11-473-025m
m o
�7�i
o
m o
i
� o �
N
Lo
I o
i o
ago
DO
ci
a�
U
co a- :ii
ITEM
FIXTURE
SOIL OR
WASTE
VENT
COLD
WATER
HOT
WATER
TEMP'D
WATER
DESCRIPTION
MANUFACTURER / MODEL NUMBER
WC 1
O
WATER
CLOSET
4"
2"
1/2°
--
-
WHITE VITREOUS CHINA FLOOR MOUNTED FLUSHOMETER TANK (PRESSURE ASSISTED) TYPE, ELONGATED BOWL,
ADA COMPLIANT, MAX. 1.1 GPF, WITH OPEN FRONT SEAT LESS COVER, OLSENITE #95 OR EQUIVALENT.
FLUSHOMETER TANK: SLOAN FLUSHMATE OR EQUAL, PROVIDE TANK COVER LOCKS. FLUSH HANDLE SHALL B RIGHT
HAND AS REQUIRED TO CORRESPOND WITH ACCESS FROM WIDE SIDE OF STALL. VERIFY FLUSH SIDE REQUIREM
AM. STD. "CADET" / MODEL: 3483.100/4142.901
KOHLER "HIGHLINE" /MODEL: K- 3519 -TR
CRANE "ECONOMISER" / MDL:31 1 28/31 961TP
S 1
HAND SINK
2"
1 -1/2"
I
-
--
1/2"
STAINLESS STEEL HAND SINK, WALL HUNG, INCLUDES A 6" GOOSENECK STAINLESS. FAUCET W /FOOT VALVE
PER DETAIL F /P1.0. CONTRACTOR TO PROVIDE AND INSTALL 1/2" FLEXIBLE COPPER SUPPLIES WITH WHEEL
HANDLE STOP, 1 -112" CHROME PLATED BRASS "P" TRAP WITH CLEANOUT PLUG. INSTALLED BY CONTRACTOR.
REFER TO DETAIL 2/M2.0.
SINKA11D FAUCET PROVIDED BY OWNER
U_
--
S 2
MOP SINK
3"
2"
1/2"
1/2"
--
MOP SINK: AERO MODEL: #3MP - 2121 -6, 24 "x24" BASIN WITH 48" HIGH STAINLESS STEEL RIGHT
SIDE AND BACK - SPLASH. INSTALLED BY CONTRACTOR.
FAUCET: T &S #B -2465, WITH VACUUM BREAKER, WALL BRACKET, 4" WRIST BLADE HANDLES,
INSTALLED BY CONTRACTOR. REFER TO DETAIL 5/M2.0.
SINK AND FAUCET PROVIDED BY OWNER
--
WH 1
WATER
HEATER
--
--
3/4"
3/4"
--
GAS FIRED TANKLESS WATER HEATER, 199,000 BTU/H INPUT, 7.5 GAUMIN CAPACITY AT 45 °F
RISE, POWER VENTED /SEALED COMBUSTION, WALL MOUNTED, DIRECT IGNITION, S.S. CASING
AND FLUE COLLAR, COPPER SHEETINGITUBING PRIMARY HEAT EXCHANGER, S.S. SHEETING/
TUBING SECONDARY HEAT EXCHANGER, LIGHTNING PROTECTION, FAN ROTATION DETECTOR
RINNAI /MODEL: R94LSi 2
CONTRACTOR TO PROVIDE AND INSTALL
WH 2
WATER
HEATER
--
3/4"
3/411
GAS FIRED TANKLESS WATER HEATER, 199,000 BTU /H INPUT, 7.5 GAUMIN CAPACITY AT 45 °F
RISE, POWER VENTED /SEALED COMBUSTION, WALL MOUNTED, DIRECT IGNITION, S.S. CASING
AND FLUE COLLAR, COPPER SHEETING/TUBING PRIMARY HEAT EXCHANGER, S.S. SHEETING/
TUBING SECONDARY HEAT EXCHANGER, LIGHTNING PROTECTION, FAN ROTATION DETECTOR
RINNAI / MODEL: R94LSi 2
CONTRACTOR TO PROVIDE AND INSTALL
MV 1
MIXING
VALVE
-
--
112"
1/2"
--
THERMOSTATIC, 125 P516, 200VF BRONZE BODY, STAINLESS STEEL PISTON LINER,
CHECK VALVES SIZE PER PIPE CONNECTIONS.
HYD ROTE K SERIES HBL
LAWLER SERIES 61
LEONARD SERIES 210
SA 1
SHOCK
ARRESTOR
--
--
1/2"
--
--
STAINLESS STEEL CASING WITH STAINLESS STEEL BELLOW, PRECHARGED WITH NITROGEN.
SIZED PER PDI -WH2O1
WADE / SHOKSTOP
J08AM / MODEL: 75000
ZURN / SHOKTROL
FD 1
FLOOR DRAIN
3"
2"
--
--
--
CAST IRON FLOOR DRAIN WITH FLANGE, INTEGRAL CLAMPING COLLAR, 6" DIA,
JOSAM / MODEL: 30003 -A
WADE/ MODEL: 1103
ZURN / MODEL: Z- 415 -6H
FCO 1
FLOOR
CLEANOUT
--
--
--
--
--
CAST IRON CLEANOUT WITH THREADED ADJUSTABLE HOUSING, ROUND SCORIATED
HEAVY CAST IRON COVER.
JOSAM / MODEL: 56000
WADE/ MODEL: 60002
ZURN / MODEL: Z -1400
FS 1
FLOOR SINK
2"
2"
--
--
--
CAST IRON SQUARE FLOOR SINK, 6" DEEP, WITH ALUMINUM DOME STRAINER
AND NICKEL BRONZE HINGED TOP.
JOSAM / MODEL: 49322A
WADE/ MODEL: 9112
ZURN / MODEL: Z- 1900 -32
CO 1
WALL
CLEANOUT
--
--
--
--
--
CAST IRON CLEANOUT TEE WITH INLET- /OUTLET SPIGOT AND THREADED BRASS
PLUG, WITH STAINLESS STEEL ACCESS COVER.
JOSAM / MODEL: 58510
WADE/ MODEL: 8560E
ZURN / MODEL: Z- 1446 -BP'
1O INSTALL TO MEET ADA REQUIREMENTS.
O2 PROVIDE AND INSTALL WITH VENTING AND MANUFACTURER'S ROOF TERMINATION PER MANUFACTURER'S INSTALLATION INSTRUCTIONS.
PLUMBING FIXTURE SCHEDULE
D
1. PLANS ARE SCHEMATIC IN NATURE. LAYOUT IS BASED ON BEST AVAILABLE
INFORMATION. VERIFY ALL EXISTING CONDITIONS BEFORE START OF
CONSTRUCTION, PROVIDE NEW PIPING AS INDICATED AND /OR REQUIRED, AND
CONNECT TO EXISTING LINES WHERE INDICATED AND /OR REQUIRED.
2. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS FOR ROUTING AND
CONNECTION OF WASTE, WATER, AND GAS SERVICES. ALL FIXTURE DRAINS AND
TRAPS TO BE VENTED AS PER LOCAL CODE.
3. CUT FLOOR AS REQUIRED FOR INSTALLATION OF NEW LINES BELOW FLOOR. G.C.
TO PATCH FLOOR TO MATCH EXISTING.
4. INSULATE ALL CONDENSATE PIPING PER SPECIFICATIONS. ALL EQUIPMENT
CONDENSATE SHALL BE ROUTED TO FUNNEL TYPE FLOOR DRAIN, FLOOR SINK, OR
OTHER RECEPTOR APPROVED BY LOCAL AUTHORITIES WITH REQUIRED AIR GAP.
5. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATION, VERIFICATION AND
CONNECTION OF ALL NEW AND EXISTING SERVICES WITH LOCAL UTILITIES AND
AUTHORITIES.
6. PIPING AND CONDUIT IN GENERAL SHALL BE CONCEALED. WHEN EXPOSED IT
SHALL STAND OFF WALLS MINIMUM OF 112" AND 6" AFF OR AS REQUIRED BY
LOCAL AUTHORITIES. WHERE CONDUIT OR PIPE ENTERS A WALL, ROOF, CEILING,
OR FLOOR, THE OPENING AROUND THE PIPING SHALL BE TIGHTLY SEALED.
7. ALL WATER DISTRIBUTION PIPING SHALL BE LOCATED ABOVE FINISHED CEILING
BELOW BUILDING INSULATION, UNLESS OTHERWISE NOTED.
8. SOIL AND WASTE PIPE SHALL SLOPE 1/4" PER FOOT MINIMUM, UNLESS
OTHERWISE NOTED OR REQUIRED BY CODE.
9. ALL VALVES, SHOCK ARRESTORS OR OTHER EQUIPMENT SHOWN IN WALLS OR ABOVE
NON - ACCESSIBLE CEILING SHALL BE INSTALLED BEHIND AN ACCESS PANEL.
10. INSTALL SHUTOFF VALVES ON ALL HOT & COLD WATER LINES TO FIXTURE OR
APPLIANCE. ALL EXPOSED WATER AND WASTE LINES SHALL BE CHROME PLATED.
11. ALL PLUMBING WORK AND MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH
ALL APPLICABLE STATE & LOCAL ORDINANCES & REGULATIONS HAVING
JURISDICTION. CONTRACTOR SHALL OBTAIN ALL APPROVALS REQUIRED FROM
REGULATING AGENCIES BEFORE STARTING WORK. ALL PLUMBING WORK &
MATERIALS SHALL MEET THE REQUIREMENTS OF STATE OF FLORIDA
PLUMBING CODE, UNLESS OTHERWISE REQUIRED BY THE LOCAL AUTHORITIES
HAVING JURISDICTION. OBTAIN & PAY FOR ALL PERMITS, FEES & INSPECTIONS
REQUIRED BY GOVERNING AUTHORITIES. ALL PIPING TO BE CONCEALED UNLESS
NOTED OTHERWISE.
12. ALL VALVES, UNIONS, ETC, TO BE SAME SIZE AS PIPE UNLESS OTHERWISE
INDICATED ON DRAWINGS.
DELETED
PLUMBING GENERAL NOTES C I
EXISTING GAS SERVICE AND GAS METER
VERIFY REGULATOR IS CAPABLE
OF MEETING OF EXCEEDING 660 MBH GAS
DEMAND. VERIFY WITH GAS COMPANY
REPLACE IF NECESSARY
REFER TO PARTIAL
MECHANICAL PLAN ON
SHEET M2.0 FOR
ADDITIONAL WORK
THIS AREA
PLUMBING PLAN
Q REMOVE EXISTING PLUMBING FIXTURE AND ASSOCIATED PIPING AS REQUIRED. COORDINATE DISPOSAL OF FIXTURE
AND WITH OWNER.
INSTALL NEW HAND SINK AND CONNECT NEW 2" WASTE AND 1 -1/2" VENT WITH EXISTING PIPING IN AREA. DROP 112"
TEMPERED HOT WATER DOWN IN WALL TO FOOT PEDAL CONTROL. REFER TO DETAIL 2/M2.0.
112" HOT AND COLD WATER TO TEMPERING VALVE ABOVE CEILING. REFER TO DETAIL 1/P2.0.
Q CONNECT 112" HOT AND COLD WATER TO EXISTING HOT AND COLD WATER LINES ABOVE CEILING. FIELD VERIFY EXACT
LOCATION AND CONNECTION REQUIREMENTS.
Q REMOVE FLOOR DRAIN /FLOOR SINK AND CAP WASTE LINE WATER TIGHT BELOW FLOOR LEVEL. G.C. TO PATCH FLOOR.
Q INSTALL DRINK SYRUP TUBE BUNDLE FROM RELOCATED SYRUP BOX RACK TO DRINK SYSTEM LOCATION. VERIFY
INSTALLATION WITH VENDOR.
RELOCATE EXISTING DRINK SYSTEM AND ICE MACHINE. EXTEND AND RECONNECT WATER LINE(S), SYRUP LINES,
AND REFRIGERANT LINES AS REQUIRED. ROUTE DRAIN LINES TO FLOOR SINK BELOW AND TERMINATE WITH PROPER
AIR GAP.
�g RELOCATE EXISTING DRINK SYSTEM AND ICE MACHINE. EXTEND AND RECONNECT WATER LINE(S), SYRUP LINES,
AND REFRIGERANT LINES AS REQUIRED. ROUTE DRAIN LINES THRU WALLTO NEAREST FLOOR SINK AND TERMINATE
WITH PROPER AIR GAP.
RELOCATE EXISTING WATER FILTER /BOOSTER SYSTEM. RECONNECT WATER LINE AS REQUIRED. FIELD VERIFY
EXACT REQUIREMENTS.
10 RELOCATE EXISTING FROZEN BEVERAGE DISPENSER. RECONNECT WATER LINE AS REQUIRED. FIELD VERIFY EXACT
REQUIREMENTS.
11 ROUTE AND CONNECT 2" VENT AND 3" WASTE TO EXISTING WASTE AND VENT THIS AREA. FIELD VERIFY EXACT
LOCATION AND CONNECTION REQUIREMENTS. G.G. TO PATCH FLOOR AS REQUIRED.
12 REMOVE EXISTING TANK TYPE GAS WATER HEATER, FLUE VENTING, AND ALL ASSOCIATED PIPING AS REQUIRED.
G.C.TO PATCH ROOF WATER TIGHT. COORDINATE DISPOSAL OF UNIT WITH OWNER.
13 REMOVE EXISTING MOP BASIN AND ASSOCIATED PIPING AS REQUIRED. COORDINATE DISPOSAL OF FIXTURE AND
WITH OWNER.
14 ROUTE AND CONNECT 1 -1/2" GAS LINE TO EXISTING GAS LINE ABOVE CEILING THIS AREA. FIELD VERIFY EXACT
LOCATION AND CONNECTION REQUIREMENTS.
15 DO NOT ROUTE PIPING OVER ELECTRICAL PANEL.
OK) 1" HOT AND COLD WATER, AND 1 -112" GAS DOWN TO INSTANTANEOUS GAS WATER HEATERS, REFER TO DETAIL 4/M2.0.
ROUTE DRAIN LINES TO MOP BASIN OR NEAREST FLOOR DRAIN.
17 CONNECT 4" SANITARY WASTE TO EXISTING 4" SANITARY WASTE LINE BELOW FLOOR. FILED VERIFY EXACT LOCATION
AND CONNECTION REQUIREMENTS.
18 ROUTE AND CONNECT 3" WASTE TO EXISTING WASTE LINE BELOW FLOOR. FIELD VERIFY EXACT LOCATION AND
CONNECTION REQUIREMENTS.
19 ROUTE AND CONNECT NEW 2" VENT LINE TO EXISTING VENT THROUGH ROOF. FIELD VERIFY EXACT LOCATION AND
CONNECTION REQUIREMENTS.
20 EXISTING FLOOR DRAIN SERVING COOLER /FREEZER DRAIN LINE TO REMAIN. VERIFY AND RECONNECT WASTE AND
VENT LINES AS REQUIRED.
21 INSTALL NEW T C S A EXI ING FIXTURE LOCATION. MO IFY AS E CO EC ON AS REQUIRED. INSTALL
TO MEET ADA REQUIREMENTS.
22 INSTALL TRAP GUARD TRAP SEAL PROTECTOR IN BODY OF EXISTING FLOOR DRAIN. REFER TO DETAIL 9/M2. .
23 C ECT 1 "HOT AND COLD WATER XI ING 1" HO AND C D T LI S IS A. FIELD VERIFY EXACT
LOCATION AND CONNECTION REQUIREMENTS.
24 CONTRACT HA L INSTALL NEW OFFS RI S RAINER AND P -TRAP AND INSULATE THE WASTE LINE AND HOT
WATER LINE WITH PRE - MANUFACTURED COVER SYSTEM TO MEET ADA REQUIREMENTS.
25 CONTRACTOR SHALL VERIFY EXISTING FIXTURE IS INSTALLED TO MEET ADA REQUIREMENTS. CONTRACTOR SHALL
.., MAKE ANY REQUIRED MODIFICATIONS FOR COMPLIANCE. _ - A, ., j.
PLUMBING KEY NOTES
i
1
N � N
f~p m S
B;; E �
t " O
LL EZ
C c r &W,
=q
w
c.,
W
3m o
wM 0
N LLr F
GREG S. SCHUNK, P.E.
MECHANICAL ENGINEER
FLORIDA LICENSE NO. 62719
m o m N t9 ® sw
UNAL
a
L ae ebb
�pq�R'�Y�99E6'g0m
11009
DATE
g
A 05.16.11
C14 (0
A08,24.11
24
z�cor
t-
�l7 O
0
025743
T
�V U
Q
c.7
cu), F-
Z
O) J
`, _. O
Z Lu
-, -r
ts
C' Q
-W F-
CV L
cis
P.
IFS- -c�aoa
�d
u-
U3 co
U_
O M
_Q
V
a
w
V
N � N
f~p m S
B;; E �
t " O
LL EZ
C c r &W,
=q
w
c.,
W
3m o
wM 0
N LLr F
GREG S. SCHUNK, P.E.
MECHANICAL ENGINEER
FLORIDA LICENSE NO. 62719
m o m N t9 ® sw
UNAL
a
L ae ebb
�pq�R'�Y�99E6'g0m
11009
DATE
DESCRIPTION
A 05.16.11
SUPP. INSTR. NO. 1
A08,24.11
PLAN CHANGE - NEXT 2 TEN
® 11.07.11
PLAN CHANGE - REMODEL
0
025743
0
CONTRACT DATE:
04.17.11
BUILDING TYPE:
M70H
PLAN VERSION:
Sep09A
SITE NUMBER:
298702
STORE NUMBER:
025743
TACO BELL
6310 SOUTH DIXIE HWY
MIAMI, FL
L-
r •
V � A
• I A r
r
M1.0