Loading...
13-581-002PROJECT # 0000 -0000 SHEET #: AC002 PRINT DATE: May 15, 2013 DRAWING NAME Access Control Plan Dwg 2 of 2 PROJECT SUITE 600 6280 SUNSET DRIVE MIAMI, FLORIDA 33139 SECURITY CONSULTANT PILL TO ENTER OWER SUPPLY DROPPED OIL CEILING HT. TYPICAL NON— SECURE/ g 'PUBLIC" SIDE /SEE PLAN - - - - - -- ES SECURE SIDE /SEE PLAN CR N CLIENT GLANZ 4� TECHNOLOGIES, INC. �,,��F,G�STRgTO,S,� 687 NE 124th Street 7' NO 4980 ., , Ttff E• North Miami, Florida 33161 _ _ (Y p I%N; C .)RA.,, 49801 STATE OF STAT bF'FCORIb,� ° %S /�_� „nR0`���``QG?� 05.Y5:13 5 /�NA�L1110���.�``` date: CLIENT NFPA 101 NOTES 7.2.1.6.2 Access — Controlled - E-gi-- ess- Dccrs-. When permitted in Chapters 11 through 42, doors in the means of egress shall be permitted to be equipped with an approved entrance and egress access control system, provided that the following criteria are met: (1) A sensor shall be provided on the egress side, arranged to detect an occupant approaching doors that are arranged to unlock in The direction of egress upon detection of an approaching occupant or loss of power to the sensor. (2) Loss of power to the part of the access control system that locks The doors shall automatically unlock the doors in the direction Of egress. (3) The doors shall be arranged to unlock in the direction of egress >From a manual release device Located 40 in. to 48 in. (1015 mm To 1220mm) vertically above the floor and within 60 in. (1525 Mm) of the secured doors. (4) The manual release device specified in 7.2.1.6.2(3) shall be readily Accessible and clearly identified by a sign that reads as follows: PUSH TO EXIT (5) When operated, the manual release device shall result in direct Interruption of power to the lock — Independent of the access Control system electronics — and the doors shall remain Unlocked for not less than 30 seconds. (6) Activation of the building fire— protective signaling system, if Provided, shall automatically unlock the doors in the Direction of egress and the doors shall remain unlocked Until the fire — protective signaling system has been manually Reset. (7) The activation of manual fire alarm boxes that activate the Building fire — protective signaling system specified in 7.2.1.6.2(6) Shall not be required to unlock the doors. (8) Activation of the building automatic sprinkler or fire detection System, if provided, shall automatically unlock the doors in the Direction of egress and the doors shall remain unlocked until The fire — protective signaling system has been manually reset. SCOPE OF WORK SCOPE OF WORK INCLUDES CARD ACCESS FOR (1) SINGLE DOOR WHICH ENTERS INTO THE PHYSICAL ROOM. SEE PLAN ABOVE. -1 CD[P0L MIAMI -DADE C,0!,JN r! FIRE DE �nRTM BLDG. PC-R +• f : __. _ - — FIftESUP ?R SC to I� ,'1':: MAIN F_XT. — r� s Y