13-159-006
00 I M 4 N 9 I O 3 v 0 0 c N a e a N is s a i N3 M O N J 4. a CL t F Ffs r son MT SECOND FLOOR 6280 SUNSET DR., MIAMI, FL. 33143 FIRE ALARM SYSTEM NOTES 1. THE EXTENT OF THE FIRE ALARM SYSTEM WORK IS INDICATED BY THE DRAWINGS AND SCHEDULES. LOCATION MAP 2. ANY SURFACE MOUNTED FIRE ALARM DEVICES, i.e., PULL STATION, STROBES, HORN /STROBE SHALL BE MOUNTED IN "SYSTEMS" BOXES PROVIDED BY THE MANUFACTURER. DO NOT USE 1900 TYPE ELECTRICAL BOXES PAINTED RED. �V 3. FIRE ALARM SHALL NOT BE INSTALLED UNTIL CLEANUP OF ALL OF ALL TRADES ARE COMPLETE. FAILURE TO COMPLY WITH THIS NOTE WILL VOID ALL WARRANTIES. 4. ALL FIRE ALARM SYSTEM DEVICES ARE UL LISTED AND COMPATIBLE WITH FIRE ALARM PANEL AND POWER SUPPLY. 5. SIGNALING CIRCUITS SHALL BE POWER LIMITED PER NEC 760 -11. CABLE PENETRATION INTO OR THROUGH PLENUM AREAS USED FOR TRANSFER OF ENVIRONMENTAL AIR SHALL BE TEFLON INSULATED TYPE OR OF AN APPROVED TYPE IN ACCORDANCE WITH SECTION 800 -3(D) OF THE NATIONAL ELECTRIC CODE. 6. FIRE ALARM CONTROL PANEL MUST BE CONNECTED TO BUILDING COLD -WATER GROUND VIA 1 GREEN #10 THHN OR EQUIVALENT. 7. ALL WIRING MUST CONFORM WITH NEC ARTICLE 760 AND LOCAL CODES. ALL EQUIPMENT SHALL BE UL LISTED. ALL DEVICES SHALL BE COMPATIBLE WITH THE CONTROL PANEL. $. ALL INSTALLATION MATERIAL SUCH AS CONDUIT FITTINGS, BOXES, HANGERS, ETC. ARE TO BE PROVIDED AND INCLUDED. 9. ALL INITIATING AND INDICATING CIRCUITS MUST BE SUPERVISED. 10. CIRCUIT POLARITY MUST BE OBSERVED. 11. WIRE RUNS ARE SHOWN DIAGRAMMATICALLY. EXACT LOCATION OF ALL EQUIPMENT TO BE DETERMINED IN THE FIELD, BUT SHALL CONFORM WITH THE BASIC LAYOUT AS SHOWN ON DRAWINGS TO PREVENT CIRCUIT OVERLOAD. 12. DETECTORS SHALL NOT BE LOCATED IN DIRECT AIR STREAM FROM SUPPLY AIR OUTLETS. MAINTAIN A MINIMUM CLEAR DISTANCE OF 36" OFFSET /ADJUST LOCATIONS AS REQUIRED. 13. MINIMUM CONDUIT SIZE WILL BE 1/2" UNLESS OTHERWISE NOTED. CONDUIT SHALL BE NO MORE THAN 40% FILLED. 14. DO NOT MARK ID NUMBERS ON DEVICES. LABEL BASE ONLY. 15. POWER UP & POWER DOWN ON PANEL MUST BE DONE IN SEQUENCE: POWER DOWN A - DISCONNECT BATTERY. B - TURN OFF AC POWER PRIMARY & SECONDARY. POWER UP A - TURN ON AC POWER PRIMARY & SECONDARY. B - RECONNECT BATTERIES. 16. THE FIRE ALARM CONTROL PANEL SHALL NOT BE USED TO POWER ANY UNAUTHORIZED EXTERNAL DEVICE. 17. STROBES ARE TO BE WALL MOUNTED AND SYNCRONIZED PER ADA REQUIREMENTS. LOCATION OF THESE DEVICES TO BE DETERMINED IN FIELD. MOUNT STROBES 80" AFF TO TOP OF LENS, OR 6" BELOW CEILING TO TOP OF LENS, WHICHEVER IS LOWER. 1$. ALL HORNS TO BE TAPPED AT STD SETTING EACH PROVIDING.. ` 93 DB AT 10 FT (TYPICAL ANECHOIC DBA).°'' m a 19. IDENTIFYING NUMBER ADJACENT TO DEVICE SYMBOL DENOTE DEVICE ZONE ADDRESS. DETECTOR D -02 / M -02 WILL IDENTIFY THE SECOND DEVICE / MODULE CONNECTED TO LOOP 1 ON SLC BOARD. 20. HVAC SYSTEM SHALL COMPLY WITH NFPA 90A IN SYSTEM OF OVER 2,000 CFM CAPACITY, DUCT DETECTOR INSTALLATION SHALL BE AT SUITABLE LOCATION. 21. BUILDING IS FULLY FIRE SPRINKLED AND SUPERVISED. 22. THIS FIRE ALARM SYSTEM IS CLASSIFIED AS AN EXISTING CENTRAL STATION SERVICE III 72.8 23. FIRE ALARM SYSTEM SHALL BE MONITOR BY A DIALER WITH (2) SUPERVISED TELEPHONE LINES. SYMBOL LEGEND SYMBOL DESCRIPTION MODEL MOUNTING FA -2 ,~ 25. SILENT KNIGHT BATTERY CALCULATION FACP FIRE ALARM CONTROL PANEL SK -5208 SK -5700 MOUNT 72" A.F.F. TO TOP, PART III - CODE OF ORDINANCES, CHAPTER 14 - FIRE PREVENTION.' SK -5495 POWER BOOSTER SILENT KNIGHT MOUNT 72" A.F.F. TO TOP, � 26. INSTALLATION SHALL COMPLY WITH NFPA 1, 2006 EDITION, APPLICABLE CHAPTERS. '!' SK5495 27. INSTALLATION SHALL COMPLY WITH NFPA 72, 2002 EDITION, APPLICABLE CHAPTERS. ANN LCD REMOTE ANNUNCIATOR SILENT KNIGHT MOUNT ON A SBB -3 2$. INSTALLATION SHALL COMPLY WITH NFPA 101, 2006 EDITION, APPLICABLE CHAPTERS, �,. " SK5235 3 GANG ELETRICAL BOX PHOTOELECTRIC SMOKE SILENT KNIGHT INSTALLATION SHALL COMPLY WITH NFPA 70 (NEC 2005 EDITION). " "' °., .e SD DETECTOR W/ BASE SK505 -APS CEILING MOUNT ON A 4" 1900 BOX. SHALL OCCUR: INTELLIGENT HEAT DETECTOR SILENT KNIGHT 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. Q DETECTOR W/ BASE SK505 -AHS CEILING MOUNT ON A 4" 1900 BOX. 31. SILENT KNIGHT MOUNT 48" A.F.F. TO CNTR © MANUAL PULL STATION SK500 -PS ON A 3 1/2 " DEEP, 1 GANG BOX. M MINI - MONITOR MODULE SILENT KNIGHT MOUNTS DIRECTLY TO A 4" BOX. 33. SK505 -MIM CC 0 G n MULTI - CANDELA HORN STROBE COOPER WHEELOCK MOUNT 80" A.F.F. TO BOTTOM, AT FIRST FLOOR. THIS ROOM IS MECHANICALLY VENTILATED. EXCEDER HSR ON A 4" 1900 BOX ..I MULTI - CANDELA STROBE DEVICE COOPER WHEELOCK MOUNT 80" A.F.F. TO BOTTOM, 4. A SIGNAL SHALL BE SENT TO THE OWNERS CENTRAL STATION VIA DACT, EXCEDER STR ON A 4" 1900 BOX SD DUCT SMOKE DETECTOR W/ RELAY MODULE SILENT KNIGHT SK505 -DUCTR MOUNTED ON 4" SQUARE BOX. R SYSTEM IS BACK TO NORMAL. _ w V LI Fs WATERFLOW SWITCH PROVIDED BY OTHERS MOUNTED ON SPRINKLER RISER PIPE rs TAMPER SWITCH PROVIDED MOUNTED ON SPRINKLER RISER PIPE r, 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS RESET. BY OTHERS -M- END OF LINE RESISTOR () K INSTALL VALUE AS SHOWN ON RISER 24. FIRE ALARM IS REQUIRED UNDER SECTION NFPA 101.39.3.4 Y - - -w " ' -- -• -LL °� r. 25. M _ AS BUILT OF FIRE ALARM IS REQUIRED AND PERFORMED UNDER SECTION NFPA 72.10.6.1.1 & 72.10.6.1.3 FA -2 ,~ 25. THE DESIGN COMPLIES WITH FLORIDA BUILDING CODES 2007 EDITION CHAPTER 9 BATTERY CALCULATION UPON ACTIVATION OF THE ELEVATOR LOBBY SMOKE DETECTOR AT THE PRIMARY LEVEL & UNDER CODE OF ORDINANCES OF MIAMI -DADE COUNTY OF EGRESS, THE FOLLOWING SHALL OCCUR: PART III - CODE OF ORDINANCES, CHAPTER 14 - FIRE PREVENTION.' 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. , NOTE: � 26. INSTALLATION SHALL COMPLY WITH NFPA 1, 2006 EDITION, APPLICABLE CHAPTERS. '!' w.m ` "� RE TY PES LISTED IN THE WIRE LEGEND ARE THE 27. INSTALLATION SHALL COMPLY WITH NFPA 72, 2002 EDITION, APPLICABLE CHAPTERS. MANUFACTURER'S MINIMUM WIRING REQUIREMENTS. CONTRACTOR 4. A SIGNAL SHALL BE SENT TO THE OWNERS UL LISTED CENTRAL STATION VIA DACT. 'n, SHALL CHOOSE WIRE TYPES AND RATING TO MEET THESE 2$. INSTALLATION SHALL COMPLY WITH NFPA 101, 2006 EDITION, APPLICABLE CHAPTERS, �,. " �' Pte. REQUIREMENTS AND ALL OF THE REQUIREMENTS OF THE 6. FIREHAT IN ELEVATOR CAB SHALL ILLUMINATE. '' NATIONAL ELECTRICAL CODE AND NFPA FOR THE APPLICATIONS 29. INSTALLATION SHALL COMPLY WITH NFPA 70 (NEC 2005 EDITION). " "' °., .e AND LOCATIONS OF USE. 30. THE EXISTING BATTERY CALCULATIONS, THE EXISTING WIRE SIZE HAS BEEN SHALL OCCUR: ASSUMED FOR A COLLECTION OF DATA & COUNTING OF EXISTING 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. EQUIPMENT/ DEVICES. AS -BUILT AND /OR REPORTS PERFORMED BY AS FOLLOWS: W W 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS RESET: * MEP CONSULTING ENGINEERS, INC. 31. EXISTING EQUIPMENT/ DEVICES ARE SHOWN FOR INFORMATIONAL PURPOSES ONLY. co W 4. A SIGNAL'SHALL BE SENT TO THE 0)NNER L LISTED CENTRAL STATION VIA DACT. THE DESIGN ONLY COVER ALL THE EXISTING EQUIPMENT / DEVICES THAT ARE IN CONTRACT. 32. EXISTING COMMERCIAL BUILDING IS A SIX STORY BUILDING HAS A 9 FEET DROP CEILING HEIGHT U) 6. FIREHAT IN ELEVATOR CABS; TALL BLINK. , (TYPICAL FOR ALL SPACES UNLESS OTHERWISE NOTED). 33. ALL EXISTING AND /OR NEW DEVICES SHALL BE COMPATIBLE & SHALL BE UL LISTED FOR FIRE SERVICE USE. CC 0 G 34. THE EXISTING FACP SK -5208 AND SK -5700, POWER BOOSTERS SUPPLY SK -5495 ARE LOCATED IN ELECTRICAL ROOM Z 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. AT FIRST FLOOR. THIS ROOM IS MECHANICALLY VENTILATED. INSPECTION REPORT PLANS, q 11111111 FIRE ALARM SYST n•< . "i•s - Nh�nniia� - �errnitt "in.d JANUARY 2013 ., 9330 NW 13 ST. DORAL FL 33172 PHONE 305 - 594 -2382 FAX 305 - 594 -2366 SCOPE OF WORK:,...;w: ,�,. ,�.. �..� . .£ ... .� ��. ° -� DRAWN BY: TO PROVIDE THE EXISTING BUILDING AFIRE ALARM SYSTEM AS PER NFPA 72 & 101 STANDARDS TO 1101111111 / / /�� DETECT EARLY FIRE, ALERT BUILDING OCCUPANTS AND FIRE DEPARTMENT I EVENT OF A FIRE. ~~ OUR SCOPE ONLY COVERS THE NEW CONSTRUCTION ON THE LOCATED A NIT 253 AS FOLLOWS: ��� ('�` . • •' O /// TO BE REMAIN (EXISTING FIRE ALARM SYSTEM NOT IN CONTRACT). 2. TO INSTALL (NEW) :12 SMOKE DETECTORS, 1 LIGHT & 5 HORN (STROBE) DEVICES. __ 7k •� ALSO ALL STROBES SHALL BE SYNCHRONIZED TO THE EXISTING FIRE ALARM SYSTEM AND ALL _ 606 WIRING MUST BE CUT AT EACH TERMINATION DO NOT LOOP WIRE AROUND THE SCREW. • * _ T A q 3. EXISTING SIGNALING LINE CIRCUIT (SLC) WIRING IS STYLE 4 (TO BE REMAIN). . 3iA 0 ' 4. EXISTING NOTIFICATION APPLIANCE CIRCUIT WIRING SHALL BE STYLE 4 CLASS "B" (TO BE REMAIN). '. --4 "'CCCrrr .,O I P. SEQUENCE OF OPERATION: (EXISTING] All 7 d UPON ACTIVATION OF ANY MANUAL STATION THE FOLLOWING SHALL OCCUR: t 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS- SILENCED.' ~ 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS RESET. 3. AN ALARM SIGNAL SHALL BE SENT TO THE P:`�_--' _. 4. A SIGNAL SHALL BE SENT TO THE OWNERS CENTRAL STATION VIA DACT. UPON ACTIVATION OF ANY AUTOMATIC DEVICE THE FOLLOWING SHALL OCCUR: 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED._"' 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS RESET 3. AN ALARM SIGNAL SHALL BE SENT TO THE-FA°L 4. A SIGNAL SHALL BE SENT TO THE OWNERS CENTRAL STATION VIA DACT. UPON ACTIVATION OF THE ELEVATOR LOBBY SMOKE DETECTORS (WITH THE EXCEPTION OF THE ELEVATOR LOBBY DETECTOR AT THE PRIMARY LEVEL OF EGRESS), THE FOLLOWING SHALL OCCUR: 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED:` 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS. RESET. - 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP. © 2010 MEP ENGINEERING DESIGNS Inc. HEREBY RESERVE THEIR COPYRIGHTS TO THE IDEAS AND DRAWINGS SHOWN. THESE DRAWINGS ARE TO BE USED FOR THE PROJECT STATED ONLY AND SHALL NOT BE USED OR REPRODUCED FOR ANY OTHER PURPOSE WHATSOEVER WITHOUT THE EXPRESSED WRITTEN CONSENT. CONTRACTORS SHALL VERIFY ALL DIMENSIONS AND SHALL NOT RELY ON SCALED DIMENSIONS. NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO COMMENCING WORK. 4. A SIGNAL SHALL BE SENT TO THE OWNERS UL LISTED CENTRAL STATION VIA DACT. FA - 5. ELEVATORS SHALL RECALL TO THE PRIMARY LEVEL OF EGRESS. SECOND FLOOR PLAN AND ELEVATOR DIAGRAM FA -2 6. FIREHAT IN ELEVATOR CAB SHALL ILLUMINATE. FA -3 BATTERY CALCULATION UPON ACTIVATION OF THE ELEVATOR LOBBY SMOKE DETECTOR AT THE PRIMARY LEVEL PENETRATION DETAILS, DEVICE MOUNTING. DETAILS & WIRE GAGE RESISTANCE TABLE OF EGRESS, THE FOLLOWING SHALL OCCUR: 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS RESE -T: " 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP. 4. A SIGNAL SHALL BE SENT TO THE OWNERS UL LISTED CENTRAL STATION VIA DACT. W 5. ELEVATORS SHALL RECALL TO THE ALTERNATE LEVEL OF EGRESS. F- 6. FIREHAT IN ELEVATOR CAB SHALL ILLUMINATE. O z UPON ACTIVATION OF THE ELEVATOR MACHINE ROOM SMOKE DETECTOR, THE FOLLOWING SHALL OCCUR: 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. W W 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS RESET: 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP -, co W 4. A SIGNAL'SHALL BE SENT TO THE 0)NNER L LISTED CENTRAL STATION VIA DACT. 5. ELEVATORS SHALL RECALL TO THE P eLEVEL OF EGRESS. 4, U) 6. FIREHAT IN ELEVATOR CABS; TALL BLINK. , UPON ACTIVATION OF AN ELEVATOR MACHINE ROOM HEAT DETECTOR, THE FOLLOWING CC 0 G SHALL OCCUR: Z 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS RESET:° ..I 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP. W Q 4. A SIGNAL SHALL BE SENT TO THE OWNERS CENTRAL STATION VIA DACT, w W 5. THE ELEVATOR POWER CIRCUIT BREAKER SHALL TRIP TO THE OFF POSITION. 6. THE ELEVATOR SHALL REMAIN WITHOUT POWER UNTIL ALARM IS CLEAR AND FIRE ALARM ~ SYSTEM IS BACK TO NORMAL. _ w V LI w z UPON ACTIVATION OF A WATERFLOW SWITCH, THE FOLLOWING SHALL OCCUR: V) 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED'.- r, 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS RESET. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP: ` 4. A SIGNAL SHALL BE SENT TO THE OWNERS CENTRAL STATION VIA DACT. 5. FLOW BELL SHALL SOUND UPON ACTIVATION OF FLOW SWITCH ONLY. 6. FLOW BELL SHALL SOUND AS LONG AS WATER IS FLOWING. 7. FLOW BELL SHALL NOT BE CAPABLE OF BEING SILENCED FROM FACP. UPON ACTIVATION OF A TAMPER SWITCH, THE FOLLOWING SHALL OCCUR: m 1. A SUPERVISORY SIGNAL SHALL BE SENT TO THE FACP. $ 2. A SUPERVISORY SIGNAL SHALL BE SENT TO THE OWNERS CENTRAL STATION VIA DACT. UPON ACTIVATION OF A DUCT SMOKE DETECTOR, THE FOLLOWING SHALL OCCUR: L.L 1. A SUPERVISORY SIGNAL' SHALL BE SENT TO THE FACP. Q 2. A SUPERVISORY SIGNAL SHALL BE SENT TO THE OWNERS CENTRAL STATION VIA DACT. 3. THE AIR HANDLER UNIT ASSOCIATED WITH THAT DUCT DETECTOR SHALL SHUT DOWN. � � � co UPON ANY TROUBLE CONDITION IN THE FIRE ALARM SYSTEM: w W O 1. THE TROUBLE L.E.D. SHALL ILLUMINATE TROUBLE L.E.D. AND SOUND THE BUZZER AT CONTROL PANEL. co O 2. IT SHALL DISPLAY DEVICE AND LOCATION. " ) (D t 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP. Z 0 Z U- 4. A SIGNAL SHALL BE SENT TO THE OWNERS CENTRAL STATION VIA DACT, o ZO W c Q FIRE ALARM WIRE LEGEND � A- 18/2 AWG FIRE POWER LIMITED (FPL) OR THHN WIRE FOR INITIATING$E ; B- 14/2 AWG OR THHN WIRE FOR HORN /STROBE DEVICES.`' E . C- 18/2 AWG FOR DATA COMMUNICATION, D 18/2 AWG FIRE POWER LIMITED (FPL) 24 VOLT POWER. ,. { E- 16/2 AWG SHIELDED FPLR OR THHN WIRE FOR SPEAKERS. ti - F- 12 AWG THHN WIRE FOR FACP & POWER SUPPLY POWER. F G- 12 AWG THHN WIRE FOR FACP & POWER SUPPLY GROUND. FIRE ALARM SHEET INDEX FA COVER AND SYSTEM NOTES FA -1 SECOND FLOOR PLAN AND ELEVATOR DIAGRAM FA -2 FIRE ALARM SYSTEM RISER DIAGRAM FA -3 BATTERY CALCULATION FA-4 PENETRATION DETAILS, DEVICE MOUNTING. DETAILS & WIRE GAGE RESISTANCE TABLE ti N a F :REVISION DATE(S) "0 A A PROJ, NO: DATE: SHEET NO.: FA 1 Of 5 Sheets