09-412-006I
I
1
L
2 3 4
I I I I
❑O
EXT'G. WOMEN'S
1={C_ TOILET -
ZR
E CT
TO MA I
- PL. LAM. GAB. W/
SHELVES
(SEE Sl -IEEt A51)
CURTAIN TRACK
ABOVE (TYP. FOR
Al EXAM ROOMS)
1(01
— - - - - - o o - - - - - - - - - - - III
0 b
r;XT'G ELECT. I
- - - - - -- -
EXT'G_ '- \ 2' -8' Lu
.D ExAm ROOM
� r EXT'G. PT t0 REMAIN I H.G. DIAM. /1
D \ EXT'G LOBBY
1 i � I I I
EXT'G 1 _ ' �� NO WORK WITHIN TH
_ EXAM ROOM A9.1 1 A9.1 �� _ 2 -O AREA UNLESS
i / OTHERWISE NOT
- - - - --
-- - - - - -- 115 - -- r - _ _- - - - - -- 1i i RR I HOLIL ` / I
EXT'G. CT t0 REMAIN /
2 " r HC- /
30 X 48 CLEAR FLOOR 2, SIGN 119 �\ EXT'G Gt
- - - �3PACE FOR H.C. EXT G GT _ TO REMAIN
PARALLEL APPROACH. �� - - REMAIN - -
(TYP OF 6) i 9 2
rAG
0 2
EXT'G.
EXAM ROOM
Q � 101
EXTG. CT TO REMAIN
I
-------------- - - - - -- --------4------
4'-0" x 1' -0' PL. LAM.
TOP 4 4' -O' x 2' -0'
5OTT0I!1 CAB. SEE PLAN
NOTE 1 (TYP. OF 2) 1 - - - - - -
- - - A N ALI - EQUIPMENT N
/ 9.1 EXT'G.
CORK � 5, - ®, I 120 4. CORK - - - - - -
_ GYP. COLUMN Iib 41 H.G. -v 02 30' 48' CLEAR FLOOR
1 (TYP. 01= 2 EXT'G CT m U �� EXT'G I.T. I EXT'G CT SP E FOR H.C.
TO REMAIN 5 , 3 o Exrcz ROOM P LLEL APPROACH.
8• STAIRS t0 REMAIN YP. OF 2)
114 - --
;�•� ALIGN � I I ExT'Cx_ � - - -
�� ALCOVE �1 EXAM ROOM
A9.1 121 L _ _ _ _ _ _ EXT'G. PNL 'B' 103 0
1 (81M.) 1 EXT'G CT EXT G. CT TO REMAIN
I4' -0' x I' -0' PL. LAM_ TO REMAIN EXt'C -�. i�NL "A"
----------------- �CY� - - --
L - - - - - - J TOP 4 4' -0' x 2' -0" H -C. ACCESSIBLE DF_ I I EXT'G. PHONE
2
BOTTOM cAS. W /SINK Bo,ala3
1 5 CLEAR FLOOR SPACE
SEE PLAN NOTE CORR SEE DTL. 1/A9.1 (30 "x48" MIN.) SPOUT EXT'G.
(TYP. OF 5) WAI ING AREA
113 (TYP.) - BET 36' AFF.
- -- - - - - - -- ----------------
CX-TG. TOXREMAIN (q I I 100 -
a► WAITING AREA I EXT'G. T TO REMAIN 9
REINFORCE HEADER
E M ROOM 122 j ABOVE FOR TV BRACKET. �
114 1^XT'us. CT TO REMA IN I COORDINATE W/ END USER
EXT'G. PT TO REMAIN 5 I (TYP. BOTH SIDES)
I I I
m _ "
-II 5 Il 3 -8 5 I1 it 41-(30
CGLR) ALCOVE
F10 TA 1
- I - - - - - oe EXT'G CT - - - - - -
1 �R� TO REMAIN E� 'G — EXT'G.
CORK 5 - PATCIN�A4D REPAI STAIiaZ CORR.
110 ap WALL AS NEEDE
EXT'G CT u GOB -G ELkv. TO
2 TO REMAIN 109 \ 1 1
EXT'G CT \ ALIGN
EXT'G. t0 REMAIN \ /
EXAM ROOM 1 1 0 ALI 2 EXT-G LOBBY /
112 _ - - - - - �_ - - - - EXT'Cx UPPER GABINET,fi
EXT'G. CT TO REMAII N1 8 NO WORK WITHIN THIS
A9.1 AREA UNLESS
I OTHERWISE NOTED
i EXT'G LOUNGE EXT'G ELECT. EXTIG.
8' -3' 111 I _ _ \ j HARR�TI B / / \ ROOM CLERICAL
EXT I G_ CT t0 REMAIN I ' 10i T
/ / \I I EXT'G. CT TO REMAIN
EXT'G CT /
EXT'G CABINETS 4 SINK ' H.G. D IAM. ' O REMA I
r- TO REMAIN
-- - - �� - - - - - - - --
�0 I I I I
IL I 2 / \
__ri LI
2
lf7 161 O O
e- -
STANDING PL. L.
EXT'G. MEN' M.
SEE ENLARGED PLAN H.G. TOILE COUNTER 4 8'- "X I' -0'
ON SHEET A5.1 (TYP.) 108 PLAN- NQ� (SEE a
EXTG CT
TO REMAIN
FLOOR FLAN
IN
SCALE: 1/4' = 1' -0'
OCCUPANCY COUNT:
OCCUPANCY COUNT PER F.B.C. - 200-1 EDITION - TABLE 1004.1.1
OFFICE AREA: 34W.6 1 PRSN /100 S.F. = 35 PERSONS
MINIMUM CLEAR OPENING OF EXIT DOORS PER TABLE 1005.1:
35 PERSONS X 0.2 IN. EGRESS WIDTH PER PERSON = 'I IN.
2 MEANS OF EGRESS PROVIDED m MIN. 34 IN.
TOTAL= 68 IN.
I1
- —0c
EXT'G. OFFICE/
DOCTOR'S CHARTING
EXT'G. CT TO REMAIN
2 I
z
AGGE55I5IL.ITY NOTE:
1.- ALL WORK SHALL BE PERFORMED TO MEET AND COMPLY WITH
FLORIDA BUILDING CODE - 200-1 EDITION CHAPTER 11 FLORIDA
ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION.
2 SECTION 11- 4.1.6. 4 11- 4.1.8. WILL BE ADHERED t0 IF SO REQUIRED
RATED PENETRATION NOTE:
SEAL ALL PENETRATIONS THRU CONCRETE FIRE RATED PARTITIONS
WITH STI FIRESTOP SEALANT OR EQ. TO MEET UL SYSTEM
NO. W -J -1098 4 C -A -J -5138 FOR METAL PIPE. INSTALL AS PER
MANUFACTURER RECOMMENDATION FOR 1, 2, 3, 4 4 HR RATINGS -
(TYPICAL). SEE DETAILS ON BHT_ A92
RATED PENETRATION NOTE:
SEAL ALL PENETRATIONS THRU GYPSUM WALL FIRE RATED PARTITIONS
WITH STI FIRESTOP SEALANT OR EQ. TO MEET UL SYSTEM
NO_ WL -1222 FOR METAL PIPE. INSTALL AS PER MANUFACTURER'S
RECOMMENDATIONS FOR 1, 2, 3, 4 4 HR RATINGS. (TYPICAL).
SEE DETAILS ON BHT. A92
RATED PENETRATION NOTE:
SfFAL ALL PENETRATIONS TPR1 GYPSUM WALL FIRE R4TI =P PARTITIONS
WITH STI FIRESTOP SEALANT OR EQ. TO MEET UL SYSTEM NO. W -L -2188
FOR PLASTIC PIPE. INSTALL AS PER MANUFACTURER'S
RECOMMENDATIONS FOR I, 2, 3, 4 4 HR RATINGS. (TYPICAL)_ SEE DETAILS
ON BHT. A9.2 -
5cOf=r= OF WORK:
- INSTALL NEW CURTAINS AND TRACKS IN EXISTING EXAM ROOMS.
- PROVIDE NEW LOW PARTITION IN WAITING AREA.
- PROVIDE 5 NEW CABINETS WITH SINK 4 3 WITHOUT.
- PROVIDE PLASTER TRAP FOR THE SINK IN EXAM ROOM +'112.
- MODIFY EXT'G BATHROOMS TO COMPLY WITH AD.A. REQUIREMENTS
- ADJUST EXt'G GYP. BD. CEILING AROUND TOILET AREA t0 REFLECT NEW
LAYOUT. TOUGH UP PAINT AS REQUIRED TO MATCH EXISTING.
- RELOCATION OF SOME EXISTING LIGHTS-
-NEW PAINT IN EXISTING WALLS AND LOW PARTITION.
- REPAIR OF FLOOR AS REQUIRED BY PLUMBING WORK
-NEW ELECTRICAL AND DATA OUTLETS AS REQUIRED.
- REPLACE ALL EXISTING HARDWARE WITH ADA/5APTIv-T STANDARDS.
-PRO IDE NEW EXHAUST FAN IN SOILED HOLDING ROOM.
- PROVID NEW SINKS IN SOILED OLOING ROOM_
- PROVIDE NE H -LOW DR KING FOUNTAIN.
- PROVIDE NEW EMERGENCY LIGHTS AS REQUIRED.
- ADJUST EXISTING FIRE ALARM AS REQUIRED,
- REINFORCE EXT'G WALLS FOR 2 OVERHEAD FLAT SCREEN TV'S 4 CABINETS_
PARTITION TYPES:
The Deelgn and Drawings for thla Project are the
property of the Archltect and are protected under
EXT'G. INTERIOR GYP. 13RD. PARTITION. PATCH AND REPAIR AS REQUIRED t0
I I
-
REQUIRED FIRE RATING,.
0
TO RECEIVE NEW SCHEDULED FINISH. (SEE BHT. A2.2). MAINTAIN REQUIRED FIRE
RATING-
NON-LOAD BEARING PARTITION TO MATCH EXT'G. GYPSUM WALLBOARD EACH
SIDE ON 3 5/8' (24 GA) MTL. STUDS AT 24' O.C_ TO UNDERSIDE OF STRUCTURE.
FINISH TO MATCH EXT'G. ALIGN WITH ADJACENT WALLS.
INFILL OPENING :CONSISTING OF 3%' (22 GA) MTL. STUDS AT 24' O.C. W/ 5/8' GYP.
cq
I
I
,
;
0 2
EXT'G.
EXAM ROOM
Q � 101
EXTG. CT TO REMAIN
I
-------------- - - - - -- --------4------
4'-0" x 1' -0' PL. LAM.
TOP 4 4' -O' x 2' -0'
5OTT0I!1 CAB. SEE PLAN
NOTE 1 (TYP. OF 2) 1 - - - - - -
- - - A N ALI - EQUIPMENT N
/ 9.1 EXT'G.
CORK � 5, - ®, I 120 4. CORK - - - - - -
_ GYP. COLUMN Iib 41 H.G. -v 02 30' 48' CLEAR FLOOR
1 (TYP. 01= 2 EXT'G CT m U �� EXT'G I.T. I EXT'G CT SP E FOR H.C.
TO REMAIN 5 , 3 o Exrcz ROOM P LLEL APPROACH.
8• STAIRS t0 REMAIN YP. OF 2)
114 - --
;�•� ALIGN � I I ExT'Cx_ � - - -
�� ALCOVE �1 EXAM ROOM
A9.1 121 L _ _ _ _ _ _ EXT'G. PNL 'B' 103 0
1 (81M.) 1 EXT'G CT EXT G. CT TO REMAIN
I4' -0' x I' -0' PL. LAM_ TO REMAIN EXt'C -�. i�NL "A"
----------------- �CY� - - --
L - - - - - - J TOP 4 4' -0' x 2' -0" H -C. ACCESSIBLE DF_ I I EXT'G. PHONE
2
BOTTOM cAS. W /SINK Bo,ala3
1 5 CLEAR FLOOR SPACE
SEE PLAN NOTE CORR SEE DTL. 1/A9.1 (30 "x48" MIN.) SPOUT EXT'G.
(TYP. OF 5) WAI ING AREA
113 (TYP.) - BET 36' AFF.
- -- - - - - - -- ----------------
CX-TG. TOXREMAIN (q I I 100 -
a► WAITING AREA I EXT'G. T TO REMAIN 9
REINFORCE HEADER
E M ROOM 122 j ABOVE FOR TV BRACKET. �
114 1^XT'us. CT TO REMA IN I COORDINATE W/ END USER
EXT'G. PT TO REMAIN 5 I (TYP. BOTH SIDES)
I I I
m _ "
-II 5 Il 3 -8 5 I1 it 41-(30
CGLR) ALCOVE
F10 TA 1
- I - - - - - oe EXT'G CT - - - - - -
1 �R� TO REMAIN E� 'G — EXT'G.
CORK 5 - PATCIN�A4D REPAI STAIiaZ CORR.
110 ap WALL AS NEEDE
EXT'G CT u GOB -G ELkv. TO
2 TO REMAIN 109 \ 1 1
EXT'G CT \ ALIGN
EXT'G. t0 REMAIN \ /
EXAM ROOM 1 1 0 ALI 2 EXT-G LOBBY /
112 _ - - - - - �_ - - - - EXT'Cx UPPER GABINET,fi
EXT'G. CT TO REMAII N1 8 NO WORK WITHIN THIS
A9.1 AREA UNLESS
I OTHERWISE NOTED
i EXT'G LOUNGE EXT'G ELECT. EXTIG.
8' -3' 111 I _ _ \ j HARR�TI B / / \ ROOM CLERICAL
EXT I G_ CT t0 REMAIN I ' 10i T
/ / \I I EXT'G. CT TO REMAIN
EXT'G CT /
EXT'G CABINETS 4 SINK ' H.G. D IAM. ' O REMA I
r- TO REMAIN
-- - - �� - - - - - - - --
�0 I I I I
IL I 2 / \
__ri LI
2
lf7 161 O O
e- -
STANDING PL. L.
EXT'G. MEN' M.
SEE ENLARGED PLAN H.G. TOILE COUNTER 4 8'- "X I' -0'
ON SHEET A5.1 (TYP.) 108 PLAN- NQ� (SEE a
EXTG CT
TO REMAIN
FLOOR FLAN
IN
SCALE: 1/4' = 1' -0'
OCCUPANCY COUNT:
OCCUPANCY COUNT PER F.B.C. - 200-1 EDITION - TABLE 1004.1.1
OFFICE AREA: 34W.6 1 PRSN /100 S.F. = 35 PERSONS
MINIMUM CLEAR OPENING OF EXIT DOORS PER TABLE 1005.1:
35 PERSONS X 0.2 IN. EGRESS WIDTH PER PERSON = 'I IN.
2 MEANS OF EGRESS PROVIDED m MIN. 34 IN.
TOTAL= 68 IN.
I1
- —0c
EXT'G. OFFICE/
DOCTOR'S CHARTING
EXT'G. CT TO REMAIN
2 I
z
AGGE55I5IL.ITY NOTE:
1.- ALL WORK SHALL BE PERFORMED TO MEET AND COMPLY WITH
FLORIDA BUILDING CODE - 200-1 EDITION CHAPTER 11 FLORIDA
ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION.
2 SECTION 11- 4.1.6. 4 11- 4.1.8. WILL BE ADHERED t0 IF SO REQUIRED
RATED PENETRATION NOTE:
SEAL ALL PENETRATIONS THRU CONCRETE FIRE RATED PARTITIONS
WITH STI FIRESTOP SEALANT OR EQ. TO MEET UL SYSTEM
NO. W -J -1098 4 C -A -J -5138 FOR METAL PIPE. INSTALL AS PER
MANUFACTURER RECOMMENDATION FOR 1, 2, 3, 4 4 HR RATINGS -
(TYPICAL). SEE DETAILS ON BHT_ A92
RATED PENETRATION NOTE:
SEAL ALL PENETRATIONS THRU GYPSUM WALL FIRE RATED PARTITIONS
WITH STI FIRESTOP SEALANT OR EQ. TO MEET UL SYSTEM
NO_ WL -1222 FOR METAL PIPE. INSTALL AS PER MANUFACTURER'S
RECOMMENDATIONS FOR 1, 2, 3, 4 4 HR RATINGS. (TYPICAL).
SEE DETAILS ON BHT. A92
RATED PENETRATION NOTE:
SfFAL ALL PENETRATIONS TPR1 GYPSUM WALL FIRE R4TI =P PARTITIONS
WITH STI FIRESTOP SEALANT OR EQ. TO MEET UL SYSTEM NO. W -L -2188
FOR PLASTIC PIPE. INSTALL AS PER MANUFACTURER'S
RECOMMENDATIONS FOR I, 2, 3, 4 4 HR RATINGS. (TYPICAL)_ SEE DETAILS
ON BHT. A9.2 -
5cOf=r= OF WORK:
- INSTALL NEW CURTAINS AND TRACKS IN EXISTING EXAM ROOMS.
- PROVIDE NEW LOW PARTITION IN WAITING AREA.
- PROVIDE 5 NEW CABINETS WITH SINK 4 3 WITHOUT.
- PROVIDE PLASTER TRAP FOR THE SINK IN EXAM ROOM +'112.
- MODIFY EXT'G BATHROOMS TO COMPLY WITH AD.A. REQUIREMENTS
- ADJUST EXt'G GYP. BD. CEILING AROUND TOILET AREA t0 REFLECT NEW
LAYOUT. TOUGH UP PAINT AS REQUIRED TO MATCH EXISTING.
- RELOCATION OF SOME EXISTING LIGHTS-
-NEW PAINT IN EXISTING WALLS AND LOW PARTITION.
- REPAIR OF FLOOR AS REQUIRED BY PLUMBING WORK
-NEW ELECTRICAL AND DATA OUTLETS AS REQUIRED.
- REPLACE ALL EXISTING HARDWARE WITH ADA/5APTIv-T STANDARDS.
-PRO IDE NEW EXHAUST FAN IN SOILED HOLDING ROOM.
- PROVID NEW SINKS IN SOILED OLOING ROOM_
- PROVIDE NE H -LOW DR KING FOUNTAIN.
- PROVIDE NEW EMERGENCY LIGHTS AS REQUIRED.
- ADJUST EXISTING FIRE ALARM AS REQUIRED,
- REINFORCE EXT'G WALLS FOR 2 OVERHEAD FLAT SCREEN TV'S 4 CABINETS_
PARTITION TYPES:
The Deelgn and Drawings for thla Project are the
property of the Archltect and are protected under
EXT'G. INTERIOR GYP. 13RD. PARTITION. PATCH AND REPAIR AS REQUIRED t0
ACCOMMOpATE NEW WORK 4 fRrtC1=1VE N1=W SCHEDULEp FINISH. MAINTAIN 1=XVCF
REQUIRED FIRE RATING,.
EXISTING G.M.U. WALL TO REMAIN. PATCH, REPAIR 4 PREPARE AS REQUIRED
TO RECEIVE NEW SCHEDULED FINISH. (SEE BHT. A2.2). MAINTAIN REQUIRED FIRE
RATING-
NON-LOAD BEARING PARTITION TO MATCH EXT'G. GYPSUM WALLBOARD EACH
SIDE ON 3 5/8' (24 GA) MTL. STUDS AT 24' O.C_ TO UNDERSIDE OF STRUCTURE.
FINISH TO MATCH EXT'G. ALIGN WITH ADJACENT WALLS.
INFILL OPENING :CONSISTING OF 3%' (22 GA) MTL. STUDS AT 24' O.C. W/ 5/8' GYP.
BRD. EA. SIDE, IN COMPLIANCE W/ UL. ASSEMBLY •U465. TO MATCH EXT -G.
CORRIDOR WALL. PATCH, REPAIR AND ALIGN EA, SIDE WITH EXT'G ADJACENT
WALLS.
�5
42' HIGH PARTITION WITH 5/8' GYPSUM WALL BOARD EACH SIDE ON 3 -5/8' (16
GA) MTL. STUDS 0 24' O.G. COORDINATE WITH BAPTIST INTERIOR DESIGN
DEPARTMENT FOR FINISHES. (REFER TO DET. 1/A9.1)
5/8" GYP. BD. ON EXTERIOR SIDE OF 3 -5/8" MTL. STUDS (24 GA) AT 24'
O.C. TO UNDERSIDE OF STRUCTURE ABOVE TO MATCH EXT'G WALLS.
LEGEND:
EXISTING PARTITION
Giii'TlTlli�Tl NEW PARTITION
F.E. FIRE EXTINGUISHER
•
NOTE:
CONTRACTOR IS TO VERIFY ALL DIMENSIONS IN FIELD, PRIOR TO ALL NEW CONSTRUCTION.
PLAN NOTE:
1O PROVIDE FIRE TREATED 2'X4' WOOD BACKING ALONG FULL LENGTH OF METAL STUDS
AT SPACING INDICATED FOR PARTITION TYPE (SEE DETAIL b /A9 -1),
CARLOS DIAZ & ASSOC,
ARCHITECTS, P.A.
AA 0003014
ARCHITECTURE
INTERIOR DESIGN
1526 N.W. 89th CT
MIAMI, FLORIDA 33172
TEL: 305 599 2888
FAX: 305 599 3885
gC 1991 CARLOS DIAZ 4 ASSOC- ARCHITECTS, PA.
The Deelgn and Drawings for thla Project are the
property of the Archltect and are protected under
the Ccpyrlght Protection Act.
ARCHITECTURE
CARLOS DIAZ
0 9531
1526 N.W. 89th CT.
MIAMI, FL 33112
PH: (305) 599 -2888
U
z
V
O
L LJ
L'-
Z
v
Z
O
J
w
�
M
�
F=
p
°
W
I__
ce
g
LU
oC
Q
Cie
rn
D
°
LU
V
Z
OWNER INFORMATION:
TER HF-N, INC-
A Florida Corporation
6333 SUNSET DR
SOUTH MIAMI, FLORIDA
33143
1 2 3 4 5 6
D
—I .......... ... .... - --
s' ......
....... .... ..............
.......... ... .. G
r - :. �X� - - -�i
- -II- ---- - - - - -- - -' Fee] ® IL L ---------
AREA OF WORK F
p
KEY PLAN -FIRST FLOOR,.
Nr
N.T.S.
FLOOR PLAN,
iKEY PL,4N
L LEGEND 4 NOTES
SCALE AS NOTED
PROJECT NO, 091016
DATE 03 -1 8-09
REVISIONS:
0 FIRE DEPT. COl" r I.
REV. 4 -01 -09