09-412-004GENERAL DEMOLITION NOTES: 1.- THIS DRAWING IS ONLY TO ASSIST IN SHOWING THE SCOPE OF DEMOLITION WORK AND IS NOT INTENDED TO INDICATE ALL DEMOLITION. CONTRACTOR SHALL REMOVE ALL EXISTING ITEMS AS REQUIRED TO COMPLETE THE JOB. 2.- NOT ALL ITEMS TO BE DEMOLISHED ARE SHOWN ON THE PLAN. CONTRACTOR SHALL BE RESPONSIBLE FOR PERFORMING A WALK -THRU OF THE PROJECT W/ THE INTENT OF IDENTIFYING POSSIBLE ITEMS, NOT OR INCORRECTLY ADDRESSED, WHICH REQUIRE REMOVAL AND /OR RELOCATION. 3.- GENERAL CONTRACTOR TO PROVIDE PERMITS AND NOTICES AUTHORIZING DEMOLITION. 4.- CONTRACTOR SHALL COORDINATE DEMOLITION WORK WITH ADMINISTRATION. PRIOR TO START OF DEMOLITION WORK CONTRACTOR SHALL NOTIFY ADMINISTRATION OF INTENT TO START AND PROVIDE SUFFICIENT ADVANCE NOTICE FOR APPROVAL. 5.- CUT, REMOVE, PATCH, ALTER AND REFINISH EXISTING CONSTRUCTION AS RESULT OF DEMOLITION AND AS REQUIRED TO LEAVE WORK COMPLETE AND IN SATISFACTORY CONDITION. b.- PROVIDE SAFETY FEATURES DURING WORK AS REQUIRED BY SPECIFICATIONS, APPLICABLE CODES, RULES AND REGULATIONS. 1.- GENERAL CONTRACTOR SHALL CEASE OPERATIONS AND NOTIFY THE ARCHITECT / ENGINEER IMMEDIATELY IF SAFETY OF STRUCTURE APPEARS TO BE ENDANGERED. TAKE PRECAUTIONS TO PROPERLY SUPPORT STRUCTURE. DO NOT RESUME OPERATION UNTIL SAFETY IS RESTORED. a.- GENERAL CONTRACTOR SHALL DEMOLISH, IN AN ORDERLY AND CAREFUL MANNER, AS REQUIRED TO ACCOMMODATE NEW WORK, INCLUDING THAT REQUIRED FOR CONNECTION TO THE EXISTING BUILDING. PROTECT EXISTING FOUNDATIONS AND SUPPORTING STRUCTURAL MEMBERS. 9.- CONTRACTOR SHALL INSPECT CEILINGS AND CHASES TO ASSURE PROPER IDENTIFICATION OF UTILITIES (MECHANICAL, PLUMBING AND /OR ELECTRICAL) 10.- PATCH AND REPAIR ALL EXISTING SURFACES DAMAGED BY DEMOLITION AND /OR NEW WORK AS REQUIRED TO MATCH ADJACENT SURFACES AND /OR AS REQUIRED FOR NEW SCHEDULED FINISHES. 11: ALL DEMOLITION IS DENOTED BY BROKEN LINES. 12.- GENERAL CONTRACTOR SHALL PERFORM DEMOLITION IN ACCORDANCE WITH APPLICABLE AUTHORITIES HAVING JURISDICTION. PREPARE EXISTING CONCRETE SLAB AS REQUIRED BY GRINDING AND /OR LEVELING (WITH GYP -CRETE 2000 OR OR APPROVED 13 EQUAL, AS PER MANUFACTURER SPECIFICATIONS AS REQUIRED TO RECEIVE NEW SCHEDULED FLOORING MATERIAL. 14.- FIXTURES, DOORS AND FRAMES, ETC. TO BE REMOVED SHALL BE COORDINATED WITH THE OWNER FOR DESTINATION OF ALL EXISTING EQUIPMENT. 15.- GENERAL CONTRACTOR SHALL REMOVE FROM SITE, CONTAMINATED, VERMIN INFESTED OR DANGEROUS MATERIALS ENCOUNTERED AND DISPOSE OF BY SAFE MEANS SO AS NOT TO ENDANGER HEALTH OR WORKERS AND PUBLIC. 16.- ASBESTOS SURVEY TO BE PROVIDED BY OWNER 11.- ASBESTOS ABATEMENT BY OWNER GENERAL RAL D E rOL I T I ON LEGEND: OREMOVE EXISTING FLOORING IN AREAS AFFECTED BY DEMOLIITON, INCLUDING APPLICABLE ADHESIVES, ANY TRANS. STRIP AND WALL BASES, AND REPAIR TO MATCH EXISTING. OEXISTING WALLS TO BE REMOVED AS INDICATED BY DASHED LINES. PATCH AND REPAIR AS NEEDED. SEE SHT. A2.1 FOR NEW LAYOUT. OEXISTING DOOR 4 FRAME TO BE REMOVED AS INDICATED BY DASHED LINES. SEE SHT. A2.1, FOR NEW LAYOUT. OEXISTING WALL AND WOOD FRAME TO BE REMOVED AS INDICATED BY DASHED LINES. PATCH AND REPAIR AS NEEDED. SEE SHT. A2.1 FOR NEW LAYOUT. O5 REMOVE EXISTING COMPUTER, PHONE COMMUNICATION, SECURITY DEVICES 4 LOW VOLTAGE WIRING, ELECTRICAL LIGHT SWITCHES, J- BOXES, AND FLOOR STUB -UPS WITH THEIR RESPECTIVE CONDUIT AND WIRING BACK TO THEIR RESPECTIVE DISTRIBUTION PANEL OR ELECTRICAL PANEL AND DENOTE ,AVAILABLE BREAKERS ON EXISTING PANELS IN PARTITIONS AND CEILINGS WHICH ARE BEING REMOVED. RELOCATE IF INDICATED. SEE SHT. E2.1 FOR SCOPE OF WORK O6 REMOVE AND DISPOSE EXISTING MILLWORK AS INDICATED BY DASHED LINES. SEE SHTS. A2.1 4 A5.1 FOR NEW PLANS, ELEVATIONS AND DETAILS. OEXISTING DRINKING FOUNTAIN 4 ACCESSORIES TO BE REMOVED AND CAPPED. SEE PLUMBING SHTS. FOR NEW SCOPE OF WORK OEXISTING JANITOR'S CLOSET TO BE REMOVED AND CAPPED. SEE PLUMBING SHTS. FOR NEW SCOPE OF WORK, OEXISTING LAVATORY TO BE REMOVED AND REPLACED. SEE PLUMBING SHTS. FOR NEW SCOPE OF WORK 10 PORTIONS OF EXT'G DRYWALL CEILING: TO BE REMOVED TO ACCOMMODATE NEW WORK. SEE SHTS. Aral 4 A2.1 FOR NEW SCOPE OF WORK 11 PATCH 4 REPAIR EXT'G GYP. BD. CEILING AS REQUIRED. EXISTING LIGHTS TO BE REMOVED AND RELOCATED. RE -LAMP AND 12 CLEAN FOR AN 'AS NEW CONDITION' LOOK - FOR SCOPE OF WORK REFER TO SHT. E1.1 FOR NEW LOCATION. 13 EXISTING LIGHTS TO REMAIN. RELAMP AND CLEAN FOR AN 'AS NEW' CONDITION LOOK- REMOVE EXT'G 2' -0' GRAB BAR AND REPLACE WITH V -0' GRAB BAR SEE SHT. A5.1 FOR HTS. REMOVE AND RELOCATE BATTERY PACK EMERGENCY LIGHTS. SEE SHT. E1.1 FOR NEW LOCATION. Q 4 _1 - t L— -1— — — — — — — — — — _ — -- — -- — — — r' SLA5 NOTE: CONTRACTOR SHALL SAW CUT EXISTING CONCRETE SLAB AS REQUIRED TO ACCOMMODATE NEW ELECTRICAL'_ MECHANICAL 4 PLUMBING WORK TO BE DONE AND REMOVE DEBRIS FROM SITE. ONCE LATTER WORK HAS BEEN COMPLETED, CONTRACTOR SHALL INFILL NEW TRENCHES AND EXISTING TRENCHES WITHIN SPACE WITH A NEW 4' CONCRETE SLAB (4, 000 PSI) W /6Xb, W1.4xWIA W.W.F. OVER VAPOR BARRIER ON WELL COMPACTED FILL WAN AFFECTED AREAS, ALIGN FLUSH WITH EXISTING. N DEMOLITION CEILING FLAN SCALE: 1/4' = 1' -0' NOTE: 1.- CONTRACTOR SHALL LOCATE AFFECTED J- BOXES, FOR POWER AND TELEPHONE. MODIFY AS REQUIRED FOR NEW WORK WITHOUT DISTURBING ADJACENT TENANTS. IF CONTRACTOR MUST DISCONNECT OTHER TENANT'S POWER SUPPLY, TELEPHONE, OR OTHER ELECTRIC CIRCUITRY TO ACCOMPLISH WORK, HE IS TO COORDINATE WITH LANDLORD'S REPRESENTATIVE AS TO WHEN WORK CAN BE PERFORMED. CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR ANY DAMAGES, TENANT COMPLAINTS THAT OCCUR AS A RESULT OF FAILURE TO COMPLY WITH THIS REQUIREMENT. 2.- ALL DEMOLITION TO COMPLY WITH F.B.G. 2001 EDITION - SECTION 3401.1 AND F.B.G. EXISTING BUILDING 2001 EDITION- SECTION 1403. NOTE: CONTRACTOR SHALL TEMPORARILY SECURE ALL EXT'G LIGHT FIXTURES, EXIT SIGNS, FIRE ALARM, ETC. TO REMAIN DURING THE REMOVAL OF EXISTING CEILING AND REINSTALLATION. REINSTALL AND REFINISH ALL ITEMS. SEE ADDITIONAL SCOPE OF WORK WITHIN ELECTRICAL DRAWINGS. New LEGEND: EXISTING TO REMAIN F-- - -- L--------- EXISTING TO BE DEMOLISHED NOTE: ALL WORK SHALL BE PERFORMED TO MEET AND COMPLY WITH FLA. BUILDING CODE -2001 EDITION CHAPTER 11 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION. - -O - -o - -O CITY OF SOUTH MIAMI - BUILT-)ING DEPT. s,rRUGTURA1_, Pr.TIn,m APPROVED 8 4R�� {' - -- - A . E3 ...... �'...,.. ........:. . x ..'.'.'.'.' — - - ... ........' - -�_1 E AREA OF WORK N KEY PLAN -RR5T FL N.T.S. CARLOS DIAZ & ASSOC ARCHITECTS, PA AA 0003014 ARCHITECTURE INTERIOR DESIGN 1526 N.W. 89th CT MIAMI, FLORIDA 33172 TEL 305 599 2888 FAX: 305 599 3885 © 199] CARL05 DIAZ 4 A550G. ARCHITECTS, P-A, The property Deelgrn and Drawinge for thI8 Project are the of the Architect and are protected under the Copyright Protection Act. ARCHITECTURE CARLOS D IAZ • 9531 1526 N.W. 59th GT. MIAMI, FL 33112 PH: (305)599 -2353 z ter■ L) C2 W ® M v O 0111= w M r7 F— 13L Q 0 2 W o N tA w Z V) D O N ° Z) F`_- V Z_ OWNER INFORMATION: TERAHEN, ING. A Florida Corporation 6333 SUNSET DR SOUTH MIAMI, FLORIDA 33143 DEMOLITION REFLECTED GE IL INCA PLAN, <r=Y PLAN, LEGEND 4 NOTES SCALE AS NOTED PROJECT NO. 091016 DATE 03 -16-09 REVISIONS: SHEET A1.3 r OF 20