Loading...
11-473-007RESTROOM DOORS: BUTTS: 1 1/2 PR BOMMER BB5000, 4 -1/2" x 4 -1/2" LOCK: YALE PB5402LN 626 CLOSER: DORMA 7414 ARP SNB 689 KICKPLATE: STAINLESS STEEL 10" x 34" DOOR STOP: FLOOR STOP - ROCKWOOD 441 CU PUSH PLATE: ROCKWOOD 70F - 8" x 16" PULL PLATE. ROCKWOOD 70C x 107 - 4" x 16" PREFERRED SUPPLIER 0 INTERIOR DOORS, FRAMES & HARDWARE LOCKNFT MIKE MOYNAHAN 100 COURCHELLE DRIVE NICHOLASVILLE, KY 40356 CONTRACT DATE: BUILDING TYPE: PLAN VERSION: SITE NUMBER: STORE NUMBER: EMAIL: CONSTRUCTION@LOCKNET.COM 800 - 887 -4307 FAX: 859- 887 -4958 DOOR HARDWARE SCHEDULE G PUSH PLATE OR HANDLE, WHERE SCHEDULED SIGN WHERE - -1 REQUIRED 0 m KICKPLATE UNDERCUT \ rr DOOR 3/4" \ !� 0 60 TYPICAL NEW INTERIOR WALL: 2x4 WD STUDS (2X6 OR 2X8 WHERE NOTED) AT 16" O.C. W/ 1/2" GYP. BD, SUBSTRATE U.O.N. USE MOISTURE RESISTANT GYP. BD. BEHIND ALL CERAMIC WALL TILE. U.O.N. ACCEPTABLE ALTERNATE: METAL STUDS IN LIEU OF WOOD STUDS. WALL LEGEND NTS I E I 1. LAMINATE DOORS. SEE INTERIOR ELEVATIONS 2. MOUNT DOOR CLOSERS ON RESTROOM OR KITCHEN SIDE ONLY. 3. MOUNT KICKPLATE ON PUSH SIDE ONLY. F. F. 4. MAXIMUM DOOR OPERATING PRESSURE: 5 LBS INTERIOR: 8.5 LBS EXTERIOR MEASURED AT 90 DEGREES TO THE DOOR AT THE STRIKE SIDE EDGE. 5. ADA COMPLIANT ACCESSIBILITY SIGNAGE WHERE REQUIRED (OR AS REQUIRED BY LOCAL JURISDICTION) - (1) MEN; (1) WOMEN 6. RESTROOM SIGN IF REQUIRED. VERIFY LOCAL REQUIREMENTS, 7. FRAMES SHALL BE PAINTED. - DOOR ELEVATIONS NTS F I RESTROOM DOOR GENERAL NOTES DIMENSIONS: A. DIMENSIONS THAT ORIGINATE FROM EXISTING ELEMENTS OF THE BUILDING ARE FROM FACE OF FINISH. ALL OTHER DIMENSIONS ARE TO FACE OF STUD U.O.N. REFER TO FOUNDATION PLAN FOR FACE OF CONC. DIMENSIONS. B. DIMENSIONS NOTED AS "CLEAR" OR "HOLD" ARE MIN. REQ'D. NET CLEARANCE' FROM FACE OF WALL/ WAINSCOT FINISH. VERIFY FINAL EQUIPMENT SIZES W/ VENDOR PRIOR TO INT. WALL FRAMING. WINDOWS / DOORS: A. - SEE SCHEDULE FOR WINDOW AND DOOR TYPES, B, ALL DOOR AND WINDOW OPENING DIMENSIONS ARE TO ROUGH OPENING. FINISH SUBSTRATES: A. PROVIDE 1/2" THICK CEMENTITIOUS BD. FROM FLOOR SLAB TO 12" A.F.F, MIN, IN LIEU OF GYP. BD. AT ALL WALLS EXCEPT SHEARWALL SURFACES, U.Q.N. B. ALL JOINTS, GAPS OR SPACES LEADING TO ALL HOLLOW OR INACCESSIBLE SPACES SHALL BE SEALED WITH "NSF INTERNATIONAL" APPROVED SEALANTS. C. ALL BACK OF HOUSE AND OFFICE WALLS SHALL HAVE 1/2" CDX PLYWOOD SUBSTRATE, DECdFP-N. A. SEE A2.0 FOR SEATING PLAN AND DETAILS. B. SEE A7.0 FOR FLOOR FINISHES. C. SEE A8.0 - A8.1 FOR WALL FINISHES. D. SEE A7.1 FOR CEILING FINISHES. GENERAL: A. DRAWINGS ARE BASED UPON WOOD FRAMING. UTILIZATION OF METAL STUDS, ON NON - BEARING INTERIOR PARTITIONS, BULKHEADS AND SOFFITS IS ACCEPTABLE. B. ALL ATTACHMENTS MADE THROUGH E.I.F.S. SHALL BE BUSHED TO PREVENT DAMAGE TO THE FINISH. C. ALL PENETRATIONS THROUGH E.I.F.S. SHALL BE SEALED USING MFR'S. APPRQVED METHOD. D. REFER TO EXTERIOR ELEVATIONS (SHT. A4.0 -A4.1) FOR EXTERIOR FINISHES, AND ROOM FINISH SCHEDULE (SHT. A7.2) FOR INTERIOR FINISHES. E. REFER TO STRUCTURAL DRAWINGS FOR POSTS, SHEARWALL SHEATHING / ANCHORING AND SILL PLATE REQUIREMENTS (SHTS. THRU __j. NTS D I FLOOR PLAN NOTES C or -ro MIAMI sulo4 SEC 'Tom �`1` lProl, L? FLOOR PLAN 1/4 " =1'-0" 1 A PATCH STUCCO AS NEEDED. `- PROTECT KITCHEN EQUIPMENT DURING CONSTRUCTION ELECTRICAL MAIN SWITCHBOARD. REFER TO ELECT. DWGS. ERECT DUST BARRIER TO PROTECT KITCHEN DURING CONSTRUCTION. REPAIR DAMAGED AND PORTIONS OF WALL DEMOED FOR INSPECTION. FINISH (K) V -0" MIN. FINISH DIMENSION - GC TO FIELD VERIFY. ADJUST WALL AS NEEDED. CONSTRUCT NEW INTERIOR WALL PER WALL LEGEND. MATCH EXISTING. FINISH PER SCHEDULE. KEY NOTES I B 04 C-4 o M w� N 4 m N O N w {Yy N C m EE �Z Lu S O1z } plg N W U ` N N R o N m J LL V 11 009 't N 0) N 0) Q d z w cn z w Q J CL 0 H 0 am O w w w w w H w 0 08.24.11 PLAN CHANGE -NE)C 2 TEN ®09.23.11 REVISION NO. 4 Zj 11.07.11 REVISION NO. 5 0 _ CONTRACT DATE: BUILDING TYPE: PLAN VERSION: SITE NUMBER: STORE NUMBER: 04.17.11 M70H Sep09A 298702 025743 TACO BELL 6310 DIXIE HWY MIAMI, FL Q11 1110 Mo!'EIM � REMODEL M70H A1.0 PLOT DATE: 3 -17 -09