Loading...
11-532-008NO. DESCRIPTION WIDTH HEIGHT MATERIAL TYPE FRAME REMARKS QT. 0 DOUBLE GLASS DOOR 72" 80" METAL /GLASS FULL VIEW METAL MASTER B., DINING 2 2 SINGLE - EXTERIOR 36" 80" METAL COMPACT METAL KITCHEN 1 (D SINGLE - EXTERIOR 30" 80" METAL COMPACT METAL STORAGE - NON IMPACT 2 0 EXISTING TO REMAIN WINDOW SCHEDULE DESCRIPTION " INTERIOR PARTITION HORIZONTAL III ROLLER I • d FRONT I WINDOWS HORIZONTAL 111111 �� IIII II ROLLER I •� �•�I ��� I� ��� I KITCHEN, � :A: II HORIZONTAL R IIII III �Il ROLLER . II : I •�I! ` , III . WINDOWS HORIZONTAL 11 ROLLER .II o EXISTING BATHS WOOD CLEATS, ATTACHED HORIZONTAL ROLLER MASTER � BATH II IIII HORIZONTAL ROLLER TO WOOD BLOCKING W /'rtvf EXISTING TO REMAIN tiffif-lio masam" Oil • i • • i ROOF 2"x 4" MTL. STUD HEADER - ATTACHED TO EXIST.CONC ROOF W/ POWER DRIVEN CONC. NAILS @ 24" Q.G. irmo TYPICAL INTERIOR PARTITION Architect RubenTravieso AR 0 2248 SW 57 AV., MIAMI, FL. 33155 786.260.7522 Cell - 786-:: 786.388.0366 .. E-MAIL: • r r • • �•bV _. " INTERIOR PARTITION CITY F - d SHEET CONTENT: CORNER DETAIL BUILDING INN N.T.S. STRUCTURAL! o WOOD CLEATS, ATTACHED t- TO WOOD BLOCKING W /'rtvf NO.8 DRYWALL SCREWS GENERAL NOTES: ` t E3Yµ m d SPACED @ 16- Q.C. (MIN.) 5. NUMBERS OF ADDRESS SHALL BE PLACED VISIBLE AND LEGIBLE FROM THE STREET FRONTING THE PROPERTY° PROVIDE 2X4 WOOD BACKING 1. BATHROOM FLOORS AND BASE TO BE OF IMPERVIOUS AND SHALL BE 3 INCHES MIN. IN HEIGHT. ---- OR 20 GAUGE STUD MATERIAL. IN BETWEEN STUDS 2. CUT EDGES AND OPENINGS AROUND PIPES AND FIXTURES 6. TOILET ROOMS SHALL COMPLY WITH F.B.C. 2004 j AT KITCHEN CABINETS STUD SHALL BE CAULKED FLUSH WITH WATERPROOF, FLEXIBLE SHOWER DETAIL Co WALL WALL, AT 16 O.C. (TYP.) SEALANT OR ADHESIVE COMPLYING WITH ANSI A 136.1, 7. ALL WATER CLOSETS, LAVATORIES, SHOWER HEADS, AND -1 CABINETS AMERICAN NATIONAL STANDARD FOR ORGANIC ADHESIVES SINKS SHALL COMPLY WITH FBC 2004 N.T.S. TYPICAL STAINLESS STEEL FOR INSTALLATION OF CERAMIC TILE. TYPE I OR TYPE II. THE TILE, WALL PANEL, OR OTHER SURFACING MATERIAL 8. REFER TO FOUNDATION PLAN (SHEET S-1) FOR CONCRETE FINISHED WALL CABINETS, MANUFACTURERS SPECIFICATIONS SHALL BE FOLLOWED. FILLED BLOCK CELL LOCATION, SIZE AND REINFORCING. W/ ADJUSTABLE SHELVES TYPICAL STAINLESS STEEL 3. TILE OR WALL PANELS SHALL BE APPLIED DOWN TO THE TOP SURFACE OR EDGE OF THE FINISHED SHOWER FLOOR, 9. EVERY CLOSET LATCH SHALL BE SUCH THAT CHILDREN CAN NOTE:,'; 1. MOISTURE RESISTANT GYPSUM BOARDS FINISHED COUNTERTOP & RETURN, OR TUB AND SHALL OVERLAP THE TOP LIP OF THE OPEN THE DOOR FROM INSIDE THE CLOSET. EVERY BATHROOM (GREEN BOARDS) MUST NOT BE USED AS BACKSPLASH RECEPTOR, SUB-PAN, OR TUB AND SHALL COMPLETELY DOOR LOCK SHALL BE DESIGNED TO PERMIT THE OPENING OF BACKER DIRECTLY BEHIND TUB TILES OR t4 COVER THE AREAS SPECIFIED IN SECTIONS. THE LOCKED DOOR FROM THE OUTSIDE IN AN EMERGENCY. SHOWER AREAS, FBC R702.4.3. USE of CID WOOD CLEATS, ATTACHED DUROCK AS TILE BACKING ON WET AREAS. SHOWER DOOR OR CATT. R �– BASE TO WOOD BLOCKING (a) TUBS WITHOUT SHOWER HEADS - SURFACING MATERIAL 10. PROVIDE CAT. II SAFETY GLASS TO ALL SLIDING, SWINGING DOORS, 4" METAL STUD PARTITION TEMP. GL. SHOWER ENCLOS. CABINETS SHALL EXTEND NOT LESS THAN 70 IN. (150 mm) ABOVE THE SHOWER ENCLOSURES AND WITHIN 60" A.F.F. OFF TUBS AND SHOWERS REFER TO FLOOR PLAN REFER TO FLOOR PLANS 2X4 WOOD BLOCKING RIM OF THE TUB. 2004 FBC ILE -- OR 20 GAUGE STUD ATTACHED TO 3 5/8- METAL STUDS (b) TUBS WITH SHOWER HEADS - SURFACING MATERIAL SHALL EXTEND NOT LESS THAN 5 fL (1500 mm) ABOVE THE RIM OF 11. SHOWER COMPARTMENTS SHALL COMPLY WITH 2004 FBC. 1/2" GYPSUM DRYWALL RECESS SLAB 4- FOR THE TUB OR 6 IN. (150mm) ABOVE THE HEIGHT OF THE FLOORS AND WALLS CONSTRUCTED OF SMOOTH, CORROSION RESISTANT ..__. "._ _..._ .___ SHOWER ENCLOSURE TYP. WD. BLOCKING, & CROSS SHOWER HEAD, WHICHEVER IS HIGHER. AND NONABSORBENT WATER - RESISTANT MATERIALS TO A HEIGHT OF Q /2 U OI C TU E ES ST. BRACING AS REQUIRED LESS THAN 70 INCHES ABOVE THE COMPARTMENT FLOOR — - MARBLE FLOOR BY CABINET MANUF. 4 IN AN OUTSIDE WINDOW OR DOOR OPERABLE FROM THE AT THE DRAIN. - INSIDE, THE MODE OF OPERATION SHALL NOT REQUIRE z _o. T TOP OF CONCRETE SLAB 00 DRYWALL FINISHED, 3 5/8 " THE USE OF A KEY, TOOL, SPECIAL KNOWLEDGE OR 12. OCCUPANCY FBC. SECTION 311 GROUP R3 _ ELEV. 0" -0" �y METAL STUD PARTITION EFFORT. SUCH CLEAR OPENING SHALL BE NOT LESS THAN TYPE CONSTRUCTION ALLOWED =TYPE V -B L PE OR 20 GAUGE STUD 20- IN WIDTH, AND 24- IN HEIGHT, 5.7 SQ. FT. IN AREA ' �_ ®' 1/$ " MASONITE BACK AND SHALL ALSO MEET THE PROVISIONS OF SECT. 1305. NOTE: = �--- �-: -- PLASTIC LAMINATE FINISH THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN PLANS TO COMPLY WITH FBC 2007 LATEST EDITION 44" ABOVE THE FINISHED FLOOR AND NO PART OF THE TOP OF CONCRETE SLAB OPERATING MECHANISM SHALL BE PLACED HIGHER THAN 40 MILLS SARLOY VINYL s" x s- CONT. MONOLITHIC - OL T ELEV. 0 "-0" 54" ABOVE FINISHED FLOOR. WATER PROOFING, 8 FTG. W/ 1 #5 CONT. �- EXISTING ROOF NOTE: EXTEND VINYL 10- (MIN.) (MIN.) LEVELOR LEGS AS REQUIRED KITCHEN NOTES: MIN. UP STUD WALL BY CABINET MANUF, - NEW CLAY TILE TO REPLACE EXISTING GRAVEL ROOF, BY OTHERS; 6- x 6" 10/10 W.W.M. DOUBLE MESH X 2-6" TYPICAL PLASTIC LAMINATE PROVIDE 20 GA. MTL. STUDS Q 16.O.C. @KITCHEN UNDER SEPARATE PERMIT. INTO THE SLAB FINISHED TOE -KICK CABINET WALL (REFER TO DET. 2 ON SHT. D-1} - RE -NAIL EXIST. 5/8" CDX PLYWOOD SHEATHING WITH 8d RING SHANK VAPOR BARRIER TYP. SECTION THRU COUNTER NAILS @ 4.O.C. @ OVERHANG (ALL AROUND BOUNDARIES) @ 6.O.C. N.T.S. @ RESTANT PANEL EDGES & SUPPORTS. Architect RubenTravieso AR 0 2248 SW 57 AV., MIAMI, FL. 33155 786.260.7522 Cell - 786-:: 786.388.0366 .. E-MAIL: • r r • • �•bV _. " d SHEET CONTENT: