13-386-004s.
GALV. METAL DRIP ON
P.T. CONT. NAILE
TOP OF TIE BEAM
Rio
1: I
—4 TOP • FINISH FLOOR
EL + 0'-0"
TIE BEAM NOTE:
F.B •4 B • •
C 27.2 THE TIE BEAM SHALL E CNTINUOUS. CNTINUITY
OF *f�E REINFAUVIN. 5TRAIGHT RUNS SHALL BE PROVIDED BY LAPPING
SPLICES NOT LESS THAN .18 INCHES. CONTINUITY SHALL BE PROVIDED AT
CORNERS BY BENDING TWO BARS FROM EACH DIRECTION AROUND THE CORNER
• INCHES OR BY ADDING TWO #5 BENT BARS WHICH EXTEND 30 INCHES
EACH WAY FROM THE CORNER. CONTINUITY AT COLUMNS SHALL BE PROVIDED
BY CONTINUING HORIZONTAL REINFORCING THROUGH COLUMNS OR BY BENDING
HORIZONTAL REINFORCING IN THE COLUMNS A DISTANCE OF 18 INCHES.
CONT. FIRESTOP
3/4- CAVITY INSULATION
—(TYP. 0 ALL EXTERIOR WALLS�
5/8" GYP. BRD. ON
—WD. FURRING 0 16 O.C.
P.T. CONT. NAILER (TYP.)
BASEBOARD
(SEE FINISH SCHEDULE)
EXISTING 4* CONC. FLOOI3T-&-AR—,
1110MV'SCALE 3/4"= 1 '-06
TERMITE PROTECTION:
ALL BUILDING SHALL HAVE PRECONSTRUCTION TREATMENT
PROTECT10N AGAINST SUBTERRANEAN TERMITES.
THE RULES AND LAWS AS ESTABLISHED BY THE FLORIDA
DEPARTMENT • AGRICULTURE AND CONSUMER SERVICES SHALL
5114iliv Q W-1 No"' jai 0 •
20-
10111
cy
-- t-
SECOND MEANS OF SCAPE WINDOWS
EGRESS WINDOW AS SECOND MEANS OF ESCAPE TO
HAVE AN OUTSIDE WINDOW OR DOOR OPERABLE FROM
THE INSIDE WITHOUT THE USE OF TOOLS AND PROVIDING
A CLEAR OPENING OF NOT LESS THAN 20 IN. IN WIDTH,
241N. IN HEIGHT AND 5.7 SQFT. IN AREA.
2 NOT USED 3 EGRESS WINDOW
N.T.S. N.T.S.
CEILING
CEILING
(SEE FINISH
SCHEDULE, TYP.) 2 X 6 WD. BACKING
3 5/8' 20 GA.
METAL RUNNER, FOR CAB. BACKIING WAl L cAq\lNE r
(TYPICAL)
IM* G.W.B. ON 2 X 6 WD. BACKING
3 SW 20 GA METAL AT BOT. OF WALL
STUDS Ca 16* O.C. CABINET AND AT WALL
ON BOTH SIDES, (TYP.) HUNG PLUMBING FIXTURES
(GREEN BOARD AT COUNTERTOP
WET AREAS) I
INTERIOR PARTITION
3)- METAL STUDS AT
A 24' C. C.
CERAMIC 71LE
ON CBU. WHERE
OCCURS -((SEE
FINISH SCHED.)
3 W 20 GA-
SEALANT METAL RUNNER, (2) A MINIMUM 2"X 4' HORIZONTAL WOOD
BOTH SIDES. (TYPICAL) MEMBER, SECURELY FASTENED TO NOT LESS
THAN 2 SUCH STUDS, SHALL BE INSTALLED FOR
THE ATTACHMENT OF EACH WALL HUNG
PLUMBING FIXTURE AND WALL CABINET
4 NONRATED PARTITION 5 WOOD BACKING DETAIL
N.T.S. N.T.S.
5/8* SMOOTH STUCCO
............ . ... .......... jr EXT. FINISH 3/4' WD. NAILER
JA. 2x6 P.T. WOOD DRYWALL ON WD. MOLDING
(CUT TO 4-1,2-) FURRING (SEE TYPICAL
Wi3-12X 1/4*- TAPCONS SECTION]
AT 4* OF EDGES & IN THE SEC
MIDDLE (MAX. DIST. V-4- O.C.)
INTERIOR
RYWALL ON WD.
FURRING (SEE TYPICAL CONC. COL OR CMU DOOR FRAME
SECTION) SEE STRUCTURAL DRAWINGS
•
BURGLARY INTRUSION NOTES,'
1. ALL SINGLE E XTERI•• SWING DOORS SHALL HAVE A LOCK TO BE_
KEY OPERATED FROM THE EXTERIOR WITH A MIN-,MUM OF 6,000-
POSSIBLE KEY CHANGES OR LOCKING COM;3INATlONSlF KEY-i'N-
THE KNOB LOCK IS USED THERE SHALL BE AN AU-kLIARY S.NGLr--
DEAD BOLT WITH HARDENED BOLT INSERTS.
2. THE AC11VE LEAF OF PAIRS • EXTERIOR SWING DOORS SHALL
HAVE SAME LOCKS AS REQUIRED FOR SINGLE EXTERIOR SWING
DOOR. THE INACTIVE LEAF OF THESE PAIR • DOORS SHALL
HAVE MULTIPLE POINT LOCKS WITH 51W MIN. THROW BOLTS
WITH INSERTS.
3. SLIDING GLASS DOORS SHALL BE PROVIDED WITH SLIDING DOOR
DEAD BOLTS OR A BOLT OR PIN NOT REMOVABLE OR OPERABLE
FOR EXTERIOR, AT THE JAMB, HEAD, SILL OR AT MEETING
MULLIONS. THESE DOORS SHALL BE REINFORCED IN THE STRIKE
AND LOCK ARE TO MAINTAIN BOLT STRENGTH EFFECTIVENESS, IF
NECESSARY, AND SUCH DOORS SHALL HAVE NO SCREWS REMOVABLE
FROM THE OUTSIDE WHICH WOULD FACILITATE READY ENTRY FROM
OUTSIDE.
4. OVERHEAD DOORS SHALL BE PROVIDED WITH MULTIPLE POINT
LOCKS OR BE LOCKED AT MORE THAN ONE POINT WITH HARDENED
BOLT OR BOLTS WITH INSERTS ENGAGING AT LEAST TWO OPPOSITE
POINTS OTHER LOCKING DEVICES SHALL NOT BE
REQUIRED WHERE SUCH DOORS ARE CONTROLLED AND LOCKED
BY ELECTRIC POWER.
5. HINGES ON EXTERIOR OUT SWINGING DOORS SHALL HAVE NON
REMOVABLE PINS.
6. JAMS
• ALL EXTERIOR OFFSET TYPE IN SWING DOORS BE
RABBETED, OR OF SIMILAR FABRICA-TION, TO PREVENT
DEFEATING THE PURPOSE OF THE STRIKE AND THE INTEGRITY OF
LOCKS AND LATCHES.
7. SINGLE SWINGING EXTERIOR DOOR IF WOOD, SHALL BE SOLID
CORE OF NOT LESS THAN 1 1 M"THICK
8. GLASS AND EXTERIOR DOORS SHALL COMPLY WITH THE AMERICAN
NATIONAL STANDARDS INSTITUrES-STAND••D 297.1.
9. VISION PANELS IN EXTERIOR DOORS OTHER THAN GLAZING
WITHIN 40"OF THE INSIDE LOCKING ACTIVATING DEVICE •
LOOSE AND SWINGING DOORS SHALL COMPLY WITH AMERICAN
NATIONAL STANDARDS INSTITUTES-STANDARD 297.1.
10. SLIDING GLASS DOORS AND WINDOWS SHALL BE INSTALLED AND
CONSTRUCTED SO THAT NO PANEL CAN BE LIFTED FROM THE
TRACKS WHEN IN THE LOCKED POSMON AND SO AS TO COMPLY
WITH THE ARCHITECTURAL ALUMINUM MANUFACTURERS
ASSOCIXTION STANDARDS FOR FORCED ENTRY RESISTANCE, AAMA
1303.3.
11. VENTS ON OVERHEAD GARAGE TYPE DOORS SHALL NOT BE
INSTALLED CLOSER THAN 40* TO THE INSIDE LOCK ACTlVAnNG
DEVICE.
12. SINGLE SWING EXTERIOR AND SWING DOORS CONNECTING LPONG
AREAS WITH GARAGE AREA SHALL BE A MIN. 13/8- THICK,
SOLID CORE, AND SHALL BE SECURED WITH A LATCH AND SINGLE
DEAD BOLT SETS WITH LATCH THROW MIN. OF 112' AND BOLTS
HAVING A MIN.
• I * THROW.
13. FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH A DOOR
SCOPE OR VISION PANEL
14. ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF
RESIST'ING A FORCE • 300 LBS. APPLIED IN ANY MOVABLE
DIRECTION AND IN ACCORDANCE WITH RESISTANCE STANDARDS
SET FORTH IN METRO C•DE/ FLORIDA BUILDING CODE-
C'ty Of SOuth Aliami
Building Dept.
6730 Sunset Drive
South Aliami, FL 33743
13
11
a m
Ir
0
U.
w
:D
Z
o
jjj- Ln
Lf)
0
z
V-
W cr)
a:
U)
cm
0
0
U)
tv)
<
cl)
cr)
cr-
0
z
. . . CONC. TB SEE STRUCTURAL
. . . . . . . . . . .
DRAWINGS
2 X P.T. WOOD
W)3-r x 1/4' TAPCONS
3/4' DRIP MOLDING
0 BOTTOM AT 8'O.C.
METAL DOOR
WOOD DOOR
EXTERIOR INTERIOR
W/ BACKER ROD
SMOOTH STUCCO CONT, SEALANT
EXT. FINISH
NOTE: FOR SLIDING GLASS DOORS
EXTERIOR
JAMB AND HEADER USE 1X4 P.T. WD.
ATTACHED W/ 1-12 TAPCONS
(LD 16- O.C. (ryp.)
DOOR HEAD DETAIL
DOOR BUCK DETAIL
5
6
N.T.S.
N.T.S.
SCHEDULE
#10 FHPH SMS 6' WINDOWS
SCHEDULED INSULATION
FROM ENDS 24"O.C. MAX INTERIOR
'A
1-1/4" EMBEDMENT MIN. EXTERIOR
5V DRYWALL ON WD.
SEALANT
FURRING (SEE TYPICAL
PRECAST CONCRETE
SE
SILL
CONIC. LINTEL
SLOPE
STUCCO
W BEVELED P.T. WOOD
'A % FINISH
12" DRYWALL ON WD.
W)3-112* X 1/4"- TAPCONS
b 8. O.C. (TYP.)
FURRING (SEE TYPICAL 4 4
#10 FHPH SMS 6'
SECTION) • A
FROM ENDS 24'O.C.
1 -1/4* EMBEDMENT MIN. MAX _
Er C.B.S.
1/4' SPACING MAX
SCHEDULED INSULATION
FINISH
INTERIOR SCHEDULE
WINDOWS
EXTERIOR
WINDOWS HEADER/JAMB
WINDOW SILL
7
8
ANCHOR DETAIL. N.T.S.
N.T.s. ANCHOR DETAIL
BURGLARY INTRUSION NOTES,'
1. ALL SINGLE E XTERI•• SWING DOORS SHALL HAVE A LOCK TO BE_
KEY OPERATED FROM THE EXTERIOR WITH A MIN-,MUM OF 6,000-
POSSIBLE KEY CHANGES OR LOCKING COM;3INATlONSlF KEY-i'N-
THE KNOB LOCK IS USED THERE SHALL BE AN AU-kLIARY S.NGLr--
DEAD BOLT WITH HARDENED BOLT INSERTS.
2. THE AC11VE LEAF OF PAIRS • EXTERIOR SWING DOORS SHALL
HAVE SAME LOCKS AS REQUIRED FOR SINGLE EXTERIOR SWING
DOOR. THE INACTIVE LEAF OF THESE PAIR • DOORS SHALL
HAVE MULTIPLE POINT LOCKS WITH 51W MIN. THROW BOLTS
WITH INSERTS.
3. SLIDING GLASS DOORS SHALL BE PROVIDED WITH SLIDING DOOR
DEAD BOLTS OR A BOLT OR PIN NOT REMOVABLE OR OPERABLE
FOR EXTERIOR, AT THE JAMB, HEAD, SILL OR AT MEETING
MULLIONS. THESE DOORS SHALL BE REINFORCED IN THE STRIKE
AND LOCK ARE TO MAINTAIN BOLT STRENGTH EFFECTIVENESS, IF
NECESSARY, AND SUCH DOORS SHALL HAVE NO SCREWS REMOVABLE
FROM THE OUTSIDE WHICH WOULD FACILITATE READY ENTRY FROM
OUTSIDE.
4. OVERHEAD DOORS SHALL BE PROVIDED WITH MULTIPLE POINT
LOCKS OR BE LOCKED AT MORE THAN ONE POINT WITH HARDENED
BOLT OR BOLTS WITH INSERTS ENGAGING AT LEAST TWO OPPOSITE
POINTS OTHER LOCKING DEVICES SHALL NOT BE
REQUIRED WHERE SUCH DOORS ARE CONTROLLED AND LOCKED
BY ELECTRIC POWER.
5. HINGES ON EXTERIOR OUT SWINGING DOORS SHALL HAVE NON
REMOVABLE PINS.
6. JAMS
• ALL EXTERIOR OFFSET TYPE IN SWING DOORS BE
RABBETED, OR OF SIMILAR FABRICA-TION, TO PREVENT
DEFEATING THE PURPOSE OF THE STRIKE AND THE INTEGRITY OF
LOCKS AND LATCHES.
7. SINGLE SWINGING EXTERIOR DOOR IF WOOD, SHALL BE SOLID
CORE OF NOT LESS THAN 1 1 M"THICK
8. GLASS AND EXTERIOR DOORS SHALL COMPLY WITH THE AMERICAN
NATIONAL STANDARDS INSTITUrES-STAND••D 297.1.
9. VISION PANELS IN EXTERIOR DOORS OTHER THAN GLAZING
WITHIN 40"OF THE INSIDE LOCKING ACTIVATING DEVICE •
LOOSE AND SWINGING DOORS SHALL COMPLY WITH AMERICAN
NATIONAL STANDARDS INSTITUTES-STANDARD 297.1.
10. SLIDING GLASS DOORS AND WINDOWS SHALL BE INSTALLED AND
CONSTRUCTED SO THAT NO PANEL CAN BE LIFTED FROM THE
TRACKS WHEN IN THE LOCKED POSMON AND SO AS TO COMPLY
WITH THE ARCHITECTURAL ALUMINUM MANUFACTURERS
ASSOCIXTION STANDARDS FOR FORCED ENTRY RESISTANCE, AAMA
1303.3.
11. VENTS ON OVERHEAD GARAGE TYPE DOORS SHALL NOT BE
INSTALLED CLOSER THAN 40* TO THE INSIDE LOCK ACTlVAnNG
DEVICE.
12. SINGLE SWING EXTERIOR AND SWING DOORS CONNECTING LPONG
AREAS WITH GARAGE AREA SHALL BE A MIN. 13/8- THICK,
SOLID CORE, AND SHALL BE SECURED WITH A LATCH AND SINGLE
DEAD BOLT SETS WITH LATCH THROW MIN. OF 112' AND BOLTS
HAVING A MIN.
• I * THROW.
13. FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH A DOOR
SCOPE OR VISION PANEL
14. ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF
RESIST'ING A FORCE • 300 LBS. APPLIED IN ANY MOVABLE
DIRECTION AND IN ACCORDANCE WITH RESISTANCE STANDARDS
SET FORTH IN METRO C•DE/ FLORIDA BUILDING CODE-
C'ty Of SOuth Aliami
Building Dept.
6730 Sunset Drive
South Aliami, FL 33743
13
11
�Tl I
a m
Ir
0
U.
w
:D
Z
o
jjj- Ln
Lf)
0
z
V-
W cr)
a:
U)
cm
0
0
U)
tv)
<
cl)
cr)
cr-
0
z
�Tl I