11-626-004DYNATECH ENGINEERING CORP. ASBESTOS SAMPLING REPORT 750 W. 84th Street Hialeah FL 33014 Date :05 -25 -2011 Client_ : DORAL IMAGING INSTITUTE, LLC. Project :6361 SUNSET DRIVE MIAMI, FL 33143 Surveyor No. :09132004 By: P.B Sample Type Bulk-Samples Analysis: P.L.M./D.S. Simple Location Description Approximate Condition Analysis Amount No. F NF Potential for Damage 11 Interior. 2" Floor Drywall & Joint Compound Ceiling N/A X G/L NAD West Area 12 Interior. 2" Floor Drywall do Joint Compound Ceiling N/A X G/L NAD North Area '!lack Mastic Only 13 Interior. 1st Floor Black Mastic Over Silver A/C Fiberglass 75 LNFT X C' /I 4.5%CHRY Center Area Ceiling X G/L )slack Mastic Only 14 Interior. 1st Floor Black Mastic Over Silver A/C Fiberglass N/A 4- 5 %CHRY Center Area Ceiling 15 Interior. 1st Floor Black Mastic Over Silver A/C Fiberglass N/A X G/L Black Mastic Only 4 -sv. cxRY Center Area Ceiling 16 Interior. I" Floor White Mastic Over Silver A/C Fiberglass 50 LNFT X G/L NAD Center Area Ceiling 17 Intcrior. Ist Floor White Mastic Over Silver A/C Fiberglass N/A X G/L NAD Center Area Ceiling It Interior. 1st Floor White Mastic Over Silver A/C Fiberglass N/A X G/L NAD SE Area Ceiling 19 Interior. I" Floor Ceramic Floor Tiles With Grout Over Thin 2500 SF X G/L NAD East Area Set Over Cork Over Wood Floor 20 Interior. 1st Floor Ceramic Floor Tiles With Grout Over Thin N/A X G/L NAD SW Area Set Over Cork Over Wood Floor F = Friable Condition Potential For Damage NF = Non Friable G = Good L = Low NAD = No Asbestos Detected D = Damaged M = Medium CHRY = Chrysotile S = Significantly Damaged H High DYNATECH ENGINEERING CORP. Analyzed by: Premnzth IZoodoosingh McCrone Research Institute Microscopical Identification of Asbestos NO. # 09132004