ENGINEER UPON REQUEST.
PL
1. ALL CASEWORK AND MILLWORK
PLYWD
PLYWOOD
PT
2. ALL LIGHT FIXTURES
PSF
POUNDS PER SQUARE FOOT
PSI
& ALL PLUMBING FIXTURES AND TRIM
5,
THE CONTRACTOR SHALL VERIFY THE DRAWINGS,
RWL
4. DOORS AND HARDWARE
REFR
INCLUDING BUT NOT LIMITED TO: DIMENSIONS,
RA
5. WINDOWS
ROW
LOCATIONS, SIZES, INVERTS, PIPES, WIRES, CONDUITS,
RD
ROOF DRAIN
RM
STRUCTURAL ELEMENTS AND UTILITIES PRIOR TO
RO
ROUGH OPENING
SHT
COMMENCEMENT OF THE WORK. ADVISE THE ARCHITECT
10.
SIMILAR
SC
IN WRITING OF ANY DISCREPANCIES, CONFLICTS OR ANY
SPEC
ALL WOOD VENEER SHALL BE RIFT CUT OR VERTICAL GRAIN.
SQFT
OTHER ANTICIPATED PROBLEMS PRIOR TO CONTINUING
SST
ARCHITECT WILL PROVIDE CONTRACTOR WITH INITIAL STAIN
STO
THE WORK FOR DIRECTION BY THE ARCHITECT.
ST
SAMPLE, CONTRACTOR SHALL PROVIDE A RANGE OF HUES
STRUCT
STRUCTURAL
SUSP
ON VENEER SAMPLES FOR FINAL SELECTION. VENEER
TEL
TELEPHONE
T.V.
SAMPLES SHALL BE THE ACTUAL MATERIAL INTENDED TO
6,
ALL WORK SHALL BE INSTALLED AND ARRANGED TO OBTAIN
BE INSTALLED.
THE BEST VISUAL EFFECT. ALL COMPONENTS SHALL BE
INSTALLED TRUE, PLUMB, SQUARE AND IN -LINE WITH
RELATED ELEMENTS, OPENINGS AND PLANES.
11.
CONTRACTOR SHALL PROVIDE SAMPLE OF THE STUCCO FINISH FOR
ARCHITECTS APPROVAL PRIOR TO THE COMMENCING STUCCO WORK
7.
THE GENERAL CONTRACTOR HEREBY INDEMNIFIES AND
12,
ALL CEILING HEIGHTS TO BE VERIFIED WITH ARCHITECTURAL AND
AGREES TO DEFEND AND HOLD THE OWNER HARMLESS
ENGINEERING PLANS.
FROM AND AGAINST ANY AND ALL SUITS, CLAIMS, ACTIONS,
LOSS, COST OR EXPENSE (INCLUDING CLAIMS FOR
WORKMEN'S COMPENSATION BASED ON PERSONAL
INJURY OR PROPERTY DAMAGE CAUSED IN THE
PERFORMANCE OF THIS WORK BY THE GENERAL
CONTRACTOR, HIS EMPLOYEES, AGENTS, SERVANTS, OR
SUBCONTRACTORS ENGAGED BY HIM).
8.
THE CONTRACTOR SHALL COMPLY WITH THE LOCAL
BUILDING CODE AND REGULATIONS, LATEST EDITIONS,
ALONG WITH ALL APPROPRIATE MUNICIPAL AND
REGULATORY AGENCIES CODES AND REQUIREMENTS AND
LANDLORD REQUIREMENTS. CONTRACTOR IS RESPONSIBLE
FOR THE PREPARATION DEPARTMENT FORMS,
DOCUMENTS, FEES AND THE SUBSEQUENT FILING THERE
OF, INCLUDING OBTAINING ALL APPROVALS REQUIRED
PERMITS, EQUIPMENT USE PERMITS, CONTROLLED
INSPECTIONS & FINAL SIGN OFFS.
9.
THE CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL
JOB CONDITIONS, DIMENSIONS, AND DETAILS PRIOR TO
SUBMITTING ANY BIDS. THE ARCHITECT SHALL BE NOTIFIED
OF ANY DISCREPANCIES OR OMISSIONS WHICH WOULD
INTERFERE WITH THE SATISFACTORY COMPLETION OF THE
WORK, PRIOR TO THE SUBMISSION OF BIDS.
LARGE 10. DRAWINGS ARE NOT TO BE SCALED; DIMENSIONS GOVERN.
DETAILS
DO NOT SCALE DRAWINGS. DIMENSION AND/OR EXISTING
CONDITIONS GOVERN.
IMMEDIATELY OF DISCREPANCIES.
Abbreviations
AFF
ABOVE FINISHED FLOOR
AC
AIR CONDITIONING
ALUM
ALUMINUM
ARCH
ARCHITECTURAL)
ASPH
ASPHALT
AVE
AVENUE
AHU
AIR HANDLING UNIT
ACU
AIR CONDENSING UNIT
BD
BOARD
BOTT
BOTTOM
BOB
BOTTOM OF BEAM
BOC
BOTTOM OF CEILING
BOS
BOTTOM OF SOFFIT
BLDG
BUILDING
CAB
CABINET
CLG
CEILING
CO
CLEAN OUT
COL
COLUMN
CONC
CONCRETE
CONT
CONTINUOUS
CU FT
CUBIC FOOT (FEET)
CU YD
CUBIC YARD
DIM
DIMENSION
DR
DOOR
DN
DOWN
DWG
DRAWING
DF
DRINKING FOUNTAIN
EA
EACH
ENV
EACH WAY
ELEC
ELECTRIC(AL)
EWC
ELECTRIC WATER COOLER
ELEV
ELEVATION
EMER
EMERGENCY
EQ
EQUAL
EQPMT
EQUIPMENT
EXP JT
EXPANSION JOINT
EXIST
EXISTING
EXT
EXIT
FIN
FINISH(ED)
F EXT
FIRE EXTINGUISHER
FD
FLOOR DRAIN
FIG
FOOTING
GA
GAGE
GALV
GALVANIZED
GC
GENERAL CONTRACT(OR)
GL
GLASS - GLAZING
GYP
GYPSUM
HOW
HARDWARE
HVAC
HEATING/VENTILATING/AIR CONDITIONING
HGT
HEIGHT
HC
HOLLOW CORE
HM
HOLLOW METAL
HORZ
HORIZONTAL
ID
INSIDE DIAMETER
INSUL
INSULATION
INT
INTERIOR
JT
JOINT
j LAV
LAVATORY
LIN FT
LINEAL FOOT (FEET)
MO
MASONRY OPENING
MAX
MAXIMUM
MECH
MECHANICAL
M CAB
MEDICINE CABINET
'. MIN
MINIMUM
NOM
NOMINAL
NIC
NOT IN CONTRACT
NTS
NOT TO SCALE
NO
NUMBER
OC
ON CENTER
OPNG
OPENING
OD
OUTSIDE DIAMETER
PVMT
PAVEMENT
PL
PLASTIC LAMINATE
PLYWD
PLYWOOD
PT
PRESSURE TREATED
PSF
POUNDS PER SQUARE FOOT
PSI
POUND PER SQUARE INCH
RAD
RADIUS
RWL
RAIN WATER LEADER
REFR
REFRIGERATOR
RA
RETURN AIR
ROW
RIGHT OF WAY
RD
ROOF DRAIN
RM
ROOM
RO
ROUGH OPENING
SHT
SHEET
SIM
SIMILAR
SC
SOLID CORE
SPEC
SPECIFICATION
SQFT
SQUARE FEET
SST
STAINLESS STEEL
STO
STORAGE
ST
STREET
STRUCT
STRUCTURAL
SUSP
SUSPENDED
TEL
TELEPHONE
T.V.
TELEVISION
THK
THICKNESS
T.O. FINISHED SLAB
1]
A A BUILDING SECTION INDICATOR
A000 • •• A000
0 • * • • 1 WALL SECTION INDICATOR
Ad00
0
A
ME
THR
EXTINGUISHER, PROVIDE r0
I,%
SQ.FT. • ON •a• PLAN. BOTTOM OF
TOB
FIRE EXTINGUISHER •:
TYPTYPICAL
• s
VERT
WC6L FIRE EXTINGUISHER USED IN
VI C
COMMERCIAL
0
A
ME
THR
THRESHOLD ••
T &G
TONGUE AND GROOVE ...........................................
TOB
TOP OF BEAM
TYPTYPICAL
...................................................... ...............................
VERT
VERTICAL
VI C
VINYL COMPOSITION TILE
WC
WATER CLOSET
WH
WATER HEATER
WWM
WELDED WIRE MESH .................. — . —
WDW
WINDOW
W/
WITH
W/O WITHOUT
WD WOOD
rIr r r,.
.i i •• •i
�► r s
:a
... •
LINE OF OBJECT
ABOVE
•
HIDDEN LINE
CrQ��L�l sTsiffi
CENTER LINE
office Remodeling
6361 Sunset Drive
South Miami, FI 33143
FOWNER
OGV Sunset Holdings LLC
8400 NW 66 St.
Doral F133166
•
06/07/11
PERMIT SET
06/14/11
ERPB REVIEW
r:
Pablo Corazzini I AR - 91716
SHEET NO.
A - 001