11-473-007RESTROOM DOORS:
BUTTS: 1 1/2 PR BOMMER BB5000, 4 -1/2" x 4 -1/2"
LOCK: YALE PB5402LN 626
CLOSER: DORMA 7414 ARP SNB 689
KICKPLATE: STAINLESS STEEL 10" x 34"
DOOR STOP: FLOOR STOP - ROCKWOOD 441 CU
PUSH PLATE: ROCKWOOD 70F - 8" x 16"
PULL PLATE. ROCKWOOD 70C x 107 - 4" x 16"
PREFERRED SUPPLIER
0
INTERIOR DOORS, FRAMES & HARDWARE
LOCKNFT
MIKE MOYNAHAN
100 COURCHELLE DRIVE
NICHOLASVILLE, KY 40356
CONTRACT DATE:
BUILDING TYPE:
PLAN VERSION:
SITE NUMBER:
STORE NUMBER:
EMAIL: CONSTRUCTION@LOCKNET.COM
800 - 887 -4307 FAX: 859- 887 -4958
DOOR HARDWARE SCHEDULE
G
PUSH PLATE OR
HANDLE, WHERE
SCHEDULED
SIGN WHERE - -1
REQUIRED
0
m
KICKPLATE
UNDERCUT \ rr
DOOR 3/4" \ !�
0
60
TYPICAL NEW INTERIOR WALL:
2x4 WD STUDS (2X6 OR 2X8 WHERE NOTED) AT 16" O.C. W/
1/2" GYP. BD, SUBSTRATE U.O.N. USE MOISTURE RESISTANT
GYP. BD. BEHIND ALL CERAMIC WALL TILE. U.O.N.
ACCEPTABLE ALTERNATE:
METAL STUDS IN LIEU OF WOOD STUDS.
WALL LEGEND NTS I E I
1. LAMINATE DOORS. SEE INTERIOR ELEVATIONS
2. MOUNT DOOR CLOSERS ON RESTROOM OR KITCHEN SIDE ONLY.
3. MOUNT KICKPLATE ON PUSH SIDE ONLY.
F. F. 4. MAXIMUM DOOR OPERATING PRESSURE: 5 LBS INTERIOR: 8.5 LBS EXTERIOR
MEASURED AT 90 DEGREES TO THE DOOR AT THE STRIKE SIDE EDGE.
5. ADA COMPLIANT ACCESSIBILITY SIGNAGE WHERE REQUIRED (OR AS REQUIRED BY
LOCAL JURISDICTION) - (1) MEN; (1) WOMEN
6. RESTROOM SIGN IF REQUIRED. VERIFY LOCAL REQUIREMENTS,
7. FRAMES SHALL BE PAINTED.
-
DOOR ELEVATIONS NTS F I RESTROOM DOOR GENERAL NOTES
DIMENSIONS:
A. DIMENSIONS THAT ORIGINATE FROM EXISTING ELEMENTS OF THE BUILDING ARE FROM
FACE OF FINISH. ALL OTHER DIMENSIONS ARE TO FACE OF STUD U.O.N. REFER TO
FOUNDATION PLAN FOR FACE OF CONC. DIMENSIONS.
B. DIMENSIONS NOTED AS "CLEAR" OR "HOLD" ARE MIN. REQ'D. NET CLEARANCE' FROM FACE
OF WALL/ WAINSCOT FINISH. VERIFY FINAL EQUIPMENT SIZES W/ VENDOR PRIOR TO INT.
WALL FRAMING.
WINDOWS / DOORS:
A. - SEE SCHEDULE FOR WINDOW AND DOOR TYPES,
B, ALL DOOR AND WINDOW OPENING DIMENSIONS ARE TO ROUGH OPENING.
FINISH SUBSTRATES:
A. PROVIDE 1/2" THICK CEMENTITIOUS BD. FROM FLOOR SLAB TO 12" A.F.F, MIN, IN LIEU OF
GYP. BD. AT ALL WALLS EXCEPT SHEARWALL SURFACES, U.Q.N.
B. ALL JOINTS, GAPS OR SPACES LEADING TO ALL HOLLOW OR INACCESSIBLE SPACES SHALL
BE SEALED WITH "NSF INTERNATIONAL" APPROVED SEALANTS.
C. ALL BACK OF HOUSE AND OFFICE WALLS SHALL HAVE 1/2" CDX PLYWOOD SUBSTRATE,
DECdFP-N.
A. SEE A2.0 FOR SEATING PLAN AND DETAILS.
B. SEE A7.0 FOR FLOOR FINISHES.
C. SEE A8.0 - A8.1 FOR WALL FINISHES.
D. SEE A7.1 FOR CEILING FINISHES.
GENERAL:
A. DRAWINGS ARE BASED UPON WOOD FRAMING. UTILIZATION OF METAL STUDS, ON
NON - BEARING INTERIOR PARTITIONS, BULKHEADS AND SOFFITS IS ACCEPTABLE.
B. ALL ATTACHMENTS MADE THROUGH E.I.F.S. SHALL BE BUSHED TO PREVENT DAMAGE TO
THE FINISH.
C. ALL PENETRATIONS THROUGH E.I.F.S. SHALL BE SEALED USING MFR'S. APPRQVED
METHOD.
D. REFER TO EXTERIOR ELEVATIONS (SHT. A4.0 -A4.1) FOR EXTERIOR FINISHES, AND ROOM
FINISH SCHEDULE (SHT. A7.2) FOR INTERIOR FINISHES.
E. REFER TO STRUCTURAL DRAWINGS FOR POSTS, SHEARWALL SHEATHING / ANCHORING
AND SILL PLATE REQUIREMENTS (SHTS. THRU __j.
NTS D I FLOOR PLAN NOTES
C
or -ro MIAMI
sulo4 SEC 'Tom
�`1` lProl, L?
FLOOR PLAN 1/4 " =1'-0" 1 A
PATCH STUCCO AS NEEDED.
`- PROTECT KITCHEN EQUIPMENT DURING CONSTRUCTION
ELECTRICAL MAIN SWITCHBOARD. REFER TO ELECT. DWGS.
ERECT DUST BARRIER TO PROTECT KITCHEN DURING CONSTRUCTION.
REPAIR DAMAGED AND PORTIONS OF WALL DEMOED FOR INSPECTION. FINISH
(K) V -0" MIN. FINISH DIMENSION - GC TO FIELD VERIFY. ADJUST WALL AS NEEDED.
CONSTRUCT NEW INTERIOR WALL PER WALL LEGEND. MATCH EXISTING. FINISH
PER SCHEDULE.
KEY NOTES I B
04 C-4
o M
w� N 4
m N O
N w
{Yy N
C m EE
�Z Lu
S O1z
} plg
N W
U
` N N
R
o
N m J
LL
V
11 009
't
N
0)
N
0)
Q
d
z
w
cn
z
w
Q
J
CL
0
H
0
am
O
w
w
w
w
w
H
w
0
08.24.11 PLAN CHANGE -NE)C 2 TEN
®09.23.11 REVISION NO. 4
Zj 11.07.11 REVISION NO. 5
0
_
CONTRACT DATE:
BUILDING TYPE:
PLAN VERSION:
SITE NUMBER:
STORE NUMBER:
04.17.11
M70H
Sep09A
298702
025743
TACO BELL
6310 DIXIE HWY
MIAMI, FL
Q11
1110
Mo!'EIM �
REMODEL
M70H
A1.0
PLOT DATE: 3 -17 -09