Loading...
14-710-001ftmo&.1 .y.. -Iw4 mid. v w _DIY 4, 40 amp ft". a . 1 LOCATION SKETCH Scale 1"= NT.S. WASTE COLD WATER HOT WATER WATER CLOSE V W Bkxk 2 -- LAVATORY 1-112" 112m Back 3 �3"' 2" 1/2" 112" SINK -_../� 112w 1 �" a Q W �-9.. 3 �I VE. /Jf Z4 _ e I +- • C Sao u fs n g PER V $S (h ; I a�4 ry T`► I r. f•.rrr /� ti t, 5 4r. � � 4mN: ,(W7H 9 So•05asW SUBJECT kI &K!3d" vs `• 70.00' TOTAL RfW : 0 1 ' LOT -7 I BLOCK -1 I LOT -6 _ BLOCK -1 C N I RLP 31 __ _- _- -_ r F.I. NO 3/4' AP • NO CAP i NORTH 6' U.E. 88.00' - .� � - _ SITE PLAN wo 9 K14140F If pl' L I b. -(R 01 1 - a� jt�K &P Nov. etc, �1 Mh51Nk- L- i 'T1 y EXISTING FLOOR PLAN b I W I TE C I LOT-9 IBLOCK -1 a. I w OI I 10 OTL. 11.3'X 13' COLUMN .�� Caw. RIP 3/4- GENERAL NOTES 1. DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS ONLY. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS. IN EVENT OF CONFLICT NOTIFY ARCHITECT BEFORE PROCEEDING. 2. CONTRACTOR SHALL COORDINATE WITH OWNER AND VARIOUS TRADES SO THAT PROPER OPENINGS AND CHASES SHALL BE PROVIDED. 3. ALL VEGETATION AND ORGANIC MATTER SHALL BE REMOVED PRIOR TO PLACING FILL. FOUNDATION SHALL BEAR ON CLEAN FILL COMPACTED IN LAYERS OF NOT MORE THAN 12" DEPTH AND TO 95% DENSITY AS PER A.S.T.M. PROCTOR TEST OR MODIFIED PROCTOR TEST. CONTRACTOR SHALL SUBMIT TEST RESULTS. 4. SOIL STATEMENT: BASED ON VISUAL INSPECTION OF THE SOIL CONSISTS OF UNDISTURBED SAND & ROCK WITH MAXIMUM CAPACITY OF 2000 PSF. THE ARCHITECT OR ENGINEER SHALL SUBMIT TO THE CITY INSPECTOR A SIGNED AND SEALED LETTER ATTESTING THAT THE SITE HAS BEEN OBSERVED AND THE FOUNDATION CONDITIONS ARE SIMILAR TO THOSE UPON WHICH THE DESIGN IS BASED. 5. CONCRETE SHALL HAVE A SLUMP OF 5" MAX. AND A MIN. COMPRESSIVE STRENGTH IN 28 DAYS AS FOLLOWS:' FOUNDATIONS AND SLABS ON GRADE 3000 PSI COLUMNS AND BEAMS 3000 PSI CONCRETE COVER FOR ALL POURED IN PLACE CONCRETE SHALL BE AS FOLLOWS: FOUNDATIONS 3 INCHES COLUMNS 1 -112 INCHES SLABS ON FILL W.W.F. AT CENTER OF SLAB 6. GROUT STRENGTH 3000 PSI WITH 9" MAX. SLUMP. 7. REINFORCING STEEL SHALL CONFORM TO THE REQUIREMENTS OF A.S.T.M. A615 SPECIFICATIONS FOR NEW DEFORMED BILLET STEEL AND TO GRADE 60 SPEC. WITH A MIN. YIELD STRENGTH OF 60,000 PSI. IT SHALL BE DETAILED, FABRICATED AND PLACED AS RECOMMENDED BY A.C.I. 8. WELDED WIRE FABRIC (W.W.F.) SHALL CONFORM TO A- S.T.M. A -185, DOUBLE W.W.F. 36" ON EACH SIDE OF BEARING WALLS AND 30" AROUND PERIMETER OF MONOLITHIC FOOTINGS. 9. CONCRETE MASONRY UNITS SHALL BE LOAD BEARING TYPE CONFORMING TO A.S.T.M. C270, TYPE "M" MORTAR. 10. ALL STRUCTURAL LUMBER SHALL BE #2 SOUTHERN PINE OR BETTER. 11. ALL ROOF JOISTS, TRUSSES, OUTLOOKERS, BEAMS AND GIRDERS SHALL BE SECURED WITH APPROVED METAL TIES, CLIPS AND ANCHORS TO TIE BEAMS OR BEARING PARTITIONS. PROVIDE PRODUCT CONTROL NOTICE OF ACCEPTANCE. 12. ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED. 13. N.F.P.A. COMPLIANCE - EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPEN THE DOOR FROM INSIDE THE CLOSET. EVERY BATHROOM DOOR SHALL BE DESIGNED TO ALLOW OPENING FROM THE OUTSIDE DURING AN EMERGENCY WHEN LOCKED. NO DOOR IN THE PATH OF TRAVEL OF A MEANS OF ESCAPE SHALL BE LESS THAN 28 INCHES. 24x30 CLEARPRWO U Sup, 100 ttl PS TIFE Sam la v It �� + AM 1Rf3 ... 1 NO. R fS 11TtE VT Poo Mm ow MM tM : 'jr1.Gt? VA '170 bM PS �t : (3144 -rffHN 1"c- : 5-1151• Mdlt4 F& F, NOTE: THIS AREA SHALL COMPLY W/2008 N.E.C. 1) ALL RECEPTACLES OTHER THAN GFI RECEPTACLES SHALL HAVE ARC FAULT PROTECTION 2) ALL RECEPTACLES SHALL BE TAMPER 1/4W RESISTANT L O D r° EAST ELEVATION . '/4" WEST ELEVATION '/4" �oKTh .t flo; IN -'fo . (�I � � • t''141N �aN�Tb� -Y �IT� Ill/ trot OTE. f 1pt I1+ k-T ELECTRICAL PLAN '/4" PLUMBING PLAN 1- E=- (f=- a�E--> OF "a"r- iF==�O1 -"a ® SMOKE DETECTOR od EXTERIOR WALL MOUNT LIGHT 4D DUPLEX -cuTLET RECEPTACLE - GROUNDNG TYPE 128 V, 1S- A50VE FNI814 FLOOR GFl DUPLEX OUTLET RECEPTACLE - GR0I,NDNG TYPE 125 V, 18' ADOYE FINISH FLOOR GRO= FAULT INSULATED. CEILNG L*WWs OUTLET $-- T.Y. CABLE zS TEELE:PHONE JACK SWI -E POLE SWITCH 120 V, 44- ABOVE FINIt"4 FLOVR2 - -- -- FAN/LIGHt NORTH ELEVATION '/4" MAKE -UP LIGW . MIRROR DISCO*ECT SWITCH U CEILNG FAN 1/4 HP W/ LIGHT p Jurvcriory cox , ELECTRIC METER , GARAGE DOOR OPENER ® FLOURESICENr LIGNr Q' QUICK 0I8C044ECr 8W17104 J BOX tW FLEXABL-E CONVECTION TO EQUIPMENT 0 ELECTRICAL. PANEL r�v r v_ OUTLEt (VERIFY LOCATION IW 004ER) _.._� SPECIAL PURPOSE OUTLET (� FLOOD LrW4r UL APPROVED FOR OUTDOOR BATHROOM EXHAUST SOUTH ELEVATION 1/4" DAMPER VENT HRU ROOF ABOVE ROOF SUR ACEDWITH CGOOSE NECK EEN MESH WITH ELECTRICAL NOTES 1. DO NOT SCALE DRAWINGS. REFER TO ARCHITECTURAL PLANS AND ELEVATIONS FOR EXACT LOCATIONS OF ALL EQUIPMENT AND CONFIRM WITH OWNER REPRESENTATIVE. 2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE N.E.C. AND SHALL COMPLY WITH ALL LOCAL RULES AND ORDINANCES. 3. UNLESS OTHERWISE NOTED, MINIMUM WIRE SIZE SHALL BE NO. 12 AWG. AND ALL CONDUCTORS SHALL BE COPPER WITH TW INSULATION FOR SIZES NO. 6 AND SMALLER. CONDUCTORS LARGER THAN NO. 6 SHALL HAVE TYPE THW INSULATION ALL CONDUCTORS NO. 10 AND SMALLER MAY BE SOLID. ALL THOSE NO. 8 AND LARGER SHALL BE STRANDED. EQUIVALENT ALUMINUM CONDUCTORS CAN BE USED IN SUBFEEDERS NO. 6 OR LARGER, IF APPROVED BY LOCAL REGULATIONS. CONTRACTOR TO VERIFY. 4. ALL RACEWAYS AND PIPES PLACED IN OR THRU ANY CONCRETE SLAB SHALL BE SPACED A MINIMUM OF 3 DIAMETERS OF THE LARGEST CONDUIT OR PIPE OF ANY OTHER SERVICE. 5. ALL RACEWAYS UNDERGROUND AND /OR LARGER THAN 2 INCHES IN DIAMETER SHALL BE GALVANIZED RIGID STEEL. PVC PIPE SCH. 40 WILL BE ACCEPTABLE, IF APPROVED BY LOCAL REGULATIONS. CONTRACTOR TO VERIFY. 6. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS AND CAST ALLOY WITH THREADED HUBS IN WET OR DAMP LOCATIONS. 7. DISCONNECT SWITCHES SHALL BE QUICK MAKE, QUICK BREAK, IN NEMA 1 OR 3R ENCLOSURE, AS REQUIRED BY EXPOSURE. 8. ALL MATERIAL SHALL BE NEW AND SHALL BEAR UNDERWRITERS AND UNION LABELS WHERE APPLICABLE. TERMINATION AND WITH CORROSION RESISTANT SCR '/2" MAXIMUM MESH OPENING. 9. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IN A WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE AND ACCEPTANCE BY ENG. /ARCH. MUST BE A CONDITION OF THE CONTRACT. ELECTRICIAN SHALL INDICATE ON ELECTRICAL PANEL BOARD AREAS SERVED BY EACH C.B. 10. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH PROGRESS OF CONSTRUCTION. 11. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE OF DEFECT FOR A PERIOD OF NO LESS THAN ONE YEAR FROM THE DATE OF ACCEPTANCE. ELECTRICAL FLOOD CRITERIA 1. ELECTRICAL OUTLETS (RECEPTACLES AND LIGHTING) BELOW BASE FLOOD ELEVATION SHALL-BE INSTALLED AT THE HIGHEST PERMITTED ELEVATION AND -SHALL BE INSTALLED WITH SEPARATE INDEPENDENT CIRCUITS FROM THOSE IN THE HABITABLE AREAS. 2. NO APPLIANCE OR APPLIANCE OUTLETS SHALL' BE INSTALLED BELOW BASE FLOOD ELEVATION 3. A/C COMPRESSORS SHALL BE INSTALLED ABOVE BASE FLOOD ELEVATION 4. MAIN CIRCUIT BREAKER PANELS SHALL BE LOCATED ABOVE BASE FLOOD ELEVATION 5. COORDINATE WITH FLORIDA POWER & LIGHT COMPANY TO LOCATE THE ELECTRICAL METER TO COMPLY WITH FEDERAL EMERGENCY MANAGEMENT AGENCY REQUIREMENTS PLUMBING.,NOTES 1. VERIFY ALL SPACE CONDITIONS, DIMENSIONS AND PIPE SIZES AT PROJECT SITE PRIOR TO FABRICATION AND INSTALLATION OF MATERIALS AND EQUIPMENT. 2. COORDINATE WORK WITH OTHER TRADES. 3. PLUMBING CONTRACTOR SHALL PAY ALL FEES, INSPECTION AND CONNECTION CHARGES REQUIRED. 4. SUBMIT SHOP DRAWINGS TO ARCHITECT FOR APPROVAL OF ALL' EQUIPMENT, MATERIALS AND LAYOUT PRIOR TO INSTALLATION. 5. PLUMBING CONTRACTOR SHALL GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE. 6. PROVIDE SHUT OFF VALVE FOR EACH FIXTURE AND AIR CHAMBERS WHERE SHOWN ON-DRAWINGS AND WHERE REQUIRED FOR PROPER PERFORMANCE OF THE SYSTEM. 7. PROVIDE DIELECTRIC FITTINGS TO CONNECT PIPING OR EQUIPMENT OF DISSIMILAR METALS. 8. HOSE BIBBS SHALL BE INSTALLED 2' -0" ABOVE FINISH GRADE AND PROVIDED WITH LOCKSHIELD AND BACKFLOW PREVENTOR. 9. PROVIDE PIPING AS FOLLOWING: HOT AND COLD WATER: COPPER TUBE TYPE "M" MIN. INSTALLED WITH APPROVED FITTINGS OR BENDS. SANITARY WASTE AND VENT: PVC SCHEDULE 40 AIR CONDITIONING CONDENSATE: PVC SCHEDULE 40 10. INSULATE HOT WATER PIPING WITH PREMOLDED GLASS FIBER PIPE INSULATION. 11. PROVIDE PLUMBING FIXTURES AS SELECTED BY OWNER. 12. PROVIDE ANTI SCALD VALVES @ TUB /SHOWER COMBO 13. SANITARY PITCH: 2" & LESS @ WIFT 3" @ 118 "IFT 4" @ 1/8"/FT PLUMBING FIXTURES CONNECTION SCHEDULE WASTE COLD WATER HOT WATER WATER CLOSE V 112" -- LAVATORY 1-112" 112m 1w SHOWER 2" 1/2" 112" SINK 2" 112w 1 �" THESE PLANS COMPLY WITH THE FLORIDA RESIDENTIAL CODE 2010 AND FLORIDA EXISTING BUILDING CODE 2010 ALTERATION LEVEL 2 JRRVIQIO.FISi BY 04 tnU� p I•� � � H I as [` �xn a �M 0 3 Q hr1�l � Try M �r FBI � ey a d �o aI W W ►"+" zap �i d' d aQi oc N O LL LL W 0 � W = = a Z L O y O■. F- W Z Q O J L W � tr0�J Q j ■ 1 O■ W Q Z Date Scale ��Oww Drawn Rj t Job 291+5. Sheet Of Sheets