11-532-019Uk
NEW AC -2.
AC SCHEDULE TRANE A /C -2
SEER
—
16.25
696 N
COND. UNIT
1
L4TTX6024bl 0 OA
2.0 TON
AIR HANDLER
1
4TEE3F37A1000A
Fire Rated R/Ceiling Assembly
HEATER
X1
—
5.0 KW
CFM
1
800
I X1
LATENT B.T.U.
6100
SENSIBLE B.T.U.
18,100
TOTAL B.T.0
24,200
EQUIPMENT B.T.0
TOTAL B.T.0 CALCULATED
p U
O L
I v U)
O
Cn O
U
04—
U � �
v �
> cn
N L N
N
C:
v
7/8 & 3/8
1/2
UIPME INO FLANGE
R&ROUS Goss \
I wXI wXI' CHANNa RBROUS GLASS DUCT
FAM 7 ED TO METAL FLANGE
R&ROUS GLA DUCT 22 GAUGESHEET METAL 22 GAUGESHE�T METAL
SS IWT
NOTE POCKET LOCK 1'9(1'9(1"
SHAT METAL CONECflONS #f 1QKI I14'SHEET METAL
MLIST BEMADE USING GLASS BUMS G D Cf SCRE}WgS�AND 21/?SQCUATRE
FABRIC AND MAS11C (GFMj BEAR/N G PLATE A *CNDI &,% O
EXCEPTION.
GUNPRUCTION PRESSURE QSURE 22 GA. 'l SHEETMETAL SLI�VWM CLOSURE
FLANGE ON SHEET
CLASS LS I'W.G OR LESS AND METAL DUCT CLINCH
SHUT METAL SURFACES ARE CLEANED LOCK OR L>dV�- EMMEM/
CAREH/LLY UL LLSTED PRESSURE SENSMYE
ALUMINUM TAPE MAY BE USED. XMIN
ALL CONNECTION OFRBROUS GLASS EUL PER P T ION 6'MIN. If HEALING EQUIPMENT
TO EQUIPMENT' AND METAL DUCT
MUST BEMECHANICALLYATTACHED
ROOF I SUPPLYAIR DUCT 12'
..................................................... ...............................
TO
lot FLOOR BELOW
I
ATTIC
SPACE.
cEluNo
PROVIDE A MIN. OF 4'
SPACE WHERE MECHANICAL
COMPONENTS TO ASSURE
ADECUATE ACCESS FOR
CONSTRUCTION & CLEANING.
COILmEAT
SECTION
NOTE:
PROVIDE A FLOAT SWITCH IN SECONDARY DRAIN PAN (IF USED),
INTERCONNECTED WIAH STARTISTOP CONTROLS. FLOAT SWITCH IS TO SHUT
DOWN AHU, WHENEVER WATER LEVEL IN DRAIN PAN RAISES TO 112" BELOW THE
RIM OF PAN. FMC - 307.2.3.
PROVIDE MINIMUM 4" AROUND AHU IN MECHANICAL CLOSET PER FBC CHAP.13
610.1.ABC.3.0.3 AND FMC SECT. 603.1.3.
Ref lines
Ins. Thck
ROUND DUCT HANGERS
(typical)
1 -1/2" x 26 gee,
strap hangers at
max.
sheet metal
flexible R —valu
(typical of 2.)
FAN SECTION
FILTERACCESS
Al jahte belwssn as c I, a ofairdam
and otlrorocmponenb ofalrdbkfxAlm
= as r 0 - a offf s ocnponsrksalWbs
SOW" Sw c. "rsg *wnana
REF. LINES
PROVIDE CAP OFF
WITH 1M' PERFORATED
FOR VENT
12'MIN.
`DRAIN PAN WANET DETECTOR
�► TO CONTROL OVERFLOW BY
SHUTTTNO LONW THE UNIT
WHENACTIVATED.
PREFAB MM FRAME
F.F.
A/C CLOSET INSTALLATION
N T.S.
HVAC DESIGN REQUIRES: I YES
a
Duct Smoke Detector
n
Fire Dam er s
696 N
X1
Smoke Dam er s
AMPS
X 1
Fire Rated Enclosure
1/240
X1
Fire Rated R/Ceiling Assembly
X1
Fire Stopping
X
Smoke Control
I X1
ETAILn.tl.s.
exhaust cap
w /backdre(t damper
corrosion resista t
screen
hing
— roof tile
DIK
b4' sheet metal duct
gauge 26 from fan.
EXHAUST FANS SCHEDULE:
EF #1
MOD: NUTONE
696 N
RPM:
1600
AMPS
0.]6
H. P.:
1/240
CFM:
50
CONDENSER UNIT MOUNTING DETAIL.
n.t.s.
, PROVIDE (2)1 GE.20
TIE DOWNS AT 90• AROUND THE
CIO's CABINET TO SLAB
BOLTED W/ (4)1 -1/2-
= EXPANSION BOLTS.
4- CO4RETE
L=j W:27 L
CONCRETE PAO
I
NEOPREKE PAD
(4)2 EACH SIDE 114 HILTI BOLT41 CONC. EXPANSION ANCHOR.
AN ANCHOR BOLT W/ A MIN OF SW POUNDS PULL-OUT
RE818TENCE SHALL SECURE THE AIR CONDITIONING; CONDENESER
UNIT FEOM WITHIN THE UNIT THROUGH TO THE CONCRETE SLAB
(AC- OTE.
AC. FLOOR PLAN EW UNIT AC-2 2.0 TON CAPACITY.
SCALE: 1/4" = t' -o" ELOCATE EXISTING AC-1 AS SHOWN. REPLACE OLD EXISTING UNI
1 WITH NEW SAME CAPACITY As OLD EXIST.AC -1
Architect RubenTravieso
AR 000 8229
2248 SW 57 AV., MIAMI, FL 33155
786.260.7522 Call - 786 - 388-0312 PHN
786.388.0366 FAX
E4YWL: mbantravlaso@hsllsouth.net
L 0 REVISIONS:
DATE: # DATE:
8 -741
9-141
PROJECT:
REAR ADDITION
AND REMODELING
6321 SW 62nd CT
SOUTH MIAMI, FL
p
SHEET CO TENT:
AC
ALL IDEAS, DESIGNS, ARRANGEMENTS
AND PLANS INDICATED OR REPRESEN-
TED BY THIS DRAWING ARE OWNED
BY, AND THE PROPERTY OF THIS OF-
FICE AND WERE CREATED, EVOLVED
AND DEVELOPED FOR USE ON, AND
IN CONNECTION WITH THE SPECIFIED
PROJECT. NONE OF SUCH IDEAS, DE-
SIGNS, ARRANGEMENTS OR PLANS SHALL
BE USED BY OR DISCLOSED TO ANY
PERSON, FIRM OR CORPORATION FOR
ANY PURPOSE WHATSOEVER WITHOUT
THE EXPRESSLY WRITTEN PERMISSION
OF RUBEN TRAVIESO, ARCHITECT.
PROJECT NUMBER:
ISSUED:
DRAWN BY: M.P.
CHECKED BY: R.T
FILENAME:
AC -1
1