13-160-001
a a N ri I M a N 0 4 3 �i s N I N 1 a 0 0 LL s 0 a 1 0 c 0 00 N a a a I 0 M 0 I Ni M 0 N W J li a a FIRE ALARM SYSTEM NOTES 1. THE EXTENT OF THE FIRE ALARM SYSTEM WORK IS INDICATED BY THE DRAWINGS AND SCHEDULES. 2. ANY SURFACE MOUNTED FIRE ALARM DEVICES, i.e., PULL STATION, STROBES, HORN /STROBE SHALL BE MOUNTED IN "SYSTEMS" BOXES PROVIDED BY THE MANUFACTURER. DO NOT USE 1900 TYPE ELECTRICAL BOXES PAINTED RED. 3. FIRE ALARM SHALL NOT BE INSTALLED UNTIL CLEANUP OF ALL OF ALL TRADES ARE COMPLETE. FAILURE TO COMPLY WITH THIS NOTE WILL VOID ALL WARRANTIES. 4. ALL FIRE ALARM SYSTEM DEVICES ARE UL LISTED AND COMPATIBLE WITH FIRE ALARM PANEL AND POWER SUPPLY. 5. SIGNALING CIRCUITS SHALL BE POWER LIMITED PER NEC 760 -11. CABLE PENETRATION INTO OR THROUGH PLENUM AREAS USED FOR TRANSFER OF ENVIRONMENTAL AIR SHALL BE TEFLON INSULATED TYPE OR OF AN APPROVED TYPE IN ACCORDANCE WITH SECTION 800 -3(D) OF THE NATIONAL ELECTRIC CODE. 6. FIRE ALARM CONTROL PANEL MUST BE CONNECTED TO BUILDING COLD -WATER GROUND VIA 1 GREEN #10 THHN OR EQUIVALENT. 7. ALL WIRING MUST CONFORM WITH NEC ARTICLE 760 AND LOCAL CODES. ALL EQUIPMENT SHALL BE UL LISTED. ALL DEVICES SHALL BE COMPATIBLE WITH THE CONTROL PANEL. 8. ALL INSTALLATION MATERIAL SUCH AS CONDUIT FITTINGS, BOXES, HANGERS, ETC. ARE TO BE PROVIDED AND INCLUDED. 9. ALL INITIATING AND INDICATING CIRCUITS MUST BE SUPERVISED. 10. CIRCUIT POLARITY MUST BE OBSERVED. 11. WIRE RUNS ARE SHOWN DIAGRAMMATICALLY. EXACT LOCATION OF ALL EQUIPMENT TO BE DETERMINED IN THE FIELD, BUT SHALL CONFORM WITH THE BASIC LAYOUT AS SHOWN ON DRAWINGS TO PREVENT CIRCUIT OVERLOAD. 12. DETECTORS SHALL NOT BE LOCATED IN DIRECT AIR STREAM • FROM SUPPLY AIR OUTLETS. MAINTAIN A MINIMUM CLEAR DISTANCE OF 36 ". OFFSET /ADJUST LOCATIONS AS REQUIRED. 13. MINIMUM CONDUIT SIZE WILL BE 1/2" UNLESS OTHERWISE NOTED. CONDUIT SHALL BE NO MORE THAN 40% FILLED. 14. DO NOT MARK ID NUMBERS ON DEVICES. LABEL BASE ONLY. 15. POWER UP & POWER DOWN ON PANEL MUST BE DONE IN SEQUENCE: POWER DOWN A - DISCONNECT BATTERY. B - TURN OFF AC POWER PRIMARY & SECONDARY. POWER UP A - TURN ON AC POWER PRIMARY & SECONDARY. B - RECONNECT BATTERIES. 16. THE FIRE ALARM CONTROL PANEL SHALL NOT BE USED TO POWER ANY UNAUTHORIZED EXTERNAL DEVICE. 17. STROBES ARE TO BE WALL MOUNTED AND SYNCRONIZED PER ADA REQUIREMENTS. LOCATION OF THESE DEVICES TO BE DETERMINED IN FIELD. MOUNT STROBES 80" AFF TO TOP OF LENS, OR 6" BELOW CEILING TO TOP OF LENS, WHICHEVER IS LOWER. 18. ALL HORNS TO BE TAPPED AT STD SETTING EACH PROVIDING 93 DB AT 10 FT (TYPICAL AN ECHOIC DBA). 19. IDENTIFYING NUMBER ADJACENT TO DEVICE SYMBOL DENOTE DEVICE ZONE ADDRESS. DETECTOR D -02 / M -02 WILL IDENTIFY THE SECOND DEVICE / MODULE CONNECTED TO LOOP 1 ON SLC BOARD. 20. HVAC SYSTEM SHALL COMPLY WITH NFPA 90A IN SYSTEM OF OVER 2,000 CFM CAPACITY, DUCT DETECTOR INSTALLATION SHALL BE AT A SUITABLE LOCATION. 21. BUILDING IS FULLY FIRE SPRINKLED AND SUPERVISED. 22. THIS FIRE ALARM SYSTEM IS CLASSIFIED AS AN EXISTING REMOTE SUPERVISING STATION (NFPA 72.8.4) 23. FIRE ALARM SYSTEM SHALL BE MONITOR BY A DIALER WITH (2) SUPERVISED TELEPHONE LINES. 24. FIRE ALARM IS REQUIRED UNDER SECTION NFPA 101.39.3.4 25. AS -BUILT OF FIRE ALARM IS REQUIRED AND PERFORMED UNDER SECTION NFPA 72.10.6.1.1 & 72.10.6.1.3 25. THE DESIGN COMPLIES WITH FLORIDA BUILDING CODES 2010 EDITION CHAPTER 9 & UNDER CODE OF ORDINANCES OF MIAMI -DADE COUNTY PART III - CODE OF ORDINANCES, CHAPTER 14 - FIRE PREVENTION. 26. INSTALLATION SHALL COMPLY WITH NFPA 1, 2009 EDITION, "FIRE CODE" APPLICABLE CHAPTERS. 27. INSTALLATION SHALL COMPLY WITH NFPA 101, 2009 EDITION, "LIFE SAFETY CODE" APPLICABLE CHAPTERS. 28. INSTALLATION SHALL COMPLY WITH NFPA 72, 2007 EDITION, "NATIONAL FIRE ALARM CODE" APPLICABLE CHAPTERS. 29. INSTALLATION SHALL COMPLY WITH NFPA 70, 2008 EDITION, "NATIONAL ELECTRICAL CODE " 30. THE EXISTING BATTERY CALCULATIONS, THE EXISTING WIRE SIZE HAS BEEN ASSUMED FOR A COLLECTION OF DATA & COUNTING OF EXISTING EQUIPMENT/ DEVICES. AS -BUILT AND /OR REPORTS PERFORMED BY AS FOLLOWS: * MEP CONSULTING ENGINEERS, INC. 31. EXISTING EQUIPMENT/ DEVICES ARE SHOWN FOR INFORMATIONAL PURPOSES ONLY. THE DESIGN ONLY COVER ALL THE EXISTING EQUIPMENT / DEVICES THAT ARE IN CONTRACT. 32. EXISTING COMMERCIAL BUILDING IS A SIX STORY BUILDING HAS A 9 FEET DROP CEILING HEIGHT 1 (TYPICAL FOR ALL SPACES UNLESS OTHERWISE NOTED). 33. THE EXISTING FACP SK -5208 AND SK -5700, POWER BOOSTERS SUPPLY SK -5495 ARE LOCATED IN ELECTRICAL ROOM AT FIRST FLOOR. THIS ROOM IS MECHANICALLY VENTILATED. U J Ff SjE� � SUITE # 603 - ON SIXTH FLOOR 6280 SUNSET DR., MIAMI, FL. 33143 .,,�oItlII����IIIIIII�,, LOCATION MAP SYMBOL LEGEND SYMBOL DESCRIPTION MODEL MOUNTING FA -2 FIRE ALARM SYSTEM RISER DIAGRAM SILENT KNIGHT BATTERY CALCULATION FACP FIRE ALARM CONTROL PANEL SK -5208 SK -5700 MOUNT 72" A.F.F. TO TOP, z SK POWER BOOSTER SILENT KNIGHT MOUNT 72" A.F.F. TO TOP, -5495 W SK5495 X ° W W ANN LCD REMOTE ANNUNCIATOR SILENT KNIGHT MOUNT ON A SBB -3 G) 0 cQ SK5235 3 GANG ELETRICAL BOX U) SD PHOTOELECTRIC SMOKE SILENT KNIGHT CEILING MOUNT ON A 4" 1900 BOX. DETECTOR W/ BASE SK505 -APS Q INTELLIGENT HEAT DETECTOR SILENT KNIGHT CEILING MOUNT ON A 4" 1900 BOX. lJ DETECTOR W/ BASE SK505 -AHS SILENT KNIGHT MOUNT 48" A.F.F. TO CNTR © MANUAL PULL STATION SK500 -PS ON A 3 1/2 " DEEP, 1 GANG BOX, M❑ MINI - MONITOR MODULE SILENT KNIGHT MOUNTS DIRECTLY TO A 4" BOX. Li SK505 -MIM 0 MULTI - CANDELA HORN STROBE COOPER WHEELOCK MOUNT 80" A.F.F. TO BOTTOM, ``�j Li EXCEDER HSR ON A 4" 1900 BOX Li MULTI - CANDELA STROBE DEVICE COOPER WHEELOCK MOUNT 80" A.F.F. TO BOTTOM, EXCEDER STIR ON A 4" 1900 BOX SD DUCT SMOKE DETECTOR W/ RELAY MODULE SILENT KNIGHT SK505 -DUCTR MOUNTED ON 4" SQUARE BOX. R rs ❑ WATERFLOW SWITCH PROVIDED BY OTHERS MOUNTED ON SPRINKLER RISER PIPE Ts TAMPER SWITCH PROVIDED BY OTHERS MOUNTED ON SPRINKLER RISER PIPE JVV- END OF LINE RESISTOR () K INSTALL VALUE AS SHOWN ON RISER NOTE: WIRE TYPES LISTED IN THE WIRE LEGEND ARE THE MANUFACTURER'S MINIMUM WIRING REQUIREMENTS. CONTRACTOR SHALL CHOOSE WIRE TYPES AND RATING TO MEET THESE REQUIREMENTS AND ALL OF THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE AND NFPA FOR THE APPLICATIONS AND LOCATIONS OF USE. 1 mug NFPA 72; 70; r v • i INSPECTION REPORT PLANS i FLOOR ONLY iCOngV1} ng engineerS FIRE ALARM SYSTEM W 1 y fli :I in,y �crrniYt.in,y JANUARY 2013 SCOPE OF WORK TO PROVIDE THE EXISTING BUILDING A FIRE ALARM SYSTEM AS PER NFPA 72 & 101 STANDARDS TO DETECT EARLY FIRE, ALERT BUILDING OCCUPANTS AND FIRE DEPARTMENT IN THE EVENT OF A FIRE. OUR SCOPE ONLY COVERS THE NEW CONSTRUCTION ON THE LOCATED AT SUITE 603 AS FOLLOWS: 1. TO BE REMAIN (EXISTING FIRE ALARM SYSTEM NOT IN CONTRACT), 2. TO INSTALL (NEW):17 SMOKE DETECTORS, 4 LIGHT & 12 HORN (STROBE) DEVICES. ALSO ALL STROBES SHALL BE SYNCHRONIZED TO THE EXISTING FIRE ALARM SYSTEM AND ALL WIRING MUST BE CUT AT EACH TERMINATION DO NOT LOOP WIRE AROUND THE SCREW. 3. EXISTING SIGNALING LINE CIRCUIT (SLC) WIRING IS STYLE 4 (TO BE REMAIN). 4. EXISTING NOTIFICATION APPLIANCE CIRCUIT WIRING SHALL BE STYLE 4 CLASS "B " (TO BE REMAIN). 1 SEQUENCE OF OPERATION: (EXISTING) UPON ACTIVATION OF ANY MANUAL STATION THE FOLLOWING SHALL OCCUR: 1. ALL AUDIBLE (HORN) AND VISIBLE (STROBE) NOTIFICATION APPLIANCES SHALL WORK UNTIL DEACTIVATION IS ACTUATED. BOTH SHALL BE SIMULTANEOUSLY DEACTIVATED. 2. AN ALARM SIGNAL SHALL BE SENT TO THE FACP. 3. A SIGNAL SHALL BE SENT TO THE SUPERVISING STATION VIA DACT. UPON ACTIVATION OF ANY AUTOMATIC DEVICE THE FOLLOWING SHALL OCCUR: 1. ALL AUDIBLE (HORN) AND VISIBLE (STROBE) NOTIFICATION APPLIANCES SHALL WORK UNTIL DEACTIVATION IS ACTUATED. BOTH SHALL BE SIMULTANEOUSLY DEACTIVATED. 2. AN ALARM SIGNAL SHALL BE SENT TO THE FACP. 3. A SIGNAL SHALL BE SENT TO THE �� SUPERVISING STATION VIA DACT. UPON ACTIVATION OF THE ELEVATOR LOBBY SMOKE DETECTORS (WITH THE EXCEPTION OF THE ELEVATOR LOBBY DETECTOR AT THE PRIMARY LEVEL OF EGRESS), THE FOLLOWING SHALL OCCUR: 1. ALL AUDIBLE (HORN) AND VISIBLE (STROBE) NOTIFICATION APPLIANCES SHALL WORK UNTIL DEACTIVATION IS ACTUATED. BOTH SHALL BE SIMULTANEOUSLY DEACTIVATED. 2. AN ALARM SIGNAL SHALL BE SENT TOT 3. A SIGNAL SHALL BE SENT TO THE ;R6f1 UPERVISING STATION VIA DACT. 4. ELEVATORS SHALL RECALL TO THE PRIMARY LEVEL OF EGRESS. 5. FIREHAT IN ELEVATOR CAB SHALL ILLUMINATE. UPON ACTIVATION OF THE ELEVATOR LOBBY SMOKE DETECTOR AT THE PRIMARY LEVEL OF EGRESS, THE FOLLOWING SHALL OCCUR: 1. ALL AUDIBLE (HORN) AND VISIBLE (STROBE) NOTIFICATION APPLIANCES SHALL WORK UNTIL DEACTIVATION IS ACTUATED. BOTH SHALL BE SIMULTANEOUSLY DEACTIVATED. 2. AN ALARM SIGNAL SHALL BE SENT TO &A P. 3. A SIGNAL SHALL BE SENT TO THE Pfd SUPERVISING STATION VIA DACT. 4. ELEVATORS SHALL RECALL TO THE ALTERNATE LEVEL OF EGRESS. 5. FIREHAT IN ELEVATOR CAB SHALL ILLUMINATE. UPON ACTIVATION OF THE ELEVATOR MACHINE ROOM SMOKE DETECTOR, THE FOLLOWING SHALL OCCUR: 1. ALL AUDIBLE (HORN) AND VISIBLE (STROBE) NOTIFICATION APPLIANCES SHALL WORK UNTIL DEACTIVATION IS ACTUATED. BOTH SHALL BE SIMULTANEOUSLY DEACTIVATED. 2. AN ALARM SIGNAL SHALL BE SENT CP. 3. A SIGNAL SHALL BE SENT TO THE SUPERVISING STATION VIA DACT. 4. ELEVATORS SHALL RECALL TO THE ALTERNATE LEVEL OF EGRESS. 5. FIREHAT IN ELEVATOR CAB SHALL BLINK. UPON ACTIVATION OF AN ELEVATOR MACHINE ROOM HEAT DETECTOR, THE FOLLOWING SHALL OCCUR: 1. ALL AUDIBLE (HORN) AND VISIBLE (STROBE) NOTIFICATION APPLIANCES SHALL WORK UNTIL DEACTIVATION IS ACTUATED. BOTH SHALL BE SIMULTANEOUSLY DEACTIVATED. 2. AN ALARM SIGNAL SHALL BE SENT T P. 3. A SIGNAL SHALL BE SENT TO THE Y SUPERVISING STATION VIA DACT. 4. THE ELEVATOR POWER CIRCUIT BREAKER SHALL TRIP TO THE OFF POSITION. 5. THE ELEVATOR SHALL REMAIN WITHOUT POWER UNTIL ALARM IS CLEAR AND FIRE ALARM SYSTEM IS BACK TO NORMAL. UPON ACTIVATION OF A WATERFLOW SWITCH, THE FOLLOWING SHALL OCCUR: 1. ALL AUDIBLE (HORN) AND VISIBLE (STROBE) NOTIFICATION APPLIANCES SHALL WORK UNTIL DEACTIVATION IS ACTUATED. BOTH SHALL BE SIMULTANEOUSLY DEACTIVATED. 2. AN ALARM SIGNAL SHALL BE SENT TO THE FACP. 3. A SIGNAL SHALL BE SENT TO THE PROPRIETARY SUPERVISING STATION VIA DACT. 4. FLOW BELL SHALL SOUND UPON ACTIVATION OF FLOW SWITCH ONLY. 5. FLOW BELL SHALL SOUND AS LONG AS WATER IS FLOWING. 6. FLOW BELL SHALL NOT BE CAPABLE OF BEING SILENCED FROM FACP. UPON ACTIVATION OF A TAMPER SWITCH, THE FOLLOWING SHALL OCCUR: 1. A SUPERVISORY SIGNAL SHALL BE SENT TO THE FACP. 2. A SUPERVISORY SIGNAL SHALL BE SENT TO THE SUPERVISING STATION VIA DACT. UPON ACTIVATION OF A DUCT SMOKE DETECTOR, THE FOLLOWING SHALL OCCUR: 1. A SUPERVISORY SIGNAL SHALL BE SENT TO THE FACP. 2. A SUPERVISORY SIGNAL SHALL BE SENT TO THE PROPRIETARY SUPERVISING STATION VIA DACT. 3. THE AIR HANDLER UNIT ASSOCIATED WITH THAT DUCT DETECTOR SHALL SHUT DOWN. UPON ANY TROUBLE CONDITION IN THE FIRE ALARM SYSTEM: 1. THE TROUBLE L.E.D. SHALL ILLUMINATE TROUBLE L.E.D. AND SOUND THE BUZZER AT CONTROL PANEL. 2. IT SHALL DISPLAY DEVICE AND LOCATION. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP. 4. A SIGNAL SHALL BE SENT TO THE FARY SUPERVISING STATION VIA DACT. j1 Q FIRE ALARM WIRE LEGEND A- 18/2 AWG FIRE POWER LIMITED (FPL) OR THHN WIRE FOR INITIATING DEVICES. B- 14/2 AWG OR THHN WIRE FOR HORN /STROBE DEVICES. C- 18/2 AWG FOR DATA COMMUNICATION. D- 18/2 AWG FIRE POWER LIMITED (FPL) 24 VOLT POWER. E- 16/2 AWG SHIELDED FPLR OR THHN WIRE FOR SPEAKERS. F- 12 AWG THHN WIRE FOR FACP & POWER SUPPLY POWER. G- 12 AWG THHN WIRE FOR FACP & POWER SUPPLY GROUND. FIRE ALARM SHEET INDEX FA COVER AND SYSTEM NOTES FA -1 SUITE # 603 FLOOR PLAN AND ELEVATOR DIAGRAM FA -2 FIRE ALARM SYSTEM RISER DIAGRAM FA -3 BATTERY CALCULATION FA-4 PENETRATION DETAILS, DEVICE MOUNTING DETAILS & WIRE GAGE RESISTANCE TABLE 9330 NW 13 ST. DORAL FL 33172 PHONE 305- 594 -2382 FAX 305 - 594 -2366 DRAWN BY�►IIUI►►n,. GEL. �'''�• ty ..... i /Q0 iii - F .z- • ly . 7 0b srAT o rte. nor / y.. d d1U111111\ PERrYlIT SET ®2m MEP ENGINEERING DESIGNS Inc. HEREBY RESERVE THEIR COPYRIGHTS TO THE IDEAS AND DRAWINGS SHOWN, THESE DRAWINGS ARE TO BE USED FOR THE PROJECT STATED ONLY AND SHALL NOT BE USED OR REPRODUCED FOR ANY OTHER PURPOSE WHATSOEVER WITHOUT THE EXPRESSED WRITTEN CONSENT. CONTRACTORS SHALL VERIFY ALL DIMENSIONS AND SHALL NOT RELY ON SCALED DIMENSIONS. NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO COMMENCING WORK. REVISION DATE(S) Q Miami -Dade 01/30/2013 A 0 PROD. NO: DATE: SHEET NO.: FA 1 Of 5 Sheets U) cr uj 0 O 0 z J _Wco 2 2 w W X ° W W LWL F _ w u) `1�^ v! G) 0 cQ O U) v! C� w Q Q t, LL H W w N u W Li 0 Li U Li V) REVISION DATE(S) Q Miami -Dade 01/30/2013 A 0 PROD. NO: DATE: SHEET NO.: FA 1 Of 5 Sheets I..f.. cr 0 O �- J _Wco w LlJ X ° W W M F _ w z G) 0 cQ O C� w 00 Q t, H N u REVISION DATE(S) Q Miami -Dade 01/30/2013 A 0 PROD. NO: DATE: SHEET NO.: FA 1 Of 5 Sheets