Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
15-235-002
�. Ep �j T GPA�T(JIENT �1R•T� AuRt� � AS � OVID0.P',itt• ".11_2_ 1KATER61A1NEXT•_ t �Rr`r���►._ -•-- O • NOTED '1� , F( mA Q QED A E OF OCC AN LZ ALL. t,E DEMOLITION PLAN LEGEND 00 EXIST COLUMNS (STEEL /CONC) TO REMAIN EXIST WALL TO REMAIN EXIST WALL /PARTITION TO BE - - -- REMOVED EXIST DOOR TO BE REMOVED AREA NOT INCLUDED IN THIS DEMOLITION PERMIT SCOPE OF WORK SCOPE OF WORK SCOPE OF WORK IS LIMITED TO INTERIOR SELECTIVE DEMOLITION NOTES _ 1. THE DEMOLITION CONTRACTOR SHALL COMPLY WITH THE DUCTWORK ON THE INTERIOR AND EXTERIOR OF THE CEILING FLORIDA BUILDING CODE CHAPTER 33 AND ALL OTHER AREAS TO BE DEMOLISHED. - REMOVE ACOUSTICAL CEILING TILE AND CROSS TEES. APPLICABLE LOCAL, STATE OR FEDERAL REGULATIONS. 8. REMOVE AND PERMANENTLY CAP ALL PLUMBING -{.IVES 2. THE OWNER SHALL NOT AUTHORIZE ANY IMPROVEMENT ON THE INTERIOR AND EXTERIOR OF THE AREAS-T6 BE ELECTRICAL OR DEMOLITION WORK UNTIL PERMIT IS SECURED FROM DEMOLISHED. ' WORK TO BE PERFORMED BY A LICENSED ELECTRICIAN. ALL THE AGENCIES HAVING JURISDICTION. 9. COORDINATE ALL DEMOLITION ACTIVITIES WITH THE 3. CONTRACTOR SHALL VERIFY WITH ALL UTILITIES FUTURE NEW CONSTRUCTION AS INDICATED IN TF'E= - SWITCHES & OTHER CONTROLS. COMPANIES (GAS, ELECTRICITY, PHONE, CABLE, WATER CONSTRUCTION DOCUMENTS. ----- REMOVE POWER OUTLETS AND SEWER, ETC.) AND STAKE OUT IN THE FIELD ALL 10. REMOVE ANY ROTTEN WOOD, OXIDIZED METAL; OR_ - IDENTIFY AND TURN OFF RELATED CIRCUITS. UNDERGROUND UTILITIES KNOWN OR ENCOUNTERED SPILLED CONCRETE THAT MAY BE FOUND. REPLACE AS INSTALL TEMP POWER FOR FUTURE INTERIOR BEFORE PROCEEDING WITH THE EXCAVATION WORK. DIRECTED OR AS REQUIRED. 4. THE ARCHITECT /ENGINEER SHALL CHECK ANY 11. PHASE DEMOLITION ACTIVITIES TO MAINTAIN THE DEMOLITION AND /OR REMOVAL OF STRUCTURAL "DRY -IN" CONDITION OF THE BUILDING INTERIOR. PLUMBING MEMBERS REQUIRED BY THESE DOCUMENTS BEFORE 12. MAINTAIN FIRE ENVELOPE INTEGRITY AT ALL TIMES ACTUAL REMOVAL. ANY ADDITIONAL DOCUMENTATION DURING DEMOLITION OPERATIONS. NECESSARY BECAUSE OF CONCEALED CONDITIONS SHALL 13. MAINTAIN CLEAR ACCESS TO AND LIGHTING OF ALL BE PREPARED AND APPROVED BEFORE CONTINUATION THE REQUIRED MEANS OF EGRESS. MAINTAIN EXISTING OF DEMOLITION ACTIVITIES. STANDPIPES AND SPRINKLER SYSTEM IN WORKING 5. REMOVE ALL INTERIOR FINISHES INCLUDING PANELING, CONDITION. CERAMIC TILES, AND FLOORING AND DROPPED CEILINGS 14. MAINTAIN NOT LESS THAN TWO 2A:10B:C FIRE AS REQUIRED BY THE CONSTRUCTION DOCUMENTS. EXTINGUISHERS LOCATED TO COMPLY WITH NFPA 10. 6. REMOVE ALL EXISTING ELECTRICAL DEVICES, LIGHTING, 15. SALVAGE ELEMENTS THAT ARE SCHEDULED TO BE CONDUIT, ETC., THROUGHOUT IN AREAS TO BE RE- INSTALLED; ALL OTHER DEBRIS SHALL BE REMOVED DEMOLISHED. FROM THE PREMISES AND DISPOSED OF IN STRICT 3. REMOVE EXISTING NON- USABLE HVAC EQUIPMENT AND ACCORDANCE WITH ALL APPLICABLE REGULATIONS. SCOPE OF WORK SCOPE OF WORK IS LIMITED TO INTERIOR SELECTIVE DEMOLITION OF THE THIRD FLOOR 4. CEILING FIRST (PARKING) AND SECOND FLOORS ARE OUTSIDE OF THE A. REMOVE ACOUSTICAL CEILING TILE AND CROSS TEES. SCOPE OF THIS PERMIT. B. REMOVE HARD CEILING (STUCCO, GWB) THROUGHOUT. 5. ELECTRICAL 1. WALLS AND PARTITIONS A. WORK TO BE PERFORMED BY A LICENSED ELECTRICIAN. A. REMOVE WALLS AIID PARTITIONS INDICATED IN THE B. REMOVE ELECTRICAL LIGHTING FIXTURES. REMOVE DRAWING. SWITCHES & OTHER CONTROLS. B. PATCH WALL FINISHES AT INTERSECTIONS OF REMOVED C. REMOVE POWER OUTLETS WALLS WITH REMAINING WALLS. D. IDENTIFY AND TURN OFF RELATED CIRCUITS. C. PATCH AND REPAR FLOOR SUBSTRATE AT LOCATIONS E. INSTALL TEMP POWER FOR FUTURE INTERIOR OF REMOVED WALLS AND PARTITIONS. CONSTRUCTION. D. REMOVE INTERIOR FURRING FROM EXTERIOR WALLS. E. REMOVE ALL INTERIOR FINISHES 6. PLUMBING 2. DOORS AND GLAZI4G A. REMOVE DOORS AhD FRAMES INDICATED IN THE DRAWING. B. EXTERIOR WINDOWS & STOREFRONTS TO REMAIN. C. IF EXTERIOR DOOR& ARE SCHEDULED FOR REMOVAL, BLOCK OPENINGS WITH 2X6 WOOD STUDS (x116 "O.C. SHEATHED WITH s" PLYWOOD ON EXTERIOR SIDE. 3. FLOORING A. REMOVE ALL FLOORING MATERIALS AND WALL BASE IN THE AREAS INDICATED IN THE DRAWING. - B. PATCH LEVEL ANC REPAIR FLOOR SUBSTRATE AS REQUIRED TO RECEIVE FUTURE NEW FLOOR. USE FLOOR LEVELER AS REQURED. A. WORK TO BE PERFORMED BY A LICENSED PLUMBER. B. REMOVE PLUMBING FIXTURES AS INDICATED IN THE DRAWING. C. CAP ALL PLUMBING CONNECTIONS, DRAINS, ETC. T. HVAC A. REMOVE ALL EXISTING NON- WORKING AIR HANDLERS B. REMOVE EXISTING DUCTWORK. C. REMOVE STEEL STRUCTURE SUPPORTING HVAC EQUIPMENT. 8. WOODWORK A. REMOVE ALL EXISTING CABINETS & FURNITURE - BUILT -IN & MOVABLE. II , II I II I II I II I II I II I II I II I II II 1 • II :3 LII II II Fr =J II L_ �L- - - - - -� LL= II 11- - - - - -- o. 41 I I a II II I I II % II II II % �I II I I II o I II II II - -- - i-- i - - - --� f--1 U I I U i1 IF , II u L-- ---- fi- -----i I ���1 I u I II In1 \�\\ -- nl In 1 ,;� iL(--�J UJLU - - -1-' iC 1 OT- II �' J II P 1 II II II IL - - - J II I I \\ I 11 II % 1F =T == Lu = = == r - - -� Fr=r� =- T -T-J11 I •• ; I I 11 � 1 I � 11 1 Ill( Az ' v OPP l 1�.«�?'..... µ� I Ir -I III "•• ___ = = =�I I i I IF - -i I111 -------------- I - - - - -- �-- r - - - - -- I'-- IL-=== = =J-31 1 ... - - -- - ��+ r - �1 \\ 1 RS .: - - - - - -E }1 I 'ci II moo' • II II II INTERIOR MODIFICATIONS ONLY (ANY EXTERIOR MODIFICATION MAY REQUIRE A BOARD APPEARANCE) N City of South Miami Tanning & Zoning rF Reviewer Date 3 10)) �5 Qr--) INTERIOR DEMOLITION PLAN nsm A�A\\\\\� C A ECFIITECTUR E & UR BAN DE S IGN :8323 -NW 12th St. Suite 106 - _ - DG[al,- FL 33126 tel: 305.593.9959 4A' #MO01093 ' infowcivi�agroup.corn PROJECT: 4 OFFICE • BUILDING 6341 SUNSET DR. SOUTH MIAMI, FL 33143 FOLIO 09- 4025- 022 -0520 EFS4 E5 CIVICA ARCHITECTURE ..' APPLICANT: ACADEMICA SUNSET, LLC 6457S UNSET DRIVE SOUTH, MIAMI, FL 33143 (305) 593 -9959 ISSUED FOR: DEMOLITION PERMIT CIVICA PROJECT No 150401 DRAWN BY APPROVED BY GD JG /RL DATE SCALE: 2015/02/23 1/4" = 1' -0" • '', KEY PLAN SEAL/SIGNATURE ROLAN AR -0( ..w EB 2 4 2015 This drawing is the property of CIVICA and is not to be reproduced or copied in whole or part. It is not to be used on any other project and is to be returned on request. COPYRIGHT © 2013 SHEET TITLE INTERIOR DEMOLITION PLAN 3RD FLOOR SHEET NUMBER P: \2015 \150401\ACAD \03 3rd\150401_D3.dwg, 2015 -02.23 16:49:27,jguillen