Loading...
13-302-003I=nn SUPPLY. RETURN aAFFUES AS REOU RO NOTES: (SEE TIP TLS DETALJ 1S0D WT a11A Mvr F 1. REMOVE ALL BURRS AND SHARP EDGES /� Ex1n4 9 812 TYP 2000 2. BAFFLE MUST BE CENTERED BETWEEN FUEL SUPPLY AND RETURN DIP TUBES IT f (TYP.) 2.00 3. TANK IS DESIGNED TO SUPPORT GENSET 2000 wT �° �/� 4. •'TANK TO BE PRESSURE TESTED TO 3 PSI-- I Sao MPY FUEL InE1 CN10E 3 25 F 5. TANK TO BE INSTALLED IN ACCORDANCE WITH AFFIXED LA9EUNG, THE FLAMMABLE AND 4000MPF E- COMBUSTIBLE LIQUID CODES, NFPA 30 AND ANY OTHER PREVAILING CODES 4000 1PT E -'w 6. TANK IS DESIGNED AS SECONDARY CONTAINMENT, SINGLE TOP STUB- P AREA 7. VENDOR TO SUPPLY THE FITTINGS WITH REMOVABLE PLUGS 2000 Mar NORMAL YTNT OPEN TMPU BOTTOM 8 MATERIAL. INNER TANK= 10 CA .135' [3,5] ASTM A36 1= rPf FUEL RUPTURE BASIN = 10 CA .135• [3,5] ASTM A36 uA SW°' TANK SUPPORT LEGS = .250* [6,01 ASTM A108 1018 UR ASTM A136 38.50 i 11 3/4 LIFT BRACKETS = .500' [12,0] ASTM A108 1018 OR ASTM A136 9. UFT BRACKETS TO BE CAPABLE OF LIFTING A TOTAL VERTICAL LOAD OF 10,0001 PLUS THE 18 50 - _ WEIGHT OF THE TANK 9.50 7 1/4 10. MTV-5011 - FINISH PAINT 800 11.50 L 2 0� WT 20.00 ISOO NRT La FUEL S•IIpU 77.00 2 MPF D(IR" 81.50 Ioo WO ` 500 NPT PIPE 1 500 X 1/2 NPI 86.00 11_- DOUBLE YAP BU:>H'IC 90.50 I F (SUPPLIED W/ TANK) 109.00 (OVERALL I 4,(r 250 113.50 TANK HEIGHT 94.00 (4X) pIP TUBE DETAIL 800 (t us, SIPPLY a RETURN) (TYP) 5.38 (wT YO V_" I 7.25 1800 .500 NPT (20 1/4) S° "_L/ ILL 0°z I i �SCUILY FILL CO.ECIOR L____________ ________ _ _____- _� DRAIN ! i 1/2 I r 15.00 46 00 (MAX) L-571 000 48 00 - -T I 20 W r z e o � t 0 MP MMNaN ,21.00 � -- 13600 DCIU'_ C sGL SPILL/FILL CONTAINMENT BOX 8' C- CHANNEL 011.5 / /FT. TYP. FUEL TANK DETAIL 6 AMP BATTERY CHARGER BATTERY LOCATION --\ ..LANCE WIDTH AA 5GL SPILL /FILL 17 1/2r 23 5/8 I I- 20 - (100 1/8) 12 -1- (BOTHOS DES) -'[` (BOTHOS OR -'r 12 FUEL RETURN 27 1/4 DUCT EXHAUST ' FLANGE HEIGHT FLOW , FUEL TANK NOTES 1. FUEL TANK SHALL BE STEEL DOUBLE WALLED CONSTRUCTION. SEE TANK DETAIL FOR MATERIAL TYPE AND SIZE. 2. INTERSTITIAL TANK LEAK DETECTOR SHALL BE MONITORED AND ALARMED BY GENERATOR CONTROLLER. ALARMS TO BE AUDIBLE. SEE GENERATOR DETAIL FOR LOCATION OF CONTROLLER. 3. FUEL TANK SHALL BE PROVIDED WITH AN OVERFILL LEVEL GAUGE WHICH IS VISIBLE TO THE PERSON MONITORING THE FILL. SEE TANK DETAIL FOR LOCATION. 4. FUEL TANK SHALL BE ATTACHED TO THE CONCRETE PAD WITH 3/4" CONCRETE INSERT ANCHORS, LOCATED IN EACH SKID MOUNTING HOLE. SEE TANK DETAIL FOR LOCATION. 5. NORMAL 2" FUEL TANK VENT SHALL BE EXTENDED TO A HEIGHT OF 12' ABOVE GRADE WITH 2" RIGID PIPE. SEE TANK DETAIL FOR LOCATION OF VENT. 2 8 7/8 13 5/8 STUB -UP AREA PMG INTAKE AREA -CONTROL PANEL AC CONNECTION BOX 61 7/8 04 LIFTING HOLE (4X) FUEL INLET GROUND LU LOCATIO BATTERY U WATER flpU wA.n 1v 1 4 SPACE SAVER MUFFLER DwG. is DS100D6SPA(4045HF)L1 -MD -201 I NOTES: '. HOUSING AND EXHAUST NOT SHOWN IN TOP VIEW 2. APPROX UNIT WEIGHT: (WET) XXXX/ LESS FUEL 3. APPROX C.O.B. LESS FUEL TANK J_(2 100 AMP I (103 1/4) 0 MAINLINE CIRCUIT BREAKERS 50 1 - I (DOOR) 6 8 3/8 36 3/8 1 I � M QI I I 1 I I 16 50 15 03/4 MTG 46 (2 1/4) J - 54 3/8 (CENTER OF BALANCE) HOLES (8X) 48 121 85 136 A 1 06 -28 -13 RENSpN I DAZE SUBMITTAL REVISIDN DE XRFnON JTG INKS ENGRE:4045HF285 ENCIASURE:102327 GENERATOR 362 W/ PMG BREA Ot MULTIPLE RADIATOR 80757(DR -2690) TALK 108 -3264 RADIATOR AMBIENT: 50C MUFFLER: 4 SP SAVER DUCT FIANCE: 84094 TRAILER: NA CONTROL PANEL: DGC -2020 ISOLATORS: PADS BASE: 95830 GENERATOR DETAIL DIMENSIONAL LAYOUT DRAWN TO SCALE MODEL DS10OD6SPA ALL D•ENSpN6 ARE N 100 DATE: 06 -28 -13 1 DRAWN BY: JTG DWG. f:DS100D6SPA(4045HF)LI -MD -201 APIAIRV!ED BY MIA i �!•� f. E C:► :z�f riL;c TC.%'- 1.�Elff SPK _ _ F[. G. FE R!, -' -!T SITE, W Ai`E 10N n' 4 EA. 5.5" GALV. HOOK LIFTERS TYP. AS SHOWN IN PAD. 111-811 1' -4" O 6' -10" TOP VIEW 8' -8" FRONT VIEW NOTES: 1. 3/4" CHAMFER ON ALL EXPOSED TOP EDGES 2. MIN 3,000 PSI CONCRETE PAD STRUCTURE TYPE 1' -0" O �f f CHAMFER ALL TOP EDGES 6" PRODUCTION WEIGHTS REINFORCEMENT YARDAGE SLAB 0.63 CYDS 2469 #6 0 12. OCEW TOTAL: CASTING: STEEL WT.: CONC WT.: DRAWN: JB DATE: CHECKED: DATE: PRODUCED: SHIPPED: STIR. NO.: PAD I S.O. N0: LN. NO.: POWER PRO -TECH SERVICES DRAWING NO.: LOC.: SCALE 1- - 2' SHEET: OF GENERATOR PAD DETAIL OF SOUTH MIA1 iF =lU!L0lP,JG DEPT. " LIC T URAL SECT10p4 1 4 0 A. OF 'r I�v1 W FI O P4 W r , w � �., o A co Y� E-+ �n . rr�D 1T �D V1 V1 W F DWG, ND, SUITE 603 DA TE: JULY 2, 2013 SCALE: NOTED DRAWN BY: N.C.L. REV. DATE APPROVED BY: SHEET N0. OF E -2 Ln _t C14 T � v N N 1--� LJ W Q� � o W n J Lu Yid' N U M--1 J IJi M � Q v W Q 00 CL -I O Lo W (D Q= O U Map.. U Z 0 L) W FI O P4 W r , w � �., o A co Y� E-+ �n . rr�D 1T �D V1 V1 W F DWG, ND, SUITE 603 DA TE: JULY 2, 2013 SCALE: NOTED DRAWN BY: N.C.L. REV. DATE APPROVED BY: SHEET N0. OF E -2