Loading...
11-481-020MATCH LINE o < I `�.FAN 1Z • CLG. OPEN TO ABi `' 1< <`'•'' ill' MEZZANINE SPACE X, 77 711 >- w a r% �> 11?NK/ Z C 74 - N, II'Ll I IBBY EXIST. E I I < NEW < SINK C� CL CLG. OPEN TO ABOVE CLA 0 #3 MEZZANINE SPACE SA r2.2 �ju 1,1-ft I REFER TO MEZZINE FLOORI PLAN FOR CONTI I ON. z N Uj M E '.° ~ _ `- ill! I v NEW @-2,-00 An Uj V) < rww� CB CLG. 0 FIEN TO ABOVE MEZZA INE SPACE CL-G. OPF TO ABOVE MEZZANINE SPACE GU SHALL BE INSTALLED 01 FBC SECffJft3V M < THE HURRICANE FORCE VSRRAL Uj CLG. OPE ABOVE z MEZZANIN1f SPACE Uj _71AZI /1T z =J I EXIST. R 7-CEPTION I Wi V) of CB CLG. 0 FIEN TO ABOVE MEZZA INE SPACE CL-G. OPF TO ABOVE MEZZANINE SPACE GU SHALL BE INSTALLED AS FER FBC SECffJft3V hIFBC/ TO RESIT THE HURRICANE FORCE VSRRAL REFE' M-2 FOR DETAILS. ih STAIR TO CE) II I I ti` t L 7n Lj 0 DAH94 " EXISTING 4 CONCRETE PAD TO I --- - - IC-4s,&Roqm#5 EXTENDED AS REQUIRED TO I SQ.FT. ACCOMMODATED NEW C.U- .2 4 B R E� rp-�24X©24X8 NEW. CU LOCATION 18X10 FROM \=/250 CFM SHALL BE COORDINATED 12X10 FR MEZZANINE F­___1 W/PLENUM I AT SITE BY ARCH. MEZZANI ABOVE REFI IN ABOVE R TO M2 7 N I 0 M2 FOR CONT. L __j NEW. CU-3 FOR CO N (5.0 TN) T NEW NEW W '4 (�)11 Oxi 0 Tr 18X10 16X8 1 L 80 CFM --- - - - - - - - - - - NEW 12X8 O/A F 1(2)8"OFLdX 1 X 8 X FR 2 0 FM ABOVE B 22XII 0 A�^ w w 1 6,01 1 A . . . ..... ... (3.0 TN r 11 NEV NEW. CU -4 TT T7 2X8 O/Al (=213"OFLEX _J 777277771 ey ci L_ _j ---------------- 0 3/4-CD ATA (2), 1 ',307.8 1. CFA (g� /A 460 22X1 CFM HVAC— KEY NOTES PROVIDE SMOKE DETECTOR EXISTING AHU-3, LOCATED AT MEZZANINE, TO OPEN (1) EXISTING DIFFUSER AND/OR RETURN GRILL IN SPACE TO REMAIN AS IS. THIS AREA TO REMAIN AS IS. REBALANCE AS NOTED 0 EXISTING 10"0 OUTSIDE AIR DUCTWORK. (2) TIE-IN TO EXISTING CD LINE. VERIFY EXACT REBALANCE AS NOTED. PROVIDE NEW MOTORIZED LOCATION BEFORE JOB COMMENCEMENT. VOLUME DAMPER (1) FULL LOUVER DOOR. EXISTING WALL CAP SHALL BE 10'MIN FROM ANY EXHAUST AIR. CONTRACTOR TO VERIFY CONDITION RUN REFRIGERANT PIPING IN CLG SPACE AT SITE. NEW PROGRAMMABLE THERMOSTAT (ID EXISTING THERMOSTAT TO REMAIN AS IS, FULL SIZE DISCHARGE PLENUM EXISTING C.D AND REFRIGERANT LINES TO CONNECT NEW DUCTWORK TO EXISTING REMAIN AS IS. DUCTWORK. VERIFY POINT OF CONNECTION NEW OUTSIDE AIR DUCTWORK SHALL BE AND PROVIDE TRANSITION AS REQUIRED. COORDINATED AT SITE TO AVOID ANY STRUCTURAL INTERFERENCE. NOTIFIED ENGINEER EXISTING DUCTWORK TO BE CAPPED AS SHOWN. FOR ANY DISCREPANCY EXISTING EXHAUST FAN TO REMAIN AS IS. NEW 12X8 OUTSIDE AIR DUCTWORK ENDS BELOW NEW FLEX TO BE CONNECTED TO EXISTING AHU RETURN PLENUM. PROVIDE VOLUME MOTORIZED DIFFUSER GRILL. DAMPER. BALANCE AS NOTED. D EXISTING FLEX. TO BE EXTENDED AND CONNECTED COORD. NEW O/A LOUVER HEIGHT AT SITE TO NEW DUCTWORK. VERIFY FLEX SIZE AS NOTED. NEW EX. FAN. CONNECT NEW 4"EX. DUCTWORK TO Q EXISTING DIFFUSER GRILLS LOCATED AT EXISTING DUCTWORK. VERIFY LOCATION. MEZZANINE SPACE. REBALANCE AS NOTED NEW REFRIGERANT LINES (D PROVIDE NEW MOTORIZED VOLUME DAMPER NEW 3/4"CD LINES BALANCE DAMPER AS NOTED. REFER TO DETAIL NEW AHU AND CU AS SHOWN NEW 2"CD UNDERGROUND (a DRAIN WELL TYPE FRENCH WELL (2) 3/4" CD FROM ABOVE EXISTING DUCT. VERIFY SIZE AS SHOWN, OTHERWISE SHALL BE PROVIDED. NOTIFY ENGINEERING FOR ANY DISCREPANCIES BEFORE JOB COMMENCEMENT. F=-U, INW19 no IN] 11:97 ALL MECH. ROOMS SHALL BE IN COMPLIANCE AS PER SECTION 603.1.3. MFBC. MIN. 4" CLEARANCES ALL AROUND THE FAN COIL UNITS. REFRIGERATION PIPING RUNNING MORE THAN 50', COORDINATE SIZE LINES WITH MANUFACTURER RECOMENDATION. IMPORTANT NOTE EXISTING BLDG. WITH NO FIRE SPRINKLES NO FIRE SPRINKLE PLANS ARE REQUIRED I THIS JOB. 12,X 12 f 1 1. EXTAN 1 4 EXTA' DUCTWOR re REM ED. " NEW '11 BE COOR ILDREN) SINK ET RM. BY MECH. " 7 r NEW SINK MEMO EMEN N I NEW �C6 AHU-4 (3.OTN),_ F 1.89 square f .120 =32,5 CHILDREN) II 112 II 6X8 D16X8 /r-3\ 16X8 00 CFM 7' 300 CFM \�:f"OO CFM NI T - AcD etdjr gACDB IVILEAD R CAS} NtVV Z:)Ui I­ I NEW NEW 8X8 AcDbMLeader (ACDB N 1 6XIIO • 4- 4 (A CA 4" - - - - - - - - - - - - - - - - - - - - - - - - - - - - - )/A DRAIN TYPE rF�12X`12 FRENCH WELL E R/A REFER TO DETAIL---2 G U307.8 CFM O/A PAR-121TIAL MECHANICAL �FLOOR PLAN F=-U, INW19 no IN] 11:97 ALL MECH. ROOMS SHALL BE IN COMPLIANCE AS PER SECTION 603.1.3. MFBC. MIN. 4" CLEARANCES ALL AROUND THE FAN COIL UNITS. REFRIGERATION PIPING RUNNING MORE THAN 50', COORDINATE SIZE LINES WITH MANUFACTURER RECOMENDATION. IMPORTANT NOTE EXISTING BLDG. WITH NO FIRE SPRINKLES NO FIRE SPRINKLE PLANS ARE REQUIRED I THIS JOB. 12,X 12 f 1 1. EXTAN 1 4 EXTA' DUCTWOR re REM ED. " NEW '11 BE COOR ILDREN) SINK ET RM. BY MECH. " 7 r NEW SINK MEMO EMEN N I NEW �C6 AHU-4 (3.OTN),_ F 1.89 square f .120 =32,5 CHILDREN) II 112 II 6X8 D16X8 /r-3\ 16X8 00 CFM 7' 300 CFM \�:f"OO CFM NI T - AcD etdjr gACDB IVILEAD R CAS} NtVV Z:)Ui I­ I NEW NEW 8X8 AcDbMLeader (ACDB N 1 6XIIO • 4- 4 (A CA 4" - - - - - - - - - - - - - - - - - - - - - - - - - - - - - )/A DRAIN TYPE rF�12X`12 FRENCH WELL E R/A REFER TO DETAIL---2 G U307.8 CFM O/A PAR-121TIAL MECHANICAL �FLOOR PLAN 99 SCALE: 11/4"=V-0" IVA PON, :711 v w _ I�j KEY P�Ai�L SCALE: N.T.S gj z z 0 ZVOWOp 2. -1 1 LLJ C-Mm S M IL �:" WQR-! z <00 OHM, w§E-;0-F_ aw-�2�6 0 <z LL. 02!wsmw woozaw � , 0 0 C.) > > <z � L2 , w ZXW CO W — w (n w , F,3 SO -02 1 aw �@, �D 6 TO 0> >XUJ Z IL F3 ,ttS23w� ow to ZF_W-2.08 256-<.8 �0 0 0 D IL 0 -, -) w w wz Z "L ,zoww.s 1", z < M 20 Q IL W 2 fo a- z g W. 0 ctz, 2(n gu Uj w 0 8z � OW M '-698>g In 13.83z2owzaZz:� Mo 108�<§g < Uj _>j E � 6'. ., LL g x '6� DZWZZOQCL z �Sn 00 mNou<_F-225-w� WHWMIM�wg g T 2w 8 '. - ogp�W86055z>-, womww - W< jEQMwz0_jwzw C* 0 * 111 _j co 0 T moL I.- j >_ !9 w onxm <Ca�: <LL.(L3:wLL2w< PROPOSED DAYCARE AT EXIST. COMMERCIAL BUILDING SITE ADDRESS: 6333 S.W. 72 ST. MIAMI, FLORIDA 331- - TENANT: TIMEVIEW PRESCHOOL Ph:(786) 274-3668 AGUDELO ARCHITECT P.A. A.A.26002013 Address: 9885 N.W. 51 Terrace Donal, Florida 33178 Phone #: (786) 738-8236 e-mail address: german@agudeloarchitect.net SEAL: STATE OF FLORIDA 14 < GER I EL'6 ARCHITECT FOR THE FIRM LICENSE # AR-0091594 WOW DANI GONZALEZ, P.E. OB. NO.: 110205 LICENSE No. 67574 11537 S.W. 64 ST. UNIT A. MIAMI, FL. 33173 FAX(305) 630-2643, TEL:(305) 794-5813 e-mail: dani.gonzalezC@attnet M OF