12-836-002I DAMAGE DEMOLITION PLAN SCALE: 11/4"=V-011 LEGEND EXISTING TO BE DEMOLISHED EXISTING TO REMAIN GENERAL DEMOLITION NOTES: I. THE CONTRACTOR SHALL FIELD VERIFY ALL EXIST =[NG-- CONDITIONS AFFECTING THE PRELIMINARY DEMOLITION;- - -- - WHETHER SHOWN OR NOT SHOWN, ITEMS MAY HAVE TO BE RELOCATED AND /OR TEMPORARILY SUSPENDED, SUPPORTED, OR REMOVED AS REQUIRED FOR PURPOSES OF DESIGN DISCOVERY. THE SECONDARY AND FINAL DEMOLITION PHASE IS TO BE INITIATED UPON COMPLETION OF ALL DESIGN DOCUMENTS AND FINALIZATION OF THE DESIGN INTENT. 2. PRELIMINARY DEMOLITION DOES NOT IMPACT MECHANICAL, HVAC, PLUMBING, AND FIRE PROTECTION SYSTEMS. THE REMOVAL AND RELOCATION OF ABOVE STATED ITEMS IS PENDING FINALIZATION OF THE DESIGN INTENT. BATH ROOM AND PLUMBING FIXTURES ARE TO BE LEFT IN THEIR EXACT LOCATIONS. 3. GENERAL CONTRACTOR SHALL COORDINATE PRELIMINARY DEMOLITION OPERATIONS WITH ALL OTHER REQUIRED SUB - CONTRACTORS AND RESPECTIVE TRADES WHERE APPLICABLE. ALL DEMOLITION WORK SHALL BE CONDUCTED UNDER CONTROLLED CONDITIONS. 4. REMOVE FIXTURES AND ELECTRICAL DEVICES AS INDICATED ON PLAN. PRELIMINARY DEMOLITION PLAN ONLY REFLECTS IMPACTED OUTLETS AND SWITCHES. FIXTURES ARE NOT CURRENTLY INSTALLED. 5. COORDINATE ANY SHUTDOWN OF EXISTING SERVICES AND EQUIPMENT REMAINING IN USE WITH OWNERS' REPRESENTATIVE. PROVIDE ADEQUATE NOTICE AND MAKE PROVISIONS TO MINIMIZE IMPACT TO ANY NEIGHBORING UNITS OR TENANTS. 6. REMOVE ALL CONDUIT AND WIRE BACK TO NEAREST UPSTREAM DEVICE REMAINING IN SERVICE. WHERE DEMOLITION WORK AFFECTS ELECTRICAL SERVICE TO DOWNSTREAM DEVICES TO REMAIN; EXTEND CONDUIT AND WIRE AS REQUIRED TO MAINTAIN ELECTRICAL SERVICE. 7. DISPOSE OF ALL MATERIALS OFF SITE, ALL MATERIALS SHALL BE DISPOSED OF IN ACCORDANCE WITH ALL FEDERAL STATE AND LOCAL REGULATIONS. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE REMOVAL AND DISCARD�KUTH OF ALL DEMOLITION WASTE INCLUDING ANY UNFORESEEI"I`D' "GDEp . ,UCTURAL sEC71 ITEMS WITHIN THE SCOPE OF THE PROJECT. :_7) gv 8. CARE SHOULD BE EXERCISED DURING DEMOLITION TO!,_ HAVE THE LEAST IMPACT ON THE CONDUIT OF EXISTING DEVICES. WHERE FEASIBLE EXISTING CONDUIT SHOULD BE LEFT INTACT AND TEMPORARILY SUPPORTED UNTIL THE DESIGN INTENT CAN ESTABLISH THE DESIRED RELOCATION AND /OR REMOVAL. SERVICE IN SUCH CASES NEEDS TO BE I NTERRJPTED. 9. CARE SHOULD BE EXERCISED TO PROTECT ALL EXISTING FINISHED SURFACES AND APPLIANCES DURING DEMOLITION. THE CONTRACTOR IS EXPECTED TO PROTECT FROM DUST,.AND DEBRIS ALL EXISTING APPLIANCES THROUGHOUT THE�PW INCLUSIVE OF BATHROOM FIXTURES, PLUMBING FIX ,\.001�•`�••`'•. CABINETRY, KITCHEN APPLIANCES, ETC.,'' ° - REVISIOt4S NQ _ DATE •o ti O� r- Z Lo —moo coo) :w� o U W c� m cce M Q E U) U) Lu o � v o ��� <z WL.Lti U U m� ��o0 tiz- �zNC,4 Uw~ ) a)EE (� N r- J z �o Oi= �M Q F. 0 w JU zz Z O O U o- 7 Q W ry M� J H M 'd' C%) M }, M cn J r LL_ (.0 Q v J 0 DESIGNED = r G.E. CN w co O 7 Q W ry M� J H DRAWING N0. D -1 SHEET 1 OF 1 DATE 07 -25 -12 SCALE AS SHOWN 0 DESIGNED Y G.E. w v DRAWN S. G. DRAWING N0. D -1 SHEET 1 OF 1