09-412-003GENERAL D MOL ITION NOTF.S:
I.— THIS DRAWING IS ON! °Y TO ASSIST IN SHOWING THE SCOPE OF
ayD IS NOT INTENDED TO INDICATE ALL
DEMOLITION WORK PACTOR SHALL REMOVE ALL EXISTING ITEMS AS
DEMOLITION. GONTR"' ETE THE JOB.
REQUIRED TO COMPL
2: NOT ALL ITEMS TO 0 DEMOLISHED ARE SHOWN ON THE PLAN.
CONTRACTOR SHALL BE RESPONSIBLE FOR PERFORMING A
WALK -THRU OF THE PROJECT W/ THE INTENT OF IDENTIFYING
POSSIBLE ITEMS, NOT OR INCORRECTLY ADDRESSED, WHICH
REQUIRE REMOVAL AND /OR RELOCATION.
3.- GENERAL CONTRACTOR TO PROVIDE PERMITS AND NOTICES
AUTHORIZM DEMOLITION.
4.- CONTRACTOR SHALL COORDINATE DEMOLITION WORK WITH
ADMINISTRATION. PRIOR TO START OF DEMOLITION WORK
CONTRACTOR SHALL NOTIFY ADMINISTRATION OF INTENT TO START
AND PROVIDE SUFFICIENT ADVANCE NOTICE FOR APPROVAL.
- CUT, REMOVE, PATCH, ALTER AND REFINISH EXISTING
CONSTRUCTION AS RESULT OF DEMOLITION AND AS REQUIRED
TO LEAVE WORK COMPLETE AND IN SATISFACTORY CONDITION.
6.- PROVIDE SAFETY FEATURES DURING WORK AS REQUIRED BY
SPECIFICATIONS, APPLICABLE CODES, RULES AND REGULATIONS.
-1.- GENERAL CONTRACTOR SHALL CEASE OPERATIONS AND
NOTIFY THE ARCHITECT / ENGINEER IMMEDIATELY IF SAFETY OF
STRUCTURE APPEARS TO BE ENDANGERED. TAKE PRECAUTIONS
TO PROPERLY SUPPORT STRUCTURE. DO NOT RESUME
OPERATION UNTIL SAFETY IS RESTORED_
8- GENERAL CONTRACTOR SHALL DEMOLISH, IN AN ORDERLY AND
CAREFUL MANNER, AS REQUIRED TO ACCOMMODATE NEW WORK,
INCLUDING THAT REQUIRED FOR CONNECTION TO THE EXISTING
BUILDING. PROTECT EXISTING FOUNDATIONS AND SUPPORTING
STRUCTURAL MEMBERS.
g,- CONTRACTOR SHALL INSPECT CEILINGS AND CHASES TO ASSURE
PROPER IDENTIFICATION OF UTILITIES (MECHANICAL, PLUMBING
AND /OR ELECTRICAL).
10.- PATCH AND REPAIR ALL EXISTING SURFACES DAMAGED BY
DEMOLITION AND /OR NEW WORK AS REQUIRED TO MATCH ADJACENT
SUFa=ACES AND /OR AS REQUIRED FOR NEW SCHEDULED FINISHES.
11.- ALL DEMOLITION IS DENOTED BY BROKEN LINES.
12.- GENERAL CONTRACTOR SHALL PERFORM DEMOLITION IN
ACCORDANCE WITH APPLICABLE AUTHORITIES HAVING JURISDICTION.
PREPARE EXISTING CONCRETE SLAB AS REQUIRED BY GRINDING
AND /OR LEVELING (WITH GYP -CRETE 2000 OR OR APPROVED
13.- EQUAL, AS PER MANUFACTURER SPECIFICATIONS AS REQUIRED TO
RECEIVE NEW SCHEDULED FLOORING MATERIAL.
14.- FIXTURES, DOORS AND FRAMES, ETC. TO BE REMOVED SHALL ESE
COORDINATED WITH THE OWNER FOR DESTINATION OF ALL EXISTING
EQUIPMENT.
GENERAL CONTRACTOR SHALL REMOVE FROM SITE, CONTAMINATED,
VEWIN INFESTED OR DANGEROUS MATERIALS ENCOUNTERED AND
DISPOSE OF BY SAFE MEANS SO AS NOT TO ENDANGER HEALTH OR
WORKERS AND PUBLIC.
I6 - ASBESTOS SURVEY TO BE PROVIDED BY OWNER
I -L- ASBESTOS ABATEMENT BY OWNER GENERAL DEMOLITION LEGEND:
OREMOVE EXISTING FLOORING IN AREAS AFFECTED BY DEMOLITION,
INCLUDING APPLICABLE ADHESIVES, ANY TRANS. STRIP AND WALL
BASES, AND REPAIR TO MATCH EXISTING.
OEXISTING WALLS TO BE REMOVED AS INDICATED BY DASHED LINES.
PATCH AND REPAIR AS NEEDED. SEE SHT. A2.1 FOR NEW LAYOUT.
OEXISTING DOOR 4 FRAME TO BE REMOVED AS INDICATED BY DASHED
LINES. SEE SHT. A2.1, FOR NEW LAYOUT.
OEXISTING WALL AND WOOD FRAME TO BE REMOVED AS INDICATED BY
DASHED LINES. PATCH AND REPAIR AS NEEDED. SEE SHT. A2.1 FOR
NEW LAYOUT.
5 REMOVE EXISTING COMPUTER, PHONE COMMUNICATION, SECURITY
O DEVICES 4 LOW VOLTAGE WIRING, ELECTRICAL LIGHT SWITCHES,
J- BOXES, AND FLOOR STUB -UPS WITH THEIR RESPECTIVE CONDUIT AND
WIRING BACK TO THEIR RESPECTIVE DISTRIBUTION PANEL OR
ELECTRICAL PANEL AND DENOTE AVAILABLE BREAKERS ON EXISTING
PANELS IN PARTITIONS AND CEILINGS WHICH ARE BEING REMOVED.
RELOCATE IF INDICATED. SEE SHT. E2.1 FOR SCOPE OF WORK
O6 REMOVE AND DISPOSE EXISTING MILLWORK AS INDICATED BY
DASHED LINES. SEE SHTS. A2.1 4 A5.1 FOR NEW PLANS, ELEVATIONS
AND DETAILS.
EXISTING DRINKING FOUNTAIN 4 ACCESSORIES TO BE REMOVED AND
CAPPED. SEE PLUMBING SHTS. FOR NEW SCOPE OF WORK
OEXISTING JANITOR'S CLOSET TO BE REMOVED AND CAPPED. SEE
PLUMBING SHTS. FOR NEW SCOPE OF WORK.
OEXISTING LAVATORY TO BE REMOVED AND REPLACED. SEE PLUMBING
SHTS. FOR NEW SCOPE OF WORK.
10 PORTIONS OF EXT'G DRYWALL CEILING TO BE REMOVED TO
ACCOMMODATE NEW WORK SEE SHTS. A6.1 4 A2.1 FOR NEW SCOPE OF
WORK
it PATCH 4 REPAIR EXT'G GYP. 15D. CEILING AS REQUIRED.
EXISTING LIGHTS TO BE REMOVED AND RELOCATED. RE -LAMP AND
12 CLEAN FOR AN 'AS NEW CONDITION' LOOK - FOR SCOPE OF WORK
REFER TO SHT. ELI FOR NEW LOCATION.
13 EXISTING LIGHTS TO REMAIN. RELAMP AND CLEAN FOR AN 'AS
NEW' CONDITION LOOK-
REMOVE EXT'G 2' -0' GRAB BAR AND REPLACE WITH 3' -0' GRAB BAR
SEE SHT. A5.1 FOR HTS.
15 REMOVE AND RELOCATE BATTERY PACK EMERGENCY LIGHTS. SEE
SHT. ELI FOR NEW LOCATION.
SLA5 NOTE:
CONTRACTOR SHALL SAW CUT EXISTING CONCRETE SLAB AS
REQUIRED TO ACCOMMODATE NEW ELECTRICAL MECHANICAL 4
PLUMBING WORK TO BE DONE AND REMOVE DEBRIS FROM SITE.
ONCE LATTER WORK HAS BEEN COMPLETED, CONTRACTOR
SHALL INFILL NEW TRENCHES AND EXISTING TRENCHES WITHIN
SPACE WITH A NEW 4' CONCRETE SLAB (4, 000 PSI) W /6X6,
W1.4xW1.4 W.W.F. OVER VAPOR BARRIER ON WELL COMPACTED FILL
W /IN AFFECTED AREAS, ALIGN FLUSH WITH EXISTING.
1
I
1
I
_T
NOTE
I.- CONTRACTOR SHALL LOCATE AFFECTED J- BOXES, FOR
POWER AND TELEPHONE. MODIFY AS REQUIRED FOR NEW
WORK WITHOUT DISTURBINCs ADJACENT TENANTS. IF
CONTRACTOR MUST DISCONNECT OTHER TENANT'S POWER
SUPPLY, TELEPHONE, OR OTHER ELECTRIC CIRCUITRY TO
ACCOMPLISH WOW-, HE IS TO COORDINATE WITH LANDLORD'S
REPRESENTATIVE AS TO WHEN WORK CAN BE PERFORMED.
CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR ANY
DAMAGES, TENANT COMPLAINTS THAT OCCUR AS A RESULT OF
FAILURE TO COMPLY WITH THIS REQUIREMENT.
2.- ALL DEMOLITION TO COMPLY WITH F.B.G. 2001 EDITION - SECTION
3401.1 AND F.B.G. EXISTING BUILDING 200-1 EDITION - SECTION 1403.
NOTE:
CONTRACTOR SHALL TEMPORARILY SECURE ALL EXT'G LIGHT
FIXTURES, EXIT SIGNS, FIRE ALARM, ETC. TO REMAIN DURING THE
REMOVAL OF EXISTING CEILING AND REINSTALLATION.
REINSTALL AND REFINISH ALL ITEMS. SEE ADDITIONAL SCOPE
OF WORK WITHIN ELECTRICAL DRAWINGS.
LEGEND:
`D-
I— EXISTING TO REMAIN
r - - EXISTING TO BE DEMOLISHED
NOTE:
ALL WORK SHALL BE PERFORMED TO MEET AND COMPLY WITH
FLA. BUILDING CODE -2001 EDITION CHAPTER 11 FLORIDA
ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION.
E a I-
DEMOLITION FLOOR PLAN
SCALE: 114' = 1' -0'
-O
-O
-O
-O
-O
- -O
Ili
I`ry OF SOU 13 � 1d M
P,t ILID1N G DEPT
IL i hl
S"if1UC "fURPL 9
i 2 3 4
_ ,4
C
.... .
�,..,. - -
- -� -- - - - - - - - - I�- - - - - - -f - - - - - - -
AREA OF WORK
KEG' PLAN - F1RST FLOOR
cnKLos oinz & assoc
ARCHITECTS, PA
AA 0003014
ARCHITECTURE
INTERIOR DESIGN
1526 N.W. 89th CT
MIAMI, FLORIDA 33172
TEL: 305 599 2888
FAX: 305 599 3885
0 1997 CARL05 pIAX t A650G. AIRCHITECTS, PA.
The Design and Drawings For thls Project are the
property of the Architect and are protected under
the Ccpyrlght Protection Act.
ARCHITECTURE
CARLOS DIAZ
+ 9531
1526 N.W. 89th CT.
MIAMI, FL 33112
PH: (305) 599 -2688
V.
z
mi
u
GG
UJI
O
ZW
r
M
o
J �'-�
o
o
w Wo
`r�
LL
w
ne
D N
5
De
O
O
cn
=
cbg�
D
°
LLJ
1--
V
Z
_
_
I
OWNER INFORMATION:
TERAHEN, INC.
A Florida Corporation
6333 SUNSET OR
SOUTH MIAMI, FLORIDA
33143
DEMOLITION FLOOR
PLAN, Kr=Y PLAN,
LrEC�FEND 4 NOTF-S
SCALE AS NOTED
PROJECT NO. 091016
DATE 03.18.09
REVISIONS:
SHEET
All
OF 20