Loading...
09-424-021W Q� ° °tUJ < N V O Wz J z ~ < o w w o aWOf� ¢Z ;o �OZO:f UJ w�¢W s;O°w u NZE- C5 O U CD W° W WC - JC'c M C n U C n 0 � t of vi - v~iQViWW Z�w�� Z C) vi. 0- �� UJ Ln LU of Of W W d J UJ J O _ O ¢ O 0- N (1) SUITE 600 1 ELECTRICAL ROOM 6TH FLOOR NEW 4 #1/0 AND 1 #6 GND IN A 2" CONDUIT. NEW I I i PANEL I "M" I EXISTING I I DIST. PANEL I EXISTING 4 #500 MCM 120/208V I "MDP" I I WIRING. 30,4W I. 120/208V,30,4W I 400 AMPS MAIN I I I I I I I I I 6th FLOOR 1 st FLOOR MAIN ELECTRICAL ROOM I I I I TO FPL VAULT. r-- -J - - - - - -- II 400 A' I I I � I EXISTING I SWITCHBOARD I I I 120/208V,30,4W I 2000 AMPS MAIN I I (MAIN 1 OF 1) I L----------- J POWER RISER DIAGRAM NTS • LTS: 120/208 30, 4W MOUNTING: EXISTING -• 400 AMPS DISTRIBUTION -. MDP" SQUARE MAINS: 400 AMPS M.C.B (ELECTRICAL ROOM 6TH FLOOR) AIC: 42,000 THE CONTRACTOR, BY VIRTUE OF � o U Z DESCRIPTION -i IL 0 FE • w 3 zz OU CIRCUIT BREAKER DESCRIPTION -i a_ 0 Fr > °a OJ w zz 0 1 LIGHTING (BATHROOMS) 1 -20 1200 #12 EXIST. 2 1 LIGHTING (OPEN AREA) 1 -20 1600 #12 1/2" 3 LIGHTING ( BERAK RM, NURSE ST) 1 -20 1600 #12 1/2- o LIGHTING (OPEN /SUPPORT) 1 -20 �nanna�a��n #12 1/2" 5 LIGHTING (OPEN /SUPPORT) 1 -20 1600 #12 1/2" 6 LIGHTING (OPEN /SUPPORT) 1 -20 700 #12 1/2" 7 LIGHTING (OPEN /SUPPORT) 1 -20 1400 #12 1/2" 8 RECEPTACLES (OPEN /SUPPORT) 1 -20 720 #12 1/2" 9 RECEPTACLES (OPEN /SUPPORT) 1 -20 720 #12 1/2" 10 RECEPTACLES (OPEN /SUPPORT) 1 -20 720 #12 1/2" 11 RECEPTACLES (OPEN /SUPPORT) 1 -20 720 #12 1/2" 12 RECEPTACLES (OPEN /SUPPORT) 1 -20 720 #12 1/2" 13 RECEPTACLES (OPEN /SUPPORT) 1 -20 720 #12 1/2" 14 RECEPTACLES (OPEN /SUPPORT) 1 -20 720 #12 1/2" 15 RECEPTACLES (OPEN /SUPPORT) 1 -20 720 #12 1/2" 16 RECEPTACLES (OPEN /SUPPORT) 1 -20 720 #12 1/2" 17 RECEPTACLES (OPEN /SUPPORT) 1 -20 720 #12 1/2" 18 RECEPTACLES (OPEN /SUPPORT) 1 -20 720 #12 1/2" 19 RECEPTACLES (OPEN /SUPPORT) 1 -20 720 #12 1/2" 20 RECEPTACLES (OPEN AREA) 1 -20 1440 #12 1/2" 21 RECEPTACLES (OPEN AREA) 1 -20 1440 #12 1/2" 22 RECEPTACLES (OPEN AREA) 1 -20 1440 #12 1/2" 23 RECEPTACLES (SAMANTHA) 1 -20 720 #12 1/2" 24 RECEPTACLES (NURSE STATION) 1 -20 720 #12 1/2" 25 RECEPTACLES (NURSE STATION) 1 -20 900 #12 1/2" 26 REFRIGERATOR (BREAK ROOM) 1 -20 1000 #12 1/2" 27 RECEPTACLES (BREAK ROOM) 1 -20 1500 #12 1/2" 28 REFRIGERATOR (BREAK ROOM) 1 -20 1000 #12 1/2" 29 DRINKING FOUNTAIN (CORRIDOR) 1 -20 1500 #12 1/2" 30 RECEPTACLES (RESTROOMS) 1 -20 1440 #12 1/2" 31 SPACE 32 SPACE 33 1 34 35 36 37 38 39 40 41 42 TOTAL CONNECTED LOAD: 31.4 KVA (87 AMPS) X—RAY EQUIP. X—RAY EQUIP. NEW PANEL "M" ®' • 000000�0��0 EXISTING CONNECTED • . NOTE: CONNECTED NEW • TOTAL • . ••D • AMPS) VOLTS: 120/208V, 30, 4W MOUNTING: RECESSED RATING: 225 AMPS NEW » » PANELBOARD M TYPE: SQUARE D MAINS: 150 AMPS MCB AIC: 22,000 THE CONTRACTOR, BY VIRTUE OF � o U Z DESCRIPTION -i IL 0 FE °a OJ w 3 zz OU � o U z DESCRIPTION -i a_ 0 Fr > °a OJ w zz 0 1 LIGHTING (BATHROOMS) 1 -20 1200 #12 1/2" 2 1 LIGHTING (OPEN AREA) 1 -20 1600 #12 1/2" 3 LIGHTING ( BERAK RM, NURSE ST) 1 -20 1600 #12 1/2- 4 LIGHTING (OPEN /SUPPORT) 1 -20 1600 #12 1/2" 5 LIGHTING (OPEN /SUPPORT) 1 -20 1600 #12 1/2" 6 LIGHTING (OPEN /SUPPORT) 1 -20 700 #12 1/2" 7 LIGHTING (OPEN /SUPPORT) 1 -20 1400 #12 1/2" 8 RECEPTACLES (OPEN /SUPPORT) 1 -20 720 #12 1/2" 9 RECEPTACLES (OPEN /SUPPORT) 1 -20 720 #12 1/2" 10 RECEPTACLES (OPEN /SUPPORT) 1 -20 720 #12 1/2" 11 RECEPTACLES (OPEN /SUPPORT) 1 -20 720 #12 1/2" 12 RECEPTACLES (OPEN /SUPPORT) 1 -20 720 #12 1/2" 13 RECEPTACLES (OPEN /SUPPORT) 1 -20 720 #12 1/2" 14 RECEPTACLES (OPEN /SUPPORT) 1 -20 720 #12 1/2" 15 RECEPTACLES (OPEN /SUPPORT) 1 -20 720 #12 1/2" 16 RECEPTACLES (OPEN /SUPPORT) 1 -20 720 #12 1/2" 17 RECEPTACLES (OPEN /SUPPORT) 1 -20 720 #12 1/2" 18 RECEPTACLES (OPEN /SUPPORT) 1 -20 720 #12 1/2" 19 RECEPTACLES (OPEN /SUPPORT) 1 -20 720 #12 1/2" 20 RECEPTACLES (OPEN AREA) 1 -20 1440 #12 1/2" 21 RECEPTACLES (OPEN AREA) 1 -20 1440 #12 1/2" 22 RECEPTACLES (OPEN AREA) 1 -20 1440 #12 1/2" 23 RECEPTACLES (SAMANTHA) 1 -20 720 #12 1/2" 24 RECEPTACLES (NURSE STATION) 1 -20 720 #12 1/2" 25 RECEPTACLES (NURSE STATION) 1 -20 900 #12 1/2" 26 REFRIGERATOR (BREAK ROOM) 1 -20 1000 #12 1/2" 27 RECEPTACLES (BREAK ROOM) 1 -20 1500 #12 1/2" 28 REFRIGERATOR (BREAK ROOM) 1 -20 1000 #12 1/2" 29 DRINKING FOUNTAIN (CORRIDOR) 1 -20 1500 #12 1/2" 30 RECEPTACLES (RESTROOMS) 1 -20 1440 #12 1/2" 31 SPACE 32 SPACE 33 1 34 35 36 37 38 39 40 41 42 TOTAL CONNECTED LOAD: 31.4 KVA (87 AMPS) 151 SEVILLA AVENUE ,' ;ULTE 200 - „- -- CORAL GABLES, FL 33134 OFFICE: (305) 442 -1188 FAX: (305) 445 -1509 WWW. ADCINTERNATIONAL.NET STATE OF FLORIDA AR- 0010536 RAYMUNDO FEITO, R.A. AA- CO01315 Architect • Seal/Signature MRA EXPANSION SUNSET PROFESSIONAL 6280 SUNSET DR SUITE 600 SOUTH MIAMI (E FL Key Plan - Scope of Work Area Z KEY PLAN LEGEND AREA AT WHICH THE SCOPE OF ' WORK WILL BE PERFORMED. N.I.C. AREA ONSTRUCTION NOTE ;, * ,.,.; ,,•'' "' THE CONTRACTOR, BY VIRTUE OF SIGNING THE CONTRACT, ACKNOWLEDGESTHATHEAND ALL HIS SUBCONTRACTORS HAVE ;. SATISFIED THEMSELVES AS TO •. `' THE NATURE AND LOCATION OF ' `.` THE WORK THE GENERAL AND s - LOCAL CONDITIONS INCLUDE, BUT ARE NOT RESTRICTED TO THOSE BEARING UPON• ACCESS POINTS AND POINTS OF CONNECTION TO THE SITE; THE CONFORMATION r AND CONDITIONS OF THE WORK AREA; AND THE CHARACTER OF EQUIPMENT AND DEVICES NEEDED ' PRELIMINARY TO AND DURING THE i PERFORMANCE OF THE WORK. Project Number Client Name 09032 PROMED F IRDPERTIES Description Client Address ELECTRICAL PLAN 1696 NE MIAMI GAF4) i6 DR SUITE 8 Scale R MIAMI 5EACI4, FL 331719 AS SHOWN Client Phone Number (305) 947 -WW CAD File Name G:112F'rojoctev22009t,2ADCV2MRA EXPANSION FAILURE ON THE PART OF THE ` • - • CONTRACTOR TO COMPLETELY OR M` PROPERLY EVALUATE ANY FACTORS OF COSTS PRIOR TO ' ? BIDDING SHALL NOT FORMA BASIS FOR ADDITIONAL COMPENSATION IF HE IS AWARDED THE CONTRACT. Date & Issue Description Drawn By Checked By CDConsultant • Seal/Signature z ENGINEERING J DESIG 6.! �ORP.' U : o a 21 SW 102 Ct. Mia � 4 '� Office: (786) 863= Fax: (305) 220 -5196 pgengineerdesign@bellsouth .net, . U W ■ .J WSTATE OF FLORIDA LUIS O. PEREZ, PE P.E. No. 62586 Date & Issue Description Drawn By Checked By Project Number Client Name 09032 PROMED F IRDPERTIES Description Client Address ELECTRICAL PLAN 1696 NE MIAMI GAF4) i6 DR SUITE 8 Scale R MIAMI 5EACI4, FL 331719 AS SHOWN Client Phone Number (305) 947 -WW CAD File Name G:112F'rojoctev22009t,2ADCV2MRA EXPANSION CDConsultant • Seal/Signature z ENGINEERING J DESIG 6.! �ORP.' U : o a 21 SW 102 Ct. Mia � 4 '� Office: (786) 863= Fax: (305) 220 -5196 pgengineerdesign@bellsouth .net, . U W ■ .J WSTATE OF FLORIDA LUIS O. PEREZ, PE P.E. No. 62586