Loading...
10-286-017REI�,NFORCED CONCRETE NOTES GENERAL NOTES a, 1) ALL POURED IN PLACE GROUT FILL CELLS AND TIE BEAMS AND COLUMNS TO BE 3000 P51 AT 28 DAYS MIN. U EXTEN BOTTOM BARS 8' PAST ALL OPENINGS GREATER THAN V -0' ON BOTH SIDES. 2) ALL CONCRETE WORK IN ACCORDANCE w/ 'SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDING' 13� (ACME 301 -99) 2) TIE BEAMS SHALL BE CONTINUOUS REINFORCEMENT, PROVIDED BY LAPPING SPLICES NOT LESS THAN 30'. CONTINUITY SHALL BE PROVIDED AT ALL CORNERS BY BENDING 2 BARS FROM EACH DIRECTION AROUND 3) NO ADMIXTURES PERMITTED w /OUT WRITTEN APPROVAL OF ENGINEER THE CORNER 30' OR BY ADDING 20 5 BENT 30' EACH LEG. 3) CONTINUITY AT COLUMNS SHALL BE PROVIDED BY CONTINUING HORIZONTAL W13ARS T14W COLUMNS OR BY 4) COMPACT INTERIOR FILL TO 9590 OF MODIFIED PROCTOR MAXIMUM DRY DEN5177 AS PER ASTM D - 1557 AT OPTIMUM MOISTURE CONTENT. BENDIi HORIZONTAL REIN. INTO COLUMNS A DISTANCE OF 30'. 5) PRIOR TO CONSTRUCTION PROVIDE TERMITE PROTECTION TREATMENT TO SOIL IN ACCORDANCE w/ 4) HOOK I Top OF VERTICAL BARS IN ALL TERMINATING COLUMNS 2' BELOW TOP OF SLAB AND 3' BELOW TOP 'NATIONAL PEST CONTROL ASSOCIATION' STANDARDS. SUBMIT TERMITE INSPECTION REPORT PRIOR OF THE TIE BEAM. TO CONSTRUCTION ra 6) PROVIDE CLEANOUT OPENING AT THE BOTTOM OF REINFORCED MASONRY CELLS THAT ARE BEING FILLED TO ENSURE THAT THE CELL 15 FILLED. PROVIDE WEEP HOLES AT 1/3 AND 2/3 OF SPAN. REINFORCED FOUNDATION NOTES ZONE 2 - 5434 PSF 1) ALL REIN. STEEL SHALL CONFORM TO A.S.TM. A -615 GRADE 60. REINFORCING STEEL SHALL BE DETAILED AND FABRICATED ACCORDING% TO THE 'MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED ZONE 3 - 85.84 PSF BEAM SCHEDULE CONCRETE STRUCTURES' LAP CONTINOUS REINFORCING A MIN. OF 30' IN BEAMS 36 BAR DIAMETERS IN 1) STRUCTURAL CONCRETE SHALL CONFOR'1 w/ ACI -301 IT SHALL REACH A MINIMUM COMF'RE551VE STRENGTH SLABS. HOOK ALL DISCONTINOUS TOP REINFORCING. PROVIDE AT ALL CORNERS 205 60' LONG BENT. OF 3001 PSI IN 28 DAYS FOR SLABS 4 FOOTING. ��O on 0 � a SHALL CONFORM TO 8) CLEAR COVER FOR REINFORCING SHALL BE: SLABS: 3/4' 20 AGGREGATES SHALL BE CLEAN AND GRADED MAXIMUM SIZES 3/4' CONCRETE ASTM C -33 � 02 ASTM C -94 FOF41ED FACES IN CONACT w/ EARTH _ 2' J U T`OR9ED FACES 3' 3) CONCRETE TESTING IS REQUIRED AS FOLLOWS: I SET OF 5 CYLINDERS FOR EVERY 50 CU. YDS. OF CONCRETE A$ PER ASTM C-94 9) ALL BLOCK MASONRY WALLS SHALL HAVE HORIZONTAL REINFORCEMENT ' DUR -O -WALL LADDER TYPE z SPACED 1(V ON CENTER USE PREFABRICATED CORNERS AND TEES BY 'DUR -O -WALL AT CORNERS AND 4) MAXIMUM PER915515LE SLUMP IS 5 -6' IN STRUCTURAL CONCRETE w/ THE EXCEPTION BEING SAND CEMENT JUNCTIONS OF WALLS MASONRY UNITS SHALL BE 2 CELL HOLLOW UNITS CONFORMING TO A.STM. C -91 GROUT w/ COMPRESSIVE STRENGTH OF 1900 PAI. ON THE NET GROSS - SECTIONAL AREA AND SHALL BE LAIC) IN RUNNING BOND. MORTAR SHALL BE TYPE 'S' w/ f'm = 1500 PSI. 50 REINFORCING STEEL SHALL C4NFOR'1 TO ASTM A -615 GRADE 60, REINFORCING STEEL SHALL BE DETAILED AND FABRICATED ACCORDING TO THE ' MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE 10J THE USE OF A SCALE TO OBTAIN DIMENSIONS NOT SHOWN ON THE PLANS 15 STRICTLY FORBIDDEN. STRUCTURES'. HOOK ALL DISCONTINUOUS TOP REINFORCING. PROVIDE CORNERS w/ 20 5 X 4' -0' BARS. CLEAR THE ENGINEER WILL NOT BE RESPONSIBLE FOR ERRORS RESULTING FROM SUCH ACTIONS. COVER FOR REINFORCING BARS SHALL BE: 0 "a 11) CONTRACTOR TO LOCATE ALL EXISTING UTILITIES PRIOR TO EXCAVATION. FOOTINGS 3' UNFORMED FACES _ 3' SLABS 3!4' FORMED FACES IN 12) USE CONCRETE MASONRY UNITS CONFORMING TO AS.TM. C90: DESIGN F'c =1900 P.S.I. WHERE ANCHOR BOLTS ARE SET IN MASONRY WALL, FILL BLOCK CELLS w/ GROUT FOR BOLTED COURSE ADD ONE GROUTED CELL BEAMS /COLUMNS ._ I I/2' CONTACT w/ EARTH_ 2' ABOVE AND TWO GROUTED CELLS BELOW ANCHOR ELEVATION. 13) GROUT USED IN THE WORK SHALL CONFORM TO ASTM 0416 w/ A SLUMP MI IX OF 8' TO 11', PROVIDE CLEANOUT AND INSPECTION HOLES AT FILLED CELLS AT BOTTOM COURSE. ALL MORTAR SHALL CONFORM w/ ASTM C210. 14) POUR GROUT IN LIFTS NOT TO EXCEED 4'. STRUCTURAL NOTES APPLICABLE CODES: 15) GROUT USED IN THE WORD SHALL OBTAIN A MINIMUM COMPRESSIVE 5TRENGTH OF 3000 PSI IN 28 DAYS. GROUT A: F.B.C. DADE COUNTY 2001 EDITION. SLUMP REQUIRED - ---- 8' TO II' PROVIDE CLEANOUT HOLES AT TOP, MIDDLE. B: A.C1 318 -05 REINFORCED CONCRETE 1(o) A SPECIAL INSPECTION BY A FL. CERTIFIED ENGINEER OR SPECIAL INSPECTOR, WILL BE REQUIRED FOR ALL C: REINFORCED MASONRY BY A.C.I. 530-05 AND ENGINEERED MASONRY CONSTRUCTION, SOIL COMPACTION AND ROOF TRUSSES OVER 35' LONG OR (W-0' HIGH. THE MASONRY DESIGNERS GUIDE BY AC.I., T.M.S., A.S.C.E. Il) ALL SPECIFIED MATERIALS AND CONNECTORS CAN BE SUBSTITUTED w! EQUAL OR BETTER, w/ THE E: WIND ANALYSIS AND DESIGN PER ASC.E.1 -05. APPROVAL OF ENGINEER OF RECORD. REINFORCING STEEL fy = 60000 P.S.I. fs = 24000 P.S.I. Es = 290WOM P.S.I. 18) ALL STRUCTURAL LUMBER TO BE SOUTHERN PINE No. 2 OR BETTER MINIMUM BENDING STRESS, Fb = 1)00 P51. YOUNG'S MODULES, E = 1FiPJ0000 PSI. Em = 1,351001 P,a1 N - Es/Em = 2148 ALL BLOCK 8' AS.T.M. C -90 HOLLOW UNIT MASONRY DESIGN f'm - 1,500 P.S.I. 4 f'c = 1,910 P.S.I. (PER TABLE 2 ACI 530.1) GROUT SHALL COMPLY w/ AATM. 0416, 28 DAYS MIN. COMP. STRENGTH = 3000 PAI. GROUT SLUMP REQUIRED - - - -- 8' t0 11' PROVIDE CLEANOUT HOLES AT TOPMIDDLE DESIGN LOAD CALCULATIONS AND BOTTOM OF FILLED CELL MORTAR SHALL COMPLY w/ A6311. MORTAR SLUMP REQUIRED ----- 5' t0 8' CONTRACTOR TO CON5OLIDATE GROUT LIFTS w/ 3/4' VIBRATOR ROOF DEAD LOAD TOP CHORD 15 P5F BOTT CHORD 10 PSF ROOF LIVE LOAD 31,5E PLYWOOD ROOF DIAPHRAGM 1. ROOF DIAPHRAGM SHALL COMPLY w/ THE DESIGN RECOMMENDATION5 OF 'A.PA DESIGN / CONSTRUCTION GUIDE - DIAPHRAGMS' AND THE LOCAL BUILDING CODE. 2. PLYWOOD ROOF DECKING SHALL BE 19/32' MINIMUM THICKNESS, AND SHALL BE CONTINUOUS OVER TWO OR MORE SPANS, w/ FACE GRAIN PERPENDICULAR TO THE SUPPORTS. 3. CONNECT PLYWOOD DIAPHRAGM TO STRUCTURE w/ 8d RING SHANK NAILS, SPACED AT 6'04. MAX. AT EDGES AND AT 6'oc. ALONG INTERMEDIATE SUPPORTS. 4' O.C. 9 PIAPHRAM BOUNDARY AND 8d RING SHANK NAILS is 4' oc. 6 GABLE ENDS. 4. INSPECTIONS: SHALL COMPLY w/ THE LOCAL BUILDING CODE REQUIREMENTS FOR INSPECTIONS (BY THE MUNICIPALITY, ARCHITECT OR ENGINEER) OF SPECIFIED COMPONENTS OF THE ROOF STRUCTURE REQUIRING INSPECTIONS. SOIL COMPACTION NOTES I. REMOVE ALL VEGETATION, TOPSOIL, AND ORGANIC MATERIAL w/ IN THE BUILDING AREA PLUS FIVE (5) FEET OUTSIDE THE BUILDING FOOTPRINT. THE AREA UNDER FOOTINGS, FOUNDATIONS, AND CONCRETE SLABS ON GRADE SHALL HAVE ALL VEGETATION, STUMPS, ROOTS, AND FOREIGN MATERIALS REMOVED PRIOR TO PLACEMENT OF FILL. 1 COMPACT THE CLEARED AREA TO A MINIMUM COMPACTION OF 95 PERCENT OF THE DRY SOIL DENSITY AS DETERMINED 137 THE MODIFIED PROCTOR TEST -ASTM 0-1551 PRIOR TO PLACEMENT OF ANY ADDITIONAL FILL REQUIRED. 3. FILL AND COMPACT THE CLEARED AREAS IN LIFTS NOT GREATER THAN 12 INCHES OF L005E THICKNESS TO ELEVATE TO THE REQUIRED GRADE. FILL MATERIAL FOR AREAS IN SUPPORT OF FOOTINGS 15 TO BE A MIXTURE OF LIMEROCK AND SAND, FREE OF VEGETATION, ORGANIC MATERIAL, CONSTRUCTION DEBRIS, AND LARGE ROCKS. IF SUFFICIENT COMPACTIBILITIES EXIST, SOILS MAY BE PLACED AND COMPACTED IN GREATER LIFT THICKNESSES. FILL MATERIAL FOR SLAB ON GRADE AREAS MAY BE CLEAN SAND, FILLED AND COMPACTED IN LIFTS NOT GREATER THAN 12 INCHES OF LOOSE MATERIAL. 4. COMPACT EACH LIFT TO A MINIMUM COMPACTION OF 95 PERCENT OF THE DRY SOIL DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST - ASTM D -1551 PRIOR TO PLACEMENT OF ANY ADDITIONAL FILL REQUIRED. PRIOR TO COMPACTION, THE MOISTURE CONTENT OF EACH LIFT OF FILL MATERIAL SHALL BE ADJUSTED TO w /IN PLUS/ MINUS 2 PERCENT OF THE OPTIMUM MOISTURE AS DETERMINED BY THE MODIFIED PROCTOR TEST - ASTM D -1551. 5. COMPACTION OF BUILDING SITE SHALL BE VERIFIED BY MEANS OF ONE FIELD DENSITY TEST FOR EACH 2510 SQUARE FEET OR FRACTION THEREOF FOR EACH LIFT OF COMPACTED SOIL FOR BUILDING PAD OR SLAB AREA ONE FIELD DENSITY TEST WILL ALSO BE REQUIRED FOR EVERY 50 LINEAL FEET OF EXCAVATED SPREAD FOOTING, AND EVERY ISOLATED FOOTING EXCAVATION. FIELD DENSITY TESTS SHALL BE PERFORMED AS PER ASTM D -2922. STRUCTURAL STEEL 1. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING GRADES: A L, 1)U`, ANGLE, BASE PLATES, CONK PLATES (UON) --- ASTM A36 (N =36 KSU B. ST RUCTURAL TUBE---- ------------ - -ASTM A-W, GRADE B (F,4=46 KSI) C. STEEL PIPE ----------------------- A5TM A53, GRADE B (FY =35 K51) 2. AT SAEPLATES NON-METALLIC SHRINK G (UCH S MASTER , AS SMALL MANUFACTURED Y HASER BB UIDR5 OR APRROVED EQUAL. 3. ALL WELDING SHALL CONFORM TO THE REQUIREMENTS OF 'THE STANDARD CODE FOR WELDING IN BUILDING CONSTRUCTION' OF THE AMERICAN WELDING SOCIETY. ALL WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS USING E10 -XX ELECTRODES. WIND DESIGN LOADS 205 'Z' E a, WIND DESIGN PER ASGE 1 -05 w/ 30' O MEAN ROOF HEIGHT + V -10' 13� WIND DESIGN SPEED 146 MPH "b �- ENGINEERED WOOD M55 24 or-.SPLICES) EXPOSURE C (O RL STRUCTURAL CATEGORY II a Kd 10 PLAN VIEW GROSS PRESSURE PER ASCE COMPONENTS AND CLADDING Q ZONES 1, 2, 4 3: ra ZONE I - 38.58 PSF TYF. LATERAL BRACE SPLICE ZONE 2 - 5434 PSF REFER TO TIE ZONE 3 - 85.84 PSF BEAM SCHEDULE Ux� '.p 1u r FOR CONTINUOUS z,,Z� IV M REINFORCEMENTS. SHOP DRAWING NOTES -WOOD TRUSSES - STRUCTURAL STEEL - FORMWORK/SHORIW.%MESHORING PRIOR TO ANY FABRICATION, SHOP DRAWINGS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR REVIEW AND APPROVAL. CONSTRUCTION JOINT 1/2 (LI or L2, WHICHEVER 15 GREATER) + 'b' STANDARD PROVIDE 1/8' SPACING AT PANEL EDGES 4'x 8' CDX PLYWOOD SHEATHING MIN. 19/32' THICK MAX. SPAN 24' PROVIDE 2'x4' BLOCKING e ALL PLYWOOD SEAMS, 48' BACK OF GABLE END. NAIL SEAM w/ 8d RS NAILS e 4'o.c. EA SIDE OF SEAM 2'x WOOD FASCIA SEE TYPICAL WALL SECTION NAILED w/ 2 -16d NAILS a EACH TRUSS 1 Vii" 1116' SPACE AT PANEL ENDS PREFABRICATED WOOD TRUSSES 24' ON CENTER SEE ROOF PLAN �--- LATERAL BRACING, SEE DETAIL ON THIS SHEET. Sd RING SHANK NAILS AT 6'o4. AT PANEL EDGE AND INTERMEDIATE SUPPORT 4'o4. a DIAPHRAGM BOUNDRY AND Sd RING SHANK NAILS a 4' o.a GABLE ENDS 4' -0' BACK OF GABLE PLYWOOD NAILING DETAIL N.T.S. REFER TO TIE BEAM SCHEDULE FOR CONTINUOUS REINFORCEMENTS. TWO 05 FILLED CELLS g TIE BEAM ELEVATION CHANGE. GN�NC�� D��T�f�AM ELEVATION SCALE. hI.T,S. 48 BAR DIAMETER 1/4 (L2) MIN. CLEAR 5PAN c.Ltftr[ or-�ry T�"PICAL CONCRETE AM /COLUMN R INFCRC M NTT SCALE: N.T.S. 0 0 0 0 I 2 RIDC:E: / I > > 2 C 2 I I 0 2 I 3 O a TYPICAL: 19/32" CDX PLYWOOD DECKING,% NAILED TO TRUSSES w /Sd RING SHANK NAILS, AS PER ZONES. ZONES > 4 (D : 6d RING% SHANK NAILS m ro'o.c. THROUGHOUT. ZONE O : 8d RING% SHANK NAILS 10 4'o.c. ROOF- PLAN SHOWING ZONES 1, 2 8c 3 TYPE D E S I G N A T,I.,O,N� 51po 2'x4' SOUTHERN YELLOW PINE 02 CROSS BRACING ES w /(2) Ibd NAILS *E5 4 TRUSS NAILED TO BOTTOM CHORD MAXIMUM 10' -0' SPACING (REFER TO TW55 NOTES 4 TRUSS LAYOUT FOR LOCATION) T x- 5RACINC; SCALE: 3/4'=V-0' 9 GAUGE DUR -O -WALL HORIZ. REIN. EVERY OTHER COURSE (LADDER TYPE). SPLICE 6' MINIMUM. LRUNNING: BOND 8'x8'xlb' CONC. MASONRY UNITS INTERLOCKED AT ALL CORNERS 4 WALL INTERSECTIONS. TYP )BUR -C -WALL CORNER DETAIL SGALE: N.T.S. 5 GAUGE DUR -O -WALL WORM REIN. EVERY OTHER COURSE (LADDER TYPE). SPLICE 8' MINIMUM. RUNNING BOND 8'x8'xlb' _j T CONC. MASONRY UNITS TYP DUR -O -WALL DETAIL SCALE: N.T.S. (2) Irod NAILS EACH MEMBER 2'x4' CONT. LATERAL WOOD BRACING NAILED TO BOTTOM CHORD MAXIMUM 10-0' SPACING (REFER TO TRUSS NOTES 4 TRUSS LAYOUT FOR LOCATION) STRUCTURAL ENGINEERS b Alex Kondrat - P.E. #58086, C.A. #00009717 ° 12900 SW 128 Street, Suite 104 a Miami, Florida 33186 a-- - , 4 Ph. (786) 293 -2888 Fax. (786) 293 -2883 _ _ ° v 0 > ° E ° 03:0 m ca�ro a m N a, ... to .� N Ln T- Ln 13� E "b �- ENGINEERED WOOD M55 24 or-.SPLICES) °E (O RL > a ._.! PLAN VIEW z Q Q ra Q W TYF. LATERAL BRACE SPLICE Y ow �n r SGALE: 3/4' =1' -m" E Ux� '.p 1u r �E z,,Z� IV M ��O on 0 � a s �, < - _ ° w Alex Kondrat & Associates, � 02 ;� w STRUCTURAL ENGINEERS b Alex Kondrat - P.E. #58086, C.A. #00009717 ° 12900 SW 128 Street, Suite 104 a Miami, Florida 33186 a-- - , 4 Ph. (786) 293 -2888 Fax. (786) 293 -2883 _ _ ° v 0 > ° E ° 03:0 m ca�ro a m N a, U N Ln T- Ln 13� W v M 0 > a ._.! W z Q Q ra LU as C � W W Q ~ Q V/ �E 0 N (.0 0 s �, ._j a � C ;� w J -, Q M 0 z W LU wO Ln a X n. a 0 "a 0 N a, U N Ln T- Ln 13� W v M 0 > W ._.! W z Q Q ra LU as C � W W Q ~ Q V/ �E 0 N (.0 0 s �, ._j a � C ;� w J -, Q M 0 z W LU wO Ln CD X n. 0 a, U Ln T- Ln U.a ifq v M V > I"1 La rq . ra LU as C 0 s �, ._j a � C ;� -, u, LU wO Ln CD X n. 0 "a ,K "i S E A L,a'1 . as C 1,41 il�� 1. •' t , Pre a � 1� �', DATE :MARCH 27 2010 ' r SCALE AS SHOWN DRAWN ;W.A.C. JOB Nil. :09.9000