11-481-019+S' -1' A.F.F. SEE ARCH. DWGS. (TYP.) EXISTING ROOF STRUCTURE TO REMAIN (SHORE UNTIL AFTER NEW STL. BEAM IS INSTALLED) NU -VUE NVRT -24 ANCHOR STRAP FULLY WELDED TO STEEL TUBE (2 STRAPS PER WOOD MEMBER) d NAILED TO WD. W/ MIN. 1-16d NAILS PER STRAP (TYPICAL). ii 1/4 GOVT. T.R. 3■ x6 e x14 ■ • _ EXISTING ROOF STRUCTURE m TO REMAIN (SHORE UNTIL AFTER —� NEW STL. BEAM IS INSTALLED) 4'x6'x51a "xO' -4' STL. ANGLE (L.L.V.) ANCHORED TO EXIST. CONC. W/ 1 -3/4'0 HILTI HAS SUPER ROD ANCHOR (MIN. EMBED. IN SOLID CONC. = 65ie') EXISTING 8' C.M.U. / T.B. TO BE REMOVED (SHORE EXISTING ROOF STRUCTURE) EXISTING CMU TO REMAIN (TYPICAL) 4' ----- (t STL. ANGLE AND TUBE BM. G.C. TO VERIFY ALL EXISTING DIMENSIONS AND FIELD CONDITIONS. 2 SECTION S.2 SCALE -0' REMOVE EXISTING 8' CMU E TIE BEAM INSTALL NEW STEEL SUPPORT STRUCTURE (SEE SECTION FOR ADDITIONAL INFORMATION) NEW T.R. 3"x6 "x'14' �I I� II II II I) CC1 I I Ca 4,1 1�4 x III II z �I IN (I I� �I I� EXISTING CMU TO REMAIN (TYPICAL) DIMENSIONS SHALL BE FIELD VERIFIED WORK ARFA NO. 5 SCALE: 1/4' = 1' -0' z Q �O > co 0 z4 u- C 111 s U O �U z CD X w _J ALL WORK SHALL COMPLY WITH THE FLORIDA BUILDING CODE 2001, THE AMERICAN CONCRETE INSTITUTE AND ALL OTHER APPLICABLE CODES AND REGULATIONS. ALL MANUFACTURERS OF REINFORCING AND STRUCTURAL STEEL, PRECAST CPREST,-4�E&.`"iED) -c r)mcR1 =T-1 =, AND PREFABRICATED WOOD TRUSSES SHALL SUBMIT SHOP DRAWINGS TO ENGINEER FOR APPROVAL BEFORE FABRICATION. DIMENSIONS AND LENGTHS OF FABRICATED UNITS SHOWN ON SHOP DRAWINGS ARE THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND ARE TO BE VERIFIED BASED ON ACTUAL FIELD CONDITIONS. IN THE CASE OF REINFORCING BARS, STRICT ADHERENCE TO THE BAR PLACING DIAGRAMS /LENGTHS SHOWN ON THE STRUCTURAL DRAWINGS MUST BE FOLLOWED UNLESS OTHERWISE SHOWN BY THE ENGINEER ON SUCH PLANS. GENERAL CONTRACTOR OR ARCHITECT MUST MAKE ANY REVISIONS OR CORRECTIONS, IF ANY, ON SHOP DRAWINGS BEFORE SUBMITTING TO THE ENGINEER FOR FINAL APPROVAL. ALL CONCRETE SHALL DEVELOP THE FOLLOWING MINIMUM 28 -DAY COMPRESSIVE STRENGTHS UNLESS OTHERWISE SHOWN ON THE STRUCTURAL PLANS: PRECAST_ -- ......._- ..5,000 PSI ALL OTHERS.. -. ...._......_......- - .3,000 PSI SLUMP OF CONCRETE SHALL NOT EXCEED 5 INCHES (U.N.O.). A MINIMUM OF 5 CONCRETE SPECIMENS SHALL BE OBTAINED FROM EACH 50 CUBIC YARDS OR FRACTION THEREOF AND SHALL BE TESTED ACCORDING TO A.S.TM. C -39. USE REGULAR WEIGHT (145 PCF) FOR ALL STRUCTURAL MEMBERS. SIGNED AND SEALED COPIES WITH THE RESULTS OF SUCH TESTS SHALL BE DELIVERED TO THE ENGINEER FOR REVIEW. ALL ADMIXTURES SHALL BE APPROVED BY THE ENGINEER REINFORCING STEEL SHALL BE CLEAN, DEFORMED BARS OF NEW BILLET STEEL, FREE FROM OIL, SCALE AND RUST, AND CONFORMING WITH A.S.TM. A -615 GRADE 60. WELDED WIRE FABRIC SHALL COMPLY WITH A.S.TM. A -185. ALL REINFORCING SHALL HAVE THE FOLLOWING MINIMUM CONCRETE COVERAGES: FOOTINGS.,.. ' SLABS POURED ON GROUND---I-1/2' 1 -1/2' STRUCTURAL SLAB POURED ON GROUND...... _.. -.3' GRADE 5EAMS-.,_.,_..3' BEAMS AND COLUMNS 1 -1/2" SUSPENDED STRUCTURAL EXTERIOR CANTILEVER SLA55-.1' STRUCTURAL STEEL SHALL BE NEW CONFORMING WITH A.S.TM. A -36. WELDING ELECTRODES SHALL BE TYPE E -IOXX. STRUCTURAL STEEL COLUMNS SHALL COMPLY WITH A.S.TM. A -500 OR A.S.TM. A -501. ALL STEEL COLUMNS SHALL BE FILLED WITH 3,000 PSI PEAROCK CONCRETE. STRUCTURAL STEEL BOLTS SHALL CONFORM WITH A.S.TM. A -325. EPDXY FOR SETTING REINFORCING STEEL DOWELS INTO NEW OR EXISTING CONCRETE OR MASONRY SHALL BE NIT -HY 150 MAX AS FURNISHED BY HILTI. INSTALLATION SHALL BE AS PER MANUFACTURER'S INDICATIONS. ALL STRUCTURAL LUMBER SHALL BE SOUTHERN PINE (NO. 2 OR BETTER) WITH THE FOLLOWING MINIMUM STRENGTHS: BENDING_....._... 1,500 PSI TENSION PARALLEL TO GRAIN 25 PSI SHEAR PARALLEL TO GRAIN _._ ............._.........90 PSI COMPRESSION PERPEND. TO GRAIN_ _ _ .. 565 PSI COMPRESSION PARALLEL TO GRAIN..._.... -1650 PSI ELASTIC MODULUS 1000,000 PSI ALL SLABS ON GRADE SHALL BE POURED OVER A .006 IN. VISQUEEN MEMBRANE ON CLEAN, WELL COMPACTED INORGANIC FILL. COMPACTED SOIL SHALL ATTAIN A MINIMUM OF 95 % OF MAXIMUM DENSITY FOR ALL LAYERS, AND VERIFIED BY FIELD DENSITY TESTS AS PER ASTM -D -1551. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE BRACING AND SHORING FOR ALL STRUCTURAL MEMBERS, WALLS AND NON - STRUCTURAL MEMBERS DURING THE COURSE OF CONSTRUCTION. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE DIMENSIONS. GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND ACTUAL CONDITIONS EXISTING AT THE FIELD_ IF UNUSUAL OR UNFORESEEN CONDITIONS ARE ENCOUNTERED NOTIFY ENGINEER BEFORE PROCEEDING WITH THE WORK. SEE ARCH. DWGS. (TYP.) �t OF MACH. BOLTS. -- UNDERSIDE OF CONC. BM. EXISTING ROOF STRUCTURE (TO REMAIN) d STEEL CHANNELS. 3i4'4 ASTM -A -30-1 MACHINE BOLTS g 24' O.C. WITH NUT d WASHERS. EXISTING GONG. TIE BEAM TO REMAIN (FIRST BOLT TO BE PLACED 2' MAX. FROM CHANNEL ENDS - REMAINING (SHORE AS REQUIRED UNTIL STEEL TO BE SPACED 24' O.C. THEREAFTER) CHANNELS HAVE BEEN INSTALLED) C8x115 STEEL CHANNEL ON EA. SIDE OF EXISTING TIE BEAM AS SHOWN NOTE: ENGINEER SHALL BE EXISTING 8' C.M.U. TO BE REMOVED GALLED TO INSPECT THE (SHORE EXISTING GONG. TIE BEAM) COMPLETED CHANNEL INSTALLATION BEFORE REMOVAL OF SHORES. CITY OF SOUTH I° A BUILDING Epp STePt:r�ff .,._ G.C. TO VERIFY ALL EXISTING DIMENSIONS AND FIELD CONDITIONS. � 't,, � ('I SECTION S-2 O 0 Z F !w- Z W aZ ZZI- O W- O g O W W h w `w0aw omE - °Z= zz x w -vOF- Woo &z' zo' =o °o . W z< 0 0 W% 3 z' a .. =OZ oo WW�¢wa oC7OZO�- W aay'�>' am =0ma aOZw�W w9"-ZaW O ®c�i�w aQZ�wix zx�QQO =ymom� zom °oa :�YqT -02 <EOxyx xwwF g- n u 0 >x 0 0 i W co _-,J Jw Z =0: �D o 2id;a 000 - cncnvW= zQ >zm.w gwMooaw >mozQZ 2 wlo- =w w 0 0 z Z a W to M -k_�- u> W m g 3i W O Z 2 o w Z 0 Z? �O >K- zwOi;Qa §O �Qaa0 :P:D poa zow 'ogaa a 2oO°w NZd VFO1Z(n7nw0M w3:wWZO.owzW�xo Q O M w w O O Z O O W} co W W'nOFx -ZO'n W Lu mcoz oxw a �� JaF -�Sx �> w ~��w =UOm00 ¢m��4wa�rnw�cna C 0 .u) 0 w Ii PROPOSED DAYCARE AT EXIST. COMMERCIAL BUILDING SITE ADDRESS: 6333 S.W. 72 ST. MIAMI, FLORIDA 331 -- TENANT: TIMEVIEW PRESCHOOL Ph:(786) 274 -3668 AGUDELO ARCHITECT P.A. A. A.26002013 9885 N.W. 51 Terrace Doral, Florida 33178 me #: (786) 738 -8236 mail address: Tnan0caudeloarchitect.ne SEAL: STATE OF FLORIDA GERMAN A. AGUDELO ARCHITECT FOR THE FIRM LICENSE # AR- 0091594 s - 4 .. .4 I ORENZO SOTO F'.E_ ENGINEER 3 S:I.U. 100TH GOURT H .® :.g� Ww... MIAMI, EL 33165 ' EL/1 =�4X (305) 22QJ - (o ro 92