GENERAL PLUMBING NOTES
1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE,AND ALL APPLICABLE LOCAL ORDINANCES.
2. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE
COMPLETE SYSTEM SHALL BE FULLY OPERATIVE AFTER COMPLETION OF WORK.
3. PLUMBING CONTRACTOR SHALL FURNISH WRITTEN GUARANTEE THAT ALL PLUMBING WORK SHALL BE FREE OF DEFECTS OF
MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM FINAL ACCEPTANCE.
4. CONTRACTOR SHALL VISIT THE SITE AND THOROUGHLY FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS. FIELD VERIFY LOCATION
OF EXISTING POINTS OF CONNECTIONS BEFORE SUBMITTING BID. OBTAIN ANY REQUIRED CLARIFICATION BEFORE COMMENCING WORK.
5. WHERE INDICATED OR REQUIRED, EXISTING SYSTEM COMPONENTS SHALL BE CAREFULLY REMOVED OR RELOCATED. EACH RESULTING
OPENING IN THE BUILDING CONSTRUCTION SHALL BE PROPERLY PATCHED AND FINISHED WITH THE SAME MATERIALS AS THOSE
ADJACENT TO THE OPENING.
6. COORDINATE NEW PLUMBING WORK WITH LIGHTING, ELECTRICAL, DUCTWORK,STRUCTURAL FRAMING AND CEILING SYSTEMS.
7. CONTRACTOR SHALL BECOME FAMILIAR WITH ALL EXISTING CONDITIONS AND NOTIFY ARCHITECT /ENGINEER OF ANY DEVIATION DUE
TO FIELD CONDITIONS BEFORE COMMENCING WORK.
8. CONTRACTOR SHALL COORDINATE LOCATION AND SIZE OF ALL PENETRATIONS THROUGH WALLS, CEILINGS, FLOORS AND ROOFS WITH
OTHER TRADES AND REPORT ANY DISCREPANCIES TO ARCHITECT /ENGINEER.NO STRUCTURAL MEMBER SHALL BE CUT OR MODIFIED
WITHOUT WRITTEN AUTHORIZATION.
9. DRAWING ARE DIAGRAMMATIC. DO NOT SCALE DRAWINGS FOR EXACT LOCATION OF FIXTURES AND PIPING.
10. CONTRACTORS SHALL BE RESPONSIBLE FOR ALL PERMITS, TAXES, INSPECTIONS AND TEST FEES.
11. ALL MATERIALS TO BE PROVIDED UNDER THIS DOCUMENTS SHALL MEET ALL THE REQUIREMENTS OF THE F.P.C, AND ALL OTHER
LOCAL STANDARDS AND REGULATIONS. MATERIALS SHALL BE NEW, FREE OF DEFECTS AND OF AMERICAN MANUFACTURER,
INDELIBLY MARKED WITH MANUFACTURER NAME, WEIGHT AND /OR CLASS. MANUFACTURER NAMES SHALL BE INTERPRETED AS
ESTABLISHMENT OF REQUIRED TYPE, CLASS AND QUALITY. MATERIAL SHALL BE PROVIDED AS FOLLOWS:
A. ALL WASTE, VENT, AND STORM PIPING BELOW GRADE SHALL BE ONE OF THE FOLLOWING TYPES (AS PER TABLE- 702.2, F.P.C.)
A.1 SERVICE WEIGHT CAST IRON, SOIL PIPE. PIPING AND FITTINGS SHALL CONFORM TO THE REQUIREMENTS OF CISPI STANDARD
301, ASTM A -888 OR ASTM A- 74,LATEST ISSUE.
A.2 BELL AND SPIGOT SERVICE WEIGHT CAST IRON, WITH LEAD AND OAKUM, OR GASKETED JOINTS. PIPING AND FITTINGS SHALL
CONFORM TO THE REQUIREMENTS OF CISPI STANDARD 301, ASTM A -888 OR ASTM A -74, LATEST ISSUE.
A.3 SCHEDULE 40 ABS OR (DWV) PCV PIPING. FOR BUILDINGS EXCEEDING 3- STORIES IN HEIGHT, UNDERGROUND DRAINAGE
PIPING SHALL BE SERVICE WEIGHT CAST IRON AS PER SECTION A.1.
B. ALL WASTE, VENT, AND STORM PIPING ABOVE GRADE SHALL BE ONE OF THE FOLLOWING TYPES (AS PER TABLE - 702.1, F.P.C.)
B.1 SERVICE WEIGHT CAST IRON SOIL PIPE. PIPING AND FITTINGS SHALL CONFORM WITH THE REQUIREMENTS OF CISPI STANDARD
301, ASTM A -888 OR ASTM A -74.
B.2 BELL AND SPIGOT, 'NO HUB' SERVICE WEIGHT CAST IRON, OR WROUGHT IRON, WITH SEALING SLEEVES AND STAINLESS STEEL
COUPLING JOINTS, CLAMPS AND BOLTS.PIPING AND FITTINGS SHALL CONFORM WITH THE REQUIREMENTS OF CISPI STANDARD
301, ASTM A -888 OR ASTM A -74, LATEST ISSUE.
B.3 SCHEDULE 40 ABS OR (DWV) PCV PIPING. NO COMBUSTIBLE PIPING SHALL BE LOCATED IN RETURN AIR PLENUM.
C. SANITARY PIPE FITTINGS:
CA JOINTS FOR HUBLESS PIPE AND FITTING SHALL CONFORM EITH THE F.P.C. AND THE MANUFACTURER'S INSTALLATION
INSTRUCTIONS AND LOCAL CODE REQUIREMENTS. HUBLESS COUPLINGS SHALL CONFORM TO CISPI 301. JOINTS FOR HUB AND
SPIGOT PIPE SHALL BE INSTALLED WITH COMPRESSION GASKETS CONFORMING TO THE REQUIREMENTS OF ASTM STANDARD
C -564 OR SHALL BE INSTALLED WITH LEAD AND OAKUM.
D. DOMESTIC WATER PIPING AND FITTINGS SHALL CONFORM WITH TABLES 605.4 through 605.8. OF THE F.P.C. AND SHALL BE ONE
OF THE FOLLOWING TYPES:
D.1 COPPER TYPE 'L' ABOVE GROUND AND COPPER TYPE 'K' BELOW GROUND CONFORMING WITH ASME B -88, AND ASTM B -16,
LEAD - FREE SOLDER. DOMESTIC WATER PIPING SHALL NO BE INSTALLED BELOW SLAB, UNLESS INDICATED OTHERWISE ON
THESE DRAWINGS
D.2 PROVIDE WATER HAMMER ARRESTOR 18" HIGH, NEXT LARGE SIZE THAN PIPE SERVING FIXTURE.
D.3 INSULATE ALL HOT WATER PIPING WITH 1" RIGID FIBERGLASS OR 1/2" THICK FLEXIBLE FOAM INSULATION
(ARMAFLEX). FLEXIBLE FOAM INSULATION SHALL NOT BE SPLIT, AND SHALL BE TAPED AT BUTT JOINTS.
E. WALL CLEANOUTS.
EA JOSAM SERIES 58750 WITH ACCESS COVER OR EQUAL.
E.2 PROVIDE CHROME PLATED BRASS ESCUTCHEONS WITH LOCKING SCREWS WHERE PIPE PASS THROUGH FINISHED WALLS.
E.3 A CLEANOUT SHALL BE PROVIDED AT THE BASE OF EACH SOIL AND WASTE STACK.
F. VALVES.
F.1 QUATER TURN BALL VALVES, RATED FOR 125 PSI. MANUFACTURED BY NIBCO, SCOTT, STOCKHAM OR EQUAL.
F.2 PROVIDES STOPS AT ALL PLUMBING FIXTURES. EXPOSED STOPS SHALL BE CHROME PLATED.
G. PLUMBING FIXTURES.
G.1 SEE PLUMBING FIXTURE SCHEDULE FOR FIXTURE SPECIFICATIONS.
G.2 PLUMBING FIXTURES SHALL COMPLY WITH WATER CONSERVATION REGULATION FS.553.14.
G.3 EXPOSED HOT WATER PIPING SERVING PLUMBING FIXTURES SHALL BE PROPERLY INSULATED.
12. PERFORM THE FOLLOWING TEST-
A. NEW DOMESTIC WATER PIPING SHALL BE HYDROSTATICALLY TESTED AT 100 PSIG FOR A PERIOD OF NO LESS THAN ONE HOUR.
B. WASTE AND VENT PIPING SHALL BE FILLED WITH WATER TO A 10 FOOT HEAD AND ALLOWED TO STAND UNTIL THE WATER
LEVEL REMAINS CONSTANT.
C. CORRECT ALL DEFECTS DISCLOSED BY ABOVE TESTING.
D. NEW OR REPAIRED POTABLE WATER SYSTEMS SHALL BE PURGED OF DELETERIOUS MATTER AND, WHERE REQUIRED BY THE
ADMINISTRATIVE AUTHORITY, DISINFECTED PRIOR TO UTILIZATION.THE METHOD TO BE FOLLOWED SHALL BE THAT PRESCRIBED
BE THE HEALTH AUTHORITY OR WATER PURVEYOR HAVING JURISDICTION OR, IN THE ABSENCE OF A PRESCRIBED
METHOD , THE PROCEDURE DESCRIBED IN EITHER AWWA C651 OR AWWA 652, OR AS DESCRIBED IN SECTION 610 FPC 2004.
13. WASTE PIPING 2 1/2" AND SMALLER SHALL BE SLOPED AT 1/4" PER FOOT MINIMUM.PIPES LARGER THAN 2 1/2" SHALL BE SLOPED
AT 1/8" PER FOOT MINIMUM FALL.
14. INSULATE ALL AIR CONDITIONING AND REFRIGERATION CONDENSATE DRAIN WITH 3/4" INCOAFLEX PIPE INSULATION OR EQUAL.
FINISHED, WHERE EXPOSED, WITH 2 COATS OF WHITE LATEX PAINT AS PER MANUFACTURER'S INSTRUCTION.
15. PIPING PENETRATION AT ROOFS, CEILINGS, FLOORS AND WALLS SHALL BE SEALED AIR AND WATER TIGHT. WHERE PENETRATING FIRE
RATED CONSTRUCTION, FIRE SAFE TO PROVIDE PROTECTION MATCHING REQUIRED FIRE RESISTANCE RATING.
16. ALL HORIZONTAL VENT PIPING SHALL SLOPE TO DRAW TO STACKS. NO POCKETS OR LOW POINTS SHALL BE CREATED IN THE VENT
LINES WHICH MAY PREVENT VENTING IF FILLED WITH CONDENSATION.
17. CEILING ACCESS PANELS SHALL BE PROVIDED FOR VALVES INSTALLED ABOVE OTHERWISE NON- ACCESSIBLE CEILINGS.
18. NO EQUIPMENT OR MATERIALS SHALL BE PURCHASED OR INSTALLED PRIOR TO FINAL APPROVAL OF SHOP DRAWINGS.
19. THE CONTRACTOR SHALL PROVIDE A SET OF PRINTS CLEARLY MARKED TO SHOW AS -BUILT CONDITIONS AT THE COMPLETION OF
CONSTRUCTION.
20. FURNISH AND INSTALL DIELECTRIC COUPLINGS AT ALL CONNECTIONS BETWEEN DISSIMILAR METALS.
21. THE EXISTING PLUMBING LINES INDICATED OR NOTED ON THESE DRAWINGS, ARE SHOWN AS OBTAINED FROM EXISTING INFORMATION
OR SITE OBSERVATIONS, AND ARE ONLY APPROXIMATE IN LOCATION. THE CONTRACTOR SHALL VERIFY THESE LOCATIONS, CONNECTION
POINTS AND SIZES BEFORE PROCEEDING WITH WORK.
22. PRECAUTIONS SHALL BE TAKEN TO PREVENT CONTAMINATION OF OWNER EQUIPMENT, FURNITURE AND CARPETING WITHIN THIS
BUILDING. COVER AND WRAP EQUIPMENT, FURNITURE AND CARPETING AS NECESSARY. DUST AND DEBRIS SHALL BE STRICTLY
CONTROLLED. CLOSE COORDINATION WITH OWNER WILL BE REQUIRED.
23. WHERE REQUIRED, EXISTING CEILINGS SHALL BE REMOVED TO MODIFY THE EXISTING PLUMBING SYSTEMS. THESE CEILINGS SHALL BE
REPLACED TO MATCH ADJACENT SURFACES.
24. ALL DISCONNECTED PLUMBING LINES SHALL BE EITHER RECONNECTED OR CAPPED.NO LINES SHALL REMAIN OPEN TO THE
ATMOSPHERE.
25. IF CEILING SPACES ARE USED AS "RETURN AIR CEILING PLENUMS ", ALL MATERIALS INSIDE THE R/A PLENUM SHALL HAVE A
MAXIMUM FLAME SPREAD INDEX OF 25 AND A MAX SMOKE DEVELOPED INDEX OF 50 PER NFPA 90A.
"NO PVC PIPING IS ALLOWED INSIDE THE R/A PLENUM."
PLUMBING FLOOR PLAN (NEW SANITARY SEWER) � N
Scale: 74 " = 1'-0"
STATE OF FLORIDA AR- 0010536
RAYMUNDO FEITO, R.A. AA- CO01315
Architect • SeaUSignature
MRA EXPii \SION
SUNSET PROFESSIONAL BLDG
0280 SUNSET DR
SUITE 800
SOUTH MIAMI FL
Key Plan - Scope of Work Area
Z KPY PI AN I FCaFNn
AREA AT WHICH
€ THE SCOPE OF
WORK WILL BE
PERFORMED.
N.I.C. AREA
CONSTRUCTION NOTE
'
al
Z ;;:
Z " ""' "`
Z
THE CONTRACTOR, BY VIRTUE OF
SIGNING THE CONTRACT,
ACKNOWLEDGES THATHEAND
ALL HIS SUBCONTRACTORS HAVE
SATISFIED THEMSELVES AS TO
THE NATURE AND LOCATION OF
THE WORK. THE GENERAL AND
LOCAL CONDITIONS INCLUDE, BUT
a
ARE NOT RESTRICTED TO THOSE
W
V
pa„ "
f
.r • ;r
BEARING UPON, ACCESS POINTS
AND POINTS OF CONNECTION TO
THE SITE; THE CONFORMATION
AND CONDITIONS OF THE WORK
N
AREA; AND THE CHARACTER OF
•
f
EQUIPMENT AND DEVICES NEEDED
Z
PRELIMINARY TO AND DURING THE
C9
PERFORMANCE OF THE WORK.
(�
FAILURE ON THE PART OF THE
W
..:.
:;.
CONTRACTOR TO COMPLETELY OR
PROPERLY EVALUATE ANY
O
W
- •.
`` ;•;..•
FACTORS OF COSTS PRIOR TO
BIDDING SHALL NOT FORM A BASIS
FOR ADDITIONAL COMPENSATION
IF HE IS AWARDED THE CONTRACT.
I--
?
Date & Issue Description Drawn By Checked By
•
Z_
Z
Z
5
IL
•
W
F-
V
W
F-
2
V
Q
Date & Issue Description Drawn By Checked By
Project Number
Client Name
09032
t rIM PROPERTIES
Description
Client Address
PLUMBING SANITARY SEWER
1656 1`E MIAMI GARDENS, DR
SUITE 8
Scale
N. MIAMI BEAcw, FL 33119
AS SHOWN
Client Phone Number
(305) 941-WW
CAD File Name
C.:It Projects V2200SIlADCI
/2 MRA EXPANSION
Consultant • Seal/ Signature
ENGINFERING
Z
DESIG
GR
i• y, W G
ko
W
.w V ti
V 21 SW 102 Ct. Miami, F1.3 .
Z
Office: (786) 863 -7 f
m Fax: (305) 220 -5196
c pgengineerdesign ®bellsouth.net
P=2mOG
0. STATE OF FLORIDA
LUIS O. PEREZ, PE P.E. No. 62586