13-302-001(DE 2�1 V Q 10 11 12 KVA kl KUM Umlf - 711`mL- .� �•� Q� 01 QI --------- - 4 I I _1 II L------- - - - --� L-- ------ - - - - -- SCOPE = Po SHALL INCLUDE ALL LABOR, MATERIALS AND APPLIANCES REQUIRED FOR THE FURNISHING, INSTALLING AND TESTING, COMPLETE AND READ C :FORR OPERATION OF ALL WORK SHOWN ON THE DRAWING AS SPECIFAED7- HERE4N:- n 1. DISTRIBUTION SYSTEM 2. CONDUIT AND RACEWAY 3. CONDUCTORS " " "° 4. MISCELLANEOUS MATERIALS 5. LIGHTING FIXTURES AND RECEPTACLES m CODES THE INSTALLATION SHALL COMPLY WITH ALL LAWS APPLYING TO ELECTRICAL INSTALLATION IN EFFECT WITH THE REGULATIONS OF THE 2008 EDITION OF THE NATIONAL ELECTRIC CODE AND ALL LOCAL GOVERNING CODES AND ORDINANCES WITH THE REGULATION OF THE SERVING UTILITY COMPANY. ALL PERMITS REQUIRED SHALL BE OBTAINED AND, AFTER COMPLETION OF WORK, THE OWNER SHALL BE FURNISHED A CERTIFICATE OF FINAL INSPECTION AND APPROVAL. TESTING UPON COMPLETION OF THE INSTALLATION, OPERATE AND ADJUST ALL EQUIPMENT AND SYSTEMS TO MEET SPECIFIED PERFORMANCE REQUIREMENTS. ALL TESTING SHALL BE DONE BY QUALIFIED PERSONNEL. GUARANTEE IN ADDITION TO THE GUARANTEE OF THE EQUIPMENT BY THE MANUFACTURER EACH PIECE OF EQUIPMENT SPECIFIED HEREIN SHALL ALSO BE GUARANTEED FOR DEFECTS OF MATERIAL OR WORKMANSHIP OCCURRING DURING A PERIOD OF ONE (1) YEAR FROM FINAL ACCEPTANCE OF THE WORK BY THE OWNER. WITHOUT EXPENSE TO THE OWNER ALL WARRANTEE CERTIFICATES AND GUARANTEES FURNISHED BY THE MANUFACTURERS SHALL BE TURNED OVER TO THE OWNER. FIRESTOPPING ALL OPENINGS AROUND EXPOSED BUS, CONDUITS, WIRING OR CABLES IN WALLS, FLOORS, PARTITIONS, CEILING AND ROOFS SHALL BE FILLED WITH APPROVED NON — COMBUSTIBLE FIRE STOP MATERIALS, OR SHALL BE CLOSED OFF BY CLOSE — FITTING METAL CAPS AT THE CEILING AND FLOOR LINE, AND ON EACH SIDE OF A WALL OR PARTITION, TO FORM A FIRE OR SMOKE BARRIER. CUTTING, PATCHING AND EXCAVATION: COORDINATION OF ALL SLEEVES, CHASES, ETC,, WILL BE REQUIRED PRIOR TO THE CONSTRUCTION OF ANY PORTION OF THE WORK. ALL CUTTING AND PATCHING OF WALLS, PARTITIONS, FLOORS, AND CHASES IN CONCRETE, WOOD, STEEL OR MASONRY SHALL BE DONE AS PROVIDED ON THE DRAWINGS. ALL NECESSARY EXCAVATIONS AND BACK FILLING INCIDENTAL TO THE WORK UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWING SHALL BE PROVDED BY THIS CONTRACTOR. RACEWAYS ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. ALL CONDUIT SHALL BE RIGID STEEL, SCHEDULE 40 PVC OR ELECTRICAL METALLIC TUBING (EMT). WHERE INSTALLED ON ROOFS OR EXPOSED TO DAMAGE, ALL CONDUIT--SHALL BE RIGID STEEL OR EMT. ALUMINUM CONDUIT SHALL NOT BE ALLOWED. EMT MAY BE USED IN ALL OTHER ABOVE GROUND LOCATIONS. UNDERGROUND CONDUITS SHALL BE RIGID STEEL` OR SCHEDIl{ 40 PVC. ., ALL CONDUIT RUNS SHALL USE APPROVED COUPLING S_. � ,... AND °COIJNEOTORS. PRCVIDE INSULATED BUSHING FOR ALL CONDUIT TERMINATIONS., =ALL: CONDUIT RUNS IN A WET LOCATION SHALL HAVE WATERPR60F FETjNGS. PRCVIDE SUPPORTS FOR ALL CONDUITS IN ACCORDANCE WITH_NECx, REQUIREMENTS. ALL CONDUITS SHALL BE SIZED AS REQUIRED _.BY-NEC. CONDUCTORS FUMISH AND INSTALL ALL CONDUCTORS CALLED FOR IN" -THE- DRAWINGS. ALL CONDUCTORS SHALL HAVE TYPE THW /THWN (75 DEGREE) "INSULATION, RATED FOR 600 VOLTS. ALL CONDUCTORS SHALL BE COPPER, THE USE OF ALUMINUM.._CONDUCTORS SHALL NOT BE ALLOWED, ALL CONDUCTORS SHALL BE UL - LISTED..AND SHALL BE PROVIDED AND INSTALLED AS FOLLOWS: A. MINIMUM WIRE SIZE SHALL BE #12 AWG. B. ALL CONDUCTORS SIZE #8 AND LARGER SHALL BE `STRANDED. CONDUCTORS SIZED #10 AND SMALLER SHALL BE'—SOLID--OR STRANDED. C. CONNECTION FOR #10 AWG AND SMALLER SHALL r BE- BY TWISTING TIGHT AND INSTALLING INSULATED PRESSURE OR WIRE­NUT CONNECTIONS. D. CONNECTION FOR #8 AWG AND LARGER SHALL BE BY,_,USE_ OF STEEL CRIMP —ON SLEEVES WITH NYLON - INSULATOR, ALL CONDUCTORS SHALL BE COLOR CODED IN ACCORDANCE WITH NEC STANDARDS. THE RACEWAY SYSTEM SHALL BE COMPLETE BEFORE INSTALLING CONDUCTORS. GROUNDING ALL ELECTRICAL NEUTRALS, RACEWAYS AND NON— CURRENT CARRYING PARTS OF ELECTRICAL EQUIPMENT AND ASSOCIATED ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH NEC ARTICLE 250. THIS SHALL INCLUDE NEUTRAL CONDUCTORS, CONDUITS, SUPPORTS, CABINETS, BOXES, GROUND BUSSES, ETC, THE NEUTRAL CONDUCTOR FOR EACH SYSTEM SHALL BE GROUNDED BY ONE POINT ONLY. f � : Zi I�11 �7 � e � : Z�1 � P► I � Z � i 7 � 1 � I R � C � ] : � (� / � � :7 T i l � 1 5 � / \'�� a� NsC 1, a s 0 ST TE 0 a l% 1-l" i • • DWG, ND, SUITE 603 DATE. DEC. 4, 2012 SCALE., NOTED DRA WN B Y• N,C,L, REV, DATE I I J APPROVED BY.• SHEET NO. OF � r.d 1---1 Lo d- N k N N v 1-1 w W > , r- O W t� O Ld _I ~ Q N U ^ r? r_ cn Q LLJ � vo 0 Q O Lo W (oQ= O U r7 I— OL U Z 1-l" i • • DWG, ND, SUITE 603 DATE. DEC. 4, 2012 SCALE., NOTED DRA WN B Y• N,C,L, REV, DATE I I J APPROVED BY.• SHEET NO. OF � r.d