14-428-001
® m 1 FIRE ALARM FLOOR PLAN -N SCALE 1/8" = 1' -0" SCOPE OF WORK 1. INSTALL NEW NOTIFIER REMOTE POWER SUPPLY (FCPS -24S8) AT REFERENCED PROPERTY. _r. 2. SCOPE OF WORK IS LIMITED ONLY TO WHAT IS PROVIDED ON FLOOR PLAN AND RISER. 3. FIRE ALARM CONTROL PANEL AND REMOTE POWER SUPPLY TO BE PROTECTED BY SMOKE DETECTOR. 4. THE FACP AND REMOTE POWER SUPPLY SHALL BE LOCATED IN A MECHANICALLY VENTILATED ROOM. 5. INSTALL NEW REMOTE POWER SUPPLY AS SHOWN ON PLANS. 6. INSTALL NEW HORN /STROBES AND STROBES AS SHOWN ON PLANS. 7. PREMIER FIRE ALARMS SHALL PROVIDE A NEW ETL CENTRAL STATION FIRE ALARM CERTIFICATE AT TIME OF FIRE DEPARTMENT FINAL. 8. AUDIBLE TROUBLE SIGNAL TO BE LOCATED AT FACP. 9. SYSTEM SHALL BE A ETL CERTIFICATED CENTRAL STATION WITH 24 HOURS OF STANDBY. EXISTING INITIATING DEVICES EXISTING NOTIFICATION DEVICES. c° w G EXISTING COMMUNICATION METHOD TO MONITORING CENTRAL STATION. PI FACP PAGE 2 PHONE LINES EXISTING (BY OTHERS) PANEL CKT 120VV, , 20 AMPS 1 #12THHN - 2 #12THHN FIRST FLOOR FIRST FLOOR FIRE ALARM RISER DIAGRAM. SCALE: N.T.S. WIRE LEGEND: A - 2 #14 FPL OR THHN MINIMUM (INITIATION). B -2#16 FPL OR THHN MINIMUM (NOTIFICATION). P -2 #14 FPL OR THHN (POWER) 24 VOLTS D.C. NOTE: USE PLENUM RATED CABLE WHERE REQUIRED. FREE WIRE IS PERMITTTED IF PROTECTED FROM MECHANICAL DAMAGE. ALL CONDUITS 1/2" EMT. MINIMUM UNLESS OTHER WISE NOTED, 40% FILLED MAX. FIRE ALARM LEGEND SYM SCOPE OF WORK UNDER THIS PERMIT MANUFACTURER MODEL FRCP FIRE ALARM CONTROL PANEL (EXISTING) SIMPLEX 4001 RPS m a ^ ^ NOTIFIER FCPS -2458 IS LIMITED TO THE DEVICES WITHIN THE DASHED LINE EXISTING HORN/ STROBE WALL MOUNT (75 -110 MULTI -CD) SYSTEM SENSOR P2R STROBE (75 -110 MULTI -CD) SYSTEM SENSOR SIR O SMOKE DETECTOR SIMPLEX EXISTING Te'.,,AUDIO DEVICES BEDROOM STROBE ACCEPTED HER If AUDIO/VISUAL VISUAL -ONLY DEVICES NEVER HERE .158 .176 .176 .158 .158 .158 .158 .158 .158 .176 .158 TWO APPLIANCES IN ANY 75CD 75CD 75CD 75CD 75CD 75CD 75CD 75CD 75CD 75CD 75CD NO LESS THAN 90" NFPA 72 2007 EDITION (SECTION 7.5.4.1.2(3)) 1B L L L L L L L L EOL CKT#N1 -2 (1.792A) 175 N1 -2.1 N1 -2.2 N1 -2.3 N1 -2.4 N1 -2.5 N1 -2.6 N1 -2.7 N1 -2.8 N1 -2.9 N1 -2.10 N1 -2.11 P2 .176 .158 .158 .158 .158 .176 .158 .158 .158 .158 .158 1 1B NAC1 P.S. 75C 75CD 75CD 75CD 75CD 75CD 75CD 75CD 75CD 75CD B EOL CKT#N1 �1 (1.774A) 175 PANEL 'IA', CKT #9 120V, 20 AMPS a E-] N1 -1.1 N1 -1.2 N1 -1.3 N1 -1.4 N1 -1.5 N1 -1.6 N1 -1.7 N1 -1.8 N1 -1.9 N1 -1.10 N1 -1.11 4 i!3 p 1 #12THHN _ 2 #12THHN 2ND FLOOR 2ND FLOOR EXISTING INITIATING DEVICES EXISTING NOTIFICATION DEVICES. c° w G EXISTING COMMUNICATION METHOD TO MONITORING CENTRAL STATION. PI FACP PAGE 2 PHONE LINES EXISTING (BY OTHERS) PANEL CKT 120VV, , 20 AMPS 1 #12THHN - 2 #12THHN FIRST FLOOR FIRST FLOOR FIRE ALARM RISER DIAGRAM. SCALE: N.T.S. WIRE LEGEND: A - 2 #14 FPL OR THHN MINIMUM (INITIATION). B -2#16 FPL OR THHN MINIMUM (NOTIFICATION). P -2 #14 FPL OR THHN (POWER) 24 VOLTS D.C. NOTE: USE PLENUM RATED CABLE WHERE REQUIRED. FREE WIRE IS PERMITTTED IF PROTECTED FROM MECHANICAL DAMAGE. ALL CONDUITS 1/2" EMT. MINIMUM UNLESS OTHER WISE NOTED, 40% FILLED MAX. FIRE ALARM LEGEND SYM DESCRIPTION MANUFACTURER MODEL FRCP FIRE ALARM CONTROL PANEL (EXISTING) SIMPLEX 4001 RPS REMOTE POWER SUPPLY NOTIFIER FCPS -2458 © PULL STATION SIMPLEX EXISTING HORN/ STROBE WALL MOUNT (75 -110 MULTI -CD) SYSTEM SENSOR P2R STROBE (75 -110 MULTI -CD) SYSTEM SENSOR SIR O SMOKE DETECTOR SIMPLEX EXISTING E = EXISTING DEVICE TO REMAIN NO LESS THAN 6" BELOW FINISHED CEILING WHICHEVER IS LOWER NFPA 72 2007 EDITION (SECTION 7.4.6.1) 80" MIN 96" MAX NFPA 72 2007 EDITION (SECTION 7.5.4) FINISHED FLOOR MANUAL PU - STATION 42" MIN /54" MAX (NFPA) NFPA 72 2007 EDITION (SECTION 5.12.3,4) NOTE: MEASUREMENTS SHOWN ARE TO THE CLOSEST OF THE DETECTOR. 1 12" (MAX) 4" SIDE WALL l itf'rs•�fi�!3E + ,°ss;,'I�:'.r.:.::�+Dt.POriic:a Cnl Et.r.. i •�=Futi6: R icr° iu.-i? Ic' FTPE ALARM SYSTEM TO SE (INSTALLED EP4 A.CCOIaDANCE V Tffi NFPA 72; 70,101 FiF?E AL kltt1 qH.,. L- BE A C 1TRAL =��;i I ;;Er'7•VtC�. A CCtiTtt°tCa''� :R PLACARD S" Al � LSE. PC'6TE-D AT °[`t� -'•t:? e spc TION, P° PER-- NFPA 72 REV SIONS _ M ICT Ir- >` co Q M _ i O LL C 0 o a LO = co U o F to U 3 O LLJ Q Z Z_ <C UJ 0- u- Q O U Z Za'5° Q N s � �� r y W �_ cc i- w co a$ W w -i Z ~ Ll- r LL, 0 a LU 6 E A/ N Q IN fa° � S to LL Ln W .,--s w El i o L E -2 W W r- w .g.Ra� F- v U-1 a � Z w N y ash o: O a E.@ EL u Z O O O N O 4 � O O� Co LA. L m m clt 6c)- w W c a �O C7 W u nt z0 UO- 0 NW Ir y0 z m ) Z a_ I oLL 0 LU w O m q a cr O < C1 a vn DATE: 03 -18 -2014 SCALE: SEE PLAN DRAWN BY: M.S. CHECKED BY: R.G. SHEET FA- 1 OF 2 DEVICE MOUNTING HEIGHTS A/C SUPPLY DIFFUSER CEILING AT SMOKE/HED 3 (MIN} DETECTOR wMI ONLY 24" MIN HANDICAP Te'.,,AUDIO DEVICES BEDROOM STROBE ACCEPTED HER If AUDIO/VISUAL VISUAL -ONLY DEVICES NEVER HERE WALL MOUNTED SYNCHRONIZE MORE THAN SMOKE/HEAT TWO APPLIANCES IN ANY DETECTOR FIELD OF VIEW. MINIMUM OF 55' FROM EACH NO LESS THAN 90" NFPA 72 2007 EDITION (SECTION 7.5.4.1.2(3)) ABOVE FINISHED FLOOR NO LESS THAN 6" BELOW FINISHED CEILING WHICHEVER IS LOWER NFPA 72 2007 EDITION (SECTION 7.4.6.1) 80" MIN 96" MAX NFPA 72 2007 EDITION (SECTION 7.5.4) FINISHED FLOOR MANUAL PU - STATION 42" MIN /54" MAX (NFPA) NFPA 72 2007 EDITION (SECTION 5.12.3,4) NOTE: MEASUREMENTS SHOWN ARE TO THE CLOSEST OF THE DETECTOR. 1 12" (MAX) 4" SIDE WALL l itf'rs•�fi�!3E + ,°ss;,'I�:'.r.:.::�+Dt.POriic:a Cnl Et.r.. i •�=Futi6: R icr° iu.-i? Ic' FTPE ALARM SYSTEM TO SE (INSTALLED EP4 A.CCOIaDANCE V Tffi NFPA 72; 70,101 FiF?E AL kltt1 qH.,. L- BE A C 1TRAL =��;i I ;;Er'7•VtC�. A CCtiTtt°tCa''� :R PLACARD S" Al � LSE. PC'6TE-D AT °[`t� -'•t:? e spc TION, P° PER-- NFPA 72 REV SIONS _ M ICT Ir- >` co Q M _ i O LL C 0 o a LO = co U o F to U 3 O LLJ Q Z Z_ <C UJ 0- u- Q O U Z Za'5° Q N s � �� r y W �_ cc i- w co a$ W w -i Z ~ Ll- r LL, 0 a LU 6 E A/ N Q IN fa° � S to LL Ln W .,--s w El i o L E -2 W W r- w .g.Ra� F- v U-1 a � Z w N y ash o: O a E.@ EL u Z O O O N O 4 � O O� Co LA. L m m clt 6c)- w W c a �O C7 W u nt z0 UO- 0 NW Ir y0 z m ) Z a_ I oLL 0 LU w O m q a cr O < C1 a vn DATE: 03 -18 -2014 SCALE: SEE PLAN DRAWN BY: M.S. CHECKED BY: R.G. SHEET FA- 1 OF 2