10-635-001R R I G A T 1 0 N N 0 T E S
1.) SOME PIPE LINES ARE DRAWN OFF SET FOR CLARITY. INSTALL ALL
IRRIGATION LINES IN LANDSCAPED AREAS.
2.) REFER TO THE LANDSCAPE PLANS WHEN TRENCHING TO AVOID TREE
ROOT BALLS A14D TO INSTALL HEADS AT APPROPRIATE LOCATIONS.
3.) ADJUST ALL NOZZLES TO REDUCE OVERTHROW ON PAVING & WALLS.
THROTTLE ALL IRRIGATION CONTROL VALVES AS REQUIRED TO PREVENT
FOGGING. SET CONTROLLER RUN TIMES TO MATCH PLANT WATER NEEDS
AND SOIL CONDITIONS.
4.) INSTALL RISERS 18" FROM WALLS AND A MINIMUM CF 12" FROM ANY
SIDEWALK, OR ROAD. RISERS ARE TO BE PAINTED FLAT BLACK.
5.) TOP OF SPRAY AND ROTOR HEADS SHALL BE SET AT TOP OF SOD OR
TOP OF MULCH LAYERS.
6.) REFER TO UTILITY PLANS PRIOR TO TRENCHING. THE IRRIGATION
INSTALLER SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE TO
UTILITIES CAUSED BY THEIR WORK DURING THE PROJECT,
7.) ALL WORK SHALL BE GUARANTEED FOR ONE YEAR FROM THE DATE OF
FINAL ACCEPTANCE AGAINST ALL DEFECTS IN EQUIPMENT AND
WORKMANSHIP.
8.) ELECTRIC POWER SUPPLY FOR THE IRRIGATION CONTROLLER SHALL BE
BROUGHT TO A JUNCTION BOX AT THE CONTROLLER LOCATION BY THE
SITE MEP CONTRACTOR.
9.) IRRIGATION WATER CONNECTIONS AND SYSTEM CONSTRUCTION SHALL
COMPLY WITH THE REQUIREMENTS OF LOCAL CODES FOR IRRIGATION
INSTALLATION AND CONNECTIONS TO THE WATER SUPPLY.
10.) SIXTY {60) PSI MINIMUM STATIC WATER PRESSURE IS REQUIRED FOR
THE EFFICIENT OPERATION OF THE IRRIGATION SYSTEM AS DESIGNED.
VERIFY THE MINIMUM STATIC WATER PRESSURE IS AVAILABLE AT THE
PROJECT SITE PRIOR TO BEGINNING THE IRRIGATION INSTALLATION. NOTIFY
THE LANDSCAPE ARCHITECT IF THE MINIMUM STATIC WATER PRESSURE IS
NOT AVAILABLE.
` CL. 200 PVC LATERAL
REFER TO PLAN FOR LINE SIZE
\-SCH. 40 PVC TEE FITTING
SHRUB RISER
GATE VALVE
NOT TO SCALE
10" ROUND VALVE BOX.
CAST IRON GASKETED GATE VALVE
NON RISING STEM
REFER TO IRRIGATION
PLAN AND KEY
6" PVC EXTENSION AS NEEDED
- II1["1I
1I -11
EXCAVATED MATERIAL
COMPACTED EXCAVATED MATERIAL
I R R I G A T T O'N L E G E N D
�\ IRRIGATION WATER TAP AND WATER METER. SIZE INDICATED ON PLAN.
PROVIDED BY THE IRRIGATION INSTALLER, PER LOCAL CODES.
REDUCED PRESSURE BACKFLOW PREVENTER. PROVIDED BY IRRIGATION
INSTALLER, PER LOCAL CODES.
WATTS 909, OR EQUAL.
RSQIRRIGATION CONTROLLER WITH RAIN SWITCH. NUMBER OF STATIONS
INDICATED ON PLAN. 120 VOLT, 3 AMP, ELECTRIC CIRCUIT FROM NEAREST
ELECTRICAL PANEL, BY THE SITE MEP CONTRACTOR.
RAINBIRD ESP -LX SERIES WITH MINI -CLICK RAINSWITCH.
S P R A Y B O D I E S
RAINBIRD 1800 SERIES SPRAY BODIES & ADAPTERS
USE FLEXIBLE PVC CONNECTIONS
PROVIDE MPR SPRAY NOZZLES PER PLAN
S 6" PCP -UP TURF SPRAY BODY
T e 12" POP -UP SHRUB SPRAY BODY
R ■ X'° SHRUB NOZZLE ON PVC RISER
SPRAY HEAD NOZZLE CHART
SHRUB NOZZLE ADAPTOR
PH: 954 -283 -8839 Fax: 954-773-9841
AND SPRAY NOZZLE
_ W
1/2" SCH.40 PVC, PAINT FLAT BLACK
OFFICE TENANT
50
v
3/4- ANGLE IRON REINFORCEMENT
U
EXTEND 2' ABOVE FINISHED GRADE
RADIUS
PATTERN
PEREZ - QUINTAIROS
NYLON ZIP STRIP FASTENERS
PAINT FLAT BLACK
�-
FINISHED GRADE
6310 SUNSET DRIVE
PVC FEMALE ADAPTER
MIAMI. FLORIDA 33143
THREADED STREET ELL
` CL. 200 PVC LATERAL
REFER TO PLAN FOR LINE SIZE
\-SCH. 40 PVC TEE FITTING
SHRUB RISER
GATE VALVE
NOT TO SCALE
10" ROUND VALVE BOX.
CAST IRON GASKETED GATE VALVE
NON RISING STEM
REFER TO IRRIGATION
PLAN AND KEY
6" PVC EXTENSION AS NEEDED
- II1["1I
1I -11
EXCAVATED MATERIAL
COMPACTED EXCAVATED MATERIAL
I R R I G A T T O'N L E G E N D
�\ IRRIGATION WATER TAP AND WATER METER. SIZE INDICATED ON PLAN.
PROVIDED BY THE IRRIGATION INSTALLER, PER LOCAL CODES.
REDUCED PRESSURE BACKFLOW PREVENTER. PROVIDED BY IRRIGATION
INSTALLER, PER LOCAL CODES.
WATTS 909, OR EQUAL.
RSQIRRIGATION CONTROLLER WITH RAIN SWITCH. NUMBER OF STATIONS
INDICATED ON PLAN. 120 VOLT, 3 AMP, ELECTRIC CIRCUIT FROM NEAREST
ELECTRICAL PANEL, BY THE SITE MEP CONTRACTOR.
RAINBIRD ESP -LX SERIES WITH MINI -CLICK RAINSWITCH.
S P R A Y B O D I E S
RAINBIRD 1800 SERIES SPRAY BODIES & ADAPTERS
USE FLEXIBLE PVC CONNECTIONS
PROVIDE MPR SPRAY NOZZLES PER PLAN
S 6" PCP -UP TURF SPRAY BODY
T e 12" POP -UP SHRUB SPRAY BODY
R ■ X'° SHRUB NOZZLE ON PVC RISER
SPRAY HEAD NOZZLE CHART
PROVIDE NOZZLE PET? PLAN
NOTE: INSTALL SPRINKLER
AT FINISHED GRADE :N TURF
ABOVE MULL -4 IN BEDS,
APPROVED BACKFILL
00 NOT USE SIDE INLET
WHEN PRESSURE REGULATION
iN HEAD DOES NOT ALLOW.
SPRAY SPRINKLER BODY
18" OF FLEXIBLE
PVC PIPE AND
THREADED FITTING
1--- LATERAL PIP:
LATERAL TEE
SPRAY
NOT TO SCALE
CONTROL
WIRES
MAIN SUPPLY. LATERAL
AND CABLE OR WIRING
TYPICAL TRENCHING
NOT TO SCALE
COIL CONTROL WIRES IN BOX
i-' -WATER PROOF CONNECTION
15" STANDARD
PLASTIC VALVE BOX
- -"-FINISH GRACE
I REMOTE CONTROL VALVE:
4" SIZE NOTED ON PLAN
USE CONCRETE BRICK
TO SET BOX ELEVATION
AND SEAL BOTTOM OF VALVE PIT.
(NO BRICK RESTS ON PIPE)
,
r ,
PVC MAINLINE PIPE
18" MIN. DEPTH
TAPE WIRES BENEATH PIPEWORK
PVC LATERAL PIPE
12" MIN. DEPTH
REMOTE CON TR\',')L VALVE
00-1;QUICK COUPLER VALVE.
POSITION IN VALVE BOX S0
THAT KEY MAY BE
-OPERATED ;'JtTHOUT
INTERFERENCE.
r__I" ANGLE IRON - 24" LONG
i
SECURED TO QUICK COUPLER
}1 WITH 2 STAINLESS STEEL
HOSE CLAMPS.
IV' ROUND PLASTIC VALVE BOX
0 -RING PVC TRIPLE
SWING JOINT. SAME
SIZE AS QUICK
COUPLER.
1 - THREADED SERVICE TEE
BRASS QUICK COUPLER VALVE
EXTERNAL WALL MOUNT IRRIGATION
CONTROLLER WITH INTERNAL 3 -WIRE STEP
DOWN TRANSFORMER AND LOCKING CABINET.
SECURE TO BUILDING WALL.
1.5" PVC SCH. 40 CONDUIT AND FITTINGS
JUNCTION BOX
1" PVC SCH. 40 CONDUIT TO POWER SUPPLY
HIRES TO REMOTE CONTROL VALVES - 24
VOLT SECONDARY CIRCUIT
___'`�- ---120 VOLT, 3 AMP, 3 WARE PRIMARY CIRCUIT
FROM DEDICATED BREAKER IN ELEC. PANEL PER
CODES, BY ELECTRICAL CONTRACTOR,
WALL MOUNTED CON TROLLER
NOT TO SCALE NOT TO SCALE f NOT TO SCALE
NOT TO SCALE
i
�t
- --MARK LOCATION OF SLEEVE VOT;•I A
SECTION PVC PIPE
LOCATE BOTH ENDS OF SLEEVE
--- EXTEND ALL SLEEVES 2' -0" BEYOND
EDGE OF PAVEMENT, TYPICAL
-DECK PAVEMENT
FINISHED GRADE- VARIES
/ COMPACTED SUB -BASE
FILL /PLANTING FILL /EXISTING SOIL
CONDITION VARIES
SCHEDULE 40 PVC SLEEVE.
SIZE AS NOTED ON PLANS
W CAP BOTH ENDS OF PVC SLEEVE
BELOW GRADE AND LEAVE CAPS
UNGLUED ON PVC SLEEVE
UNDISTURBED SOIL
SLEEVE UNDER PAVING
RAIN SEN,50R
(ON UJALL. AS SN=
ON PLAN)
GALV. PIPE
(ON WALL AS SWM
ON PLAN)
1' PYB
` -MAN LNE
/- -GALV. PIPE
l-6' CONC. PAD
11 SOLEN010
GAM VAL�S
DETAIL ',fit N.T.S.
NOT TO SCALE
t
Consultants
7
n
J
Heery International Inc.
811 Pance De Leon Blvd.
Coril Gvbles, FL 33134
TEL: (;ft) 441 -9556 q
FAX (305) 445 -2374
httP:/ /www.s- garchitects.com
AA 0002293
ES 0005176
Project Number
0723701
u
U
a
S
S
t
7551 Wiles Rd. Suite# 205E Coral Springs, FL 33067
IRRIGATION CONTROL VALVE. PLASTIC BODY WITH FLOW CONTROL.
PH: 954 -283 -8839 Fax: 954-773-9841
GPM AT
OFFICE TENANT
50
MOUNT IN 15" RECTANGULAR VALVE BOX. SIZE INDICATED ON PLAN.
x
LETTER
30 PSI
RADIUS
PATTERN
PEREZ - QUINTAIROS
RAINBIRD PEB PRS VALVE SERIES, OR EQUAL.
i
6310 SUNSET DRIVE
MIAMI. FLORIDA 33143
-
A
0.9
15'
QUARTER
1" BRASS QUICK COUPLER VALVE. MOUNT ON O -RING TYPE SWING JOINT
8
G
1.25
1.85
15'
15.
ONE THIRD
HALF
z
AND STABILIZE IN 10" ROUND VALVE BOX. PROVIDE ONE QCV KEY WITH
D
2.5
15'
TWO THIRD
3/4" HOSE SWIVEL ADAPTER PER TWO QUICK COUPLER VALVES.
E
2.8
15'
THREE QTR.
T_
2
RAINBIRD 44LRC VALVE WITH 44K KEY + SH -1.
6
F
3.7
15'
FULL
A
.Y.
O
G
0.65
12'
QUARTER
04
IRRIGATION CONTROL VALVE TAG. INDICATES VALVE LOCATION, STATION
W
Vt
S
H
J
0.9
12'
12'
ONE THIRD
HALF
55 GPM 1.5 °'
NUMBER, SIZE AND ZONE FLOW RATE.
Checked By:
1.3
1.75
12'
74'o THIRD
Drawn By:
;
J.S.
1.95
12'
THREE QTR.
xx -xx -xx
h a
Date:
M
2.6
12'
FULL
n
0
IRRIGATION ISOLATION VALVE. SIZE SAME SIZE AS PIPE. MOUNT IN 10"
a
W
N
0,4
10'
QUARTER
ROUND VALVE BOX INITH 6" DIAMETER PIPE EXTENSION AS NEEDED.
P
0.5
10'
ONE THIRD
G
2.5" AND SMALLER - BRONZE THREAD ON TYPE WITH WHEEL HANDLE,
z
R
0.8
10'
HALF
PROVIDE ONE VALVE KEY FOR EACH TYPE VALVE INSTALLED.
U
V
V
0.6
1.2
4' X 15'
X
4" X 30'
END STRIP
SIDE STRIP
W
1.2
4' X 30'
CENTER STRIP
SIZE
PVC MAIN LINE WIPE. CLASS 200, PVC. INSTALL 18" DEEP.
X
Z10
1.7
VARIES
9' X 18'
10'
SIDE STRIP
10' ADJUSTABLE ARC
2.5" AND SMALLER, SOLVENT WELD PVC PIPE AND FITTINGS.
Z12
VARIES
12'
12' ADJUSTABLE ARC
Z
VARIES
15'
15' ADJUSTABLE ARC
SIZE
PVC LATERAL LINE PIPE. CLASS 200, PVC. INSTALL 12" DEEP.
Y
o.s
2'
ADJUSTABLE
FLOOD BUBBLER
2.5" AND SMALLER, SOLVENT WELD PVC PIPE AND FITTINGS.
0
1.0
5'
STREAM BUBBLER
SIZE SLV.
PVC SLEEVE PIPE. SCH 40, PVC.
SOLVi =NT WELD PVC PIPE AND FITTINGS.
PROVIDE NOZZLE PET? PLAN
NOTE: INSTALL SPRINKLER
AT FINISHED GRADE :N TURF
ABOVE MULL -4 IN BEDS,
APPROVED BACKFILL
00 NOT USE SIDE INLET
WHEN PRESSURE REGULATION
iN HEAD DOES NOT ALLOW.
SPRAY SPRINKLER BODY
18" OF FLEXIBLE
PVC PIPE AND
THREADED FITTING
1--- LATERAL PIP:
LATERAL TEE
SPRAY
NOT TO SCALE
CONTROL
WIRES
MAIN SUPPLY. LATERAL
AND CABLE OR WIRING
TYPICAL TRENCHING
NOT TO SCALE
COIL CONTROL WIRES IN BOX
i-' -WATER PROOF CONNECTION
15" STANDARD
PLASTIC VALVE BOX
- -"-FINISH GRACE
I REMOTE CONTROL VALVE:
4" SIZE NOTED ON PLAN
USE CONCRETE BRICK
TO SET BOX ELEVATION
AND SEAL BOTTOM OF VALVE PIT.
(NO BRICK RESTS ON PIPE)
,
r ,
PVC MAINLINE PIPE
18" MIN. DEPTH
TAPE WIRES BENEATH PIPEWORK
PVC LATERAL PIPE
12" MIN. DEPTH
REMOTE CON TR\',')L VALVE
00-1;QUICK COUPLER VALVE.
POSITION IN VALVE BOX S0
THAT KEY MAY BE
-OPERATED ;'JtTHOUT
INTERFERENCE.
r__I" ANGLE IRON - 24" LONG
i
SECURED TO QUICK COUPLER
}1 WITH 2 STAINLESS STEEL
HOSE CLAMPS.
IV' ROUND PLASTIC VALVE BOX
0 -RING PVC TRIPLE
SWING JOINT. SAME
SIZE AS QUICK
COUPLER.
1 - THREADED SERVICE TEE
BRASS QUICK COUPLER VALVE
EXTERNAL WALL MOUNT IRRIGATION
CONTROLLER WITH INTERNAL 3 -WIRE STEP
DOWN TRANSFORMER AND LOCKING CABINET.
SECURE TO BUILDING WALL.
1.5" PVC SCH. 40 CONDUIT AND FITTINGS
JUNCTION BOX
1" PVC SCH. 40 CONDUIT TO POWER SUPPLY
HIRES TO REMOTE CONTROL VALVES - 24
VOLT SECONDARY CIRCUIT
___'`�- ---120 VOLT, 3 AMP, 3 WARE PRIMARY CIRCUIT
FROM DEDICATED BREAKER IN ELEC. PANEL PER
CODES, BY ELECTRICAL CONTRACTOR,
WALL MOUNTED CON TROLLER
NOT TO SCALE NOT TO SCALE f NOT TO SCALE
NOT TO SCALE
i
�t
- --MARK LOCATION OF SLEEVE VOT;•I A
SECTION PVC PIPE
LOCATE BOTH ENDS OF SLEEVE
--- EXTEND ALL SLEEVES 2' -0" BEYOND
EDGE OF PAVEMENT, TYPICAL
-DECK PAVEMENT
FINISHED GRADE- VARIES
/ COMPACTED SUB -BASE
FILL /PLANTING FILL /EXISTING SOIL
CONDITION VARIES
SCHEDULE 40 PVC SLEEVE.
SIZE AS NOTED ON PLANS
W CAP BOTH ENDS OF PVC SLEEVE
BELOW GRADE AND LEAVE CAPS
UNGLUED ON PVC SLEEVE
UNDISTURBED SOIL
SLEEVE UNDER PAVING
RAIN SEN,50R
(ON UJALL. AS SN=
ON PLAN)
GALV. PIPE
(ON WALL AS SWM
ON PLAN)
1' PYB
` -MAN LNE
/- -GALV. PIPE
l-6' CONC. PAD
11 SOLEN010
GAM VAL�S
DETAIL ',fit N.T.S.
NOT TO SCALE
t
Consultants
7
n
J
Heery International Inc.
811 Pance De Leon Blvd.
Coril Gvbles, FL 33134
TEL: (;ft) 441 -9556 q
FAX (305) 445 -2374
httP:/ /www.s- garchitects.com
AA 0002293
ES 0005176
Project Number
0723701
u
U
a
S
S
t
7551 Wiles Rd. Suite# 205E Coral Springs, FL 33067
PH: 954 -283 -8839 Fax: 954-773-9841
v,vAv,fontdestgns.net
OFFICE TENANT
IMPROVEMENT FOR
x
DR. ILEANA R.
S
u
PEREZ - QUINTAIROS
i
6310 SUNSET DRIVE
MIAMI. FLORIDA 33143
-
n
Revisions Date
z
a
n
x
4
z
z
z
T_
2
6
a
Seal:
z
.Y.
O
n
v
n
c
a
x
N
[D
B
`s
J
N
W
X
W
Vt
S
z
a
Q
w
a
K
d
Checked By:
D.F.
Drawn By:
;
J.S.
Issue:
a
W
xx -xx -xx
h a
Date:
U
02 -13 -08
W
Sheet Index:
n
0
IRRIGATION
a
W
DETAILS &
K
NOTES
v
w
v
a
'a
G
z
Sheet Number:
Q_z; n