09-412-0282 3 4
1
I I I I I
AFFECT AREA
OF WORK FE]
I — — — — EXT'G. — — — — — — — — —1 — —
EXT'C_ — — — — — — — EXTIG_ — — _ — — EXVG_. WOMEN'S — — — — — — — - 1 I -- — EXAM ROO-M-
- —EXAM ROOM EXAM ROOM H.C. TOILET MIN, 10' -0' SEPARATION
-- — 115 101
118 W1 SCREEN FROM O/A INTAKE I
I I�
\ ❑ I 0
\ 1 PROVIDE /
❑ 1z 1 I I I 1 2'- ro'X2' -(o"
ACCESS
\ 1 HATCH /
L J
1 TYP.)
\
PROVIDE 1 \
Jj
ACCE58 \ \ —71
0XT'Cs.
HATCH (TYP.) \ CORR 8 °x8" /
\ \ 119 I II CFM j
\ L —
L —�. I
I \
PROVIDE -
CORR' �'- 6'x2' -6" 1 EXT'G.
❑ II(o ACCESS 1 I 1 I/ I CORK
HATC;W(TYP.) \ ® 102
\ JANITOR/ /
\ SOILED HOLDING
El 120
\ /
1=X1" G. ALCOVE
EXAM ROOM 121 �\ / / �❑
x�-11144 N6 )RK WITHIN THIS
MQEA UNLESS I I
OT ERWISE NOTED
............ CORR. WAITING AREA / / \ \ WAITING AREA
GENERAL MECHANICAL FLAN
N
SCALE: 1/4' = V -0'
I
\ I
\
:::
:T
'T EXT'G. OFFICE/
ZICAL DOCTOR'S CHARTING
105
NOTES:
I. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS IN FIELD PRIOR TO
COMMENCING WORK - - =�
LEGEND:
EXISTIWz TO REMAIN.
NEW WORK
z
NOTE
CONTRACTOR SHALL 15E RESPONSIBLE FOR PROTECTION OF ANY OPENINGS AND
SECURING ACCESS WITHIN AREA OF WORK ON A DAILY 24 HR 5ASIS.
J
WORK:
5G0�'� OF MECHANICAL
1. PROVIDE PRE -TEST AND BALANCE WITHIN AFFECTED AREAS PRIOR TO COMMENCING
WORK AND PROVIDE CFM'S MEASUREMENTS OF EXISTING SUPPLY DIFFUSERS-
2. PROVIDE NEW EXHAUST FAN AS INDICATED
3. ADJUST CFM'S AS DENOTED IN AFFECT AREA OF WORK
V
COORDINATION NOTE:
CONTRACTOR SHALL COORDINATE AND SCHEDULE THE WORK OF ALL TRADES TO
INSURE THE WORK IS COMPLETED IN A TIMELY MANNER, COMPLYING WITH THE OWNER
AGREEMENT.
oW
"-
ZW
HVAG 5YM5OL5:
z
o
❑ 2'- 0'X2' -0' PERFORATED CEILING
SUPPLY DIFFUSER
�p EXHAUST FAN
❑ 2'- 0'x2' -0' RETURN AIR GRILLE
I 2 3 4 5
ARE RK
® - -- - -- - -- - --� A
-- ------------ r --
41 I I
I
I I
I
I °
- - - --
X
- �-
I
r - - - ❑— - -- -�-
- -- ----------- ---- - - - -f- - - - - ---
KEG' FLAN -FIR51" FLOOR
N N.T.S.
CARLOS DIAZ & ASSOC
ARCHITECTS, PA.
AA 0003014
ARCHITECTURE
INTERIOR DESIGN
1526 N.W. 89th CT
MIAMI, FLORIDA 33172
TEL: 305 599 2888
FAX: 305 599 3885
�C 1991 CARLOS pIAZ A A550G. ARCHITECTS, PA.
The Design and Drawings for thle Project are the
property of the Architect and are protected under
the 19rlght Protection Act.
ARCHITECTURE
eARL05 DIAZ
+S531
1526 N.W. 89th GT.
MIAMI, F1_ 33112
PH: (3o5) 599 -2885
OWNER INFORMATION:
TF-RAHF-N, INC.
A Florida Corporation
6333 SUNSET DR
50UTl -1 MIAMI, FLORIDA
33143
GrENERAL
Mr=CHANIC,4L PLAN,
KEY PLAN,
LEGEND 4 NOTE5
SCALE AS NOTED
091016
0318.09
M1.1
V
z
J
V
oW
"-
ZW
M
z
o
....
.J
>
M
M
o
>
VJ
t
o
W
z
D
Cr-1
D
N
ce.
A�
i.L
r-
0
m
11D
=
�
w O
L)
Z
V)
OWNER INFORMATION:
TF-RAHF-N, INC.
A Florida Corporation
6333 SUNSET DR
50UTl -1 MIAMI, FLORIDA
33143
GrENERAL
Mr=CHANIC,4L PLAN,
KEY PLAN,
LEGEND 4 NOTE5
SCALE AS NOTED
091016
0318.09
M1.1