11-532-022PLUMBING NOTES
1.0 GENERAL
1.1 PROVIDE (FURNISH AND INSTALL) ALL NECESSARY
MATERIALS AND LABOR FOR A COMPLETELY OPERATIONAL
PLUMBING SYSTEM AS SHOWN ON THE DRAWINGS AND
HEREIN SPECIFIED INSTALL IN ACCORDANCE WITH HE
FLORIDA BUILDING CODE AND LOCAL ORDINANCES
1.2 SCOPE OF WORK:
PROVIDE THE FOLLOWING COMPLETE SYSTEMS:
a. SANITARY COLLECTION.
b. DOMESTIC COLD AND HOT WATER.
1.3 PAY FOR ALL FEES,INSPECTIONS AND CONNECTION
CHARGES REQUIRED.
1.4 VERIFY AT JOB SITE ALL SPACE CONDITIONS,DIMENSIONS
WITH PIPE,FIXTURES, AND EQUIPMENT SIZES PRIOR TO
FABRICATION OR INSTALLATION,COORDINATE REQUIREMENTS
TO AVOID INTERFERENCE WITH OTHER TRADES.
1.5 SUBMIT SHOP DRAWINGS FOR ARCHITECT/ENGINEER
APPROVAL BEFORE PROCEEDING WITH THE PURCHASE OR
INSTALLATION OF EQUIPMENT AND MATERIALS.
1.6 GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS
AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM
DATE OF ACCEPTENCE.
2.0 MATERIALS
2.1 PROVIDE SHUT -OFF VALVES FOR EACH FIXTURE AND AIR
CHAMBERS WHERE SHOWN AND WHERE REQUIRED FOR
PROPER PERFORMAMCE OF THE SYSTEM.
2.2 PROVIDE DIELECTRIC FITTINGS TO CONNECT PIPING TO
EQUIPMENT OF DISSIMILAR METALS,USE CLAMPS AND
FASTENERS OF SIMILAR METALS OR ISOLATE THEM FROM
PIPING AND SLABS TO PREVENT CORROSION.
2.3 PIPING
2.3.1 DOMESTIC COLD AND HOT WATER: COPPER TUBING TYPE
"K" OR "L" WITH SOLDER JOINTS,WOG BRONZE VALVES
125 P.S.I. MIN. PROVIDE PRE - MOLDED FIBERGLASS INSULATION
FOR HOT WATER LINES.
2.3.2 SANITERY WASTE AND VENT: CAST IRON PIPING UNDER
SLABS,CAST IRON NO -HUB OR COPPER D.W.V. ABOVE TO
P.V.C. DRAIN PIPE AND FITTINGS MAY BE USED WHEN
ALLOWED BY THE LOCAL JURISDICTION.
2.3.4 ALL OUTDOORS FLOOR CLEAN OUTS SHALL BE TERMINATED
UP TO GRADE AND SHALL BE MARKED (EXISTING)
,&Tri'TI : C -
1. ANTI - SCALED VALVES FOR TUB /SHOWER REQUIRED
2. VACUUM BREAKER VALVE FOR BIDET REQUIRED
3. PROVIDE SHUT OFF VALVES FOR EACH FIXTURE AND
WATER HAMMER ARRESTORS AT QUICK CLOSING VALVES
4. MINIMUN SIZE OF ALL PLUMBING DRAIN LINE
BELOW FLOOR 2"
5. ALL WATER PIPING LINES THROUGH ATTIC.
6. ALL FIXTURE AND FAUCETS SHALL COMPLY WITH THE
FLORIDA BUILDING CODE WATER CONSERVATION STANDARDS.
7. ALL DRAIN PIPING UNDER SLAB SHALL BE 2" MIN
2" & LESS 0 DRAIN @ 1/4" DROP
3" & 4" 0 DRAIN @ 1/8" DROP
8. PROVIDE SHOCK ARRESTOR EACH CLOTHES
WASHER & DISHWASHER.
PLUMBING SYMBOL LEGEND
SYMBOL
DESCRITION
TRAP
SIZE
BUILDING SANITARY SEWER LINE
H.W.
VENT LINE
COLD WATER LINE
3"
HOT WATER LINE
-
PRESSURE AND TEMP.& RELIEF LINE
SD
STORM DRAIN LINE
--
GATE VALVE
1/2"
CHECK VALVE
PRESSURE AND TEMP & RELIEF VALVE
G)
PIPE UP
V
PIPE DOWN
® BFP
BACK FLOW PREVENTOR
e FCO
FLOOR CLEANOUT
S WCO
WALL CLEANOUT
VB
VACUUM BREAKER
11 VTR
VENT THRU ROOF
0 SA
SHOCK ARRESTOR
n ACH.
AIR CHAMBER
=1 S.W.P.
SLEEVE WALL PARTITION
ASD
ANTI SCALD DEVICE
--C+
HOSE BIBB
TL WH
ELECTRONIC TANKLESS WATER HEATER
PLUMBING FIXTURE SCHEDULE
SYMBOL
FIXTURE TYPE
TRAP
SIZE
C.W.
H.W.
DESCRIPTION
WATER CLOSET
3"
1/2"
-
®
LAVATORY
1 -1/2"
1/2"
1/2"
SHOWER
2"
1/2"
1/2"
W/ ANTI -SCALD VALVES
®
KITCHEN SINK
1 -1/2"
1/2'
1/2"
WASHING MACHI.
2"
1/2"
1/2"
W /SHOCK ARRESTOR
BATH TUB
1 -1/2"
1/2"
1/2"
W/ ANTI -SCALD VALVES
aREFRIGERATOR
N/A
1/2"
N/A
ICE MAKER CONNECTION
DISWASHER
2"
1/2"
1/2"
W /SHOCK ARRESTOR
TANK LESS WATER HEATER
NIAGARA TITAN -SCR2 ELECTRONIC T ANKLESS WATER HEATER
MODEL VOLTAGE ENERGY PIPE FITTING
EFFICIEi--ICY
N-42 4.2KW -220V UP TO 99,5% 1/2" STANDARD PIPE
DIMENSIONS ....... 10" x 7" x 2.75"
NOTE: TITAN - SCR2 REQUIRING NO VENTING.
THE COMPACT SIZE ALLOWS INSTALLATION
ALMOST ANYWHERE.
DOUBLE SE
A
►`
HNG
GALV. DRYER
EXHAUST
ROOF CAP.
BACKDRAFT DAMPER
ROOF TILE
L2" X 4"
BLDG.
4" MTL.DUCT
FROM DRYER EXHAUST
BATHROOM EXHAUST DETAILS
N.T.S.
HING
ICKET
TYPICAL PITCH POCKET FOR VENT.
PIPES & OTHER PENETRATIONS -NTS
r
r -�
4.•
r
F4. N
Architect RubenTravieso
AR 000 8229
2248 SW 57 AV., MIAMI, FL. 33155
786.260.7522 Cell - 786 - 388 -0312 PHN
786.388.0366 FAX
E -MAIL: rubentravieso @bellsouth.net
REVISIONS:
# I DATE: I # I DATE:
I PROJECT: I
REAR ADDITION
AND REMODELING
6321 SW 62nd CT
SOUTH MIAMI, FL
vr
v
I SHEET CONTENT: I
PLUMBING NOTES
ALL IDEAS, DESIGNS, ARRANGEMENTS
AND PLANS INDICATED OR REPRESEN-
TED BY THIS DRAWING ARE OWNED
BY, AND THE PROPERTY ,OF THIS OF-
FICE AND WERE CREATED, EVOLVED
AND DEVELOPED ' FOR USE ON, AND
IN CONNECTION WITH THE SPECIFIED
PROJECT. NONE OF SUCH IDEAS, DE-
SIGNS, ARRANGEMENTS OR PLANS SHALL
BE USED BY OR DISCLOSED TO ANY
PERSON, FIRM OR CORPORATION FOR
ANY PURPOSE WHATSOEVER WITHOUT
THE EXPRESSLY WRITTEN PERMISSION
OF RUBEN TRAVIESO, ARCHITECT.
PROJECT NUMBER:
ISSUED:
DRAWN BY: M.P.
CHECKED BY:
FILENAME:
,
«. a
Y 3 P =3