09-424-025w E! ffi ::;E Gn pi Z J Z (if F- z �W W d Z E- o N O Z� CEI W2-JN W U�'-•vz= Shoo_,,., w0 Jv7� N♦ =a�l� O U O 0 �� -z_0- ~ w ° w W CD CL :n FA Cr �UiZOO- (A¢NWW z _J z W Ku M Nn °Lj� rr UJ W�WCLJ �JF•= -d'2 O¢Oa.cn FIXTURE \ ITEM WATER CLOSET I \ LAVATORY I \�� KITCHEN SINK \ REFRIGERATOR FLOOR DRAIN LAV / 3" FD W/TRAP SEAL I � w� I I �r �I 5 - '2J CONNECTION WASTE & SOIL 3' 1-1/2" 3 F.U. 4 1 2 N/A 2 REFER TO 'GENERAL CONDITIONS FOR RENOVATION" SANITARY SEWER RISER Scale:NTS 5HOCK <1 I I I �� � •'yam 5f� I I I I I I I I I dsI �4 I •. \`tip .z��. I I I I I REFER TO 'GENERAL CONDITIONS FOR RENOVATION" I (s *) FINAL LINE DIM. BASE ON WC SELECTION BY OWNER DOMESTIC WATER RISER S�le:NTs * GENERAL CONDITIONS FOR RENOVATIONS 1 -THE PLUMBING CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO BID AND VERIFY ALL CONDITIONS, LOCATION, DIMENSIONS, MATERIALS, ELEVATIONS AND COUNTS AS SHOWN AND /OR NOTED ON THE DRAWINGS AND INCLUDE IN THE BID ANY AND ALL FABRICATION REQUIRED PRIOR TO INSTALLATION.THE CONTRACTOR SHALL VERIFY SIZE, ELEVATION AND PRESENT STATE OF ALL EXISTING UTILITIES, AND SHALL NOTIFY ENGINEER IF PIPE SIZE CHANGES ARE REQUIRED BECAUSE OF EXISTING CONDITIONS. 2 -THE PLUMBING CONTRACTOR SHALL DETERMINE THE EXTENT TO WHICH EXISTING PIPING WILL HAVE TO BE REROUTED, RELOCATED, OR RECONNECTED, AND THE AMOUNT OF ADDITIONAL WORK WHICH MAY BE REQUIRED DUE TO THE PHYSICAL CONDITIONS OF THE PIPING SHALL BE PERFORMED UNDER THIS CONTRACT WITHOUT ADDITIONAL CHARGES TO THE OWNER. 3 -THE CONTRACTOR SHALL COORDINATE HIS WORK WITH THE ACTUAL DIMENSIONS AND ROUGH -IN LOCATIONS FOR THE EQUIPMENT BEING REUSED. 4- PLUMBING EQUIPMENT THAT IS TO REMAIN IN AREAS WHERE THE INSTALLATION WILL INTERFERE WITH THE INSTALLATION OF NEW EQUIPMENT OR NEW ARCHITECTURAL CHANGES , SHALL BE REMOVED, RELOCATED, OR RE- ROUTED TO PERMIT COMPLETION OF SUCH WORK. SCHEDULE WATER COLD HOT 1/20 - - 1/2' 1/2' 1/2' 1/2" 1/20 - - TRAP SEAL - - I I I I i I I �pS �J Rt;F n 5- SALVAGED MATERIALS, EQUIPMENT, AND PLUMBING FIXTURES SHALL BE DELIVERED TO THE OWNER AT HIS PROPERTY AND STORED WITHIN THE BUILDING WHERE DIRECTED. ANY REMOVED MATERIALS OR EQUIPMENT WHICH THE OWNER DOES NOT WISH TO KEEP SHALL BE DISPOSED OF BY THE CONTRACTOR, WITHOUT ADDITIONAL COST TO THE OWNER. 6 -ALL PRESENT PIPING IN EXISTING AREAS TO BE ALTERED, WHICH WILL HAVE NO USE UPON COMPLETION OF THE ALTERATIONS SHALL BE REMOVED. PIPING WHICH IS OR WILL BECOME EXPOSED TO VIEW, OR WILL INTERFERE WITH THE INSTALLATION AND COMPLETION OF THE WORK REQUIRED, SHALL BE RELOCATED. PIPING SHALL NOT BE RUN EXPOSED THROUGH EXISTING OR NEW FINISH SPACE UNLESS WRITTEN PERMISSION IS GRANTED BY THE OWNER. 7- INTERRUP1ION OF EXISTING FACULTIES OR SERVICES SHALL BE KEPT TO A MINIMUM AND THE CONTRACTOR SHALL FURNISH ALL MATERIALS AND LABOR REQUIRED WHENEVER TEMPORARY CONDITIONS ARE NECESSARY TO MAINTAIN CONTINUITY OF SERVICE.INTERRUPTION OF SERVICES, THE INSTALLATION OF TEMPORARY FACILITIES, AND THE WORK OF MAKING FINAL CONNECTIONS TO NEW WORK SHALL BE DONE ONLY AT SUCH TIMES AS PERMITTED AND SCHEDULED BY THE OWNER WITHOUT ADDITIONAL COST.THE PLUMBING CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE THE SERVICE INTERRUPTIONS WITH THE OWNER AND GENERAL CONTRACTOR. PLUMBING RISER AND DETAILS Scale: NTS PROJECT NOTES —ALL DISCONNECTED PLUMBING LINES FOR EXISTING FIXTURES SHALL BE CAPPED.NO LINES SHALL REMAIN OPEN TO THE ATMOSPHERE — INSTALL A WATER HAMMER ARRESTER FOR EACH PLUMBING FIXTURE SUPPLY BRANCH USING TABLE (2/P -2) — INSTALL A SHUTOFF VALVE ON THE FIXTURE SUPPLY TO EACH PLUMBING FIXTURE. —THE INSTALLATION OF ANY PART OF PLUMBING SYSTEM SHALL BE ACCORDING TO FBC —P SECTION 307 —ANY PLUMBING LINES WHICH REQUIRE REMOVAL AND /OR ALTERATION, G.C. SHALL CAP AND FILL SLAB WITH SAME FIRE RATED INTEGRITY. - PROVIDE METAL SLEEVE AT ALL WALL AND SLAB PENETRATIONS. -ALL HORIZONTAL DRAIN PIPE 2 "- OR SMALLER SHALL BE SLOPED AT 1 /4 " /FT -ALL HORIZONTAL DRAIN PIPE FROM 3" TO 6" SHALL BE SLOPED AT 1 /8 " /FT MIN. -ALL HORIZONTAL DRAIN PIPE B" OR LARGER SHALL BE SLOPED AT 1 /16 " /FT MIN - PROVIDE AUTOMATIC TRAP RESEAL FOR ALL FLOOR DRAINS $CONNECT NEW LINES TO EXISTING, VERIFY EXACT LOCATION,SIZE & CAPACITY IN FIELD PRIOR TO BID THE PROJECT. NOTIFY ARCHITECT & ENGINEER OF ANY DISCREPANCIES. CONTRACTOR IS STRONGLY ENCOURAGE TO PERFORM A VISIT TO VERIFY ALL CONDITIONS THAT MAY AFFECT THE SCOPE OF WORK.CONTRACTOR NOT PERFORMING A SITE VISIT ARE ACKNOWLEDGING AND ACCEPTING ALL SITE CONDITIONS AS THEY EXIST. VERIFY.-POINTS OF CONNECTIONS; EXISTING LINES ( SIZE, CAPACITY,MATERIALS, ....) -ALL PLUMBING WORK PERFORMED UNDER THIS CONTRACT SHALL COMPLY WITH LOCAL CODES AND ORDINANCES AND ALL STANDARDS OF CONSTRUCTION ESTABLISHED BY THE LANDLORD. - SUBMIT SHOP DRAWINGS FOR ACCEPTANCE BY THE ARCHITECT AND /OR ENGINEER BEFORE PROCEEDING WITH THE PURCHASE OR INSTALLATION OF THE EQUIPMENT AND MATERIALS. NO FACSIMILES OR FACSIMILE COPIES SHALL BE ACCEPTED. -IF ANY CONFLICT IS ENCOUNTERED WITHIN THE DESIGN DOCUMENTS, REGARDLESS OF TRADE OR RESPONSIBILITY, THE GREATER SCOPE OF WORK SHALL PREVAIL. THESE PLANS ARE FOR BUILDING DEPARTMENT REVIEW ONLY. THEY ARE NOT TO CONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENT APPROVALS ARE OBTAINED. - CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS BEFORE PROCEEDING WITH WORK.IF ANY DISCREPANCIES,ERRORS OR OMISSIONS ARE ENCOUNTERED ON PLANS, CONTRACTOR SHALL NOTIFY ARCHITECT/ ENGINEER BEFORE ANY PART OF THE WORK IS STARTED SO THAT PROPER CORRECTIONS BE MADE. IF ARCHITECTS /ENGINEER IS NOT NOTIFIED PRIOR TO COMMENCING OF THE WORK, THE CONTRACTOR SHALL BEAR FULL RESPONSIBILITY FOR ANY DISCREPANCIES , ERROR OR OMISSIONS. INSTALL PER PDI STANDARDS AND MANUFACTURER'S INSTRUCTIONS. PROVIDE A NA AT ALL QUICK CLOSING VALVES. SINGLE/DOUBLE FIXTURE HOT OR COLD WATER SUPPLY IF HORIZONTAL BRANCH IS LESS THAN 20' LONG, PROVIDE ONE MA AT THE END OF LINE IF BRANCH IS GREATER THAN 20' LONG, PROVIDE ANOTHER WHA IN MIDDLE, EACH SIZED FOR HALF THE FIXTURE UNITS. I MULTIPLE FIXTURE HIDROTROL PDI SIZE PIPE SIZE FIXTURE UNIT LOAD FIXTURE UNIT TABULATON FIXTURE COLD HOT 5005 A 1/2" 1 -11 VALVE WATER CLOSET 10 - 5010 B 3/4" 12 -32 TANK WATER CLOSET 5 - 5020 C 1' 33 -60 URINAL 5 - 5030 D 1-1/4" 61 -113 LAVATORY /SINK 1.5 1.5 5040 E 1 -1/2" 114 -154 JANITOR'S SINK 3 3 5050 F 2" 155 -330 SHOWER /BATHTUB 2 2 FOR BATTERIES OF FIXTURES , PROVIDE WATER HAMMER ARRESTERS BY SIOUX CHIEF, PRECISION PLUMBING PRODUCTS, WATTS OR APPROVED EQUIVALENT WITH PISTON AND 0 -RING CONSTRUCTION , HAVING PDI # MA-2001, ASSE # 1010 AND ANSI J A11126.1M CERTIFICATION , INSTALL IN HORIZONTAL OR VERTICAL POSITION , BUT NEVER UPSIDE DOWN. THE DRAWING AND /OR PER THE TABLES SHOVE ABOVE. PROVIDE ACCESSIBILITY TO "WHA" WHERE REQUIRED BY LOCAL CODE WATER HAMMIER ARRESTERS HANG PIPE LARGER THAN 4' FROM TOP OF JOISTS ONLY AT PANEL POINT C- CLAMP, CONNECT TO TOP OF BEAM OR STEEL BAR JOIST ADJUSTABLE BAND HANGER FOR PIPE 3 -1/2" AND SMALLER AND CAST IRON PIPE 2" AND SMALLER a 0 z z IL w IL V) acn N W W J w w CL a0 STEEL DECK ALL— THREAD ROD - PROVIDE COPPER COATED HANGERS WHERE HANGERS CONTACT BARE COPPER PIPE INSTALL REINFORCING WIRE TO INSERT IN NEW CONCRETE CONSTRUCTION. CONCRETE SLAB DRILLED —IN THREADED INSERT FOR EXISTING ' CONCRETE SLAB OR CAST IN PLACE FOR NEW CONCRETE CONSTRUCTION. DO NOT USE SHOT —IN INSERTS. LEVIS HANGER FOR PIPE 4" AND LARGER AND CAST IRON PIPE 3" AND LARGER a Li oa Rz PROVIDE GALVANIZED STEEL SHEILD FOR ALL INSULATED PIPE. VERIFY a cox V) 3: INSULATION THICKNESS WHEN SIZING HANGERS AND SHIELDS. 1/2w 5' 7' 3/4' 5 7' 1" 6' T 1-1/4w 7' 8' 1 -1 /2' 8' 9' 2" 8' 10' 2-1/2n 10' 11' 3" 11' 12' 4" OPIPE HANGERS N.T.S. PROVIDE UPPER ATTACHMENT AS REQUIRED FOR CASES NOT SHOWN HERE. DO NOT INSTALL HANGER INSIDE INSULATION OR OTHERWISE PENETRATE VAPOR BARRIER. DO NOT HANG ONE PIPE FROM ANOTHER EXCEPT IN CHASES. SLOPEALL WATER PIPING SLIGHTLY TOWARD DRAINABLE LOCATIONS. HANGER SPACING FOR PIPE SIZE: AS' INDICATED ON TABLE. CAST IRON: 10' AND WITHIN V -0' OF ALL JOINTS. ROD SIZES FOR PIPE SIZE: 2' AND SMALLER =3/8 ", 2 1/2" TO 3' =1/2 4' =5J8', 6' =3/4 8' AND LARGER =7/8 ". LOCATE HANGERS WITHIN 1' -0 OF VALVES AND FITTINGS. PROVIDE SUPPLEMENTARY STEEL STRUTS BETWEEN JOISTS IF REQUIRED. LOCATE HANGERS WITHIN 1' -0' OF EQUIPMENT CONNECTIONS. ANCHOR WATER PIPE AGAINST SWAYING DUE TO CHANGES IN WATER VELOCITY. - CHAINS AND PERFORATED STRAP IRON AND STEEL ARE NOT ACCEPTABLE. DO NOT SUSPEND PIPE FROM JOIST BRACING MEMBERS. REFER TO CODES AND SPECS FOR FURTHER INFORMATION. PROVIDE SEISMIC BRACING IF /AS REQUIRED BY LOCAL AUTHORITIES. TRAPEZE HANGERS MAY BE USED FOR MULTIPLE PARRALLEL PIPES, SEE 'TRAPEZE PIPE HANGER DETAIL.' FAUCET FLOW CONTROL I HOT WATER OUTLET HOT WATER HEATER ELECTRICAL SUPPLY "HOT' VALVE 'COLD" VALVE COPPER TUBING SINK MAIN PIPE COLD WATER INLET - SOV LAVATORY WATER AND ALL DRAINING PIPING SHALL BE INSULATED OR PROTECTED FROM CONTACT. THE INSTANT HOT WATER HEATER SHALL NOT HAVE ANY SHARP EDGE OR ABRASIVE SURFACES , HOT WATER HEATER SHALL BE PROTECTED FROM CONTACT. 0 INSTANT ELECT WATER HM N.T.S i FLOOR CLEANOUT.(F.C.0.) C.O. NOT TO BE LOCATED IN CARPETED AREA. O MAY EXTEND AS A WASTE OR VENT. REFER TO PLANS. 2O CHROME WALLCOVER & SCREW. O WALL 4O PLUGGED TEE W /CLEANOUT. 5O FLOOR LINE GRADE CLEANOUT (G.C.O.) O 1/8" C.I. BEND 7O BALANCE OF PIPING SAME AS CLEANOUT TO GRADE. 8O CLEANOUT & ACCESS COVER TO BE FLUSH W/TOP OF FLOOR. 9O BALANCE OF PIPING SAME AS CLEANOUT TO GRADE. 10 BRASS CLEANOUT PLUG W /COUNTER SUNK HEAD. 11 FINISH GRADE 12 16' SQUARE CONC. PAD TROWEL SMOOTH AND EDGE. 13 C.I. WASTE LINE. LENGTH TO SUITE. 14 WASTE LINE 15 1/8 BEND IF CLEANOUT OCCURS AT END OF UNE. OCLEANOUT DETAILS N.T.S. MAKE 1/2" BRANCH TO TRAP PRIMER OFF TOP OF DOMESTIC COLD WATER BRANCH PIPE TO FIXTURE(S). INSULATE PIPE UPSTREAM OF TRAP PRIMER, BUT NOT DOWNSTREAM. LOCATE TRAP PRIMER WHERE AN ACCESS DOOR (REFER TO SPECIFICATIONS) CAN BE PLACED IN FRONT OF IT IN AN ACCESSIBLE LOCATION. INSTALL PRIMER MINIMUM 6" ABOVE FLOOD RIM OF FIXTURE BEING SERVED. PROVIDE FLOOR DRAIN BODY OR P -TRAP WITH THREADED TRAP_ PRIMER CONNECTION. PROVIDE FITTINGS AND ADAPTERS AS REQUIRED TO MAKE WATER -TIGHT CONNECTION TO DRAIN. AUTOMATIC TRAP PRIMER VALVE WITH INTVGRAL AIR GAP. PROVIDE DISTRIBUTION UNIT(S) WHERE MORE THAN ONE TRAP IS SERVED BY ONE TRAP PRIMER VALVE. INSTALL TRAP PRIMER LINES DOWNSTREAM OF TRAP PRIMER OR DISTRIBUTION UNIT USING 1/2" TYPE "K" SOFT COPPER TUBING. INSTALL WITHOUT KINKS, AND SLOPE CONTINUOUSLY TOWARDS FLOOR DRAIN. CONCRETE FLOOR IF PIPE IS BELOW FLOOR SLAB ON GRADE, PROVIDE 1/2' ELASTOMERIC INSULATION FROM PRIMER CONNECTION TO 1" ABOVE FLOOR SLAB. PROVIDE TRAP PRIMERS WHERE SHOWN ON FLOOR PLANS, AND WHERE REQUIRED BY LOCAL AUTHORITIES. PIPING ARRANGEMENT SHOWN IS SCHEMATIC: ADJUST TO SUITE AUTHORITIES AND FIELD CONDITIONS. REFER TO SPECIFICATIONS AND PLUMBING FIXTURE SCHEDULE FOR MORE INFORMATION. OTRAP PRIMER IN WET WALL N.T.S. 151 SEVILLA AVENUE, SUITE 200' _ _ _ - CORAL GABLES, FL 33134 OFFICE: (305) 442 -1188 FAX: (305) 445 -1509 VVVVW. ADCINTERNATIONAL.NET STATE OF FLORIDA AR- 0010536 RAYMUNDO FEITO, R.A. AA— CO01315 Architect • Seal/SignaWre MRA EXPANSION SUNSET PROFESSIONAL BLDG 8280 SUNSET DR SUITE 600 SOUTH MIAMI FL Key Plan - Scope of Work Area /Z KEY PLAN LEGEND AREA AT WHICH �}/ I THE SCOPE OF WORK WILL BE PERFORMED. N.I.C. AREA CONSTRUCTION NOTE THE CONTRACTOR, BY VIRTUE OF " SIGNING THE CONTRACT, ACKNOWLEDGES THATHEAND Z ALL HIS SUBCONTRACTORS HAVE _ SATISFIED THEMSELVES AS TO Z ~ i , *; THE NATURE AND LOCATION OF THE WORK THE GENERAL AND LOCAL CONDITIONS INCLUDE, BUT IL ARE NOT RESTRICTED TO THOSE W BEARING UPON; ACCESS POINTS AND POINTS OF CONNECTION TO Q THE SITE; THE CONFORMATION a f AND CONDITIONS OF THE WORK N r AREA; AND THE CHARACTER OF • EQUIPMENT AND DEVICES NEEDED Z PRELIMINARY TO AND DURING THE C9 I PERFORMANCE OF THE WORK N FAILURE ON THE PART OF THE W CONTRACTOR TO COMPLETELY OR PROPERLY EVALUATE ANY [� FACTORS OF COSTS PRIOR TO 0 v,. a BIDDING SHALL NOT FORMA BASIS 4" FOR ADDITIONAL COMPENSATION LLI IF HE IS AWARDED THE CONTRACT. h- ? Date & Issue Description Drawn By Checked By • Z_ Z Z g CL LU W V Q Date & Issue Description Drawn By Checked By Project Number Client Name 09032 PROI"ED FIRZMR11M Description Client Address PLUMBING RISER 8 DETAILS 16% NE MIAMI GARDENS DR SUITE 8 Scale K MIAMI BEACH, FL 33119 AS SHOWN Client Phone Number (305) 941 -8800 CAD File Name C:JPr0Jecte1ob22W9tJADC1 /2MRA EXPANSION Consultant • Seal/Signature ENGINE RING Z DESIG , GRO . z 21 SW 102 Ct. Miami, :. Office: (786) 863- 1 • • . Fax: (305) 22 -5196 J pgengineerdesign®bellsouanet D J P=4mO STATE OF FLORIDA LUIS O. PEREZ, PE P.E. No. 62586