11-481R-001ELECTRICAL LEGEND 0 EXHAUST FAN _(� LIGHT FIXTURE ELECTRICAL DEMOLITION PLAN SCALE: 1/ " =1' -011 LIGHT COLOR DENOTES EXISTING ELECTRICAL ITEMS TO REMAIN AS IS. DARK COLOR DENOTES EXISTING ELECTRICAL ITEMS TO BE DEMOLISHED. N TELEPHONE O JUNCTION BOX GFI GROUND -FAULT INTERRUPTER QUADRUPLE RECEPTACLE MOUNTED 18" AFF U.O.N. O ELECTRICAL METER GENERAL DEMOLITION NOTES: 1. WHERE ELECTRIC LIGHTING FIXTURES, SWITCHES, RECEPTACLES;" BOXES, _ -- - - -- - CABINETS, DEVICES, ETC. ARE TO BE REMOVED, AND BOXES AND- CONDUITS ARE o N TO REMAIN, ALL CONDUCTORS SHALL BE DE— ENERGIZED, DISCONNECTED AT BOTH J ENDS, REVERSED INTO THE BOX,- AND THE BOX PLUGGED WITH CEMENT PLASTER pro= OR OTHER APPROVED MATERIAL AND THE WALL, FLOOR, - CEILING -AND THE LIKE, z_ 'yi< RESTORED TO MATCH THE SURROUNDING FINISH TO THE SATISFACTION OF THE OWNER. WHERE ANY MECHANICAL ITEMS ARE TO BE REMOVED, ALL ABOVE w FINISHES ARE TO BE RESTORED. o; 2. WHERE ELECTRICAL FIXTURES, SWITCHES, OUTLETS, RECEPTACLES, BOXES, w �••'•,••� ���v� CABINETS, DEVICES, ETC. ARE TO BE REMOVED, AND THEIR REMOVAL AFFECTS J * •z�••' �?; THE OPERATION OF ANY EQUIPMENT, FIXTURE, RECEPTACLES, ETC. THAT IS TO a ��';�,. REMAIN (INCLUDING ITEMS THAT MAY NOT BE SHOWN IN THE DRAWINGS BUT ARE o Q a .4-0 t Do PRESENTLY EXISTING IN PLACE) THE CONTRACTOR SHALL RECIRCUIT THEM Cn L� ri (INCLUDING BOXES, CONDUIT, WIRES, ETC.) TO RESTORE THEM TO THE LL,_I ° a- ORIGINAL OPERATING CONDITION, ALL AT NO ADDITIONAL COST TO THE OWNER. 0 LrJ o � o ° Q 3. UNUSED OPENINGS IN BOXES, CABINETS, PANEL BOARDS, ROOFS, ETC., r2 < ¢ vi = WHERE SOMETHING IS REMOVED OR PREVIOUSLY EXISTED —SHALL BE PLUGGED OR LL_ E ,n •• BLANKED OUT BY APPROVED METHODS, IF THE -- OPENING IS TO REMAIN. w Q N Q w 4. ALL EXPOSED CONDUIT, WIRES, OUTLETS, ETC. NOT TO BE REUSED IN THE NEW 0 w :2 O U REMODELED LAYOUT, SHALL BE REMOVED. J ............ ............................... 5. EXISTING PIPE OR CONDUIT RUNS, STUBBING UP THRU FLOORS, IN AREAS WHERE WALLS ARE TO BE REMOVED, SHALL HAVE THEIR CONDUCTORS DE— ENERGIZED AND REMOVED, CONDUIT CUT —OFF GROUND FLUSH WITH FLOOR AND PLUGGED WITH CEMENT MORTAR OR ANY OTHER APPROVED MATERIAL THE SAME APPLIES WITH EXISTING CONDUITS OR PIPES THAT ARE STUBBED OUT OF WALLS AND FLOORS. 6. WHERE PRACTICAL, EXISTING CONDUCTORS AND WIRES THAT ARE IN GOOD CONDITION, MAY BE REUSED IN PLACE AND INCORPORATED IN THE NEW REMODELED LAYOUT, PROVIDED IT IS OF PROPER SIZE, TYPE OF CONDUCTOR AND WITH THE APPROVAL OF THE OWNER. 7. ABANDONED CIRCUIT CONDUCTORS IN PANELBOARDS, SHALL BE DISCONNECTED, TAPED AND IDENTIFIED. 8. SALVAGED ITEMS SHALL BE RETURNED TO THE OWNER, AND DELIVERED WHERE DIRECTED BY HIM. ITEMS AND MATERIALS CONSIDERED UNSALVAGEABLE BY THE OWNER, SHALL BE DISPOSED OF AS DIRECTED BY THE OWNER. REMOVED WALL SWITCHES, DIFFUSERS, RECEPTACLES AND LIGHTING OR PLUMBING FIXTURES SHALL NOT BE REUSED IN NEW CONSTRUCTION. 9. ALL ROOF OPENINGS OR WALL OPENINGS WHERE MECHANICAL OR ELECTRICAL DEVICES OR OTHER ITEMS ARE TO BE REMOVED SHALL BE RESTORED AND FINISHED TO A FINAL FINISH, AND WATER PROOFED. GENERAL ELECTRICAL NOTES 1 . ALL WORK SHALL BE IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE, FLORIDA BUILDING CODE AND OTHER APPLICABLE CODES AND STANDARDS. 2 . a) THE DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW ALL OFFSETS, BENDS AND BOXES REQUIRED TO MAKE A COMPLETE NEAT INSTALLATION IN ACCORDANCE WITH N.E.C. b) WHEN CONFLICTS ARISE IN LOCATIONS WIRING DEVICES, ELECTRICAL EQUIPMENT, DISCONNECTS, PANELBOARDS, ETC. DUE TO FIELD CONDITION OR IMPROPER FIELD COORDINATION CONTRACTOR SHALL BRING IT TO THE A / E's ATTENTION AND AT NO EXTRA COST RELOCATE, AND OR EXTEND WITHIN A REASONABLE DISTANCE SUCH ITEM WHICH IS IN CONFLICT. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING LOCATION OF ALL COMPONENT PRIOR TO ROUGH IN WITH ALL TRADES NO EXTRAS WILL BE ALLOWED FOR FAILURE TO DO SO. 3 . THE CONTRACTOR IS RESPONSIBLE FOR EVALUATING FIELD CONDITIONS BY VISITING THE SITE PRIOR TO COMMENCING / BIDDING WORK. 4 . THE CONTRACTOR SHALL SATISFACTORILY REPAIR /REPLACE EQUIPMENT OR PART OF STRUCTURE DAMAGED AS A RESULT OF HIS WORK. SURFACES AND FINISHED AREAS SHALL BE RESTORED TO MATCH ADJACENT AREAS. 5 . APPROVAL SHALL BE OBTAINED FROM AN STRUCTURAL ENGINEER PRIOR TO CUTTING OR DRILLING ANY STRUCTURAL SUPPORT MEMBER. 6 . ALL DEVICE BOXES SHALL BE INSTALLED FLUSH AND CONDUITS RUN CONCEALED IN FINISHED AREAS EXCEPT AS SPECIFICALLY SHOWN /NOTED OTHERWISE. 7 . ALL ELECTRICAL EQUIPMENT SHALL BE REMOVED FROM STRUCTURE TO BE REMOVED. ACCESSIBLE RACEWAYS, WIRES, BOXES, SWITCHES AND OTHER ELECTRICAL ITEMS ASSOCIATED WITH THIS WORK SHALL BE REMOVED IF NOT REQUIRED FOR NEW EQUIPMENT TO CONTINUE IN SERVICE. 8 . WIRE SHALL BE REMOVED BACK TO SOURCE FROM INACCESSIBLE RACEWAYS NOT REUSED. INSTALL BLANK PLATES ON FLUSH OUTLETS NOT REUSED. PLATE COLOR SHALL MATCH ADJACENT SURFACE AS NEAR AS POSSIBLE IN FINISHED AREAS. 9 . INSTALL POWER AND CONTROL WIRING AND REQUIRED CONTROL COMPONENTS FOR AIR CONDITIONING SYSTEMS AS SHOWN /NOTED ON THESE DRAWINGS AND PER OTHER APPLICABLE DRAWINGS / INSTRUCTIONS. SEE AIR CONDITIONING DRAWING. 10 . ALL MATERIAL REMOVED SHALL BE DISPOSED OF AS DIRECTED BY OWNER. 11 . WIRE SIZE SHALL BE 12 THHN / THWN UNLESS OTHERWISE NOTED ON PLANS. 14 ALL WIRES SHALL BE THWN. INSULATION. 15 . ALL CONDUCTOR SHALL BE COPPER. 16 . ALL CONDUCTORS SHALL BE RUN IN CONDUIT (METALLIC TYPE). IF PVC SCHEDULE 40 IS USED FOR UNDERGROUND FEEDERS ONLY, AN EQUIPMENT GROUND CONDUCTOR SIZED IN ACCORDANCE WITH N.E.C. 250 -122 MUST BE INSTALLED AND CONDUIT SIZE INCREASE AS REQUIRED. 17 . ALL MATERIALS SHALL BE U.L. APPROVED. 18 NEW TYPEWRITTEN PANEL TALLY SHALL BE FURNISHED AFTER JOB IN COMPLETED REFLECTING ALL CHANGES AND ADDITIONS. 19 . ALL BRANCH CIRCUITS SHALL BE PROPERLY PHASE BALANCED. 20 SEE ARCHITECTURAL DRAWING FOR INFORMATION CONCERNING EXISTING CONDITIONS, NEW WORK AND COUNTER DETAILS. 21 ALL WIRING DEVICES TO BE SPECIFICATION GRADE WITH HIGH ABUSE NYLON COVER PLATES EQUAL TO LEVITON 53500 SERIES (SWITCHES); 5252 SERIES (RECEPTACLES). 22 ALL BRANCH CIRCUITS TO HAVE A GREEN EQUIPMENT GROUNDING CONDUCTOR SIZED AS PER N.E.C. 250.122. 23 . FUSES SHALL BE DUAL ELEMENT, TIME DELAY TYPE UNLESS OTHERWISE NOTED. 24 . A/C EQUIPMENT WIRING, BREAKER AND FUSE SIZES ARE BASED ON A/C EQUIPMENT SPECIFIED ON CONTRACT DRAWING. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING, BREAKER AND FUSES SIZES IN ACCORDANCE WITH A/C EQUIPMENT NAMEPLATE REQUIREMENTS IF DIFFERENT FROM THAT SPECIFIED ON DRAWINGS, AS WELL AS ANY FEEDER CHANGES BEING AFFECTED BY THIS CHANGE CONTRACTOR SHALL MAKE ABOVE MENTIONED CHANGES AT NO EXTRA COST. 25 . CONTRACTOR SHALL COORDINATE ALL HIS WORK WITH OTHER TRADES IN OTHER TO FURNISH AND INSTALL ALL CONTROL WIRING AND RACEWAYS, ALL POWER CONTROL CIRCUIT WIRING AND RACEWAY AS SHOWN ON THE AIR CONDITIONING DRAWING OR SPECIFICATIONS. IF AIR CONDITIONING IF DRAWING REFER TO MANUFACTURERS WIRING DIAGRAMS, THE CONTRACTOR SHALL VERIFY WITH SAID MANUFACTURER ALL REQUIREMENTS AND INCLUDE ALL RELATED WORK IN HIS CONTRACT. 26 SWITCH ®= DUPLEX RECEPTACLE NP WEATHER -PROOF B ELECTRIC PANEL L❑ DISCONNECT 0 EXHAUST FAN _(� LIGHT FIXTURE ELECTRICAL DEMOLITION PLAN SCALE: 1/ " =1' -011 LIGHT COLOR DENOTES EXISTING ELECTRICAL ITEMS TO REMAIN AS IS. DARK COLOR DENOTES EXISTING ELECTRICAL ITEMS TO BE DEMOLISHED. N TELEPHONE O JUNCTION BOX GFI GROUND -FAULT INTERRUPTER QUADRUPLE RECEPTACLE MOUNTED 18" AFF U.O.N. O ELECTRICAL METER GENERAL DEMOLITION NOTES: 1. WHERE ELECTRIC LIGHTING FIXTURES, SWITCHES, RECEPTACLES;" BOXES, _ -- - - -- - CABINETS, DEVICES, ETC. ARE TO BE REMOVED, AND BOXES AND- CONDUITS ARE o N TO REMAIN, ALL CONDUCTORS SHALL BE DE— ENERGIZED, DISCONNECTED AT BOTH J ENDS, REVERSED INTO THE BOX,- AND THE BOX PLUGGED WITH CEMENT PLASTER pro= OR OTHER APPROVED MATERIAL AND THE WALL, FLOOR, - CEILING -AND THE LIKE, z_ 'yi< RESTORED TO MATCH THE SURROUNDING FINISH TO THE SATISFACTION OF THE OWNER. WHERE ANY MECHANICAL ITEMS ARE TO BE REMOVED, ALL ABOVE w FINISHES ARE TO BE RESTORED. o; 2. WHERE ELECTRICAL FIXTURES, SWITCHES, OUTLETS, RECEPTACLES, BOXES, w �••'•,••� ���v� CABINETS, DEVICES, ETC. ARE TO BE REMOVED, AND THEIR REMOVAL AFFECTS J * •z�••' �?; THE OPERATION OF ANY EQUIPMENT, FIXTURE, RECEPTACLES, ETC. THAT IS TO a ��';�,. REMAIN (INCLUDING ITEMS THAT MAY NOT BE SHOWN IN THE DRAWINGS BUT ARE o Q a .4-0 t Do PRESENTLY EXISTING IN PLACE) THE CONTRACTOR SHALL RECIRCUIT THEM Cn L� ri (INCLUDING BOXES, CONDUIT, WIRES, ETC.) TO RESTORE THEM TO THE LL,_I ° a- ORIGINAL OPERATING CONDITION, ALL AT NO ADDITIONAL COST TO THE OWNER. 0 LrJ o � o ° Q 3. UNUSED OPENINGS IN BOXES, CABINETS, PANEL BOARDS, ROOFS, ETC., r2 < ¢ vi = WHERE SOMETHING IS REMOVED OR PREVIOUSLY EXISTED —SHALL BE PLUGGED OR LL_ E ,n •• BLANKED OUT BY APPROVED METHODS, IF THE -- OPENING IS TO REMAIN. w Q N Q w 4. ALL EXPOSED CONDUIT, WIRES, OUTLETS, ETC. NOT TO BE REUSED IN THE NEW 0 w :2 O U REMODELED LAYOUT, SHALL BE REMOVED. J ............ ............................... 5. EXISTING PIPE OR CONDUIT RUNS, STUBBING UP THRU FLOORS, IN AREAS WHERE WALLS ARE TO BE REMOVED, SHALL HAVE THEIR CONDUCTORS DE— ENERGIZED AND REMOVED, CONDUIT CUT —OFF GROUND FLUSH WITH FLOOR AND PLUGGED WITH CEMENT MORTAR OR ANY OTHER APPROVED MATERIAL THE SAME APPLIES WITH EXISTING CONDUITS OR PIPES THAT ARE STUBBED OUT OF WALLS AND FLOORS. 6. WHERE PRACTICAL, EXISTING CONDUCTORS AND WIRES THAT ARE IN GOOD CONDITION, MAY BE REUSED IN PLACE AND INCORPORATED IN THE NEW REMODELED LAYOUT, PROVIDED IT IS OF PROPER SIZE, TYPE OF CONDUCTOR AND WITH THE APPROVAL OF THE OWNER. 7. ABANDONED CIRCUIT CONDUCTORS IN PANELBOARDS, SHALL BE DISCONNECTED, TAPED AND IDENTIFIED. 8. SALVAGED ITEMS SHALL BE RETURNED TO THE OWNER, AND DELIVERED WHERE DIRECTED BY HIM. ITEMS AND MATERIALS CONSIDERED UNSALVAGEABLE BY THE OWNER, SHALL BE DISPOSED OF AS DIRECTED BY THE OWNER. REMOVED WALL SWITCHES, DIFFUSERS, RECEPTACLES AND LIGHTING OR PLUMBING FIXTURES SHALL NOT BE REUSED IN NEW CONSTRUCTION. 9. ALL ROOF OPENINGS OR WALL OPENINGS WHERE MECHANICAL OR ELECTRICAL DEVICES OR OTHER ITEMS ARE TO BE REMOVED SHALL BE RESTORED AND FINISHED TO A FINAL FINISH, AND WATER PROOFED. GENERAL ELECTRICAL NOTES 1 . ALL WORK SHALL BE IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE, FLORIDA BUILDING CODE AND OTHER APPLICABLE CODES AND STANDARDS. 2 . a) THE DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW ALL OFFSETS, BENDS AND BOXES REQUIRED TO MAKE A COMPLETE NEAT INSTALLATION IN ACCORDANCE WITH N.E.C. b) WHEN CONFLICTS ARISE IN LOCATIONS WIRING DEVICES, ELECTRICAL EQUIPMENT, DISCONNECTS, PANELBOARDS, ETC. DUE TO FIELD CONDITION OR IMPROPER FIELD COORDINATION CONTRACTOR SHALL BRING IT TO THE A / E's ATTENTION AND AT NO EXTRA COST RELOCATE, AND OR EXTEND WITHIN A REASONABLE DISTANCE SUCH ITEM WHICH IS IN CONFLICT. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING LOCATION OF ALL COMPONENT PRIOR TO ROUGH IN WITH ALL TRADES NO EXTRAS WILL BE ALLOWED FOR FAILURE TO DO SO. 3 . THE CONTRACTOR IS RESPONSIBLE FOR EVALUATING FIELD CONDITIONS BY VISITING THE SITE PRIOR TO COMMENCING / BIDDING WORK. 4 . THE CONTRACTOR SHALL SATISFACTORILY REPAIR /REPLACE EQUIPMENT OR PART OF STRUCTURE DAMAGED AS A RESULT OF HIS WORK. SURFACES AND FINISHED AREAS SHALL BE RESTORED TO MATCH ADJACENT AREAS. 5 . APPROVAL SHALL BE OBTAINED FROM AN STRUCTURAL ENGINEER PRIOR TO CUTTING OR DRILLING ANY STRUCTURAL SUPPORT MEMBER. 6 . ALL DEVICE BOXES SHALL BE INSTALLED FLUSH AND CONDUITS RUN CONCEALED IN FINISHED AREAS EXCEPT AS SPECIFICALLY SHOWN /NOTED OTHERWISE. 7 . ALL ELECTRICAL EQUIPMENT SHALL BE REMOVED FROM STRUCTURE TO BE REMOVED. ACCESSIBLE RACEWAYS, WIRES, BOXES, SWITCHES AND OTHER ELECTRICAL ITEMS ASSOCIATED WITH THIS WORK SHALL BE REMOVED IF NOT REQUIRED FOR NEW EQUIPMENT TO CONTINUE IN SERVICE. 8 . WIRE SHALL BE REMOVED BACK TO SOURCE FROM INACCESSIBLE RACEWAYS NOT REUSED. INSTALL BLANK PLATES ON FLUSH OUTLETS NOT REUSED. PLATE COLOR SHALL MATCH ADJACENT SURFACE AS NEAR AS POSSIBLE IN FINISHED AREAS. 9 . INSTALL POWER AND CONTROL WIRING AND REQUIRED CONTROL COMPONENTS FOR AIR CONDITIONING SYSTEMS AS SHOWN /NOTED ON THESE DRAWINGS AND PER OTHER APPLICABLE DRAWINGS / INSTRUCTIONS. SEE AIR CONDITIONING DRAWING. 10 . ALL MATERIAL REMOVED SHALL BE DISPOSED OF AS DIRECTED BY OWNER. 11 . WIRE SIZE SHALL BE 12 THHN / THWN UNLESS OTHERWISE NOTED ON PLANS. 14 ALL WIRES SHALL BE THWN. INSULATION. 15 . ALL CONDUCTOR SHALL BE COPPER. 16 . ALL CONDUCTORS SHALL BE RUN IN CONDUIT (METALLIC TYPE). IF PVC SCHEDULE 40 IS USED FOR UNDERGROUND FEEDERS ONLY, AN EQUIPMENT GROUND CONDUCTOR SIZED IN ACCORDANCE WITH N.E.C. 250 -122 MUST BE INSTALLED AND CONDUIT SIZE INCREASE AS REQUIRED. 17 . ALL MATERIALS SHALL BE U.L. APPROVED. 18 NEW TYPEWRITTEN PANEL TALLY SHALL BE FURNISHED AFTER JOB IN COMPLETED REFLECTING ALL CHANGES AND ADDITIONS. 19 . ALL BRANCH CIRCUITS SHALL BE PROPERLY PHASE BALANCED. 20 SEE ARCHITECTURAL DRAWING FOR INFORMATION CONCERNING EXISTING CONDITIONS, NEW WORK AND COUNTER DETAILS. 21 ALL WIRING DEVICES TO BE SPECIFICATION GRADE WITH HIGH ABUSE NYLON COVER PLATES EQUAL TO LEVITON 53500 SERIES (SWITCHES); 5252 SERIES (RECEPTACLES). 22 ALL BRANCH CIRCUITS TO HAVE A GREEN EQUIPMENT GROUNDING CONDUCTOR SIZED AS PER N.E.C. 250.122. 23 . FUSES SHALL BE DUAL ELEMENT, TIME DELAY TYPE UNLESS OTHERWISE NOTED. 24 . A/C EQUIPMENT WIRING, BREAKER AND FUSE SIZES ARE BASED ON A/C EQUIPMENT SPECIFIED ON CONTRACT DRAWING. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING, BREAKER AND FUSES SIZES IN ACCORDANCE WITH A/C EQUIPMENT NAMEPLATE REQUIREMENTS IF DIFFERENT FROM THAT SPECIFIED ON DRAWINGS, AS WELL AS ANY FEEDER CHANGES BEING AFFECTED BY THIS CHANGE CONTRACTOR SHALL MAKE ABOVE MENTIONED CHANGES AT NO EXTRA COST. 25 . CONTRACTOR SHALL COORDINATE ALL HIS WORK WITH OTHER TRADES IN OTHER TO FURNISH AND INSTALL ALL CONTROL WIRING AND RACEWAYS, ALL POWER CONTROL CIRCUIT WIRING AND RACEWAY AS SHOWN ON THE AIR CONDITIONING DRAWING OR SPECIFICATIONS. IF AIR CONDITIONING IF DRAWING REFER TO MANUFACTURERS WIRING DIAGRAMS, THE CONTRACTOR SHALL VERIFY WITH SAID MANUFACTURER ALL REQUIREMENTS AND INCLUDE ALL RELATED WORK IN HIS CONTRACT. 26 ALL LUMINARIES SHALL BE PROPERLY SUPPORTED IN ACCORDANCE WITH THE CEILING SYSTEM MANUFACTURER RECOMMENDATIONS AND LOCAL CODE REQUIREMENTS. �• 27 . RISERS ARE DIAGRAMMATIC ONLY. THEY DO NOT SHOW EVERY BEND REQUIRED FOR �' THE INSTALLATION. t 28 . THIS DRAWING IS A GUIDE FOR THE ELECTRICAL INSTALLATION . THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE A FUNCTIONING SYSTEM. W 29 . ALL CABLES SHALL BE RUN WITHOUT SPLICES EXCEPT OTHERWISE INDICATED. Q 30 . ALL PULL AND JUNCTION BOXES SHALL BE ACCESSIBLE AT ALL TIMES. u f 31 . EXACT POINT AND METHODS OF CONNECTION SHALL BE DETERMINED IN FIELD. /�� VJ Q 32 . ALL WORK SHALL BE DONE IN A NEAT AND WORKMANLIKE MANNER. Q Q ^' 33 . BRANCH CIRCUIT BREAKERS SHALL BE OF THE BOLT —ON TYPE. PLUG IN CIRCUIT r/ BREAKERS WILL NOT BE ACCEPTED. O 34 . ALL NEW BRANCH CIRCUIT BREAKERS SHALL MATCH EXISTING CONDUCTOR SIZE IF CONDUCTOR SIZE IS LESS THAN CIRCUIT BREAKER SIZE, CHANGE CONDUCTOR J TO MATCH CIRCUIT BREAKER. FOR EXISTING MOTOR, NOTIFY ENGINEER BEFORE LL ROUGHING —IN. / � C n — 35 . ALL LOAD IN EXISTING PANELBOARDS ARE ESTIMATED. nO 't.r1J 36 . ALL RACEWAY ROUTED, INSULATED CONDUCTORS SYSTEM SHALL BE COLOR CODED L� J AS FOLLOWS. O 120/240 V SYSTEM PHASE "A" BLACK PHASE "B" RED NEUTRAL WHITE (1 GROUND GREEN l_L_ 37 . ALL ROUGH IN DIMENSION ARE TO CENTER LINE OF DEVICE UNLESS OTHERWISE NOTED. 38 . CONTRACTOR TO PROVIDE END LINE FUSES FOR FLUORESCENT LIGHT FIXTURES. 39 . CONTRACTOR IS ALLOWED TO REARRANGE THE DISTRIBUTION OF THE ELECTRICAL LOADS CONNECTED TO BRANCH CIRCUITS IN FIELD AS LONG AS LOAD BALANCE & INDEPENDING CIRCUIT LOADING IS IN COMPLIANCE WITH NEC. 49 . FLEXIBLE CONDUIT SHALL BE USED FOR CONNECTION TO ALL VIBRATING EQUIPMENT SUCH AS MOTORS. 40 . ELECTRICAL CONTRACTOR SHALL VERIFY THE CEILING FINISHES AND SUSPENSION SYSTEM FOR SELECTION OF THE PROPER TRIM AND SUPPORT ARRANGEMENT OF THE FIXTURE. 41 . WHEN INSTALLING J. BOXES ® FIRE RATED WALLS: a) J. BOXES TO BE SPACED 6" MIN. WITHOUT EXCEEDING THE NEC SPACING 1Q 8/25/11 REQUIREMENTS. b) PROVIDE 2 HOURS FIRE RATED PUTTY PAD AS MANUFACTURED BY 3M. 42 . DISCONNECTING MEANS. EACH MULTIWIRE BRANCH CIRCUIT SHALL HAVE A MEANS TO SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS AT THE POINT WHERE THE BRANCH CIRCUIT ORIGINATES 43 . GROUPING. THE UNGROUNDED AND NEUTRAL CONDUCTORS OF A MULTIWIRE BRANCH CIRCUIT SHALL BE GROUPED TOGETHER IN AT LEAST ONE LOCATION BY WIRE TIES OR SIMILAR MEANS AT THE POINT OF ORIGINATION 44 . ALL 15A AND 20A, 125V RECEPTACLES INSTALLED WITHIN 6 FT OF THE OUTSIDE EDGE OF THE SINK SHALL BE GFCI — PROTECTED 45 . OVERCURRENT DEVICES SHALL NOT BE LOCATED OVER STEPS OF A STAIRWAY 46 . AN EQUIPMENT BONDING JUMPER IS NOT REQUIRED FOR RECEPTACLES ATTACHED TO Drawn By. LISTED EXPOSED WORK COVERS WHEN THE RECEPTACLE IS ATTACHED TO THE COVER WITH TWO PERMANENT FASTENERS (RIVETS), OR HAVE A THREADED OR SCREW R. B. LOCKING MEANS; AND THE COVER MOUNTING HOLES ARE LOCATED ON A FLAT NON— RAISED PORTION OF THE COVER Checked: 47 . ALL OVER CURRENT PROTECTION DEVICES SHALL BE SERIES COORDINATED FOR AN INTEGRATED INTERRUPTIVE CAPACITY GREATER THAN THE EXISTING AT ELECTRICAL SERVICE POINT Date: 47 . ALL PANELBOARDS OR SWITCHBOARDS TO HAVE A SIGN SPECIFYING THAT THE 08/25/11 HIGH —LEG (PHASE B) VOLTAGE TO GROUND IS 208 V. Scale: 48 . ALL SWITCHBOARDS, PANELBOARDS, METER SOCKETS, & ALL OTHER PANELS TO HAVE A SIGN TO READ AS FOLLOW: ARC FLASH HAZARD. APPROPRIATE PPE REQUIRED AS Shown 49 . CONTRACTOR TO INCREASE FEEDER SIZE AS NECCESARY TO PROVIDE A MAXIMUM Sheet: VOLTAGE DROP OF 2% 50 . MINIMUM COVER MUST BE PROVIDED FOR UNDERGROUND RACEWAYS OR CABLES TO COMPLY WITH NEC 300.5 E-1 m