Loading...
09-412-023PLUMBING ING NOTES: 1. ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH APPLICABLE SECTIONS OF THE 2001 EDITION OF FLORIDA BUILDING CODE, ASTM STANDARD APPLICABLE PLUMBING CODE, COUNTY 4 STATE BOARD OF HEALTH, NF.P.A., STEAM PIPING 4 POWER INSTALLATION 4 0-5.1-1-A. (OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION) REQUIREMENTS. 2. CONTRACTOR SHALL ACQUAINT HIMSELF WITH THESE DOCUMENTS AND THE SITE. ANY OVERSIGHT OF CONFLICTS HEREIN NOT REPORTED IN WRITING TO THE ARCHITECT/ENGINEER PRIOR TO BIDDING, SHALL NOT ENTITLE THE CONTRACTOR TO AN EXTRA. 3. CUTTING AND PATCHING: THE CONTRACTOR SHALL CUT AND PATCH AS REQUIRED FOR REMOVAL, DEMOLITION OR NEW WORK AND PATCH TO MATCH EXISTING. 4. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR (EXCEPT FIRE SPRINKLER PIPING) IN A FIRST CLASS WORKMANLIKE MANNER THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE. 5. REQUIRED INSURANCE SHALL BE PROVIDED BY THE CONTRACTOR FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF WORK. 6. CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, INSPECTIONS, AND TESTS. 1. DRAWINGS ARE DIAGRAMMATIC, DO NOT SCALE FOR THE EXACT LOCATION OF FIXTURES, PIPING, EQUIPMENT, ETC. 8. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERING WITH THE PROCESS OF CONSTRUCTION. 9_ VERIFY LOCATION, SIZE, INVERTS AND ALL EXISTING UTILITIES PRIOR TO BEGINNING CONSTRUCTION. ADVISE ENGINEER OF ANY DISCREPANCIES. 10. SANITARY WASTE PIPE SHALL BE PVC SCHEDULE 40 PIPE WITH DRAINAGE TYPE FITTING OF SAME WEIGHT AND MANUFACTURER AS PIPE_ 11. PROVIDE CLEANOUTS IN ACCORDANCE WITH ALL STATE AND LOCAL CODES. INSTALL CLEANOUT WITH COVER FLUSH TO FINISH SURFACE. 12. DOMESTIC WATER PIPING SHALL BE RIGID COPPER TUBING, TYPE K OR L WITH 150 PSI WSP. SOLDER FITTING CONFORMING TO ANSI B 1522 - 1951. SOLDER SHALL BE TYPE 95 -5. 13. DOMESTIC WATER PIPING SHALL BE 20 PIPE DIAMETERS, BUT NOT LESS THAN 12 INCHES LONG. AIR CHAMBERS SHALL BE PROVIDED AT EACH FIXTURE, GROUP OF FIXTURES, RISERS AND END OF SUPPLY LINES. 14. COPPER PIPING SHALL BE ISOLATED FROM DISSIMILAR METALS, MASONRY OR CONCRETE WITH FOAMED PLASTIC INSULATION_ 15. FURNISH AND INSTALL APPROVED AIR CHAMBERS AT EACH PLUMBING FIXTURE AND PDI APPROVED SHOCK ARRESTERS ON MAIN LINES OR RISERS. 16. DIELECTRIC COUPLINGS ARE REQUIRED BETWEEN ALL DISSIMILAR METALS IN PIPING AND EQUIPMENT CONNECTING To BE SIMILAR EPCD. DAMAGE FOR THE DURATION OF WORK. 11. ISOLATE COPPER PIPE FROM HANGER OR SUPPORTS WITH ISOLATOR PAD (HAIR FELT LINING) SUPER STRUT MODEL C715/16 FILL VOIDS BETWEEN PIPES AND WALL/FLOOR SLEEVES WITH FIRE RATED FOAM, CHASE TECHNOLOGY CORP. - CTC PR -855. 18. CONTRACTOR SHALL GUARANTEE ALL MATERIAL AND WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN (1) YEAR FROM THE DATE OF ACCEPTANCE. CORRECTIONS OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED. 19. PROVIDE 1/2' TRAP PRIMER LINE FOR ALL FLOOR DRAINS FROM THE NEAREST PLUMBING FIXTURE UNLESS OTHERWISE NOTED. 20.PROVIDE ACCESS PANELS WITH CHROME PLATED COVERS FOR ALL CONCEALED VALVES. 21. PROVIDE CHROME PLATED COMBINATION COVERED PLATES AND CLEAN OUT PLUG. FOR ALL WALL CLEAN OUTS JOSAM 58890 SERIES. 22- NO COMBUSTIBLE MATERIALS TO BE USED IN MECHANICAL ROOMS OR IN CLOSET SPACES WHERE USED AS RETURN AIR PLENUM - 23. NO WATER, SANITARY OR DRAINAGE PIPING PERMITTED IN ELECTRICAL EQUIPMENT ROOMS EXCEPT 3/4' WATER STUBBED THROUGH FOR ELECTRICAL GROUND AND SPRINKLER HEAD AND PIPE WITH CONTROL VALVE. 24. PROVIDE SHUT -OFF VALVES FOR EACH FIXTURE WHERE SHOWN AND WHERE REQ'D. FOR PROPER PERFORMANCE OF THE SYSTEM. 25- ALL I IPINa, FITTINGS 4 VALVES FOR STEAM SUPPLY 4 RETURNS ARE TO BE INSTALLED TO COMPLY WITH THE EQUIPMENT SUPPLIER RECOMMENDATION FOR OPERATION. 26. ALL PIPING, FITTINGS 4 VALVES ARE TO BE RATED TO COMPLY WITH A.STM. STANDARDS FOR 150 PSI SWP, 300 PSI WOG DESIGN PRESSURE SYSTEMS- 2-1. HOT WATER TEMPERATURE FOR LAVATORIES SHALL NOT EXCEED 110' F. 28. PRE - MOLDED FI5ER3LASS INSULATION FOR ALL HOT WATER SUPPLY PER FLORIDA BUILDING CODE. ALL INSULATION, JACKETS AND ADHESIVES USED SHALL COMPLY WITH THE REQUIREMENTS OF ASTM E -84 WITH A MAXIMUM FLAME SPREAD RATING OF 25 AND A MAXIMUM SMOKE DEVELOPED/FUEL CONTRIBUTED RATING OF 50. THE INSULATION THICKNESS IN INCHES SHALL BE IN ACCORDANCE WITH THE FOLLOWING TABLE: TABLE- PIPING INSULATION THICKNESS 29. SLEEVE AND OR FIRESTOP ALL PENETRATIONS THROUGH RATED WALLS, CEILINGS AND FLOORS WITH U/L/ LISTED ASSEMBLIES, FIRESTOP ASSEMBLIES SHALL BE EQUAL TO OR EXCEED THE RATING OF THE WALL, CEILING OR FLOOR SEE ARCHITECTURAL DRAWINGS FOR FINAL FINISHES. PIPE SIZE, IN. UP t0 1 1 -1/4 t0 2 2 -1/2 TO 4 5 TO 6 8 4 UP HOT WATER 1 1 1 -1/2 1 -1/2 1 -1/2 NOTE: CONTRACTOR TO VERIFY IN FIELD WATER LINES TO BE RUN WITHIN CEILING OF EXISTING SPACE 4 PROVIDE ALL COST IN BASE BID FOR ALTERATION TO LAYOUT OR MODIFICATIONS TO EXISTING. SL A15 NOTE: CONTRACTOR SHALL SAW GUT EXISTING CONCRETE SLAB AS REQUIRED TO ACCOMMODATE NEW ELECTRICAL MECHANICAL 4 PLUMBING WORK TO BE DONE AND REMOVE DEBRIS FROM SITE. ONCE LATTER WORK HAS BEEN COMPLETED, CONTRACTOR SHALL INFILL NEW TRENCHES AND EXISTING TRENCHES WITHIN SPACE WITH A NEW 4' CONCRETE SLAB (4, 000 PSI) W /6X6, Wl_4xWIA W.WF. OVER VAPOR BARRIER ON WELL COMPACTED FILL WAN AFFECTED AREAS, ALIGN FLUSH WITH EXISTING:. _NOTE: CUTTING AND PATCHING: THE CONTRACTOR SHALL CUT AND PATCH AS REQUIRED FOR REMOVAL, DEMOLITION OR NEW WORK AND PATCH TO MATCH EXISTING. 4 Q EXT'G. EXAM ROOM 114 CORR I 113 III': t i The Deelgn and Drawings for thle Project are the property of the Architect and are protected under, the Copyrlght Protection Act. PLU SING O - -I- F - - -EXt is xT � 4 SANITARYi �-- CONSTRUCTION NOTE EXT'G. G. EXT'G. WOMEN 1 JANITOR/ 1526 N.W. 89th CT. EXAM ROOM EXAM ROOM PREPARE WALL H.G. TOILET LINE (V.I.F.) GD SOILED HOLDING ----- - - -- 115 11� INSTALL NEW LAV 118 SK -3 120 FLOOR DRAIN WITH LAVATORY (P -3) (P -4) -11/2' 1/2' TRAP RESEAL -- - - HOT WATER PIPE CHECK VALVE - HOT WATER PIPE RETURN O PIPING RISE W PIPING DROP - -pQ-- GATE VALVE ' EXT'G. VENT UP 1413- HOSE 515 - AIR CHAMBER Ol TO 2" VTR P 4 T RELIEF PIPE c.o.0- CLEAN OUT W of o SLAB PENETRATION T E INTO EXTIG I- - EXT'G. EXAM ROOM 114 CORR I 113 III': t i The Deelgn and Drawings for thle Project are the property of the Architect and are protected under, the Copyrlght Protection Act. PLU SING TIE INTO EXT'G.- ARCHITECTURE - NEW SANITARY PIPE 11-b CONSTRUCTION NOTE � 9537 1 2' VENT STACK 1526 N.W. 89th CT. GD ----- - - -- NEW VENT PIPE PN: (3�5J 599 -2888 I L� FLOOR DRAIN WITH -- - - COLD WATER PIPE -11/2' 1/2' TRAP RESEAL -- - - HOT WATER PIPE CHECK VALVE - HOT WATER PIPE RETURN O PIPING RISE W PIPING DROP - -pQ-- GATE VALVE ' EXT'G. VENT UP 1413- HOSE 515 - AIR CHAMBER Ol TO 2" VTR P 4 T RELIEF PIPE c.o.0- CLEAN OUT W of o SLAB PENETRATION T E INTO EXTIG 2'V D 2 y Q 3 61 SANITARY LINE F (V 5 q\" - -- - - - - - - V ________ _ _ _ _ _ r - - _ 2'V I ::EZ SK -1 V) GOR I OWNER INFORMATION: I i A Florida Corporation I1 I I 6333 SUNSET Dig SOUTH MIAMI, FLORIDA I 33143 1 1/2 I j SK -1 j 3' 1i II i i i TIE INTO EXT'G COQ, 3' SANITARY LINE F.U.) ( V IF) _ I 2' 11/2' - ° E1 DF lP -5) 1 1/2" -1 lP -1) 3f SANITARY LINE EXT'G. EXAM ROOM 114 CORR I 113 III': t i The Deelgn and Drawings for thle Project are the property of the Architect and are protected under, the Copyrlght Protection Act. PLU SING i ARCHITECTURE - LFJ ALCOVE 121 AREA - ALCOVE ❑ Q CORK REt -IOVE 4 CAP SANITARY LIN 110 CV.LI =.� CORK S 109 I - - - - S I EXT'G. 2" VENT - ------ - - - - -- -t----------- -I EXT'G. O �E IN 2" SANITARY LINE T E T' LOUNGE (V.I.F.) 2" EXT'G. V UP � I TO 2" VTR I 1 1/2' I 1 1 j /---5 S S S S - S S S g l 5K -2 S 1 EXT'e 4" (P -2) - - - I LINE IF�: S S I 1 I f I I I 1 I Q 0 EXT'G. LAY XT'G. MEN'S NURSES EXAM ROOM IE NEW SINK IN TO EXT'G LOUNGE PREPARE WALL (P -3) H.G. TOILET CHARTING 112 STAGKC2 U.J (Y.IFJ 111 INSTALL NEW 108 101 LAVATORY S CO EXT'G. I 4" SANITfIR r- LINE C V.I.F.; SCOPE OF WORK: I. INSTALL NEW MILLWORK WITH(TYP. OF 5) 2. REMOVE 4 CAP EXT'G. SLOPE SINK AND PROVIDE NEW JANITOR'S SINK 3. PROVIDE NEW LAVATORIES IN EXT'G. H/C TOILETS. N SANITARY PLAN SCALE: 1/4'= 1' -0' PLU" 51NG FIXTURE LEGEND AMERICAN STANDARD FIXTURES ARE USED AS REFERENCE, UNLESS OTHERWISE NOTED. EQUIVALENT PRODUCT OF BRIGGS 4 KOHLER ARE ACCEPTABLE. COLOR SHALL BE WHITE UNLESS OTHERWISE NOTED. PROVIDE CHROMIUM PLATED SUPPLIES, TRIMS, STOPS, 4 ESCUTCHEON PLATES FOR ALL FIXTURES, WHETHER INCLUDED ON PLATE NUMBERS OR NOT. WASTE ARMS SHALL BE SCHEDULE 40 PVC. P -1 SINK (SK -1): ELKAY -LRAD 1918/2 W/ FAUCET CHICAGO 2302 -CP, SUPPLIES MCGUIRE H110LK AND TRAP - MCGUIRE 8912. P -2 SINK (5K -2): ELKAY -LRAD 1918/2 W/ FAUCET CHICAGO 2302 -CP, SUPPLIES MCGUIRE H110LK W/ PLASTER TRAP(JOSAM 61030). P -3 LAVATORY (LAY): AMERICAN STANDARD- WALL -HUNG LAVATORY HANDICAPPED ACCESSIBLE *0356.015 LAVATORY W/ CHICAGO CENTER SET FAUCET 0185 -E29VP (WRIST BLADE HANDLES 4 GRID DRAIN). SUPPLIES- MCGUIRE- HIIOI- K.STRAINER/TRAP: MCGUIRE- 155WC/PW 2150 WC. (PROVIDE BACKING AS REQUIRED) P -4 JANITOR SINK (SK -3): CECO 0865 W/ FAUCET 08341 016.002 POLISHED CHROME. P -5 DRINKING FOUNTAIN (DF) OASIS 'N PBAC SL P -6 WATER HAMMER ARRESTER: SPUN CLOSED SEAMLESS COPPER TUBE CHAMBER SEALING A 60 PSIG AIR CHARGE ABOVE A TRIPLE O -RING ACETAL PISTON, O- RINGS, LUBRICATED WITH LONG LIFE APPROVED SILICONE COMPOUND, TO BE PROVIDED WITH MALE, SWEAT END CONNECTION. P-'T WALL CLEANOUT: DURA- COATED CAST IRON, BODY CLEANOUT TEE, WITH GAS, AND WATERTIGHT, TAPERED THREAD PLUG AND ROUND, SMOOTH STAINLESS STEEL WALL ACCESS COVER WITH SECURING SCREW. I I I i'I I EXT'G. EXAM ROOM L -104 V1 101 I I I I I I I I EXT'G. - - - - -- I I I CORK I 102 EXT'G_ EXAM ROOM 103 I I I I EXT'G. WA111 NG AREA 100 I I I I I\ EXT'G. CORR I I �u� I 104 I / \ L'.j MT I I I I i I I I I 1 1 1 1 I I i EX-VCs. EXT'G. OFFICE/ CLERICAL DOCTOR'S CHARTING ❑ I -- -I - - -- 106 - - - - -- _105 -I I I I I NOTE : SANITARY 4 CONDENSATE LINES a 1/4' PER FT. FOR 2' OR SMALLER AND 1 /8' PER FT. FOR 3' L INES AND LARGER (TABLE 906. 1 F.B.C.) 1 2 3 4 5 M 1 -I .. ... ... ".' ...... . ........ '..' . . .'. -r ... ` .. 1:'.: ... ...... -i . :. - -..LL11 - - -1 E L-------- - - - - -- - - -- f -- - - - - -- AREA OF WORK KEY PLAN -FIRST FLOO!;�,y,., _ N N.T.S. CARLOS DIAZ & ASST ARCHITECTS, PA, AA 0003014 ARCHITECTURE INTERIOR DESIGN 1526 N.W. 89th CT MIAMI, FLORIDA 33172 TEL 305 599 2888 FAX: 305 599 3885 © 1991 CARL -05 DIAZ 4 A550C. ARCHITECT5, PA. The Deelgn and Drawings for thle Project are the property of the Architect and are protected under, the Copyrlght Protection Act. PLU SING LEGEND: ARCHITECTURE - NEW SANITARY PIPE 11-b CONSTRUCTION NOTE � 9537 - S EXISTING SANITARY PIPE 1526 N.W. 89th CT. GD ----- - - -- NEW VENT PIPE PN: (3�5J 599 -2888 I L� FLOOR DRAIN WITH -- - - COLD WATER PIPE Z 1/2' TRAP RESEAL -- - - HOT WATER PIPE CHECK VALVE - - - HOT WATER PIPE RETURN O PIPING RISE W PIPING DROP - -pQ-- GATE VALVE 1413- HOSE 515 - AIR CHAMBER Ol 2 R P 4 T RELIEF PIPE c.o.0- CLEAN OUT W of o SLAB PENETRATION CONNECT TO EXT'G Z D N SANITARY PLAN SCALE: 1/4'= 1' -0' PLU" 51NG FIXTURE LEGEND AMERICAN STANDARD FIXTURES ARE USED AS REFERENCE, UNLESS OTHERWISE NOTED. EQUIVALENT PRODUCT OF BRIGGS 4 KOHLER ARE ACCEPTABLE. COLOR SHALL BE WHITE UNLESS OTHERWISE NOTED. PROVIDE CHROMIUM PLATED SUPPLIES, TRIMS, STOPS, 4 ESCUTCHEON PLATES FOR ALL FIXTURES, WHETHER INCLUDED ON PLATE NUMBERS OR NOT. WASTE ARMS SHALL BE SCHEDULE 40 PVC. P -1 SINK (SK -1): ELKAY -LRAD 1918/2 W/ FAUCET CHICAGO 2302 -CP, SUPPLIES MCGUIRE H110LK AND TRAP - MCGUIRE 8912. P -2 SINK (5K -2): ELKAY -LRAD 1918/2 W/ FAUCET CHICAGO 2302 -CP, SUPPLIES MCGUIRE H110LK W/ PLASTER TRAP(JOSAM 61030). P -3 LAVATORY (LAY): AMERICAN STANDARD- WALL -HUNG LAVATORY HANDICAPPED ACCESSIBLE *0356.015 LAVATORY W/ CHICAGO CENTER SET FAUCET 0185 -E29VP (WRIST BLADE HANDLES 4 GRID DRAIN). SUPPLIES- MCGUIRE- HIIOI- K.STRAINER/TRAP: MCGUIRE- 155WC/PW 2150 WC. (PROVIDE BACKING AS REQUIRED) P -4 JANITOR SINK (SK -3): CECO 0865 W/ FAUCET 08341 016.002 POLISHED CHROME. P -5 DRINKING FOUNTAIN (DF) OASIS 'N PBAC SL P -6 WATER HAMMER ARRESTER: SPUN CLOSED SEAMLESS COPPER TUBE CHAMBER SEALING A 60 PSIG AIR CHARGE ABOVE A TRIPLE O -RING ACETAL PISTON, O- RINGS, LUBRICATED WITH LONG LIFE APPROVED SILICONE COMPOUND, TO BE PROVIDED WITH MALE, SWEAT END CONNECTION. P-'T WALL CLEANOUT: DURA- COATED CAST IRON, BODY CLEANOUT TEE, WITH GAS, AND WATERTIGHT, TAPERED THREAD PLUG AND ROUND, SMOOTH STAINLESS STEEL WALL ACCESS COVER WITH SECURING SCREW. I I I i'I I EXT'G. EXAM ROOM L -104 V1 101 I I I I I I I I EXT'G. - - - - -- I I I CORK I 102 EXT'G_ EXAM ROOM 103 I I I I EXT'G. WA111 NG AREA 100 I I I I I\ EXT'G. CORR I I �u� I 104 I / \ L'.j MT I I I I i I I I I 1 1 1 1 I I i EX-VCs. EXT'G. OFFICE/ CLERICAL DOCTOR'S CHARTING ❑ I -- -I - - -- 106 - - - - -- _105 -I I I I I NOTE : SANITARY 4 CONDENSATE LINES a 1/4' PER FT. FOR 2' OR SMALLER AND 1 /8' PER FT. FOR 3' L INES AND LARGER (TABLE 906. 1 F.B.C.) 1 2 3 4 5 M 1 -I .. ... ... ".' ...... . ........ '..' . . .'. -r ... ` .. 1:'.: ... ...... -i . :. - -..LL11 - - -1 E L-------- - - - - -- - - -- f -- - - - - -- AREA OF WORK KEY PLAN -FIRST FLOO!;�,y,., _ N N.T.S. CARLOS DIAZ & ASST ARCHITECTS, PA, AA 0003014 ARCHITECTURE INTERIOR DESIGN 1526 N.W. 89th CT MIAMI, FLORIDA 33172 TEL 305 599 2888 FAX: 305 599 3885 © 1991 CARL -05 DIAZ 4 A550C. ARCHITECT5, PA. The Deelgn and Drawings for thle Project are the property of the Architect and are protected under, the Copyrlght Protection Act. ARCHITECTURE i CARL05 DIAZ � 9537 1526 N.W. 89th CT. MIAMI, FL 33112 PN: (3�5J 599 -2888 I I' Z I II W 'I o `W r M M, O Ol 2 W of o Lu cle Z D Q Cie LLj V ::EZ V) OWNER INFORMATION: Tr=RAHEN, INC. i A Florida Corporation 6333 SUNSET Dig SOUTH MIAMI, FLORIDA 33143 j 1i II i i i u SANITARY PLAN, KEY PLAN, LEGEND, 4 NOTES SCALE AS NOTED PROJECT NO. 091(16' DATE 0308 -09 REVISIONS: SHEET 1.1 2 OF 0