Loading...
10-286-015EXIST. WINDOW/DOOR FOUNDATION NOTE5 OPENING SYMBOL 4' REINFORCED CONCRETE SLAB WITH 6X6- WI.4xWi.4 WELDED WIRE MESH (ASTM A05) m LOCATED 6 MID SLAB, SUPPORTED w/2' CHAIRS SPACED 3' -0' o.c. EACH WAY, OVER 6 MIL a VAPOR BARRIER ON CLEAN WELL COMPACTED TERMITE TREATED FILL FREE OF ORGANIC MATTER MAXIMUM SIZE OF ANY ROCKS WITHIN 12' BELOW THE FLOOR SLAB SHALL BE A MAXIMUM OF 3' IN DIAMETER ❑ 2 1 -#5 REINFORCEMENT BAR GRADE 60 IN GROUT FILLED CELL AT ALL CORNERS, NEXT t0 ALL OPENINGS, AND 48'o.c. OR UNLESS NOTED OTHERWISE. (FOR EXT WALL is FIRST FLOOR) a8'x8'x16' CONCRETE MASONRY UNITS WITH NO. 9 GAUGE LADDER TYPE JOINT REINFORCEMENT EVERY OTHER COURSE Oro' ON CENTER VERTICALLY) ® COMPRESSIVE STRENGTH OF CONCRETE FOR SLABS AND FOOTINGS SHALL BE 3,000 PSI al 28 DAYS. 5n VERIFY SIZE AND LOCATIONS OF ALL WINDOW /DOOR OPENINGS AND OPENINGS IN SLAB W/ ARCHITECTURAL DUGS. ®O = INDICATES COLUMN TYPE AND OF COLUMN. REFER TO COLUMN SCHEDULE FOR REINFORCEMENTS. r I 9 GAGE JOINT REINF., TRUSS TYPE AT EVERY SECOND COURSE. 22 GAGE CORRUGATE = DOVETAIL ANCHORS EVERY SECOND COURSE CONNECT EACH ANCHOR TO EXISTING WALL WITH �(2) 3/16' x 2' TAPCONS O= INDICATES COLUMN TYPE AND END OF COLUMN. REFER TO COLUMN SCHEDULE FOR REINFORCEMENTS. \ ` ` 5 T I N PROVIDE (2) 05 x 4' -O'lg CORNER CRACK BARS -9 ALL CORNERS OF SLAB (AS INDICATED ON PLAN)_ M745ON "T- O N IN PROVIDE 8'x8' CONCRETE SILL. REINF w/ 105 TOP 4 105 BTM 0 ALL WINDOW 511-LS (TYP). G L 0 & UfR D E T 74 I L 2 OCOMPACT INTERIOR FILL TO 959. OF MODIFIED PROCTOR MAXIMUM DRY DENSITY AS PER ASTM D - 155 5 -1 SCALE: N.T.S. AT OPTIMUM MOISTURE CONTENT. FOOTING 5CHEDULE COLUMN 6GHEDULE BOTTOM REINFORCEMENT REINFORCEMENT REMARKS REMARKS DIMENSIONS U_ o w Q A 5 C O VERTICAL HORIZONTAL TEO A 8' CONT. 8' W05 - THICKENED EDGE GI A 8' x 12' 4 -05 03 TIES s9 8'o c. CONCRETE COLUMN U,FI6 B ICa' CONT. 12' (2) 05 05 i+ 4&'o,-_ WALL FOOTING C2 A 8' x 13" 4 -«5 "3 TEES 8'o c. CONCRETE COLUMN F -i 5 36' 36' 12' (4) "5 (4) "5 CONCRETE FOOTING C3 A 8" x 16' 6 -"5 03 TIES is 8'o.c. CONCRETE COLUMN F -2 B 48• 48' 12' (4) "5 (4) «5 CONCRETE FOOTING C4 A 6' x IS" 6 -05 03 TIES a 8'o c. CONCRETE COLUMN FOOTING TYPES G5 A 8' x 19' 6 -M5 03 TIES is 8'o.c. CONCRETE COLUMN g C6 B 16' x 16' 4 -«5 - MASONRY COLUMN -- COLUMN Tl'PES: A A TY -A TYPE-13 NOTES: PROVIDE 205 CORNER BARS X 30' LONG EA. WAY, 19 ALL CONTINUOUS WALL TYPE -A TYPE-5 TYPE -C FOOTING CORNERS. I'5 DOWELS EMBEDDED INTO 45 IN 3000 PSI GROUT FILLED CELL EXISTING TIE BEAM EXISTING TIE BEAM w/ HILT[ 2000 PSF SHOULD OTHER CONDITIONS OR MATERIALS BE ENCOUNTERED, THE ENGINEER SHALL BE NOTIFIED PRIOR PROVIDE CLEANOUT AT BOTTOM TO HY -150 EPDXY SYSTEM w 16' A ENSURE PROPER FILL. ADD WEEP HOLES EMBEDMENT 15 BASED OK SEE F.B.C. DADE COUNTY 2004 EDITION SECTION 18182. _ - � - EXISTING MASONRY WALL TO REMAIN 1/3 AND 2/3 OF SPAN. FILLED CELLS is SEE ARCH PLAN SHALL BE RECOMPACTED AND RETESTED AT THE CONTRACTORS EXPENSE, AND AS DIRECTED BY THE ENGINEER U U Z WRITTEN CERTIFICATION THAT THE MINIMUM DESIGN BEARING CAPACITY, AND THAT THE COMPACTION REQUIREMENTS w/ ARCHITECTURAL PLAN. W tM CORNERS AND OPENINGS 48' O.C. OR AS FOR ELEVATION ° q .. HOOK BARS INTO FOOTI_ 12' _ - INDICATED ON FOUNDATION PLAN SEE NOTES � LL a Z G w I-0 0 ')� = o Z 9S9 AND PLANS FOR ALL WALL REINF. SPACING. W LL - 1/2' PRE MOLDED JOINT FILLER (TYP) 05 STARTER BAR - - ALL SPLICES SHALL = 4' REINFORCED CONCRETE SLAB WITH a - -- PROVIDE 10 PROVIDE I'S BE A MIN. 48 BAR DIAMETERS _ - - 6X6-W1.441.4 WELDED WIRE MESH _ VERT LOCATED e MID SLAB OVER FILLED w! - - VAPOR BARRIER ON CLEAN WELL -- -- z 3000 PSI GROUT ELEY. _ -0' -0' GOMPAGTE TERMITE TREATED FILL. f, ,\ U ELEV. = -0' -8' GRADE - _ �'�� / /�/' � �� \ PROVIDE VAPOR BARRIER EXISTING WALL- MIN. 6' EMBEDMENT .4 ° EXISTING FOOTING a ° n 105 DOWELS EMBEDDED INTO EXISTING FOOTING w/ HILTI HIT HY 150 EPDXY SYSTEM w 16' EMBEDMENT NEW FILL CELL DETAIL � SCALE: 1/4"= V-0' 2 -05 DOWELS EMBEDDED INTO EXISTING FOOTING w/ HILTI HIT HY 150 EPDX SYSTEM w /6' EMBEDMENT STEM WALL FOOTING (REFER TO FND PLAN REFER TO SCHEDULE 4 FOOTING SCHEDULE) WALL FOOTING DETAIL 4 SCALE: N.T.S. 5 -I EXISTING NEW CONCRETE COLUMN MASONRY WALL (REFER TO COLUMN SCHEDULE FOR SIZE AND REINF.) NEW MASONRY WALL a,- %— NEW FOOTING PROVIDE 2 -% BARS LOCATED 6 EXISTING FOOTING MIDDLE OF FOOTING X48' LONG D E T A I I INTO EXISTING FOOTING. J-/ +- 3 EMBEDMENT 8' w/HILTI HIT HY 150 SCALE: N.T.S. 5 -1 EPDXY SYSTEM =�r m a 8 M C� 1 a a an `� yr �n d- r� Gn (Yl 21' -ro " &2, -0" 40' -6F F -2 F_ - - - - -1 F -I - F -I F -I F -2 - �- -2 r� - 4-` - _._- .--- .----------- - -- - -- _. TES � i- .._-- ------ - - --- I I TES �' I I-- - - - - -- WFI6- - - - --I -- I —1 -- 1 / I C5 I WFi6 IL J L - _: IJ L— I— C6� m L T : 1— J C2 C2 C5 — I ICI 1 2*1 VERT REINF I I I I SEE NOTE F11 I I I SEE NOTE In �I _ I � 1 FINISHED SLABS 7 I � IU ELEY.= - 0'' -4� FINISHED 5LA5 h I I ELEV.= I I I z I I i 0�� u 101 2' -10 2_11_' -a" -� - -- --� ► 4�[ i I I C O GI � X CID It" O z -- - - - -- - - -- - _ - - -- - - -- - - -- - - - - - - - -- X -Z Z - . % ! _ 011111110 / / WFI I X'() 4 I / T�3'P / / / ! TYP / / i / / TYP / all Q I SEE NOTE � I FINISHED 5LA ,� O I ELEV.= +0'-0' I I I I� I I� c0 I � 101 a r7--/ _7' __ -- r/ _ / 7/ -.j % I 9 % /TYri� % i 0442' LONG DOWELS -0 24`0.c. EMBEDDED 4' INTO EXISTING FOOTING w/ HILTI HIT HY -150 EPDXY SYSTEM NEW CONC. SL N -- "' =1! 66! l i -1 f l = —I! 111 I- 1(1 =1TI�I I I1 I f =1 11 =9 11 =1 I I =1 I'= _I 11 1 I 1 =1 10 =1 II I I i F PROVIDE VAPOR BR IER- I =I 11 =f I I - =I 11 I f I =I f I= I I f =l f 1 r III-Ifl-lil= III -111- NEW SLA5 TO XI5TIN 5LA5 DETAIL SCALE: 1/4'= 1' -0' G4 3 I TYP p I I I I 4'-101j C4 7 - I / 21' --4" 15' -0" .... ............ IF cfA ..n O 3 '_^ 5 -I TYP - - -- - N NOTE: 2000 PSF SHOULD OTHER CONDITIONS OR MATERIALS BE ENCOUNTERED, THE ENGINEER SHALL BE NOTIFIED PRIOR N TO PROCEED1% WITH THE WORK THE ARCHITECT OR ENGINEER SHALL SUPPLY A LETTER ATTESTING THAT THE A 13� W - EXISTING CONCRETE SLAB TO REMAIN ZA 15 BASED OK SEE F.B.C. DADE COUNTY 2004 EDITION SECTION 18182. O THE OWNER SHALL RETAIN THE SERVICES OF AN INDEPENDENT GEOTECHNICAL ENGINEER TO VERIFY SUCCESSFUL � - EXISTING MASONRY WALL TO REMAIN "J SHALL BE RECOMPACTED AND RETESTED AT THE CONTRACTORS EXPENSE, AND AS DIRECTED BY THE ENGINEER U U Z WRITTEN CERTIFICATION THAT THE MINIMUM DESIGN BEARING CAPACITY, AND THAT THE COMPACTION REQUIREMENTS w/ ARCHITECTURAL PLAN. W tM . t-0 W to J HOOK BARS INTO FOOTI_ 12' 0 � LL / / Z G w I-0 0 ')� 4 4�. o Z 9S9 NEW MASONRY WALL a,- %— NEW FOOTING PROVIDE 2 -% BARS LOCATED 6 EXISTING FOOTING MIDDLE OF FOOTING X48' LONG D E T A I I INTO EXISTING FOOTING. J-/ +- 3 EMBEDMENT 8' w/HILTI HIT HY 150 SCALE: N.T.S. 5 -1 EPDXY SYSTEM =�r m a 8 M C� 1 a a an `� yr �n d- r� Gn (Yl 21' -ro " &2, -0" 40' -6F F -2 F_ - - - - -1 F -I - F -I F -I F -2 - �- -2 r� - 4-` - _._- .--- .----------- - -- - -- _. TES � i- .._-- ------ - - --- I I TES �' I I-- - - - - -- WFI6- - - - --I -- I —1 -- 1 / I C5 I WFi6 IL J L - _: IJ L— I— C6� m L T : 1— J C2 C2 C5 — I ICI 1 2*1 VERT REINF I I I I SEE NOTE F11 I I I SEE NOTE In �I _ I � 1 FINISHED SLABS 7 I � IU ELEY.= - 0'' -4� FINISHED 5LA5 h I I ELEV.= I I I z I I i 0�� u 101 2' -10 2_11_' -a" -� - -- --� ► 4�[ i I I C O GI � X CID It" O z -- - - - -- - - -- - _ - - -- - - -- - - -- - - - - - - - -- X -Z Z - . % ! _ 011111110 / / WFI I X'() 4 I / T�3'P / / / ! TYP / / i / / TYP / all Q I SEE NOTE � I FINISHED 5LA ,� O I ELEV.= +0'-0' I I I I� I I� c0 I � 101 a r7--/ _7' __ -- r/ _ / 7/ -.j % I 9 % /TYri� % i 0442' LONG DOWELS -0 24`0.c. EMBEDDED 4' INTO EXISTING FOOTING w/ HILTI HIT HY -150 EPDXY SYSTEM NEW CONC. SL N -- "' =1! 66! l i -1 f l = —I! 111 I- 1(1 =1TI�I I I1 I f =1 11 =9 11 =1 I I =1 I'= _I 11 1 I 1 =1 10 =1 II I I i F PROVIDE VAPOR BR IER- I =I 11 =f I I - =I 11 I f I =I f I= I I f =l f 1 r III-Ifl-lil= III -111- NEW SLA5 TO XI5TIN 5LA5 DETAIL SCALE: 1/4'= 1' -0' G4 3 I TYP p I I I I 4'-101j C4 7 - I / 21' --4" 15' -0" .... ............ IF cfA ..n O 3 '_^ 5 -I TYP - - -- - (j C? r. � / 'f� Ln Lt) tn LLJ a 0 oh ns LU CI- c _j IN o 0 - .. ...... Tu✓ .� �tY j P 0. F� Y 'i 25' -0" s a a DATE :MARCH 27 2010 E 0 PROPOSED REMODELATION FOUNDATION PLAN aCAL : AS SHOWN -tea 1/4" = 1' -0" 501L 5TATEMENT N NOTE: 2000 PSF SHOULD OTHER CONDITIONS OR MATERIALS BE ENCOUNTERED, THE ENGINEER SHALL BE NOTIFIED PRIOR N TO PROCEED1% WITH THE WORK THE ARCHITECT OR ENGINEER SHALL SUPPLY A LETTER ATTESTING THAT THE 13� W - EXISTING CONCRETE SLAB TO REMAIN ZA 15 BASED OK SEE F.B.C. DADE COUNTY 2004 EDITION SECTION 18182. O THE OWNER SHALL RETAIN THE SERVICES OF AN INDEPENDENT GEOTECHNICAL ENGINEER TO VERIFY SUCCESSFUL � - EXISTING MASONRY WALL TO REMAIN "J SHALL BE RECOMPACTED AND RETESTED AT THE CONTRACTORS EXPENSE, AND AS DIRECTED BY THE ENGINEER U U Z WRITTEN CERTIFICATION THAT THE MINIMUM DESIGN BEARING CAPACITY, AND THAT THE COMPACTION REQUIREMENTS w/ ARCHITECTURAL PLAN. W tM . t-0 W 1 U) C 0 � LL Z G w I-0 0 ')� o Z 9S9 W LL (j C? r. � / 'f� Ln Lt) tn LLJ a 0 oh ns LU CI- c _j IN o 0 - .. ...... Tu✓ .� �tY j P 0. F� Y 'i 25' -0" s a a DATE :MARCH 27 2010 E 0 PROPOSED REMODELATION FOUNDATION PLAN aCAL : AS SHOWN -tea 1/4" = 1' -0" 501L 5TATEMENT AS PER VISUAL INSPECTION SOIL CONDITIONS AT THIS SITE ARE SAND 4 ROCK WITH A MIN BEARING CAPACITY OF NOTE: 2000 PSF SHOULD OTHER CONDITIONS OR MATERIALS BE ENCOUNTERED, THE ENGINEER SHALL BE NOTIFIED PRIOR TO PROCEED1% WITH THE WORK THE ARCHITECT OR ENGINEER SHALL SUPPLY A LETTER ATTESTING THAT THE SITE HAS BEEN OBSERVED AND THE FOUNDATION CONDITIONS ARE SIMILAR TO THOSE UPON WHICH THE DESIGN - EXISTING CONCRETE SLAB TO REMAIN ZA 15 BASED OK SEE F.B.C. DADE COUNTY 2004 EDITION SECTION 18182. THE OWNER SHALL RETAIN THE SERVICES OF AN INDEPENDENT GEOTECHNICAL ENGINEER TO VERIFY SUCCESSFUL � - EXISTING MASONRY WALL TO REMAIN COMPLETION OF SITE PREPARATION EFFORTS, LOCATIONS FAILING TO MEET THE GEOTECHNICALS REQUIREMENTS SHALL BE RECOMPACTED AND RETESTED AT THE CONTRACTORS EXPENSE, AND AS DIRECTED BY THE ENGINEER - CONTRACTOR TO VERIFY ALL STRUCTURE DIMENSIONS WRITTEN CERTIFICATION THAT THE MINIMUM DESIGN BEARING CAPACITY, AND THAT THE COMPACTION REQUIREMENTS w/ ARCHITECTURAL PLAN. HAVE BEEN MET SHALL BE MADE BY THE GEOTECHNICAL ENGINEER -,r.- v DRAWN :W.A.C. o 1, +l..g1.309.,.P..,°ING DEPT. .� ._ > v JOB CVO. :09.9000 i. nQ z I- . P �1„9°�'� =� j C'e 0 Alex Kondrat & Associates, Inc q p STRUCTURAL ENGINEERS S-1 00009717 C.A. Alex Kondrat — P.E. #58086, # 0 a w 12900 SW 128 Street, Suite 104 _ cv� Miami, Florida 33186 0 >� c CL s of E 3:.J NO. OF Ph. (786) 293 -2888 Fax. (786) 293 -2883 ° `3 °